Ifm the Right Choice for Your Application Level Sensors From Ifm

download Ifm the Right Choice for Your Application Level Sensors From Ifm

of 10

Transcript of Ifm the Right Choice for Your Application Level Sensors From Ifm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    1/24

    The right choicefor your application.Level sensors

    from ifm.

      w  w  w .   i

       f  m .  c  o  m

       L  e  v  e   l  s  e  n  s  o  r  s

     y ea r s

       W A  R

     RAN T  Y  

    o  n   

    i  f  m  p r o d   u

       c     t    s

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    2/24

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    3/243

       I  m  p  e   d  a  n  c  e

      s  p  e  c   t  r  o  s  c  o  p  y

      S  e  n  s  o  r

       t  y  p  e

       M  a  x

     .   m  e  a

      s  u  r   i  n

      g    r  a  n  g 

      e    [   c  m   ] 

      A  n  a   l  o  g   u

      e   o  u  t  p  u

      t

    4 - 5 LMT –

    EHEDG3A

    FDAEC1935WHGATEX

       C  a  p  a  c   i   t   i  v  e   i  n

      c  o  n   t  a  c   t  w   i   t   h

       t   h  e  m  e   d   i  u  m

    6 - 7 LI – WHG

       C  a  p  a  c   i   t   i  v  e

      w   i   t   h  o  u   t

      c  o  n   t  a  c   t

    8 - 9KG, KI, KQ –

       C  a  p  a  c   i   t   i  v  e

      c  o  n   t   i  n  u  o  u  s

    10-11LK, LT 73 WHG

       G  u   i   d  e   d

      w  a  v  e  r  a   d  a  r

    12-15 LR 200

    EHEDG3A

    FDAEC1935WHG

       H  y   d  r  o  s   t  a   t   i  c

    16-19PG, PI,

    PA, PS, PN–

    EHEDG3A

    FDAEC1935ATEX

       P   h  o   t  o  e   l  e  c   t  r   i  c

     20-21O1D 980

       A  c  c  e  s  s  o  r   i  e  s

     22-23

      S  w   i  t  c   h   i  n

      g    o  u

      t  p  u  t

      A

      p  p  r  o  v  a   l  s

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    4/24

    G 1/2 11 LMT100 LMT191 –

    Reliable detection:

    Suppression of residues,splashing water or foam.

    Better than a tuning fork:No mechanical components, fully

    compatible regarding installation

    and function.

    Immediately ready for use:Factory settings for the

    most common media.

    Adaptable using IO-Link:Adaptation to and differentiation

    of media configurable.

    More transparency:Read process values to optimise

    the application.

    Hygienic design:

    High-grade stainless steelhousing with PEEK sensor tip

    and maintenance-free sealing

    concept.

    4

    For hygienic areasand viscous media

    Type LMT 

    level sensor

    Flexible mounting

    thanks to orienta-

    tion-independent 

    installation.

    Shock and vibra-

    tion resistant in a

    robust stainless

     steel housing.

    Hygienic approvals

    EHEDG, 3A and 

    FDA.

    Versions available

    as overflow 

     protection.

    Complementary 

     switching outputs.

    Processconnection

    Installationlength[mm]

    Order no. Order no. Order no.

    Approvals

    Preset to aqueous media

    Hygienic WHG* ATEX

    G 1/2 38 LMT102 LMT192 –

    G 1/2 153 LMT104 LMT194 –

    G 1/2 253 LMT105 LMT195 –

    G 3/4 28 LMT202 LMT292 –

    G 1 38 LMT302 LMT392 –

    G 1/2 11 LMT110 – –

    Preset to oils, fats, powder

    G 1/2 11 LMT121 – –

    Preset to sugary media

    G 1/2 11 – – LMT01A

    G 1/2 153 – – LMT03A

    G 1/2 253 – – LMT04A

    * German Federal Water Act

    http://www.ifm.com/products/gb/ds/LMT100.htmhttp://www.ifm.com/products/gb/ds/LMT191.htmhttp://www.ifm.com/products/gb/ds/LMT102.htmhttp://www.ifm.com/products/gb/ds/LMT192.htmhttp://www.ifm.com/products/gb/ds/LMT104.htmhttp://www.ifm.com/products/gb/ds/LMT194.htmhttp://www.ifm.com/products/gb/ds/LMT105.htmhttp://www.ifm.com/products/gb/ds/LMT195.htmhttp://www.ifm.com/products/gb/ds/LMT202.htmhttp://www.ifm.com/products/gb/ds/LMT292.htmhttp://www.ifm.com/products/gb/ds/LMT302.htmhttp://www.ifm.com/products/gb/ds/LMT392.htmhttp://www.ifm.com/products/gb/ds/LMT110.htmhttp://www.ifm.com/products/gb/ds/LMT121.htmhttp://www.ifm.com/products/gb/ds/LMT01A.htmhttp://www.ifm.com/products/gb/ds/LMT03A.htmhttp://www.ifm.com/products/gb/ds/LMT04A.htmhttp://www.ifm.com/products/gb/ds/LMT04A.htmhttp://www.ifm.com/products/gb/ds/LMT03A.htmhttp://www.ifm.com/products/gb/ds/LMT01A.htmhttp://www.ifm.com/products/gb/ds/LMT121.htmhttp://www.ifm.com/products/gb/ds/LMT110.htmhttp://www.ifm.com/products/gb/ds/LMT392.htmhttp://www.ifm.com/products/gb/ds/LMT302.htmhttp://www.ifm.com/products/gb/ds/LMT292.htmhttp://www.ifm.com/products/gb/ds/LMT202.htmhttp://www.ifm.com/products/gb/ds/LMT195.htmhttp://www.ifm.com/products/gb/ds/LMT105.htmhttp://www.ifm.com/products/gb/ds/LMT194.htmhttp://www.ifm.com/products/gb/ds/LMT104.htmhttp://www.ifm.com/products/gb/ds/LMT192.htmhttp://www.ifm.com/products/gb/ds/LMT102.htmhttp://www.ifm.com/products/gb/ds/LMT191.htmhttp://www.ifm.com/products/gb/ds/LMT100.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    5/24

    Manhole

    monitoring

    Full 

    monitoring

    Empty 

    monitoring

    Run-dry 

     protection

    Point level detection with impedance spectroscopy.The reliable and fast alternative to tuning forks.

       I  m  p  e   d  a  n  c  e

      s  p  e  c   t  r  o  s  c  o  p  y

       C  a  p  a  c   i   t   i  v  e   i  n

      c  o  n   t  a  c   t  w   i   t   h

       t   h  e  m  e   d   i  u  m

       C  a  p  a  c   i   t   i  v  e

      w   i   t   h  o  u   t

      c  o  n   t  a  c   t

       C  a  p  a  c   i   t   i  v  e

      c  o  n   t   i  n  u  o  u  s

       G  u   i   d  e   d

      w  a  v  e  r  a   d  a  r

       H  y   d  r  o  s   t  a   t   i  c

       P   h  o   t  o  e   l  e  c   t  r   i  c

       A  c  c  e  s  s  o  r   i  e  sFor adapters

     see pages

     22 - 23

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    6/24

    Ready in no time:Easy mounting adjustment.

    Flexible:Normally closed / normally open

    programmable.

    Clear:Clearly visible indication of

    the switch points.

    Variable use:Installation depths of

    132 to 737 mm.

    Certified:Approval as overflow protection

    or leakage sensor to the

    German Federal Water Act.

    For industrial applications

    Type LI 

     point level sensor 

    Optimised for use

    in hydraulic oils

    and coolants.

