Laser Beacon Explaoad View...A2 Treatment : - Checked by : Approved : Date: 08/02/2019 General...
Transcript of Laser Beacon Explaoad View...A2 Treatment : - Checked by : Approved : Date: 08/02/2019 General...
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter :
A2
Treatment : -
Checked by :
Approved :
Date: 08/02/2019
General tolerances :
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
Collège de France11, place Marcelin Berthelot 75231 PARIS cedex 05
XXX0000Ident. EDMS
I-
CF
Laser BeaconExternal Enclosure - Expload view
Laser Beacon Explaoad View
Quartz Rod
Quarrtz Fixing Screws
Quartz Flange
Diffusor
Diffusor Compression Ring
Internal Anti-extrusion Ring
Internal O-ring
External Anti-extrusion Ring
External O-ring
Top Flange Fixing Screws
Top Flange
O ring
O ring
Titanium Cylinder
Connector Nut
Connector Washer
O ring
O ring
Bottom Flange Fixing Screws
Seacon Connector
Bottom Flange
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter :
A2
Treatment : -
Checked by :
Approved :
Date: 08/02/2019
General tolerances :
ISO 2768 mK
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
Collège de France11, place Marcelin Berthelot 75231 PARIS cedex 05
XXX0000Ident. EDMS
I-
CF
Laser BeaconExternal Enclosure
5xFixation Screw M6x35 Ti Gr5
6xFixation Screw M4x14 Ti Gr5
TransparentQuartz Rod
Top Flange
Ti Cylinder
Bottom Flange
Seaconn Connector
A
A
C
C
Coupe A-AEchelle : 1:4
B
D
E
Détail BEchelle : 1:1
Compression joint (Only mechanical function)O-ring 70ShA : Id=21 mm, TD=2mm NBR PB701 (Hutchinson)
Internal axial quartz sealO-ring 90Sh : ID=37.46mm TD=3mmEPDM (9EP2094) (Hutchinson)
External axial quartz sealO-ring 90Sh : ID=73mm TD=4mmEPDM (9EP2094)((Hutchinson)
External back up ringID D=73.09mm PTFE (40% bronze)ref Hutchinson (LJF)
Internal back up ringED=42.90mm PTFE (40% bronze)ref Hutchinson (LJF)
Upper radial enclosure sealO-ring 85ShA : ID=135mm TD=4mmEPDM (EP851) Hutchinson 161400
Lower radial enclosure sealO-ring 85ShA : ID=135mm TD=4mmEPDM (EP851) ref Hutchinson 161400
10DIFF-VISOptical diffuser - NEWPORT
Quartz RodMounting Flange
13.98 14.02
Coupe C-CEchelle : 1:2
23
20.4
1 0.3
Détail DEchelle : 1:1
23
20.4
1 0.3
Détail EEchelle : 1:1
Subconn Connector 12 pinsMCBH-12M 2 O-rings
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter : TA6V
A2
Treatment : -
Checked by :
Approved :
Date: 08/02/2019
General tolerances :
ISO 2768 mK
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
Collège de France11, place Marcelin Berthelot 75231 PARIS cedex 05
XXX0000Ident. EDMS
I-
CF
Laser Beacon Top Flange
84
152.
