Chromasun Micro-Concentrator
![Page 2: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/2.jpg)
Andrew Tanner PAGE 2
What is Solar Thermal?
![Page 3: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/3.jpg)
Andrew Tanner PAGE 3
Solar Hot Water Heating
• Solar Hot Water heating
uses the heat of the sun
to generate hot water
• Flat panels like the ones
shown to the right can
efficiently generate
temperatures of 120F
but beyond that they
lose efficiency rapidly
![Page 4: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/4.jpg)
Andrew Tanner PAGE 4
What is Concentrating
Solar Thermal?
![Page 5: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/5.jpg)
Andrew Tanner PAGE 5
Concentrating Solar Thermal
• Concentrating solar
thermal uses reflectors
to actively track the sun
and concentrate the heat
onto an absorber pipe
• The reduced surface
area of the absorber
pipe means that these
types of collectors are
still efficient at
temperatures over 200F
![Page 6: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/6.jpg)
Andrew Tanner PAGE 6
Why Chromasun?
![Page 7: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/7.jpg)
Andrew Tanner PAGE 7
Solar Experience
• Peter Le Lievre (CEO) and Andrew Tanner (VP of Engineering) were founding engineers at Ausra, now
Areva Renewables. Between 2002 and 2008 built Australia’s largest solar thermal power plant and designed
Germany’s largest. They have applied this knowledge to design and build the Chromasun MCT.
![Page 8: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/8.jpg)
Andrew Tanner PAGE 8
2008 Chromasun Formed
Objective: miniaturize the
known linear Fresnel optic
that they pioneered with
Ausra and make it into a
building friendly product
200X Reduction in size!
![Page 9: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/9.jpg)
Andrew Tanner PAGE 9
MCT Exploded View
Receiver Pipe (SS 304 A213 Tube)
Parallel Mirrors
The MCT is fixed on the rooftop like a regular panel however
20 parallel mirrors internally track the sun to provide 20X
concentration onto a stainless steel receiver pipe
MCT Tracking Video
![Page 10: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/10.jpg)
Andrew Tanner PAGE 10
Best in Class Solar Collector
Highest
temperature rated
solar collector in
the USA
(179ºC /354ºF)
![Page 11: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/11.jpg)
Andrew Tanner PAGE 11
Why is the MCT the superior concentrator?
• Easy to install
• Closed loop plug-and-play
approach to tracking
• No external moving parts
• Reduced wind-loadings
• Reduced roof loadings (<5lb/sqft)
• Aesthetically stunning
• Easy to clean
• External tracking mechanisms
• Dependent on algorithms to track
• Reflective surface is prone to
abrasive damage over time
• Catches the dirt and hard to clean
• Lower roof packing density due to
shading
• Complex roof loadings
vs
![Page 12: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/12.jpg)
Andrew Tanner PAGE 12
How does the MCT install?
![Page 13: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/13.jpg)
Andrew Tanner PAGE 13
Chromasun MCT – Simple Installation
MCT is self-supporting and has an integrated stand that has seismic and
structural sign-off to hurricane loadings
![Page 14: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/14.jpg)
Andrew Tanner PAGE 14
Chromasun MCT – Simple Installation
The picking points and integrated racking makes installation on the rooftop
simple and efficient.
![Page 15: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/15.jpg)
MCT Installation Video
![Page 16: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/16.jpg)
Andrew Tanner PAGE 16
Where have they deployed
the technology before?
![Page 17: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/17.jpg)
Andrew Tanner PAGE 17
Santa Clara University Showcase Project
![Page 18: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/18.jpg)
Andrew Tanner PAGE 18
Santa Clara University Showcase Project
![Page 19: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/19.jpg)
Andrew Tanner PAGE 19
SCU Benson System Schematic
Simple plate exchanger
takes the 200F heat from
the MCT’s and delivers it to
the building loop
![Page 20: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/20.jpg)
Andrew Tanner PAGE 20
SCU Solar Monitoring
Solar Monitoring Equipment was installed so that output could be modeled
![Page 21: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/21.jpg)
Andrew Tanner PAGE 21
SCU BTU Energy Metering
BTU Metering was installed so that output could be measured
![Page 22: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/22.jpg)
Andrew Tanner PAGE 22
SCU Performance
• Monitoring equipment enables
comparison of metered data with
modeled data
• For this project measured and
modeled have aligned perfectly!
![Page 23: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/23.jpg)
Andrew Tanner PAGE 23
What if I have a steam
requirement?
![Page 24: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/24.jpg)
Andrew Tanner PAGE 24
Industrial Process Heat Applications
![Page 25: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/25.jpg)
Andrew Tanner PAGE 25
Solution for baseload
cooling?
![Page 26: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/26.jpg)
Andrew Tanner PAGE 26
Cooling with MCT’s and a Double Effect Absorption Chiller
HHW
MCT Panels
DE Multi-Fire Absorption Chiller Cool Building
Sunlight
Heat Rejection
1.35 @ 7ºC / 44ºF
2.35 @ 30ºC / 85ºF
1 @ 175ºC / 350ºF and/or Natural Gas
CHW CW
![Page 27: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/27.jpg)
Andrew Tanner PAGE 27
Roof Area Utilization
An MCT array in conjunction with a two-stage absorption
chiller is best in class for rooftop area utilization
![Page 28: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/28.jpg)
Andrew Tanner PAGE 28
Solution for baseload
domestic hot water
&cooling?