    Modular mount-

    ing concept for 

    flexible use.

    It only takes one

     push of a button

    to adjust and 

     set the output 

    function.

    132 0...35 (0...65)1) 0...65 LI5141

    Rod length

    [mm]

    Watertemperature

    [°C]

    Oiltemperature

    [°C]

    Order no.

    1 switching output, normally closed / normally open programmable

    1 switching output, normally closed

    Overflow protection to the WHG*

    273 0...35 (0...65)1) 0...65 LI5142

    481 0...35 (0...65)1) 0...65 LI5143

    737 0...35 (0...65)1) 0...65 LI5144

    132 0...35 0...65 LI2141

    273 0...35 0...65 LI2142

    481 0...35 0...65 LI2143

    Leakage sensor to the WHG*

    132 0...35 0...65 LI2241

    273 0...35 0...65 LI2242

    481 0...35 0...65 LI2243

    *

    German Federal Water Act1) in connection with climatic tube, see accessories page 23

    http://www.ifm.com/products/gb/ds/LI5141.htmhttp://www.ifm.com/products/gb/ds/LI5142.htmhttp://www.ifm.com/products/gb/ds/LI5143.htmhttp://www.ifm.com/products/gb/ds/LI5144.htmhttp://www.ifm.com/products/gb/ds/LI2141.htmhttp://www.ifm.com/products/gb/ds/LI2142.htmhttp://www.ifm.com/products/gb/ds/LI2143.htmhttp://www.ifm.com/products/gb/ds/LI2241.htmhttp://www.ifm.com/products/gb/ds/LI2242.htmhttp://www.ifm.com/products/gb/ds/LI2243.htmhttp://www.ifm.com/products/gb/ds/LI2243.htmhttp://www.ifm.com/products/gb/ds/LI2242.htmhttp://www.ifm.com/products/gb/ds/LI2241.htmhttp://www.ifm.com/products/gb/ds/LI2143.htmhttp://www.ifm.com/products/gb/ds/LI2142.htmhttp://www.ifm.com/products/gb/ds/LI2141.htmhttp://www.ifm.com/products/gb/ds/LI5144.htmhttp://www.ifm.com/products/gb/ds/LI5143.htmhttp://www.ifm.com/products/gb/ds/LI5142.htmhttp://www.ifm.com/products/gb/ds/LI5141.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    7/24

    Capacitive point level.In contact with the medium –protection against overflow and leakage.

    Order no w.

     0 8 0 0 16 16 16  4 or

     in  t he e - s hop a t

     w w w. i fm.com

       I  m  p  e   d  a  n  c  e

      s  p  e  c   t  r  o  s  c  o  p  y

       C  a  p  a  c   i   t   i  v  e   i  n

      c  o  n   t  a  c   t  w   i   t   h

       t   h  e  m  e   d   i  u  m

       C  a  p  a  c   i   t   i  v  e

      w   i   t   h  o  u   t

      c  o  n   t  a  c   t

       C  a  p  a  c   i   t   i  v  e

      c  o  n   t   i  n  u  o  u  s

       G  u   i   d  e   d

      w  a  v  e  r  a   d  a  r

       H  y   d  r  o  s   t  a   t   i  c

       P   h  o   t  o  e   l  e  c   t  r   i  c

       A  c  c  e  s  s  o  r   i  e  sFor adapters

     see pages

     22 - 23

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    8/24

    Convenient:

    Many functions such as binaryswitching output, timer functions

    as output, damping function as

    well as NC / NO function.

    Communicative:Process values, parameter setting

    data and diagnostic information

    can be transmitted via IO-Link.

    Easy:Parameter setting via IO-Link

    before installation, as an alter-

    native also via pushbuttons on

    the sensor.

    Repeatable:Simple parameter setting of

    many sensors via “copy & paste”

    in the LINERRECORDER SENSOR

    software or via a memory plug.

    Clear:Clearly visible LEDs indicate the

    switching status.

    Type KG / KI 

     point level sensors

    Capacitive sensors

    in cylindrical M18 

    or M30 housing.

    For industrial applications

    8 nf Cable • KG50691)

    Sensingrange[mm]

    Connection Teachfunction

    Order no.

    DC PNP

    M18 housing, plastic

    15 nfM12

    connector– KI5052

    M30 housing, plastic

    20 nfM12

    connector• KI5083

    8 fM12

    connector• KI5085

    M30 housing, metal

    15 nfM12

    connector• KI5087

    8 nfM12

    connector

    – KG5057

    • KG5071

    12 nfM12

    connector• KG5066

    1)Housing, white PPf: flush installation nf: non-flush installation

    http://www.ifm.com/products/gb/ds/KG5069.htmhttp://www.ifm.com/products/gb/ds/KG5069.htmhttp://www.ifm.com/products/gb/ds/KI5052.htmhttp://www.ifm.com/products/gb/ds/KI5083.htmhttp://www.ifm.com/products/gb/ds/KI5085.htmhttp://www.ifm.com/products/gb/ds/KI5087.htmhttp://www.ifm.com/products/gb/ds/KG5057.htmhttp://www.ifm.com/products/gb/ds/KG5071.htmhttp://www.ifm.com/products/gb/ds/KG5066.htmhttp://www.ifm.com/products/gb/ds/KG5066.htmhttp://www.ifm.com/products/gb/ds/KG5071.htmhttp://www.ifm.com/products/gb/ds/KG5057.htmhttp://www.ifm.com/products/gb/ds/KI5087.htmhttp://www.ifm.com/products/gb/ds/KI5085.htmhttp://www.ifm.com/products/gb/ds/KI5083.htmhttp://www.ifm.com/products/gb/ds/KI5052.htmhttp://www.ifm.com/products/gb/ds/KG5069.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    9/249

    Capacitive point level.Detection through non-metallic tank walls.

       I  m  p  e   d  a  n  c  e

      s  p  e  c   t  r  o  s  c  o  p  y

       C  a  p  a  c   i   t   i  v  e   i  n

      c  o  n   t  a  c   t  w   i   t   h

       t   h  e  m  e   d   i  u  m

       C  a  p  a  c   i   t   i  v  e

      w   i   t   h  o  u   t

      c  o  n   t  a  c   t

       C  a  p  a  c   i   t   i  v  e

      c  o  n   t   i  n  u  o  u  s

       G  u   i   d  e   d

      w  a  v  e  r  a   d  a  r

       H  y   d  r  o  s   t  a   t   i  c

       P   h  o   t  o  e   l  e  c   t  r   i  c

       A  c  c  e  s  s  o  r   i  e  s

    Sensingrange[mm]

    Connection Order no.

    DC PNP

    12 nfCable 2 m KQ6002

    Cable 10 m KQ6007

    12 nf

    Cable plug

    M8   KQ6004

    12 nfCable plug

    M12  KQ6005

    Type KQ

    point level sensor 

    Capacitive sensors

    in small plastic 

    rectangular 

    housing.

    Easy installation

    with mounting

    adapters and 

    fixing straps.

