Lingenfelter LNC-003 Dual RPM Launch Controller LNC-003...Page 5 of 11 Launch Control/2-Step...

12
Installation Instructions For Lingenfelter LNC-003 Dual RPM Launch Controller Adjustable 2-Step RPM Limiter For GM LSx Series Engines PN: L460105297 1557 Winchester Road Decatur, Indiana 46733 260 724 2552 phone 260 724 8761 fax www.lingenfelter.com

Transcript of Lingenfelter LNC-003 Dual RPM Launch Controller LNC-003...Page 5 of 11 Launch Control/2-Step...

Page 1: Lingenfelter LNC-003 Dual RPM Launch Controller LNC-003...Page 5 of 11 Launch Control/2-Step Features The independent coil drive of the LNC-003 provides sequential ignition kill when

Installation Instructions For

Lingenfelter LNC-003Dual RPM Launch Controller

Adjustable 2-Step RPM Limiter For GM LSx Series Engines

PN: L4601052971557 Winchester RoadDecatur, Indiana 46733 260 724 2552 phone

260 724 8761 faxwww.lingenfelter.com

Page 2: Lingenfelter LNC-003 Dual RPM Launch Controller LNC-003...Page 5 of 11 Launch Control/2-Step Features The independent coil drive of the LNC-003 provides sequential ignition kill when

Parts List # Part number Description 1 LNC-003 LPE Dual RPM Launch Controller 1 72” trigger wire harness (part of PN LNC-003) 2 hook & loop tape, 3.5” length 4 AV16037 self-tapping screw 1 L920010000 LPE decal 1 instructions

Optional Items • Transientvoltagesuppressiondiode L450080000 •MPHactivatedswitch L460050000 • LEDforindicatorlight • Red12vdcLEDwith30cmleads L450030000 •Green12vdcLEDwith30cmleads L450040000 • Sealed40ampheavydutyrelaykit L450100000 • RedLEDlightedpaddletoggleswitch,20amp DC-7600500

Specifications:• CustommoldedhightemperatureglassfilledNylon6enclosurewithdirectaccesstothecontroller

settingswithoutrequiringremovalofacoveroraccesspanel.• 40MHz16-bitautomotivequalifiedprocessorwitheightchannelEnhancedTimeModule.• EachcoildrivecircuithasadedicatedtimertokeepthetimingaccurateoverthefullRPMrange.• IndependentcoildriveprovidesSequentialIgnitionKillwhenRPMlimitingisactive.• Reversebatteryprotection.• Bothoftheactivationinputshaveactiveclampsandopticalisolationtosuppresselectricalnoise

fromexternalsolenoids(suchastransbrakeandlinelock).• Digitalfilterprovidedinsoftwaretofurtherisolateelectricalnoiseontheactivationinputs.• SeparatePrimaryandSecondaryRPMx100&RPMx1000switchesforeasiersettingadjustments.• RPMlimiteractivationpointcanbeadjustedfrom1500to9,900RPMin100RPMincrements.• Both Ground Activation and +12 Volt ActivationinputsareprovidedforthePrimaryRPMlimit

activation.• Dedicated+12voltactivationinputfortheSecondaryRPMlimiter.• Trueplug-and-playcoilpackconnectiondesignforeaseofinstallationandremoval.• Fullyencapsulated(potted)constructionforaddeddurability.• 90daywarranty(fromdateofpurchase).

Page 1 of 11

Page 3: Lingenfelter LNC-003 Dual RPM Launch Controller LNC-003...Page 5 of 11 Launch Control/2-Step Features The independent coil drive of the LNC-003 provides sequential ignition kill when

LNC-003 description:TheLNC-003DualRPMLaunchControllerisatrue2-StepsparkbasedRPMlimiterforusewithLSxbasedenginesandignitionsystems.TheLNC-003providestwoRPMlimitsettings-aPrimaryandaSecondary.

TheLNC-003canbeusedtoprovideconsistentlaunchRPMoffthelineindragracingandotherstandingstartracingapplications.InturbochargedapplicationstheLNC-003canalsobeusedtoloadtheengineandhelpbuildadditionalboostofftheline.

