LM-79 Test Report LM79-RUBY-BRACKET-6-2700K-CRI80-FLOOD CLS LED BV [email protected] www.cls-led.com 2017 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. No part of this document may be reproduced, in any form or by any means, without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions, found on the back of your CLS-LED BV invoice, inside the CLS catalogue or on our website www.cls-led.com/voorwaarden.pdf General Discription Item number RU-36-X-X-01-3-X Date and time 18-11-2016 14:22:28 CCT (Kelvin) 2669 K Beam angle 63,9° Luminous flux 2584 lm Efficiency 90 lm/watt Weighted energy 28,6 kWh/1000h Power factor 0,99 CRI (RA) 81,8 Fidelity index Rf Rf 82,0 Gammut index Rg Rg 97,0 Peak 2605 cd

Transcript of LM -79 - CLS€¦ · Gammut index Rg Rg 97,0 Peak 2605 cd . economic loss or any other loss LM -79...

Page 1: LM -79 - CLS€¦ · Gammut index Rg Rg 97,0 Peak 2605 cd . economic loss or any other loss LM -79 Test Report LM79 -RUBY -BRACKET -6-2700K -CRI80 -FLOOD CLS LED BV info@cls -led.com

LM-79 Test Report

LM79-RUBY-BRACKET-6-2700K-CRI80-FLOOD

CLS LED BV [email protected] www.cls-led.com

2017 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. No part of this document may be reproduced, in any form or by any means, without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions, found on the back of your CLS-LED BV invoice, inside the CLS catalogue or on our website www.cls-led.com/voorwaarden.pdf

General Discription

Item number RU-36-X-X-01-3-X

Date and time 18-11-2016 14:22:28

CCT (Kelvin) 2669 K

Beam angle 63,9°

Luminous flux 2584 lm

Efficiency 90 lm/watt

Weighted energy 28,6 kWh/1000h

Power factor 0,99

CRI (RA) 81,8

Fidelity index Rf Rf 82,0

Gammut index Rg Rg 97,0

Peak 2605 cd

Page 2: LM -79 - CLS€¦ · Gammut index Rg Rg 97,0 Peak 2605 cd . economic loss or any other loss LM -79 Test Report LM79 -RUBY -BRACKET -6-2700K -CRI80 -FLOOD CLS LED BV info@cls -led.com

LM-79 Test Report

LM79-RUBY-BRACKET-6-2700K-CRI80-FLOOD

CLS LED BV [email protected] www.cls-led.com

2017 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. No part of this document may be reproduced, in any form or by any means, without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions, found on the back of your CLS-LED BV invoice, inside the CLS catalogue or on our website www.cls-led.com/voorwaarden.pdf

Beam details 1m 2m 3m 4m 5m

Lux* 2597 lx 649 lx 289 lx 162 lx 104 lx

63,9°

*measured at center of beam Footcandles* 241,3 fcd 60,3 fcd 26,8 fcd 15,1 fcd 9,7 fcd

Beam width (meter) 1,2 m 2,5 m 3,7 m 5 m 6,2 m

Beam width (Feet) 4,1 ft 8,2 ft 12,3 ft 16,4 ft 20,5 ft

Beam intensities

1m 2m 3m 4m 5m 6m 7m 8m 9m 10m 11m 12m 13m 14m 15m 16m 17m 18m 19m 20m

2597lx 649lx 289lx 162lx 104lx 72lx 53lx 41lx 32lx 26lx 21lx 18lx 15lx 13lx 12lx 10lx 9lx 8lx 7lx 6lx

3,3ft 6,6ft 9,8ft 13,1ft 16,4ft 19,7ft 23ft 26,2ft 29,5ft 32,8ft 36,1ft 39,4ft 42,7ft 45,9ft 49,2ft 52,5ft 55,8ft 59,1ft 62,3ft 65,6ft