    DC NPN

    12 nf

    12 nf

    Cable 2 m KQ6006

    Cable plugM12

    KQ6016

    DC PNP

    12 nf

    12 nf

    Cable 2 m KQ5100

    Cable plugM12

    KQ5101

    12 nfCable plug

    M8KQ5102

    f: flush installation nf: non-flush installation

    http://www.ifm.com/products/gb/ds/KQ6002.htmhttp://www.ifm.com/products/gb/ds/KQ6007.htmhttp://www.ifm.com/products/gb/ds/KQ6004.htmhttp://www.ifm.com/products/gb/ds/KQ6005.htmhttp://www.ifm.com/products/gb/ds/KQ6005.htmhttp://www.ifm.com/products/gb/ds/KQ6006.htmhttp://www.ifm.com/products/gb/ds/KQ6016.htmhttp://www.ifm.com/products/gb/ds/KQ5100.htmhttp://www.ifm.com/products/gb/ds/KQ5101.htmhttp://www.ifm.com/products/gb/ds/KQ5102.htmhttp://www.ifm.com/products/gb/ds/KQ5102.htmhttp://www.ifm.com/products/gb/ds/KQ5101.htmhttp://www.ifm.com/products/gb/ds/KQ5100.htmhttp://www.ifm.com/products/gb/ds/KQ6016.htmhttp://www.ifm.com/products/gb/ds/KQ6006.htmhttp://www.ifm.com/products/gb/ds/KQ6005.htmhttp://www.ifm.com/products/gb/ds/KQ6004.htmhttp://www.ifm.com/products/gb/ds/KQ6007.htmhttp://www.ifm.com/products/gb/ds/KQ6002.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    10/24

    Professional:For industrial applications.

    Manifold:Versions with 2 or 4 switching

    outputs or analogue output

    4...20 mA / 0...10 V.

    Safe:Type LK12 with approval as

    overflow protection.

    Combined:Type LT for level and temperature

    monitoring.

    Type LK 

    level sensor 

    Display and hand-

    ling directly on

    the unit.

     As an option with

    analogue output 

    or up to four 

     switching outputs.

    Suitable for oil 

    temperatures up

    to 70 °C.

    Versions to the

    German Federal 

    Water Act 

    available.

    For industrial applications

    264 LK1022

    Rod length

    [mm]

    Version Order no.

    2 switching outputs

    1 switching output, 1 analogue output 4...20 mA, 0...10 V

    472 LK1023

    728 LK1024

    264 WHG* LK1222

    472 WHG* LK1223

    728 WHG* LK1224

    10

    264 LK3122

    472 LK3123

    728 LK3124

    2 switching outputs

    264Automatic

    medium detection

    LK7022

    472 LK7023

    728 LK7024

    4 switching outputs

    264 LK8122

    472 LK8123

    728 LK8124

    * German Federal Water Act

    http://www.ifm.com/products/gb/ds/LK1022.htmhttp://www.ifm.com/products/gb/ds/LK1023.htmhttp://www.ifm.com/products/gb/ds/LK1024.htmhttp://www.ifm.com/products/gb/ds/LK1222.htmhttp://www.ifm.com/products/gb/ds/LK1223.htmhttp://www.ifm.com/products/gb/ds/LK1224.htmhttp://www.ifm.com/products/gb/ds/LK3122.htmhttp://www.ifm.com/products/gb/ds/LK3123.htmhttp://www.ifm.com/products/gb/ds/LK3124.htmhttp://www.ifm.com/products/gb/ds/LK7022.htmhttp://www.ifm.com/products/gb/ds/LK7023.htmhttp://www.ifm.com/products/gb/ds/LK7024.htmhttp://www.ifm.com/products/gb/ds/LK8122.htmhttp://www.ifm.com/products/gb/ds/LK8123.htmhttp://www.ifm.com/products/gb/ds/LK8124.htmhttp://www.ifm.com/products/gb/ds/LK8124.htmhttp://www.ifm.com/products/gb/ds/LK8123.htmhttp://www.ifm.com/products/gb/ds/LK8122.htmhttp://www.ifm.com/products/gb/ds/LK7024.htmhttp://www.ifm.com/products/gb/ds/LK7023.htmhttp://www.ifm.com/products/gb/ds/LK7022.htmhttp://www.ifm.com/products/gb/ds/LK3124.htmhttp://www.ifm.com/products/gb/ds/LK3123.htmhttp://www.ifm.com/products/gb/ds/LK3122.htmhttp://www.ifm.com/products/gb/ds/LK1224.htmhttp://www.ifm.com/products/gb/ds/LK1223.htmhttp://www.ifm.com/products/gb/ds/LK1222.htmhttp://www.ifm.com/products/gb/ds/LK1024.htmhttp://www.ifm.com/products/gb/ds/LK1023.htmhttp://www.ifm.com/products/gb/ds/LK1022.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    11/24

    Continuous capacitive level measurement.For applications on hydraulic and coolant tanks.

       I  m  p  e   d  a  n  c  e

      s  p  e  c   t  r  o  s  c  o  p  y

       C  a  p  a  c   i   t   i  v  e   i  n

      c  o  n   t  a  c   t  w   i   t   h

       t   h  e  m  e   d   i  u  m

       C  a  p  a  c   i   t   i  v  e

      w   i   t   h  o  u   t

      c  o  n   t  a  c   t

       C  a  p  a  c   i   t   i  v  e

      c  o  n   t   i  n  u  o  u  s

       G  u   i   d  e   d

      w  a  v  e  r  a   d  a  r

       H  y   d  r  o  s   t  a   t   i  c

       P   h  o   t  o  e   l  e  c   t  r   i  c

       A  c  c  e  s  s  o  r   i  e  s

    Type LT 

    level sensor 

    For level and 

    temperature.

    Suitable for oils up

    to 70 °C.

    11

    264 For level and temperature LT8022

    Rod length

    [mm]

    Version Order no.

    2 x 2 switching outputs level / temperature

    472 For level and temperature LT8023

    728 For level and temperature LT8024

    For adapters

     see pages

     22 - 23

    http://www.ifm.com/products/gb/ds/LT8022.htmhttp://www.ifm.com/products/gb/ds/LT8023.htmhttp://www.ifm.com/products/gb/ds/LT8024.htmhttp://www.ifm.com/products/gb/ds/LT8024.htmhttp://www.ifm.com/products/gb/ds/LT8023.htmhttp://www.ifm.com/products/gb/ds/LT8022.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    12/24

    Versatile:Modular sensor concept, flexible

    in use.

    Variable:Rods can be cut to size as

    required.

    Reliable:Measuring principle independent

    of temperature influences.

    Optional outputs:Versions with two or four

    switching outputs or analogue

    output 4...20 mA / 0...10 V.

    Selectable:Designs with and without

    display.

    Type LR

    level sensor 

    Display and hand-

    ling on the unit or 

    via IO-Link.

     As an option with

    analogue output 

    or up to four 

     switching outputs.

    Rod lengths

    freely selectable

    between

    10...200 cm.

    Versions to the

    German Federal 

    Water Act 

    available.

    G 3/4 male LR2050

    Processconnection

    Order no.

    2 switching outputs or 1 switching output and1 analogue output 4...20 mA

    G 3/4 male LR7000

    3/4" NPT LR7300

    Processconnection

    Order no.

    2 switching outputs

    G 3/4 male LR9020

    Processconnection

    Order no.

    1 analogue output 4...20 mA or 0...10 V

    G 3/4 male LR3000

    3/4" NPT LR3300

    1 switching output and

    1 analogue output 4...20 mA or 0...10 V

    For industrial applications

    For hygienic areasand viscous media

    12

    Type LR

    level transmitter 

    For industrial 

    applications.

     Analogue output  scalable

    4...20 mA / 0...10 V.

    Protection rating

    IP 69K.

    Easily adjustable

    via IO-Link.