TheLNC-003canalsobeusedasanadjustableindividualcylinderRPMlimiter,providingreliableandfastactingsparkbasedengineRPMlimitcontrol.ThisisespeciallyusefulinvehiclesthathaveauxiliaryfuelcontrolsystemswhereitisnotpossibletomakesurethatboththefactoryECM/PCMandtheauxiliarysystemsbothturnofffuelatexactlythesametime.Thereasonthisisimportantisthatifthetwodon’tcompletelycutfuelatthesametimeyouwillrunleanwhentheonesystemcutsofftheinjectors(butnottheother),riskingsevereenginedamage.

WARNINGS:

The RPM limiter function of the LNC-003 acts by disabling spark to individual cylinders and not fuel like most production RPM limiters so the 2-Step/Launch Control function is not meant for use on the street or for use on cars equipped with catalytic converters. The 2-Step/Launch Control function of the LNC-003 is only for use at the race track on race vehicles not equipped with catalysts. Failure to follow these precautions can result in premature catalyst failure.

DO NOT operate the engine with the LNC-003 RPM limit active for extended periods of time. Due to the raw fuel in the exhaust when the RPM limit is active, a risk of backfiring exists if you do so.

DO NOTplaceindirectexposuretoexhaustmanifolds,turbochargerturbinehousingsorotherunderhooditemsthatarehightemperatureheatsources(radiatedheatsources).Thewarrantydoesnotcoverdamageduetomeltedenclosuresorwiringduetoimproperinstallation.

Do NOTsubmergetheControllerinliquidordirectlywashtheunitwithliquidofanytype!TheswitchesontheLNC-003aresealedbutareNOTratedforhighpressurewash,usecautionifpowerwashing near the LNC-003 controller

Page 2 of 11

Page 4: Lingenfelter LNC-003 Dual RPM Launch Controller LNC-003...Page 5 of 11 Launch Control/2-Step Features The independent coil drive of the LNC-003 provides sequential ignition kill when

Page 3 of 11

Switches and indicator lights:Red (Power) LED:• Comesonsolidonstart-up(poweron)• WhenactiveRPMisreached,redLEDwill

blink(evenifactivationwireisnottriggered)Green (Activation) LED:• Slowblinkrate(4Hz)forPrimaryActivation

only• Mediumblinkrate(8Hz)forSecondary

Activationonly• Fastblinkrate(16Hz)forbothPrimaryandSecondaryinputsonSettings:• Controlledbytwo(2)tenpositionswitches(PrimaryRPM)andtwo(2)sixteenpositionswitches

(Secondary RPM limit) o Two(2)tenpositionswitchesforselectinghundredsofRPM(x100)andthousandsofRPM(x1000)

forthePrimaryRPMlimitsetting o Two(2)sixteenpositionswitchesforselectinghundredsofRPM(x100)andthousandsofRPM

(x1000)fortheSecondaryRPMlimitsetting.Switchpositionsafter9notused.Notes:• TheLNC-003RPMlimiterfunctionwillnottriggeratRPMlevelsbelow1500RPM• IfboththePrimaryandtheSecondaryRPMlimitareenabledthenthePrimarysettingisselected• ThePrimaryRPMlimitsettingcanbesethigherorlower(orthesameas)theSecondaryRPMlimit

setting• Changes to the switch point settings (RPM, Degrees, Rate) must be done with the ignition off

o Theswitchpositionsareonlyreadonstartup

Example settings:

• 1900RPMactivationpointforlaunchcontrolo Upper(x100)RPMswitchonposition9o Lower(x1000)RPMswitchonposition1

• 6900RPMactivationpointforRPMlimitero Upper(x100)RPMswitchonposition9o Lower(x1000)RPMswitchonposition6 0 56789

1234

0 567891234

100's Switch (x100 RPM)

1000's Switch (x1000 RPM)

RPM ProgrammingSwitches

0 567891234

0 567891234

100's Switch (x100 RPM)

1000's Switch (x1000 RPM)

RPM ProgrammingSwitches

Page 5: Lingenfelter LNC-003 Dual RPM Launch Controller LNC-003...Page 5 of 11 Launch Control/2-Step Features The independent coil drive of the LNC-003 provides sequential ignition kill when

Page 4 of 11

Installation:• Makesuretheignitionisoffbeforebeginning

installation.• YoucanmounttheLNC-003usingthesuppliedhook

and loop tape or the supplied self tapping screws.• DoNOTmounttheLNC-003directlyontopofthe

engineorneartheexhaustmanifoldsduetoheatconcerns.