241,3fcd

60,3fcd 26,8fcd 15,1fcd 9,7fcd 6,7fcd 4,9fcd 3,8fcd 3fcd 2,4fcd 2fcd 1,7fcd 1,4fcd 1,2fcd 1,1fcd 0,9fcd 0,8fcd 0,7fcd 0,7fcd 0,6fcd

Intensities in 0° c-plane

0° 2° 4° 6° 8° 10° 12° 14° 16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38°

2597 2589 2589 2559 2505 2446 2348 2249 2147 2043 1941 1855 1769 1677 1581 1467 1297 1127 914 691

100% 100% 100% 99% 96% 94% 90% 87% 83% 79% 75% 71% 68% 65% 61% 56% 50% 43% 35% 27%

Intensities in 90° c-plane 0° 2° 4° 6° 8° 10° 12° 14° 16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38°

2597 2605 2605 2579 2531 2478 2379 2279 2172 2060 1951 1860 1769 1673 1576 1460 1291 1121 911 691

100% 100% 100% 99% 97% 95% 92% 88% 84% 79% 75% 72% 68% 64% 61% 56% 50% 43% 35% 27%

Intensities in 180° c-plane 0° 2° 4° 6° 8° 10° 12° 14° 16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38°

2597 2589 2589 2559 2505 2446 2348 2249 2147 2043 1941 1855 1769 1677 1581 1467 1297 1127 914 691

100% 100% 100% 99% 96% 94% 90% 87% 83% 79% 75% 71% 68% 65% 61% 56% 50% 43% 35% 27%

Intensities in 270° c-plane

0° 2° 4° 6° 8° 10° 12° 14° 16° 18° 20° 22° 24° 26° 28° 30° 32° 34° 36° 38°

2597 2605 2605 2579 2531 2478 2379 2279 2172 2060 1951 1860 1769 1673 1576 1460 1291 1121 911 691

100% 100% 100% 99% 97% 95% 92% 88% 84% 79% 75% 72% 68% 64% 61% 56% 50% 43% 35% 27%

Beam angle 50% Field angle 10% Cutoff angle 2,5% Intensity ratio in 120° cone Intensity ratio in 90° cone

63,9° 88,3° 112,9° 98,1% 92,6%

Page 3: LM -79 - CLS€¦ · Gammut index Rg Rg 97,0 Peak 2605 cd . economic loss or any other loss LM -79 Test Report LM79 -RUBY -BRACKET -6-2700K -CRI80 -FLOOD CLS LED BV info@cls -led.com

400 450 500 550 600 650 700 750 800

2200

K

2700

K30

00 K

3500

K40

00 K

5000

K60

00 K

7000

K

8000

K

9000

K

10000 K

12000 K

15000 K

20000 K

40000 K

450

460

470

480

490

500

510

520

530

540

550

560

570

580

590

600

610

620

630

75

Q1

94

Q2

82

Q3

80

Q4

82

Q5

81

Q6

80

Q7

83

Q8

94

Q9

88

Q10

85

Q11

82

Q12

81

Q13

70

Q14

72

Q15

77

C1

77

C2

72

C3

84

C4

90

C5

90

C6

85

C7

91

C8

87

C9

84

C10

80

C11

83

C12

85

C13

78

C14

80

C15

74

C16

80

R1

90

R2

96

R3

80

R4

80

R5

89

R6

81

R7

57

R86

R9

79

R10

79

R11

73

R12

82

R13

99

R14

72

R15

0,8

0,7

0,6

0,5

0,4

0,3

0,2

0,1

0,00,0 0,1 0,2 0,3 0,4 0,5 0,6 0,7

2200

K

2700

K

3000

K

3500

K40

00 K

5000

K60

00 K

7000

K80

00 K

9000

K10

000 K

1200

0 K

1500

0 K

2000

0 K

40000 K

45046

0

470

480

490

500

510

520

530

540

550

560

570

580

590

600

610

620

630

LM-79 Test Report

LM79-RUBY-BRACKET-6-2700K-CRI80-FLOOD

CLS LED BV [email protected] www.cls-led.com

2017 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. No part of this document may be reproduced, in any form or by any means, without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions, found on the back of your CLS-LED BV invoice, inside the CLS catalogue or on our website www.cls-led.com/voorwaarden.pdf