    G 3/4 male LR8000

    3/4" NPT LR8300

    4 switching outputs

    G 3/4 male LR80101)

    4 switching outputs / WHG*

    * German Federal Water Act1)Only in connection with rod and coaxial pipe,

    see page 14

    http://www.ifm.com/products/gb/ds/LR2050.htmhttp://www.ifm.com/products/gb/ds/LR7000.htmhttp://www.ifm.com/products/gb/ds/LR7300.htmhttp://www.ifm.com/products/gb/ds/LR9020.htmhttp://www.ifm.com/products/gb/ds/LR3000.htmhttp://www.ifm.com/products/gb/ds/LR3300.htmhttp://www.ifm.com/products/gb/ds/LR8000.htmhttp://www.ifm.com/products/gb/ds/LR8300.htmhttp://www.ifm.com/products/gb/ds/LR8010.htmhttp://www.ifm.com/products/gb/ds/LR8010.htmhttp://www.ifm.com/products/gb/ds/LR8010.htmhttp://www.ifm.com/products/gb/ds/LR8300.htmhttp://www.ifm.com/products/gb/ds/LR8000.htmhttp://www.ifm.com/products/gb/ds/LR3300.htmhttp://www.ifm.com/products/gb/ds/LR3000.htmhttp://www.ifm.com/products/gb/ds/LR9020.htmhttp://www.ifm.com/products/gb/ds/LR7300.htmhttp://www.ifm.com/products/gb/ds/LR7000.htmhttp://www.ifm.com/products/gb/ds/LR2050.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    13/24

    Continuous level measurementwith guided microwave.For industrial and hygienic applications.

       I  m  p  e   d  a  n  c  e

      s  p  e  c   t  r  o  s  c  o  p  y

       C  a  p  a  c   i   t   i  v  e   i  n

      c  o  n   t  a  c   t  w   i   t   h

       t   h  e  m  e   d   i  u  m

       C  a  p  a  c   i   t   i  v  e

      w   i   t   h  o  u   t

      c  o  n   t  a  c   t

       C  a  p  a  c   i   t   i  v  e

      c  o  n   t   i  n  u  o  u  s

       G  u   i   d  e   d

      w  a  v  e  r  a   d  a  r

       H  y   d  r  o  s   t  a   t   i  c

       P   h  o   t  o  e   l  e  c   t  r   i  c

       A  c  c  e  s  s  o  r   i  e  s

    Aseptoflex Vario G1 LR2750

    Processconnection

    Order no.

    2 switching outputs or 1 switching output and1 analogue output 4...20 mA

    Type LR27 

    hygienic level 

     sensor 

    Display and hand-

    ling on the unit or 

    via IO-Link.

    Medium tempera-

    ture -40...150 °C.

    Pressure-resistant 

    up to 40 bar.

    Rod lengths

    of 15...200 cm

     selectable.

    13

    For rods and coaxial pipes

     see pages

    14 - 15 

    For adapters

     see pages

     22 - 23

    http://www.ifm.com/products/gb/ds/LR2750.htmhttp://www.ifm.com/products/gb/ds/LR2750.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    14/24

    G 3/4

    G 3/4

    14

    For industrial applications

    For hygienic areasand viscous media

    700 E43205

    Length

    [mm]

    Order no.

    Level sensor 

    3/4" NPT 

    Type LR3300

    Type LR7300

    Type LR8300

    800 E43337

    1000 E43207

    1200 E43208

    1400 E43209

    1600 E43210

    2000 E433532)

    2)Only for type LR2050 sensor

    150 E43225

    Length

    [mm]

    Order no.

    210 E43351

    240 E43203

    265 E43352

    300 E43226

    450 E43204

    500 E43227

    Rods for LR level 

     sensors with 3/4"

    NPT oder G 3/4

    male, industrial 

    applications

    Material:high-grade

     stainless steel 

    (1.4404 / 316L)

    1)Only in connectionwith rod andcoaxial pipe

    Level sensor 

    G 3/4 male

    Type LR2050

    Type LR3000

    Type LR7000

    Type LR8000

    Type LR80101 )

    Type LR9020

    150 E43230

    Processconnection

    Length

    [mm]

    Order no.

    210 E43354

    240 E43211

    265 E43355

    300 E43228

    450 E43212

    500 E43229

    700 E43213

    800 E43336

    1000 E43214

    1200 E43215

    1400 E432161600 E43217

    2000 E433562)

    700, slotted E43333

    1200, slotted E43334

    2)Only for type LR2050 sensor

    Coaxial pipes for 

    LR level sensors

    with G 3/4 male,

    industrial applications

    Material:

    high-grade

     stainless steel 

    (1.4301 / 304)

    http://www.ifm.com/products/gb/ds/E43205.htmhttp://www.ifm.com/products/gb/ds/LR3300.htmhttp://www.ifm.com/products/gb/ds/LR7300.htmhttp://www.ifm.com/products/gb/ds/LR8300.htmhttp://www.ifm.com/products/gb/ds/E43337.htmhttp://www.ifm.com/products/gb/ds/E43207.htmhttp://www.ifm.com/products/gb/ds/E43208.htmhttp://www.ifm.com/products/gb/ds/E43209.htmhttp://www.ifm.com/products/gb/ds/E43210.htmhttp://www.ifm.com/products/gb/ds/E43353.htmhttp://www.ifm.com/products/gb/ds/E43353.htmhttp://www.ifm.com/products/gb/ds/E43225.htmhttp://www.ifm.com/products/gb/ds/E43351.htmhttp://www.ifm.com/products/gb/ds/E43203.htmhttp://www.ifm.com/products/gb/ds/E43352.htmhttp://www.ifm.com/products/gb/ds/E43226.htmhttp://www.ifm.com/products/gb/ds/E43204.htmhttp://www.ifm.com/products/gb/ds/E43227.htmhttp://www.ifm.com/products/gb/ds/LR2050.htmhttp://www.ifm.com/products/gb/ds/LR3000.htmhttp://www.ifm.com/products/gb/ds/LR7000.htmhttp://www.ifm.com/products/gb/ds/LR8000.htmhttp://www.ifm.com/products/gb/ds/LR8010.htmhttp://www.ifm.com/products/gb/ds/LR8010.htmhttp://www.ifm.com/products/gb/ds/LR9020.htmhttp://www.ifm.com/products/gb/ds/E43230.htmhttp://www.ifm.com/products/gb/ds/E43354.htmhttp://www.ifm.com/products/gb/ds/E43211.htmhttp://www.ifm.com/products/gb/ds/E43355.htmhttp://www.ifm.com/products/gb/ds/E43228.htmhttp://www.ifm.com/products/gb/ds/E43212.htmhttp://www.ifm.com/products/gb/ds/E43229.htmhttp://www.ifm.com/products/gb/ds/E43213.htmhttp://www.ifm.com/products/gb/ds/E43336.htmhttp://www.ifm.com/products/gb/ds/E43214.htmhttp://www.ifm.com/products/gb/ds/E43215.htmhttp://www.ifm.com/products/gb/ds/E43216.htmhttp://www.ifm.com/products/gb/ds/E43217.htmhttp://www.ifm.com/products/gb/ds/E43356.htmhttp://www.ifm.com/products/gb/ds/E43356.htmhttp://www.ifm.com/products/gb/ds/E43333.htmhttp://www.ifm.com/products/gb/ds/E43334.htmhttp://www.ifm.com/products/gb/ds/E43334.htmhttp://www.ifm.com/products/gb/ds/E43333.htmhttp://www.ifm.com/products/gb/ds/E43356.htmhttp://www.ifm.com/products/gb/ds/E43217.htmhttp://www.ifm.com/products/gb/ds/E43216.htmhttp://www.ifm.com/products/gb/ds/E43215.htmhttp://www.ifm.com/products/gb/ds/E43214.htmhttp://www.ifm.com/products/gb/ds/E43336.htmhttp://www.ifm.com/products/gb/ds/E43213.htmhttp://www.ifm.com/products/gb/ds/E43229.htmhttp://www.ifm.com/products/gb/ds/E43212.htmhttp://www.ifm.com/products/gb/ds/E43228.htmhttp://www.ifm.com/products/gb/ds/E43355.htmhttp://www.ifm.com/products/gb/ds/E43211.htmhttp://www.ifm.com/products/gb/ds/E43354.htmhttp://www.ifm.com/products/gb/ds/E43230.htmhttp://www.ifm.com/products/gb/ds/LR9020.htmhttp://www.ifm.com/products/gb/ds/LR8010.htmhttp://www.ifm.com/products/gb/ds/LR8000.htmhttp://www.ifm.com/products/gb/ds/LR7000.htmhttp://www.ifm.com/products/gb/ds/LR3000.htmhttp://www.ifm.com/products/gb/ds/LR2050.htmhttp://www.ifm.com/products/gb/ds/E43227.htmhttp://www.ifm.com/products/gb/ds/E43204.htmhttp://www.ifm.com/products/gb/ds/E43226.htmhttp://www.ifm.com/products/gb/ds/E43352.htmhttp://www.ifm.com/products/gb/ds/E43203.htmhttp://www.ifm.com/products/gb/ds/E43351.htmhttp://www.ifm.com/products/gb/ds/E43225.htmhttp://www.ifm.com/products/gb/ds/E43353.htmhttp://www.ifm.com/products/gb/ds/E43210.htmhttp://www.ifm.com/products/gb/ds/E43209.htmhttp://www.ifm.com/products/gb/ds/E43208.htmhttp://www.ifm.com/products/gb/ds/E43207.htmhttp://www.ifm.com/products/gb/ds/E43337.htmhttp://www.ifm.com/products/gb/ds/LR8300.htmhttp://www.ifm.com/products/gb/ds/LR7300.htmhttp://www.ifm.com/products/gb/ds/LR3300.htmhttp://www.ifm.com/products/gb/ds/E43205.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    15/2415 