7
36.8
6xM412mm deepThread 8mm deep
AA
25
50
141.68
+0.05
0
135.88
+0.1
0
D
110
3xM420 mm deepThread 15mm deep
15
36.8
5
Coupe A-AEchelle : 1:2
B
C
78.6 ±0.05
73+0.03
0
38.5 ±0.05
43-0.01
-0.03
28
15
7.32
±0.01
18
5
4
6.52
±0.01
4.2
Détail BEchelle : 1:1
Ra0.4
Ra0.4
E
13
7
12
Détail CEchelle : 1:1
5.1
5.4+0.01
0
5.4+0.01
0
4
2R
2R
Détail DEchelle : 2:1
3.28
20
Détail EEchelle : 2:1
Instead of 4mm
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter : TA6V
A2
Treatment : -
Checked by :
Approved :
Date: 08/02/2019
General tolerances :
ISO 2768 mK
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
Collège de France11, place Marcelin Berthelot 75231 PARIS cedex 05
XXX0000Ident. EDMS
I-
CF
Laser BeaconTitanium Cylinder
152.7
Vue de faceEchelle : 1:2
5xM6Hole 23mm deepThread 21mm deep
A
A
135
163
5 40
142.4
+0.03
+0.02
142.4
+0.03
+0.02
Coupe A-AEchelle : 1:2R
a0.4
Ra0.4
D E
152.7
Vue auxiliaire BEchelle : 1:2
5xM6Hole 23mm deepThread 21mm deep
135
2R 2R23
Détail DEchelle : 2:1
Ra0.4
135
23
2R
2R
Détail EEchelle : 2:1
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter : TA6V
A2
Treatment : -
Checked by :
Approved :
Date: 08/02/2019
General tolerances :
ISO 2768 mK
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
Collège de France11, place Marcelin Berthelot 75231 PARIS cedex 05
XXX0000Ident. EDMS
I-
CF
Laser BeaconORCA Bottom Flange
152.75xM5Hole 12mm deep
A
A
50
25
5.4
5.4
5.1
4
2R
141.68
+0.05
0
135.88
+0.1
0
172
80
12
12
38
14.02
+0.03
0
40
13 7
Coupe A-AEchelle : 1:2
B
12.7
14.02
+0.03
0
Détail BEchelle : 2:1
32
32
C
1.27
15
Détail CEchelle : 4:1
Vue isométriqueEchelle : 1:2
Vue isométriqueEchelle : 1:2
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter : TA6V
A2
Treatment : -
Checked by :
Approved :
Date: 08/02/2019
General tolerances :
ISO 2768 mK
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
Collège de France11, place Marcelin Berthelot 75231 PARIS cedex 05
XXX0000Ident. EDMS
I-
CF
Laser Beacon ARCA Bottom Flange
152.7
48
6xM520 mm deep
5xM5Hole 12mm deep
A
A
141.68
+0.05
0
135.88
+0.1
0
172
5 .45.4
2R
5.1
4
50
20
12
12
7
13
32H8
38
4.13
4.13
3 5
Coupe A-AEchelle : 1:2
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter :
A2
Treatment : -
Checked by :
Approved :
Date: 08/02/2019
General tolerances :
ISO 2768 mK
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
10, rue Alice Domon et Léonie Duquet75013 Paris
XXX0000Ident. EDMS
I-
CF
Laser BeaconCylinder Sealing
A
A
Coupe A-AEchelle : 1:2
BC
141.68
+0.05
0
142.4
+0.03
+0.02
135.88
+0.1
0
5.4
5.4
Détail BEchelle : 2:1
Lower radial enclosure seal0-ring 85ShA : ID=135mm TD=4mmEPDM (EP851) Hutchinson 161400
Lower radial enclosure seal0-ring 85ShA : ID=135mm TD=4mmEPDM (EP851) Hutchinson 161400
141.68
+0.5
0
142.4
+0.03
+0.02
135.88
+0.1
0
5.4
5.4
Détail CEchelle : 2:1
Water pressure
350 bars
Atmosferic pressure
Laser BeaconCylinder Sealing
Upper radial enclosure seal0-ring 85ShA : ID=135mm TD=4mmEPDM (EP851) Hutchinson 161400
Lower radial enclosure seal0-ring 85ShA : ID=135mm TD=4mmEPDM (EP851) Hutchinson 161400
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter :
A2
Treatment : -
Checked by :
Approved :
Date: 08/02/2019