Color details

CIE 1931 x: 0,462 Spectra CIE 1931 ZOOM

2669 K y: 0,410 Δuv: 0,0005

CRI: 81,8 (R1-R8) CRI values, R1-R8 are used to calculate final CRI value

R1 R2 R3 R4 R5 R6 R7 R8

80,1 90,5 96,5 79,7 79,9 89,1 81,5 56,8

R9 R10 R11 R12 R13 R14 R15

6,0 78,7 79,2 73,3 82,4 98,8 71,8

CQS: 80,7 CQS values

Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8

75,0 93,8 82,3 79,7 82,0 81,3 80,4 83,2

Q9 Q10 Q11 Q12 Q13 Q14 Q15

94,1 88,1 84,9 82,0 81,0 70,4 71,6

TM30: 82,0 TM30 values, 16 binned values out of total of 99 values

C1 C2 C3 C4 C5 C6 C7 C8

76,8 77,3 72,4 84,5 90,5 90,2 84,7 90,6

C9 C10 C11 C12 C13 C14 C15

87,4 83,6 80,0 82,6 84,9 77,5 79,9

Color parameters Color

temperature Color rendering

index Red component Color fidelity Color gamut Color quality

scale Color coordinate

cie 1931 Color coordinate

cie 1931 Color

coordinate Color

coordinate Color diviation

from black body

CCT CRI CRI R9 TM30 Rf TM30 Rg CQS x y u v Δuv

2669 K 81,8 6,0 82,0 97,0 80,7 0,462 0,410 0,264 0,352 0,0005

Page 4: LM -79 - CLS€¦ · Gammut index Rg Rg 97,0 Peak 2605 cd . economic loss or any other loss LM -79 Test Report LM79 -RUBY -BRACKET -6-2700K -CRI80 -FLOOD CLS LED BV info@cls -led.com

-12%-9%

-3%

3% 5% 6%

0% -3%-6% -5%

-2%

6% 6% 5%

-2%-9%

77 7772

8490 90

8591 87

84 80 83 8578 80

74

LM-79 Test Report

LM79-RUBY-BRACKET-6-2700K-CRI80-FLOOD

CLS LED BV [email protected] www.cls-led.com

2017 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. No part of this document may be reproduced, in any form or by any means, without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions, found on the back of your CLS-LED BV invoice, inside the CLS catalogue or on our website www.cls-led.com/voorwaarden.pdf

TM30 details

Rf 82,0

Fidelity index Rf

Rg 97,0

Gammut index Rg

Hue binH Color vector graphics

Hue bin Color distortion graphics

Color Evaluation Sample

CES99

CES97

CES95

CES93

CES91

CES89

CES87

CES85

CES83

CES81

CES79

CES77

CES75

CES73

CES71

CES69

CES67

CES65

CES63

CES61

CES59

CES57

CES55

CES53

CES51

CES49

CES47

CES45

CES43

CES41

CES39

CES37

CES35

CES33

CES31

CES29

CES27

CES25

CES23

CES21

CES19

CES17

CES15

CES13

CES11

CES09

CES07

CES05

CES03

CES01

100

80

60

40

20

0 Fid

elit

y In

de

x, R

f

100

90

80

70

60

50

20% 15% 10%

5% 0%

-5% -10% -15% -20%

140

130

120

110

100

90

80

70

60

50 60 70 80 90 100

Rg

Rf

Graphic shifts (%)