    Continuous level measurementwith guided microwave.Rods and coaxial pipes.

       I  m  p  e   d  a  n  c  e

      s  p  e  c   t  r  o  s  c  o  p  y

       C  a  p  a  c   i   t   i  v  e   i  n

      c  o  n   t  a  c   t  w   i   t   h

       t   h  e  m  e   d   i  u  m

       C  a  p  a  c   i   t   i  v  e

      w   i   t   h  o  u   t

      c  o  n   t  a  c   t

       C  a  p  a  c   i   t   i  v  e

      c  o  n   t   i  n  u  o  u  s

       G  u   i   d  e   d

      w  a  v  e  r  a   d  a  r

       H  y   d  r  o  s   t  a   t   i  c

       P   h  o   t  o  e   l  e  c   t  r   i  c

       A  c  c  e  s  s  o  r   i  e  s

    3/4" NPT

    450 E43218

    Processconnection

    Length

    [mm]

    Order no.

    700 E43219

    1000 E43220

    1200 E43223

    1400 E43224

    1600 E43221

    150 E43345

    Length

    [mm]

    Order no.

    300 E43346

    500 E43340

    700 E43347

    1000 E43341

    1500 E43348

    2000 E43342

    Type LR2750

    hygienic level 

     sensor 

    Rods for level 

     sensor type

    LR2750 , hygienic 

    applications

    Material:

    high-grade stainless steel 

    (1.4404 / 316L)

     For a  w ide

     se lec t ion o f o t her

    acce s sor ie s  v i s i t

     w w w. i fm.com

    For adapters

     see pages

     22 - 23

    http://www.ifm.com/products/gb/ds/E43218.htmhttp://www.ifm.com/products/gb/ds/E43219.htmhttp://www.ifm.com/products/gb/ds/E43220.htmhttp://www.ifm.com/products/gb/ds/E43223.htmhttp://www.ifm.com/products/gb/ds/E43224.htmhttp://www.ifm.com/products/gb/ds/E43221.htmhttp://www.ifm.com/products/gb/ds/E43345.htmhttp://www.ifm.com/products/gb/ds/E43346.htmhttp://www.ifm.com/products/gb/ds/E43340.htmhttp://www.ifm.com/products/gb/ds/E43347.htmhttp://www.ifm.com/products/gb/ds/E43341.htmhttp://www.ifm.com/products/gb/ds/E43348.htmhttp://www.ifm.com/products/gb/ds/E43342.htmhttp://www.ifm.com/products/gb/ds/LR2750.htmhttp://www.ifm.com/products/gb/ds/LR2750.htmhttp://www.ifm.com/products/gb/ds/LR2750.htmhttp://www.ifm.com/products/gb/ds/LR2750.htmhttp://www.ifm.com/products/gb/ds/E43342.htmhttp://www.ifm.com/products/gb/ds/E43348.htmhttp://www.ifm.com/products/gb/ds/E43341.htmhttp://www.ifm.com/products/gb/ds/E43347.htmhttp://www.ifm.com/products/gb/ds/E43340.htmhttp://www.ifm.com/products/gb/ds/E43346.htmhttp://www.ifm.com/products/gb/ds/E43345.htmhttp://www.ifm.com/products/gb/ds/E43221.htmhttp://www.ifm.com/products/gb/ds/E43224.htmhttp://www.ifm.com/products/gb/ds/E43223.htmhttp://www.ifm.com/products/gb/ds/E43220.htmhttp://www.ifm.com/products/gb/ds/E43219.htmhttp://www.ifm.com/products/gb/ds/E43218.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    16/2416 

    Robust:Overload-protected measuring

    principles with a good long-term

    stability.

    Versatile:Compact sensors with and

    without display.

    Precise:Ceramic-capacitive and

    piezoresistive measuring cells.

    For industrial applications

    Type PA

     pressure sensor 

     2-wire pressure

    transmitter.

    Ceramic-capacitive

    measuring cell.

    G 1/4 female 0...1000 0...1000 PA9027

    Processconnection

    Relative pressuremeasuring range

    [mbar]

    Relative pressuremeasuring range

    [mbar]

    Order no.

    Analogue output 4...20 mA Analogue output 0...10 V

    Type PS

     submersible

     pressure

    transmitter 

    PUR or FEP cable

    for high resistance

    to media.

    Version with ATEX 

    approval for group I cat. M1

    and group II 

    cat. 1G and 1D.

    Pressure compen-

     sation via inter-

    nally vented cable.

    Order no.

    PA3027

    G 1/4 female 0...250 0...250 PA9028PA3028

    G 1/4 male 0...250 PA3528

    G 1/4 male 0...100 PA3589

    0.25 FEP, 5 PS4208

    Relative pressuremeasuring range

    [mbar]

    Cable

    [m]

    Order no.

    For high resistance to media, CE approval

    0.6 FEP, 10 PS4407

    1 FEP, 15 PS4417

    0.25 FEP, 5 PS308A

    For hazardous areas, CE, Ex, GL approvals

    0.6 FEP, 10 PS307A

    1 FEP, 15 PS317A

    0.25 PUR, 5 PS3208

    Relative pressuremeasuring range

    [mbar]

    Cable

    [m]

    Order no.