• DoNOTmounttheLNC-003inthelineofsiteofhightemperatureobjectssuchasexhaustmanifolds,turbinehousingsetc.Ifneeded,putaheatshieldinbetweentheheatsourceandthemoduletoprotecttheplasticcase.

• DoNOTinstallwithin6”ofnitroussolenoidsorotherdeviceswithstrongmagneticfields.• Ifyouhaverelocatedcoilpacks,donotrunthehighvoltagesparkplugwiresalongsidethelow

voltagecoilpackwires.Keepthewiresasfarapartaspossibleand,iftheydohavetointersect,havethemintersectatrightangles.

• Disconnectthepackconnectorsoneachsideoftheengine and then plug the LNC-003 wiring harnesses in betweenoneachside.ItdoesnotmatterwhichbankofcylinderseachsideoftheLNC-003harnessconnectsto.

• Theonlywiringthatisrequiredisforthetriggerwire(s)dependingonhowyouwanttoenablethedevice.Seepage7foranexamplevehiclewiringdiagram.

• ThepossiblePrimaryRPMtrigger/activationconnectionmethodsare:• Groundactivationwire(green)-connectthiswiretoasourcethatsuppliesagroundpathwhen

youwanttheLNC-003tobecomeactive• +12voltactivationwire(yellow)-connectthiswiretoasourcethatsupplies+12voltswhen

youwanttheLNC-003tobecomeactive(i.e.brakelightswitch,line-locksolenoid)• Switchconnectedinbetweenthegroundactivationwireandthe+12voltactivationwire(green

wireconnectedtoyellowwirethroughaswitch,usuallyamomentaryswitch)• Groundactivationwireconnectedto+12voltactivationwire(greenconnectedtoyellow)for

standardRPMlimiteroperation(LNC-003alwaysactive)• SetthedesiredPrimaryRPMswitchactivationpointusingthetwotenpositionrotaryswitchesfor

the1000RPMincrement(x1000)andthe100RPMincrement(x100).• TheSecondaryRPMtrigger/activationconnectionmethodis:

• +12voltactivationwire(orange)-connectthiswiretoasourcethatsupplies+12voltswhenyouwanttheSecondaryRPMlimitoftheLNC-003tobecomeactive(i.e.brakelightswitch,line-locksolenoid)

• SetthedesiredSecondaryRPMswitchactivationpointusingthetwo(2)sixteenpositionswitchesforselectinghundredsofRPM(x100)andthousandsofRPM(x1000)fortheSecondaryRPMlimitsetting.Switchpositionsafter9arenotused.

Page 6: Lingenfelter LNC-003 Dual RPM Launch Controller LNC-003...Page 5 of 11 Launch Control/2-Step Features The independent coil drive of the LNC-003 provides sequential ignition kill when

Page 5 of 11

Launch Control/2-Step FeaturesTheindependentcoildriveoftheLNC-003providessequentialignitionkillwhenRPMlimitingisactive.ThedesiredRPMlimitingissetasshownonpage3.TheactivationforthePrimaryRPMsettingoftheLaunchControl/2-Stepfunctioniscontrolledbytheground(green)or+12volt(yellow)activationwires.TheactivationfortheSecondaryRPMsettingoftheLaunchControl/2-Stepfunctioniscontrolledbythe+12volt(orange)activationwire.

Ifyouaretriggeringoffoftheclutchswitch,the2-Stepwilltriggereachtimeyoudepresstheclutchpedal.Thiscanbeusedtoprovideanignitioncut/torquecutoneachgearchangetopotentiallyallowforfastershifts/fasterclutchengagement.

