Limited Service Electric Fire Pump Controller...GPL 1. ViZiTouch V2 operator interface 2. Exterior...
Transcript of Limited Service Electric Fire Pump Controller...GPL 1. ViZiTouch V2 operator interface 2. Exterior...
Tornatech Inc, Montreal, Quebec, Canada
LISTEN DEVELOP LEAD
Standard Features• ViZiTouch V2 operator interface• NEMA 2 enclosure• Available in single phase• Pressure and event recorder• Voltage and amperage display• Rotary type main disconnect switch complete with door interlock• Surge arrestor• Wall mounting lugs• Start and stop pushbuttons• Circuit breaker (150% - 250% of FLC)• Phase reversal indication• Remote start / deluge valve start provision• Pressure transducer• Alarm contacts for remote indication• Emergency manual start handle• Available with automatic power transfer switch
Model GPLLimited Service Electric Fire Pump Controller
LISTEN DEVELOP LEAD
2018-2019
Model GPL Limited ServiceElectric Fire Pump Controller
Model GPL+ GLU Limited ServiceElectric Fire Pump Controller
with Automatic Power Transfer Switch
Limitations• Across the line starting only• Horsepower rating of maximum 30hp• Can only be installed where acceptable by the authority having jurisdiction• Not accepted in FM insured property
— G
PL
1. ViZiTouch V2 operator interface2. Exterior USB Port
(Interior USB port also supplied)3. Emergency start
2
4
3
5
1
7
6
4. Key lock5. Remote alarm contacts with removable terminals6. Surge arrestor7. Transfer switch
— G
PL
ViZiTouch V2 Operator Interface
HOME SCREEN
Electric Fire Pump Controller
0
300
System
Home 26C13:34:102016.Dec.01
Pressure actuated Non automatic controller Automatic shutdown
L2
L3
L1480 V 480 V
480 V
23.4A
23.4A
23.4A
90
150
70PSI
0
300
System
Home 26C13:34:102016.Dec.01
Pressure actuated Non automatic controller Automatic shutdown
L2
L3
L1480 V 480 V
480 V
23.4A
23.4A
23.4A
90
150
70PSI
VIZITOUCH V2 MAJOR FEATURES INCLUDE:
• Touch screen operation with 7” color display and intuitive graphics
• Multi-language• Upgradable software• Password protected
ConfigHome 26C14:34:282016.Dec.01
Pressure
Periodic test
Advanced
PSI
PT1
Duration (min)
14:09:552016.Dec.01
Cut-in
Cut-out 150
100
Monday
Week. Test
Auto. Shutdown (m)
Date and time
RUN TEST
User login
Duration (min) 10
Duration (min) 10
30
5
7
Max. Pres. 300
2
EventsHistory 26°C14:34:282016.Dec.01
2016.12.01
2016.12.01 Under Voltage: ACTIVE
Under Voltage INACTIVE
2016.12.01 Alarms Reset
2016.12.01
2016.12.01
2016.12.01
2016.12.01
2016.12.01
2016.12.01
2016.12.01
14:28:23
14:28:52
14:28:09
14:09:55
14:11:22
14:03:11
14:08:46
14:03:03
14:12:06
14:28:08 ACB in OFF or Tripped: INACTIVE
Alternate is Tripped/Open: INACTIVE
Control Voltage not Healthy: ACTIVE
Generator: Started
Motor: Started in Automatic
Loss of Power: ACTIVE
Pump On Demand: INACTIVE
ServiceHome 26C14:33:062016.Dec.01
Last service date
Commissionning date
Service interval
Nameplate Information
Jockey pump cut-in
Live view
Jockey pump cut-out
Complete service
Next service due
2016.12.01 14:28:52
2016.12.01 14:28:52
1 year
130
2016.12.01 14:28:52
110
+ 65 6795 8114+ 65 6795 7823
ASIA
+ 32 (0) 1084 4001EUROPE
+ 1 800 363 8448+ 514 334 0523
AMERICAS
+ 971 (0)4 887 0615MIDDLE EAST
Pressure CurvesHistory 26°C14:37:172016.Dec.01
150
120
90
60
30
0
2016.02.2314:24:05
2016.02.2314:25:05
1m 5m 20m 1h 2h 3h 4h 5h 6h 12h 1d 2d 3d 4d 5d 6d 1w 2w
StatisticsFirst Service StatisticsStatistics 26C14:34:282016.Dec.01
First Service Statistics
From
2016.12.01Since
2016.12.01
14:28:09
20
0-00-08-57
14:08:46
99.1 PSI
61-04-08-27On Time
Motor
Start Count
Last Started On
Pressure
Minimum
On Time
SETTINGS
HISTORY/STATISTICS
EVENTS
SERVICE
PUMP CURVES PRESSURE CURVES
ON-SCREEN MENU
Home
Alarm
Configuration
History
Service
Manual
Languages
Pump CurvesHistory 26°C14:37:172016.Dec.01
P
90
68
45
23
01075538 1613 2150 Q 2016.02.23
14:25:05
PMS 295 PMS 361 Noir
®
Home 53C06:45:342016.Dec.01
Non pressure actuated Automatic controller Automatic shutdown
N2
N3
N1
A2
A3
A1
480 V 480 V
480 V
0 V0 V
0 V
480 V 480 V
480 V
23.4A
23.4A
23.4A
MANUAL
0
300
System
70PSI
90110
Electric Fire Pump Controllerwith Automatic Transfer Switch
GPL-SBRO-004-E Rev.0.1
AMERICAS
Tornatech Inc.
Head Office
Laval, Quebec, Canada
Tel: + 1 514 334 0523
Toll free: + 1 800 363 8448
MIDDLE EAST
Tornatech FZE
Dubai, United Arab Emirates
Tel: + 971 (0)4 887 0615
ASIA
Tornatech Pte Ltd.
Singapore
Tel: + 65 6795 8114
Tel: + 65 6795 7823
EUROPE
Tornatech Europe SPRL
Wavre, Belgium
Tel: + 32 (0) 10 84 40 01
Withstand Rating (short circuit current)
208V to 240V - 1ph - 50/60HZ
Normal Power Section Alternate Power Section
Standard 65, 000A
Optional n/a
SHORT CIRCUIT WITHSTAND RATING
THREE PHASE - SHORT CIRCUIT WITHSTAND RATING
HP / VOLTAGE / DIMENSIONS / WEIGHTS
Withstand Rating
(short circuit current)
208V to 240V - 1ph - 50/60HZ 380V to 480V - 3ph - 60HZ 600V - 3ph - 60HZ
Normal Power Section
Alternate Power Section
Normal Power Section
Alternate Power Section
Normal Power Section
Alternate Power Section
Standard 65, 000A 25, 000A 18, 000A
Optional n/a 65, 000A 25, 000A
208V to 240V - 1ph - 50/60HZ
380V to 600V - 3ph - 60HZ GPL GPL + GPU
HP Range (kW) Dimension in inches (mm)
Approx. Shipping Weight in Lbs (Kg)
Dimension in inches (mm)
Approx. Shipping Weight in Lbs (Kg)
5 - 15 (3.7 - 11) 5 - 30 (3.7 - 22)20”w x 24”h x 8”d(508 x 610 x 203)
100(48)
40”w x 24”h x 8”d(1016 x 610 x 203)
250(114)
HOW TO ORDER: GPL - V / HP / Ph / Hz / Options
Ex.: GPA - 208 / 30 / 3 / 60 / Options