    For standard applications, CE approval

    0.6 PUR, 10 PS3407

    0.6 PUR, 15 PS3427

    0.6 PUR, 30 PS3607

    1 PUR, 15 PS3417

    1 PUR, 30 PS3617

    http://www.ifm.com/products/gb/ds/PA9027.htmhttp://www.ifm.com/products/gb/ds/PA3027.htmhttp://www.ifm.com/products/gb/ds/PA9028.htmhttp://www.ifm.com/products/gb/ds/PA3028.htmhttp://www.ifm.com/products/gb/ds/PA3528.htmhttp://www.ifm.com/products/gb/ds/PA3589.htmhttp://www.ifm.com/products/gb/ds/PS4208.htmhttp://www.ifm.com/products/gb/ds/PS4407.htmhttp://www.ifm.com/products/gb/ds/PS4417.htmhttp://www.ifm.com/products/gb/ds/PS308A.htmhttp://www.ifm.com/products/gb/ds/PS307A.htmhttp://www.ifm.com/products/gb/ds/PS317A.htmhttp://www.ifm.com/products/gb/ds/PS3208.htmhttp://www.ifm.com/products/gb/ds/PS3407.htmhttp://www.ifm.com/products/gb/ds/PS3427.htmhttp://www.ifm.com/products/gb/ds/PS3607.htmhttp://www.ifm.com/products/gb/ds/PS3417.htmhttp://www.ifm.com/products/gb/ds/PS3617.htmhttp://www.ifm.com/products/gb/ds/PS3617.htmhttp://www.ifm.com/products/gb/ds/PS3417.htmhttp://www.ifm.com/products/gb/ds/PS3607.htmhttp://www.ifm.com/products/gb/ds/PS3427.htmhttp://www.ifm.com/products/gb/ds/PS3407.htmhttp://www.ifm.com/products/gb/ds/PS3208.htmhttp://www.ifm.com/products/gb/ds/PS317A.htmhttp://www.ifm.com/products/gb/ds/PS307A.htmhttp://www.ifm.com/products/gb/ds/PS308A.htmhttp://www.ifm.com/products/gb/ds/PS4417.htmhttp://www.ifm.com/products/gb/ds/PS4407.htmhttp://www.ifm.com/products/gb/ds/PS4208.htmhttp://www.ifm.com/products/gb/ds/PA3589.htmhttp://www.ifm.com/products/gb/ds/PA3528.htmhttp://www.ifm.com/products/gb/ds/PA9028.htmhttp://www.ifm.com/products/gb/ds/PA3028.htmhttp://www.ifm.com/products/gb/ds/PA3027.htmhttp://www.ifm.com/products/gb/ds/PA9027.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    17/2417 

    Continuous hydrostatic level measurementin industrial applications.For use on tanks and in free-flowing waterways.

       I  m  p  e   d  a  n  c  e

      s  p  e  c   t  r  o  s  c  o  p  y

       C  a  p  a  c   i   t   i  v  e   i  n

      c  o  n   t  a  c   t  w   i   t   h

       t   h  e  m  e   d   i  u  m

       C  a  p  a  c   i   t   i  v  e

      w   i   t   h  o  u   t

      c  o  n   t  a  c   t

       C  a  p  a  c   i   t   i  v  e

      c  o  n   t   i  n  u  o  u  s

       G  u   i   d  e   d

      w  a  v  e  r  a   d  a  r

       H  y   d  r  o  s   t  a   t   i  c

       P   h  o   t  o  e   l  e  c   t  r   i  c

       A  c  c  e  s  s  o  r   i  e  s

    Processconnection

    Relative pressuremeasuring range

    [mbar]

    Relative pressuremeasuring range

    [mbar]

    Order no.

    2 switching outputs 1 switching output and1 analogue outp. 4...20 mA / 0...10 V

    Order no.

    G 1/4 female 0...1000 0...1000 PN3097PN7097

    G 1/4 male 0...1000 0...1000 PN3597PN7597

    2 switching outputs or 1 switching output and1 analogue output 4...20 mA / 0...10 V, scalable

    G 1/4 female 0...1000 -12.5...250 PN2098PN2097

    G 1/4 male 0...1000 -12.5...250 PN2598PN2597

    G 1/4 female -500...500 PN2169

    G 1/4 male -500...500 PN2569

    Type PN pressure

    sensor 

    Programmable

    2-colour display,

    clearly visible

    switch-point LEDs.

    Rotatable process

    connection.

    Operation via

    3 raised push-

    buttons.

    Type PG

     pressure sensor 

    Optimum

    legibility due to

    the electronic 

     pointer display.

    Rotatable display.

    Display of the

    trend or of the

    minimum and 

    maximum values.

    Processconnection

    Relative pressuremeasuring range

    [mbar]

    1 switching output and1 analogue output 4...20 mA / 20...4 mA, scalable

    Order no.

    G 1/2 male 0...1000 PG2457

    G 1/2 male 0...250 PG2458

    G 1/2 male 0...100 PG2489

    For adapters

     see pages 22 - 23

    http://www.ifm.com/products/gb/ds/PN3097.htmhttp://www.ifm.com/products/gb/ds/PN7097.htmhttp://www.ifm.com/products/gb/ds/PN3597.htmhttp://www.ifm.com/products/gb/ds/PN7597.htmhttp://www.ifm.com/products/gb/ds/PN2098.htmhttp://www.ifm.com/products/gb/ds/PN2097.htmhttp://www.ifm.com/products/gb/ds/PN2598.htmhttp://www.ifm.com/products/gb/ds/PN2597.htmhttp://www.ifm.com/products/gb/ds/PN2169.htmhttp://www.ifm.com/products/gb/ds/PN2569.htmhttp://www.ifm.com/products/gb/ds/PG2457.htmhttp://www.ifm.com/products/gb/ds/PG2458.htmhttp://www.ifm.com/products/gb/ds/PG2489.htmhttp://www.ifm.com/products/gb/ds/PG2489.htmhttp://www.ifm.com/products/gb/ds/PG2458.htmhttp://www.ifm.com/products/gb/ds/PG2457.htmhttp://www.ifm.com/products/gb/ds/PN2569.htmhttp://www.ifm.com/products/gb/ds/PN2169.htmhttp://www.ifm.com/products/gb/ds/PN2598.htmhttp://www.ifm.com/products/gb/ds/PN2597.htmhttp://www.ifm.com/products/gb/ds/PN2098.htmhttp://www.ifm.com/products/gb/ds/PN2097.htmhttp://www.ifm.com/products/gb/ds/PN3597.htmhttp://www.ifm.com/products/gb/ds/PN7597.htmhttp://www.ifm.com/products/gb/ds/PN3097.htmhttp://www.ifm.com/products/gb/ds/PN7097.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    18/2418 

    G1 male

    Aseptoflex Vario

    -0.01...0.1 PG2789

    Hygienic:Ingress resistance, material

    and approvals according to

    hygiene requirements.

    Robust:Overload-resistant ceramic-

    capacitive measuring cells with

    long-term stability.

    Versatile:Variable process connections.

    Precise:High overall accuracy (0,2 %).

    For CIP / SIP applications:High temperature resistance

    and electronic temperature

    compensation.

    For hygienic areasand viscous media

    Type PG

     pressure sensor 

    Optimum

    legibility due to

    the electronic 

     pointer display.

    Rotatable display.

    Display of the

    trend or of the

    minimum and 

    maximum values.

    Processconnection

    Measuringrange[bar]

    Order no.