Ifyoudonotwantthe2-SteptotriggerwhenyouengagetheclutchpedalonceyouaremovingthenyouwillneedtoinstallamomentaryswitchorusetheLingenfelterMPHactivatedswitch.WiththeMPHactivatedswitchyoucansetatwhatMPHyouwantthe2-Stepactivationtobedisabled.Additional notes:TheLNC-003isdesignedforuseonallknownGMLSseriesengineapplications(LS1,LS6,LS2,LS7,LS3,LQ4,L76,L92andotherGenIIIandIVGMV8applicationsalongwithotherGMV8enginesusingthesameignitioncoilsystem)includingthefollowingvehicles:

• 1997-2004C5Corvette• 2005-2009C6Corvette(includingZ06)• 1998-2002LS1V8equippedCamaroandFirebird• 2004-2006PontiacGTO• 2008-2009PontiacG8withtheL76ortheLS3engine• 2004-2006CadillacCTS-V• 1999-2008GMCKtrucks(Tahoe,Yukon,Escalade,H2,Sierra,Silverado,Avalanche)withthe4.8,5.3,6.0and

6.2LGenIIIandIVV8engines(willnotworkon305&350Vortecengines)• 2003-2006ChevroletSSR• 2006-2008TrailblazerSSandotherS/Tbodytruckswiththe4.8,5.3and6.0LGenIII&IVGMV8engines

TheLNC-003shouldfunctiononthefollowingvehicles/enginesbuthasnotyetbeentestedonthem:• CKtruckswith8.1LV8engines(L19)withindividualcoilignitions• Frontwheeldrive5.3LLS4GenIVV8equippedcars(ImpalaSS,GrandPrix&MonteCarlo)

TheLNC-003shouldalsofunctionwiththeseproductsbuthasnotyetbeentestedwiththem:• AftermarketcoilsfortheLSseriesengines(suchastheMSDcoils)usedwithGMECM/PCM.• Aftermarketenginemanagementsystemsandignitionsystems(Accel,BigStuff3,Motec,FAST,MSD,etc.)thatrun

theproductionGMcoils.

The LNC-003 will NOT work with other individual coil ignition systems like those found on the GM Northstar or Ecotec engines or on the Ford modular V8 and the Chrylser Hemi V8.Important Information regarding spark plug wires and spark plugs:YoumustusenoisesuppressionignitionwiresandresistortypesparkplugswiththisController.TheLNC-003ControllercontainsHighFrequencyDigitalElectronicsandwillNOTfunctioncorrectlywithoutNoiseSuppressionWires!

Nitrous, line-lock and trans-brake solenoid warning:

LPEhasfoundthatthesesolenoidscancausefly-backvoltagelevelsattimesinexcessof600volts.ThesevoltagelevelshavethepotentialtodamagesensitiveelectronicsincludingtheLNC-003,thePCM/ECMandothermodulesinthevehicle.LingenfelterPerformanceEngineeringhasdevelopeda

Page 7: Lingenfelter LNC-003 Dual RPM Launch Controller LNC-003...Page 5 of 11 Launch Control/2-Step Features The independent coil drive of the LNC-003 provides sequential ignition kill when

Page 6 of 11

transientvoltagesuppression(TVS)diodekit(PNL450080000)forusewithline-locksolenoids,trans-brakesolenoidsandotheraftermarketautomotivesolenoidsofthistype.LPErecommendstheuseofournoisesuppressiondiodeonallvehiclesthathavealinelockortrans-brake.

For additional product installation information and technical support, contact LPE or your LPE products distributor. You can also find technical support and usage discussions regarding this product and many other LPE products in our Internet forums:

http://www.lingenfelter.com/LPEforumfiles

NOTICES:Itistheresponsibilityofthepurchasertofollowallguidelinesandsafetyproceduressuppliedwiththisproductandanyothermanufacturesproductusedwiththisproduct.Itisalsotheresponsibilityofthepurchasertodeterminecompatibilityofthisdevicewiththevehicleandothercomponents.LingenfelterPerformanceEngineeringassumesnoresponsibilityfordamagesresultingfromaccident,improperinstallation,misuse,abuse,improperoperation,lackofreasonablecare,orallpreviouslystatedreasonsduetoincompatibilitywithothermanufacturer’sproducts.LingenfelterPerformanceEngineeringassumesnoresponsibilityorliabilityfordamagesincurredfromtheuseofproductsmanufacturedorsoldbyLingenfelterPerformanceEngineeringonvehiclesusedforcompetitionracing.LingenfelterPerformanceEngineeringneitherrecommendsnorapprovestheuseofproductsmanufacturedorsoldbyLingenfelterPerformanceEngineeringonvehicleswhichmaybedrivenonpublichighwaysorroads,andassumesnoresponsibilityfordamagesincurredfromsuchuse.Itisthepurchaser’sresponsibilitytocheckthestateandlocallawsandsanctioningbodyrequirementspertainingtotheuseofthisproductforracingapplications.LingenfelterPerformanceEngineeringdoesnotrecommendnorcondonetheuseofitsproductsforillegalstreetracing.

1557 Winchester RoadDecatur, Indiana 46733 260 724 2552 phone

260 724 8761 faxwww.lingenfelter.com

Page 8: Lingenfelter LNC-003 Dual RPM Launch Controller LNC-003...Page 5 of 11 Launch Control/2-Step Features The independent coil drive of the LNC-003 provides sequential ignition kill when

Page 7 of 11

SecondaryRPM

x1000 x100

Orange = +12V SecondaryRPM Activation

LNC-003Dual RPM Launch Controller

Manual Transmission with Linelock

1

1 - Locate CPP (Clutch Position Switch) and unplug 2-wire connector.

2 - Cut wires appox. 3" back from connector.

3 - Find +12 volt Key On power source and connect to one wire of CPP connector.

4 - Splice two wires onto remaining CPP connector wire and connect one wire to #85 on Relay.The extra wire will be used for LNC-002 Launch Controller activation.

5 - Connect terminal #86 on Relay to Ground.

6 - Connect wires cut from CPP Switch connector to Terminals #30 and #87 as shown.

Wire color illustrated isfor 1999 TransAm

+12VFuse5 Amp

85

86

30

87a 87

2 3

64

Ground

5

Connect wires cut from CPPSwitch connector in Step 2 to Relay as shown.

General purposeAutomotive Relay.5 to 40 Amp

Toggle Switch

Arms Linelockand 2-Step

Ground

MomentarySwitch

85

86

30

87a 87

Ground

LinelockSolenoid

+12V

Ground

Optional LED, On whenArming Switch is ON andClutch Pedal is depressed.

Remove Switch andwire direct to make2-Step active withclutch switch only.

Relay can be omitted if Linelock Solenoidhas a lower current/amp draw than theMomentary Switch rating.

Secondary RPM Activation, apply a+12 volt signal to enable SecondaryLaunch RPM.

Page 9: Lingenfelter LNC-003 Dual RPM Launch Controller LNC-003...Page 5 of 11 Launch Control/2-Step Features The independent coil drive of the LNC-003 provides sequential ignition kill when

SecondaryRPM

x1000 x100

Orange = +12V SecondaryRPM Activation

LNC-003Dual RPM Launch Controller

Secondary RPM Activation, apply a+12 volt signal to enable SecondaryLaunch RPM.

Manual Transmission with Linelock & Nitrous

1

1 - Locate CPP (Clutch Position Switch) and unplug 2-wire connector.

2 - Cut wires appox. 3" back from connector.

3 - Find +12 volt Key On power source and connect to one wire of CPP connector.

4 - Splice two wires onto remaining CPP connector wire and connect one wire to #85 on Relay.The extra wire will be used for LNC-003 Launch Controller activation.

5 - Connect terminal #86 on Relay to Ground.

6 - Connect wires cut from CPP Switch connector to Terminals #30 and #87 as shown.

Wire color illustrated isfor 1999 TransAm

+12VFuse5 Amp

85

86

30

87a 87

2 3

64

Ground

5

Connect wires cut from CPPSwitch connector in Step 2 to Relay as shown.

General purposeAutomotive Relay.5 to 40 Amp

Toggle Switch

Arms Linelockand 2-Step

Ground

MomentarySwitch

85

86

30

87a 87

Ground

LinelockSolenoid

+12V

Ground

Optional LED, On whenArming Switch is ON andClutch Pedal is depressed.