General tolerances :
ISO 2768 mK
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
Collège de France11, place Marcelin Berthelot 75231 PARIS cedex 05
XXX0000Ident. EDMS
I-
CF
Laser BeaconInternal mechanics - Expload view
Laser Beacon Internal Mechanics
Top mounting cylinder
Bolt M4x20 + Washer
Mounting plate
Bolt M4x20 + Washer
LPMI+ support plate
Bolt M4x20 + Washer
Bolt M4x20 + Washer
Bolt M4x20 + Washer
Dissipative spacer 4.5mm
Thermal pad
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter :
A2
Treatment : -
Checked by :
Approved :
Date: 02/05/2019
General tolerances :
ISO 2768 mk
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
Collège de France11, place Marcelin Berthelot 75231 PARIS cedex 05
XXX0000Ident. EDMS
I-
CF
Laser BeaconInternal Structure Assembly
Laser Beacon Internal Assembly
A
A
Coupe A-AEchelle : 2:5
B
B
E
F
G
Coupe B-BEchelle : 2:5
C
D
9.2
Détail CEchelle : 1:1
15.2
Détail DEchelle : 1:1
10.2
Détail EEchelle : 1:1
5+0.01
0(H7)
5-0.01
-0.03(g6)
5+0.01
0(H7)
Détail FEchelle : 4:5
Centering pin
30+0.03
0(H7)
30-0.01
-0.03g6
10-0.01
-0.03
10+0.03
0
5+0.25
+0.1
Détail GEchelle : 4:5
Bumper
Rubber - Shocks absorber
Mounting plate
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter : Alu
A2
Treatment : -
Checked by :
Approved :
Date: 08/02/2019
General tolerances :
ISO 2768 mK
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
Collège de France11, place Marcelin Berthelot 75231 PARIS cedex 05
XXX0000Ident. EDMS
I-
CF
Laser Beacon Mounting Plate
120
400
20
R
20R
20
R
20
R5050
20 20 204530
50 50
25
24
20
80
205
80
150
30
10
10R
10
R
10R10
R
150 30
3.54x
4xM4
M3
M3
M3
A
A
BB 6
1 451 45
10
Coupe A-A
5
M4x0.715mm deep
M4x0.715mm deep
145
145
145
15 Coupe B-BEchelle : 2:3
30
45 20 20 20
6 6 6 6
130
60
42.4
8.9
32.3
3 9.8
108
35
25.5
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :Alin ILIONI
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Material : Alu
A2
Treatment :
Checked by :
Approved :
Date: 2018/10/19
General tolerances :
ISO 2768 mK
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
10, rue Alice Domon et Léonie Duquet 75205 Paris Cedex 13
XXX0000Atrium ID
CF
LASER BEACONTop mounting plate support
50 50
120
120
25
27
5
5
5
12
3x Depth 6mm
5
10
25.4
Front viewScale: 1:1
35
20
10
345
2 45
10
4510
Left viewScale: 1:1
25
4
10
25
5.7
1 33
Top viewScale: 1:1
110
5050
25
27
120
120
10
5
12Depth 15mm
12
Depth 15mm
55
Back viewScale: 1:1
Isometric viewScale: 1:1
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :Alin ILIONI
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Material : Alu
A2
Treatment :
Checked by :
Approved :
Date: 2017/05/10
General tolerances :
ISO 2768 mK
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
10, rue Alice Domon et Léonie Duquet 75205 Paris Cedex 13
XXX0000Atrium ID
CF
LASER BEACONBottom mounting plate support
5
20
20
20
20
5 0
50
35
35
35
35
5
Vue de faceEchelle : 1:1
A A
45
5
20
10
5
10
133
Vue de gaucheEchelle : 1:1
30
50 5012
Dept
h 6m
m
12
Depth 6m
m
Vue de derrièreEchelle : 1:1
45
1
45
1
Coupe A-AEchelle : 1:1
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter : Alu
A2
Treatment : -
Checked by :
Approved :