    1 switching output and1 analogue output 4...20 mA / 20...4 mA, scalable

    -0.01...0.25 PG2798

    -0.05...1 PG2797-1...1 PG2799

    G1 malesealing cone

    -0.01...0.1 PG2889

    -0.01...0.25 PG2898

    -0.05...1 PG2897

    -1...1 PG2899

    http://www.ifm.com/products/gb/ds/PG2789.htmhttp://www.ifm.com/products/gb/ds/PG2798.htmhttp://www.ifm.com/products/gb/ds/PG2797.htmhttp://www.ifm.com/products/gb/ds/PG2799.htmhttp://www.ifm.com/products/gb/ds/PG2889.htmhttp://www.ifm.com/products/gb/ds/PG2898.htmhttp://www.ifm.com/products/gb/ds/PG2897.htmhttp://www.ifm.com/products/gb/ds/PG2899.htmhttp://www.ifm.com/products/gb/ds/PG2899.htmhttp://www.ifm.com/products/gb/ds/PG2897.htmhttp://www.ifm.com/products/gb/ds/PG2898.htmhttp://www.ifm.com/products/gb/ds/PG2889.htmhttp://www.ifm.com/products/gb/ds/PG2799.htmhttp://www.ifm.com/products/gb/ds/PG2797.htmhttp://www.ifm.com/products/gb/ds/PG2798.htmhttp://www.ifm.com/products/gb/ds/PG2789.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    19/2419

    Continuous hydrostatic level measurementin hygienic areas.For applications on large tanks.

       I  m  p  e   d  a  n  c  e

      s  p  e  c   t  r  o  s  c  o  p  y

       C  a  p  a  c   i   t   i  v  e   i  n

      c  o  n   t  a  c   t  w   i   t   h

       t   h  e  m  e   d   i  u  m

       C  a  p  a  c   i   t   i  v  e

      w   i   t   h  o  u   t

      c  o  n   t  a  c   t

       C  a  p  a  c   i   t   i  v  e

      c  o  n   t   i  n  u  o  u  s

       G  u   i   d  e   d

      w  a  v  e  r  a   d  a  r

       H  y   d  r  o  s   t  a   t   i  c

       P   h  o   t  o  e   l  e  c   t  r   i  c

       A  c  c  e  s  s  o  r   i  e  s

    G1 male

    Aseptoflex Vario

    -0.01...0.1 PI2789

    Type PI 

    pressure sensor 

    Programmable

    analogue output 

    in 2-wire

    operation.

    Additional 

    switching output 

    in 3/4-wire

    operation.

    Processconnection

    Measuringrange[bar]

    Order no.

    1 switching output and1 analogue output 4...20 mA / 20...4 mA

    -0.01...0.25 PI2798

    -0.05...1 PI2797-1...1 PI2799

    G1 malesealing cone

    -0.01...0.1 PI2889

    -0.01...0.25 PI2898

    -0.05...1 PI2897

    -1...1 PI2899

    For adapters

     see pages

     22 - 23

    http://www.ifm.com/products/gb/ds/PI2789.htmhttp://www.ifm.com/products/gb/ds/PI2798.htmhttp://www.ifm.com/products/gb/ds/PI2797.htmhttp://www.ifm.com/products/gb/ds/PI2799.htmhttp://www.ifm.com/products/gb/ds/PI2889.htmhttp://www.ifm.com/products/gb/ds/PI2898.htmhttp://www.ifm.com/products/gb/ds/PI2897.htmhttp://www.ifm.com/products/gb/ds/PI2899.htmhttp://www.ifm.com/products/gb/ds/PI2899.htmhttp://www.ifm.com/products/gb/ds/PI2897.htmhttp://www.ifm.com/products/gb/ds/PI2898.htmhttp://www.ifm.com/products/gb/ds/PI2889.htmhttp://www.ifm.com/products/gb/ds/PI2799.htmhttp://www.ifm.com/products/gb/ds/PI2797.htmhttp://www.ifm.com/products/gb/ds/PI2798.htmhttp://www.ifm.com/products/gb/ds/PI2789.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    20/24 20

    Longest distances:Photoelectric level detection

    of bulk materials and non-

    transparent liquids, for levels

    up to 9.8 m.

    Convenient:Scalable detection range with

    window function.

    Reliable detection:Can be used in applications

    needing background suppression.

    Flexible mounting:Extensive range of fixing

    components.

    For industrial applications

    0.2...9.8M12

    connector< 15 x 15

    Measuringrange

    [m]

    Connection Light spot diameter

    [mm]

    2 switching outputs or 1 switching output and1 analogue output 4...20 mA / 0...10 V, scalable

    Type O1D photo-

    electric distance

     sensor with time

    of flight tech-

    nology 

    Resistant to extra-

    neous light up to

    100,000 lux.

     2 switching out-

     puts; one output 

    can be configured 

    as analogue

    output.

    4-digit alpha-

    numeric display.

    Order no.

    O1D300

    Order no w.

     0 8 0 0 16 16 16  4 or

     in  t he e - s hop a t

     w w w. i fm.com

    http://www.ifm.com/products/gb/ds/O1D300.htmhttp://www.ifm.com/products/gb/ds/O1D300.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    21/24 21

    Continuous photoelectric level measurement.For long distances without contact to the medium.

       I  m  p  e   d  a  n  c  e

      s  p  e  c   t  r  o  s  c  o  p  y

       C  a  p  a  c   i   t   i  v  e   i  n

      c  o  n   t  a  c   t  w   i   t   h

       t   h  e  m  e   d   i  u  m

       C  a  p  a  c   i   t   i  v  e

      w   i   t   h  o  u   t

      c  o  n   t  a  c   t

       C  a  p  a  c   i   t   i  v  e

      c  o  n   t   i  n  u  o  u  s

       G  u   i   d  e   d

      w  a  v  e  r  a   d  a  r

       H  y   d  r  o  s   t  a   t   i  c

       P   h  o   t  o  e   l  e  c   t  r   i  c

       A  c  c  e  s  s  o  r   i  e  s

     Accessories

    No. Version Order no.

    1Mounting bracket

    high-grade stainless steel (1.4404 / 316L)E21120

    2Clamp mounting set for rod mount

    Ø 12 mmE2D101

    3 Mounting adapter withprocess connection G1 male E21224

    4Mounting rod, 100 mm, Ø 12 mm,

    M10 thread, stainless steelE20938

    5Mounting rod, 200 mm, Ø 12 mm,

    M10 thread, stainless steelE20940

    6Cube for mounting on an aluminium profile,

    M10 thread, stainless steelE20951

    Mounting accessories

    7Protective cover, glass E21171

    Device protection

    8 Cooling box E21248

    Protective cover, PMMA E21133

    1

    8

    7

    654

    3

    2

    http://www.ifm.com/products/gb/ds/E21120.htmhttp://www.ifm.com/products/gb/ds/E2D101.htmhttp://www.ifm.com/products/gb/ds/E21224.htmhttp://www.ifm.com/products/gb/ds/E20938.htmhttp://www.ifm.com/products/gb/ds/E20940.htmhttp://www.ifm.com/products/gb/ds/E20951.htmhttp://www.ifm.com/products/gb/ds/E21171.htmhttp://www.ifm.com/products/gb/ds/E21248.htmhttp://www.ifm.com/products/gb/ds/E21133.htmhttp://www.ifm.com/products/gb/ds/E21133.htmhttp://www.ifm.com/products/gb/ds/E21248.htmhttp://www.ifm.com/products/gb/ds/E21171.htmhttp://www.ifm.com/products/gb/ds/E20951.htmhttp://www.ifm.com/products/gb/ds/E20940.htmhttp://www.ifm.com/products/gb/ds/E20938.htmhttp://www.ifm.com/products/gb/ds/E21224.htmhttp://www.ifm.com/products/gb/ds/E2D101.htmhttp://www.ifm.com/products/gb/ds/E21120.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    22/24

    ––

    E43315

    E43309

    E43310

    E43311

    E43312

    1

    2

    Clamp 1 - 1.5"