Hue Bin Rf Chroma Hue

1 77 -12% -1%

2 77 -9% 8%

3 72 -3% 13%

4 84 3% 8%

5 90 5% 5%

6 90 6% -2%

7 85 0% -9%

8 91 -3% -4%

9 87 -6% 0%

10 84 -5% 8%

11 80 -2% 12%

12 83 6% 3%

13 85 6% -8%

14 78 5% -15%

15 80 -2% -11%

16 74 -9% -15%

Rf

by

hu

e

Ch

rom

a sh

ift

by

hu

e

Page 5: LM -79 - CLS€¦ · Gammut index Rg Rg 97,0 Peak 2605 cd . economic loss or any other loss LM -79 Test Report LM79 -RUBY -BRACKET -6-2700K -CRI80 -FLOOD CLS LED BV info@cls -led.com

LM-79 Test Report

LM79-RUBY-BRACKET-6-2700K-CRI80-FLOOD

CLS LED BV [email protected] www.cls-led.com

2017 CLS-LED BV. All rights reserved. Information subject to change without notice, CLS-LED BV and all affiliated companies disclaim liability for injury, damage direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document. No part of this document may be reproduced, in any form or by any means, without permission in writing from CLS-LED BV. Other legal information can be found in our General conditions, found on the back of your CLS-LED BV invoice, inside the CLS catalogue or on our website www.cls-led.com/voorwaarden.pdf

Glare Evaluation According to UGR

p Ceiling 70 70 50 50 30 70 70 50 50 30

p Walls 50 30 50 30 30 50 30 50 30 30

p Floor 20 20 20 20 20 20 20 20 20 20

Room size X Y

Viewing direction at right angles to lamp axis Viewing direction parallel to lamp axis

2H 2H 21,4 22,1 21,7 22,3 22,6 21,4 22,1 21,7 22,3 22,6

3H 21,3 22,0 21,6 22,2 22,5 21,3 22,0 21,6 22,2 22,5

4H 21,2 21,9 21,5 22,1 22,4 21,2 21,9 21,5 22,1 22,4

6H 21,2 21,7 21,5 22,0 22,3 21,2 21,7 21,5 22,0 22,3

8H 21,1 21,7 21,5 22,0 22,3 21,1 21,7 21,5 22,0 22,3

12H 21,1 21,6 21,4 21,9 22,3 21,1 21,6 21,4 21,9 22,3

4H 2H 21,2 21,9 21,6 22,1 22,4 21,2 21,9 21,6 22,1 22,4

3H 21,2 21,7 21,5 22,0 22,3 21,2 21,7 21,5 22,0 22,3

4H 21,1 21,5 21,5 21,9 22,2 21,1 21,5 21,5 21,9 22,2

6H 21,0 21,4 21,4 21,8 22,2 21,0 21,4 21,4 21,8 22,2

8H 21,0 21,3 21,4 21,7 22,1 21,0 21,3 21,4 21,7 22,1

12H 20,9 21,2 21,4 21,7 22,1 20,9 21,2 21,4 21,7 22,1

8H 4H 21,0 21,3 21,4 21,7 22,1 21,0 21,3 21,4 21,7 22,1

6H 20,9 21,2 21,4 21,6 22,1 20,9 21,2 21,4 21,6 22,1

8H 20,9 21,1 21,3 21,5 22,0 20,9 21,1 21,3 21,5 22,0

12H 20,8 21,0 21,3 21,5 22,0 20,8 21,0 21,3 21,5 22,0

12H 4H 20,9 21,2 21,4 21,7 22,1 20,9 21,2 21,4 21,7 22,1

6H 20,9 21,1 21,3 21,5 22,0 20,9 21,1 21,3 21,5 22,0

8H 20,8 21,0 21,3 21,5 22,0 20,8 21,0 21,3 21,5 22,0

Variation of the observer position for the luminaire distance S

S = 1,0H +4,0 / -6,2 +4,0 / -6,2

S = 1,5H +6,6 / -8,4 +6,6 / -8,4

S = 2,0H +8,6 / -11,2 +8,6 / -11,2

Standard table BK00 BK00

Correction summand 2,8 2,8

Corrected glare indices referring to 2584lm total luminous flux

Color distortion graphics