![Page 29: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/29.jpg)
Andrew Tanner PAGE 29
Solar Heating & Cooling with MCT Panels
The MCT’s unique ability to efficiently deliver thermal energy over 200F
makes it ideal for integration with absorption chillers / heat pumps
1.6 times as
much heat out!!
![Page 30: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/30.jpg)
Andrew Tanner PAGE 30
Solar Heat & Cooling System Configuration
• This “Solar Cooling” design gets the Federal 30% rebate (including the aux boiler!)
• CSI State Rebate on Solar and Energy Efficiency rebate on the boiler skid
• Chromasun can finance the entire system and attain a payback through both solar
and the 150% efficient boiler
![Page 31: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/31.jpg)
Andrew Tanner PAGE 31
Example Chiller at Poultry Farm in CA
Compact Skid!
![Page 32: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/32.jpg)
Andrew Tanner PAGE 32
Rooftop solar energy yields for the building
0
50
100
150
200
250
300
350
400
Flat Plate DHW Flat Plate CHW PhotovoltaicCHW
MCT CHW MCT DHW +CHW
BT
U/s
qu
are
feet
roo
f are
a
Solar technology type
CHW
DHW
Best building
energy outcome!
The Chromasun MCT with the heat pump therefore delivers more energy for
a rooftop area than any other solar technology
![Page 33: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/33.jpg)
Andrew Tanner PAGE 33
What if I have a high
latent/dehumidification load?
![Page 34: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/34.jpg)
Andrew Tanner PAGE 34
Traditional Cooling Tem
p
“Summer” Boiler
Humidity removal by condensation
44ºF/
7ºC
65ºF/
18ºC
“cause that’s how we’ve always done it”
Over-chilling by
electrical vapor
compression
SENSIBLE
+ LATENT
![Page 35: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/35.jpg)
Andrew Tanner PAGE 35
Latent Heat Removal with Desiccants Tem
p
Humidity removal by
desiccant (solid or liquid) that
can then be regenerated by
solar thermal
65ºF/
18ºC
Significantly reduced net
chilling by electrical
vapor compression and
no lover over-chilling
LATENT
SENSIBLE
Solar
regenerates the
desiccant
![Page 36: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/36.jpg)
Andrew Tanner PAGE 36
How are these projects
financed?
![Page 37: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/37.jpg)
Andrew Tanner PAGE 37
2011 – The year for Solar Thermal!!
• In 2011, the following incentives are available to offset the cost
– 30% Federal Investment Tax Credit as a GRANT
– 100% Bonus Depreciation at the end of Year 1 WORTH 30%
– California Solar Initiative Thermal Rebate is at Tier 1 and WORTH APPROX
20%
• In 2012, the incentives reduce to the following
– 30% Federal Investment Tax Credit as a TAX CREDIT
– 50% Bonus Depreciation at the end of Year 1 WORTH 15%
– California Solar Initiative Thermal Rebate will likely drop to Tier 2 and
WORTH APPROX 10%
![Page 38: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/38.jpg)
Andrew Tanner PAGE 38
Project Financing
$-
$0.20
$0.40
$0.60
$0.80
$1.00
$1.20
$1.40
$1.60
$1.80
Feb-1
982
Ap
r-1
98
4
Ju
l-1
98
6
Se
p-1
98
8
No
v-1
99
0
Ja
n-1
99
3
Ap
r-1
99
5
Ju
n-1
99
7
Au
g-1
99
9
No
v-2
00
1
Ja
n-2
00
4
Mar-
2006
Ju
n-2
00
8
Au
g-2
01
0
Oct-
201
2
$/t
herm
Historical Natural Gas Price
9.5%
?
• Chromasun is able to fully
finance projects as: – Finance Lease
– Thermal Power Purchasing Agreement
• Finance Lease – Fixed Monthly Rate
– Performance Guarantees
• Thermal PPA – Thermal Energy is metered and
charged to the customer at a rate
below what it costs to produce it from
gas (nominally 10%). I.e. Always
saving!
– 10, 15 or 20yr terms
– O&M remains responsibility of
Chromasun
![Page 39: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/39.jpg)
Andrew Tanner PAGE 39
Where do they
manufacture?
![Page 40: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/40.jpg)
Andrew Tanner PAGE 40
Chromasun 10MW / Annum San Jose facility
Chromasun MCT are made
in the USA
![Page 41: Introduction to Chromasun MCT](https://reader031.fdocuments.in/reader031/viewer/2022013123/5885bd221a28ab466d8bac76/html5/thumbnails/41.jpg)
Andrew Tanner PAGE 41
MCT Summary
• Chromasun MCT is based on existing CSP technology and over a decade
of experience in large-scale solar
• Highest Temperature rated SRCC collector in the US
• Concentrating the sun’s energy enables the MCT to consistently deliver up
to 220ºC (440ºF) on the rooftop
• MCT has no externally moving parts, reducing O&M
• Unlike other concentrating technologies, cleaning is limited to flat glass
(automated cleaning system in development)
• MCT can be turned on a off which provides safe operation
• MCT is a durable, industrial grade product with sturdy installation method
• The delivery of higher grade heat enables compatibility with absorption
chillers and thermally driven heat pumps
• Project financing available through Chromasun