Remove Switch andwire direct to make2-Step active withclutch switch only.

Relay can be omitted if Linelock Solenoidhas a lower current/amp draw than theMomentary Switch rating.

WOT Switch

85

86

30

87a 87

Ground

To Nitrous Relay

Page 8 of 11

Page 10: Lingenfelter LNC-003 Dual RPM Launch Controller LNC-003...Page 5 of 11 Launch Control/2-Step Features The independent coil drive of the LNC-003 provides sequential ignition kill when

Page 9 of 11

SecondaryRPM

x1000 x100

Orange = +12V SecondaryRPM Activation

LNC-003Dual RPM Launch Controller

Momentary Switch MUST be capable of supplying currentdraw of Linelock Solenoid. If switch is rated at a lower amperage

than the solenoid, a Relay MUST be used. See Diagram forManual Transmission installation for Relay wiring details.

Optional LED, On whenArming Switch is ON.

Automatic Transmission with Linelock

Secondary RPM Activation, apply a+12 volt signal to enable SecondaryLaunch RPM.

+12V

Toggle Switch

Ground

MomentarySwitch

Ground

LinelockSolenoid

(Arms 2-Step and Linelock)

Fuse20 Amp

Page 11: Lingenfelter LNC-003 Dual RPM Launch Controller LNC-003...Page 5 of 11 Launch Control/2-Step Features The independent coil drive of the LNC-003 provides sequential ignition kill when

Page 10 of 11

SecondaryRPM

x1000 x100

Orange = +12V SecondaryRPM Activation

LNC-003Dual RPM Launch Controller

Momentary Switch MUST be capable ofsupplying current draw of Linelock Solenoid.If switch is rated at a lower amperage thanthe solenoid, a Relay MUST be used. SeeDiagram for Manual Transmission installation for Relay wiring details.

Optional LED, On whenArming Switch is ON.

Automatic Transmission with Linelock & Nitrous

Ground

Secondary RPM Activation, apply a+12 volt signal to enable SecondaryLaunch RPM.

MomentarySwitch

+12V

Toggle Switch

Ground

MomentarySwitch

Ground

LinelockSolenoid

(Arms 2-Step and Linelock)

Fuse20 Amp

85

86

30

87a 87

WOT Switch

The "Nitrous Disable Relay" is used to disconnect the"Wide Open Throttle" switch from the Nitrous Relay.This allows the throttle to go wide open while theLinelock / 2-Step is Active and the Nitrous willremain OFF until the Linelock is released.

Nitrous Disable Relay

To Nitrous Relay

Page 12: Lingenfelter LNC-003 Dual RPM Launch Controller LNC-003...Page 5 of 11 Launch Control/2-Step Features The independent coil drive of the LNC-003 provides sequential ignition kill when

Page 11 of 11L460105297LNC-003DualRPMLaunchControllerv1.1.indd

C8 OUT

C7 OUT

C5 OUT

C3 OUT

C1 OUTC2 OUT

C4 OUT

C6 OUT

C8 IN

C6 IN

C4 IN

C2 IN

C1 IN

C3 IN

C5 IN

C7 IN

Black

Red

Purple

White

Green

Yellow

Blue

Gray

BrownOrange

Yellow

Blue

Gray

Red

Black

Brown

Orange

White

Purple

Green

+12V

GND

+12V

GND

Yellow

Green

ACT+

ACT-

BOTTOMHOLES

TOPHOLES

LNC-003 Wiring Diagram

Male Pin

Female Pin

Male Pin

Male Pin

G

F

B C

F G

CB

H

G

C

G F

B

F

B

CH

AA

H EFG

A B C

H EFG

A B C

HGFE

ABC

HGFE

ABC

Harness #1

Harness #2

20GA Jumper(s), 8" long.

MaleFemale

Female

Male

Female

Male

Cut harness wires 50" in length.Finished trim length = 48"

20 Gauge

Male Female

Male FemaleOrange

SECONDARY ACT+

Cut 4-Wires 6 Feet Long, 20 GaugeCut 4-Wires 14" Long20 Gauge

Cut Wire Loom 42" Long