Date: 08/02/2019
General tolerances :ISO 2768 mk
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
Collège de France11, place Marcelin Berthelot 75231 PARIS cedex 05
XXX0000Ident. EDMS
I-
CF
Laser Beacon Bumper
5
28
30
70
A
A 10
2 45
1 45
10
Coupe A-AEchelle : 2:1
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter : Alu
A2
Treatment : -
Checked by :
Approved :
Date: 08/02/2019
General tolerances :
ISO 2768 mK
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
Collège de France11, place Marcelin Berthelot 75231 PARIS cedex 05
XXX0000Ident. EDMS
I-
CF
Laser BeaconCentering Pin
50
2 45
2 45
5-0.4
-0.12(g6)
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter : Alu
A2
Treatment : -
Checked by :
Approved :
Date: 08/02/2019
General tolerances :
ISO 2768 mK
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
Collège de France11, place Marcelin Berthelot 75231 PARIS cedex 05
XXX0000Ident. EDMS
I-
CF
Laser BeaconLPMI Support
180
115
15
7.5
54x
9
48
7.5
7.5
1 5
15 15
7.5
9
10R
10
R
10
R
10R
A A
B
B
D
D
15
175
10
10
66
8
Coupe B-BEchelle : 1:1
3030
30 30 35
19.5
19.5
3 5
35
19.5
19.5
3 5
3R 3
R
3R
3R
3R
3R
3R
3R
5
12
5
12
5
Coupe D-DEchelle : 1:1
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter : Quartz GE124
A2
Treatment : -
Checked by :
Approved :
Date: 08/02/2019
General tolerances :
ISO 2768 mK
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
Collège de France11, place Marcelin Berthelot 75231 PARIS cedex 05
XXX0000Ident. EDMS
I-
CF
Laser Beacon Quartz Rod
73
-0.01
-0.04
43
+0.03
0
15
6318
2R19
20
4
3
60
Red surfaces to be polished at minimum defined quality
Blue surfaces to be painted (black epoxy paint)
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter : TA6V
A2
Treatment : -
Checked by :
Approved :
Date: 08/02/2019
General tolerances :
ISO 2768 mK
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
Collège de France11, place Marcelin Berthelot 75231 PARIS cedex 05
XXX0000Ident. EDMS
I-
CF
Laser BeaconQuartz Rod Flange
84
82 Hexagon
64
2 30
A
A
3
Coupe A-AEchelle : 2:1
B
1 451 45
5
Détail BEchelle : 4:1
H G
DE CF BG AH
54
5
4
63
6
3
72
7
2
81
8
1
Quantity : 1
Date
Drawn by :A. Ilioni
Uses and Communicationsforbidden
without written authorization1/1
ModificationIndice
Surface state Ra = 3,2
Except contrary indication
Matter :
A2
Treatment : -
Checked by :
Approved :
Date: 08/02/2019
General tolerances :
ISO 2768 mK
Rev
00
Scale1:1
AB
ASTRO P ARTICULE et COSMOLOGIE
10, rue Alice Domon et Léonie Duquet75013 Paris
XXX0000Ident. EDMS
I-
CF
Laser BeaconQuartz Rod SealingAA
73+0.03
0
73-0.01
-0.04
43+0.03
0
43-0.01
-0.03
38.5 ±0.05
78.6 ±0.05
6.52
±0.1
7.32
±0.1
Coupe A-AEchelle : 2:1
External axial quartz sealO-ring 90Sh : ID=73mm TD=4mmEPDM (9EP2094)((Hutchinson)
External back up ringID D=73.09mm PTFE (40% bronze)ref Hutchinson (LJF)
Quarz Rod
Titanium Top Flange
Internal back up ringED=42.90mm PTFE (40% bronze)ref Hutchinson (LJF)
Internal axial quartz sealO-ring : ID=37.46mm TD=3mmEPDM 90Sh - Hutchinson
Laser Beacon Quartz Rod Sealing
350 bars
350 bars
Atmospheric
pressure
Compression joint(Only mechanical function)O-ring 70ShA: ID=21mm, TD=2mmNBR PB701 (Hutchinson)
Water pressure