    Processconnection

    No. Order no. Order no. withleakage port

    E33401

    Mounting adapters for industrial and hygienic applications

     22

    For industrial applications

    For hygienic areasand viscous media

    Clamp 2" E33402

    Pipe fitting DN25 E43304

    Pipe fitting DN40 E43305

    3Varivent type F DN25, D = 50 E43306

    Varivent type N DN40...150, D = 68 E43307

    4 Screw-in adapter G 1 E43303

    Screw-in adapter G 3/4 E43302

    5 Pipe fitting DN25 SMS E33430

    Sealing plug G 1/2 E43308

    Screw-in adapter 3/4" NPT E43313

    6 Collar G 1/2 Ø 45 mm E30056

    Welding adapters for industrial and hygienic applications

    7 Ball G 1/2 Ø 35 mm E30055

    9 Long design G 1/2 Ø 50 mm E43319

    10 Welding mandrel G 1/2 E43314

    8For tanks G 1/2 Ø 30 mm E43300

    For pipes G 1/2 Ø 29 mm E43301

    11

    T-piece DN25 E43316

    T-pieces for industrial and hygienic applications

    T-piece DN40 E43317

    T-piece DN50 E43318

    12 Clamp adapter for type LMT1041) E43349

    Variable clamp adapters

    Clamp adapter for type LMT1051) E43322

    1)Only in connection with G 1/2 female adapter

     Adapters G 1/2

    for type LMT 1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12 Adapters for 

    types LR, LK 22

    23

    F o r  a  w i d e se l e c t i o n o f  o t he r a c c e sso r i e s v i si t w w w .i f m.c o m

    http://www.ifm.com/products/gb/ds/E43315.htmhttp://www.ifm.com/products/gb/ds/E43309.htmhttp://www.ifm.com/products/gb/ds/E43310.htmhttp://www.ifm.com/products/gb/ds/E43311.htmhttp://www.ifm.com/products/gb/ds/E43312.htmhttp://www.ifm.com/products/gb/ds/E33401.htmhttp://www.ifm.com/products/gb/ds/E33402.htmhttp://www.ifm.com/products/gb/ds/E43304.htmhttp://www.ifm.com/products/gb/ds/E43305.htmhttp://www.ifm.com/products/gb/ds/E43306.htmhttp://www.ifm.com/products/gb/ds/E43307.htmhttp://www.ifm.com/products/gb/ds/E43303.htmhttp://www.ifm.com/products/gb/ds/E43302.htmhttp://www.ifm.com/products/gb/ds/E33430.htmhttp://www.ifm.com/products/gb/ds/E43308.htmhttp://www.ifm.com/products/gb/ds/E43313.htmhttp://www.ifm.com/products/gb/ds/E30056.htmhttp://www.ifm.com/products/gb/ds/E30055.htmhttp://www.ifm.com/products/gb/ds/E43319.htmhttp://www.ifm.com/products/gb/ds/E43314.htmhttp://www.ifm.com/products/gb/ds/E43300.htmhttp://www.ifm.com/products/gb/ds/E43301.htmhttp://www.ifm.com/products/gb/ds/E43316.htmhttp://www.ifm.com/products/gb/ds/E43317.htmhttp://www.ifm.com/products/gb/ds/E43318.htmhttp://www.ifm.com/products/gb/ds/E43349.htmhttp://www.ifm.com/products/gb/ds/E43322.htmhttp://www.ifm.com/products/gb/ds/E43322.htmhttp://www.ifm.com/products/gb/ds/E43349.htmhttp://www.ifm.com/products/gb/ds/E43318.htmhttp://www.ifm.com/products/gb/ds/E43317.htmhttp://www.ifm.com/products/gb/ds/E43316.htmhttp://www.ifm.com/products/gb/ds/E43301.htmhttp://www.ifm.com/products/gb/ds/E43300.htmhttp://www.ifm.com/products/gb/ds/E43314.htmhttp://www.ifm.com/products/gb/ds/E43319.htmhttp://www.ifm.com/products/gb/ds/E30055.htmhttp://www.ifm.com/products/gb/ds/E30056.htmhttp://www.ifm.com/products/gb/ds/E43313.htmhttp://www.ifm.com/products/gb/ds/E43308.htmhttp://www.ifm.com/products/gb/ds/E33430.htmhttp://www.ifm.com/products/gb/ds/E43302.htmhttp://www.ifm.com/products/gb/ds/E43303.htmhttp://www.ifm.com/products/gb/ds/E43307.htmhttp://www.ifm.com/products/gb/ds/E43306.htmhttp://www.ifm.com/products/gb/ds/E43305.htmhttp://www.ifm.com/products/gb/ds/E43304.htmhttp://www.ifm.com/products/gb/ds/E33402.htmhttp://www.ifm.com/products/gb/ds/E33401.htmhttp://www.ifm.com/products/gb/ds/E43312.htmhttp://www.ifm.com/products/gb/ds/E43311.htmhttp://www.ifm.com/products/gb/ds/E43310.htmhttp://www.ifm.com/products/gb/ds/E43309.htmhttp://www.ifm.com/products/gb/ds/E43315.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    23/24

    16 –Flange DRD, D = 65 E33242

    E33228

    E3322915

    Varivent type F DN25, D = 50 E33221

    Varivent type N DN40...150, D = 68 E33222

    E33208

    E33209

    E33304

     23

    Accessories.Adapters for level sensors inindustrial and hygienic applications.

       I  m  p  e   d  a  n  c  e

      s  p  e  c   t  r  o  s  c  o  p  y

       C  a  p  a  c   i   t   i  v  e   i  n

      c  o  n   t  a  c   t  w   i   t   h

       t   h  e  m  e   d   i  u  m

       C  a  p  a  c   i   t   i  v  e

      w   i   t   h  o  u   t

      c  o  n   t  a  c   t

       C  a  p  a  c   i   t   i  v  e

      c  o  n   t   i  n  u  o  u  s

       G  u   i   d  e   d

      w  a  v  e  r  a   d  a  r

       H  y   d  r  o  s   t  a   t   i  c

       P   h  o   t  o  e   l  e  c   t  r   i  c

       A  c  c  e  s  s  o  r   i  e  s

    13

    14

    Clamp 1 - 1.5"

    Processconnection

    No. Order no. Order no. withleakage port

    E33201

    Mounting adapters for industrial and hygienic applications

    Clamp 2" E33202

    Pipe fitting DN32 E33211

    Pipe fitting DN50 E33213

    Pipe fitting DN40 E33212

    Universal process adapter Rd52 E33340

    Pipe fitting DIN 11864-1 A-BS –

     Adapters G1 male / 

     Aseptoflex Vario

    for types

    PG, PI, LR

    E30130

    17 Welding adapter Ø 50 mm E30122

    Welding adapters for industrial and hygienic applications

    Sealing plug E30128

    No. Version Order no.

    18 Mounting clamp Ø 16 mm E43000

    19 Welding adapter Ø 50 mm E43002

    Mounting adapters

    21Climatic tube, 264 mm long E43100

    Device protection

    Climatic tube, 728 mm long E43102

    Climatic tube, 472 mm long E43101

    Mounting adapter G 3/4 E43003

    20 Mounting adapter G 1 E43004

    Mounting adapter 3/4" NPT E43012

    Climatic tube, 132 mm long E43103

    Version Order no.

    Flange plate 73 - 90 / G 3/4 E43201

    Flange plate 65 - 80 / G 3/4 E43202

    Mounting adapters

    Protective cover E43910

    Device protection

     F ind  t he

     su i ta b le  soc ke t:

     w w w. i fm.com

    13

    14

    15

    16

    17

    18

    19

    20

    21

     Adapters for 

    types LI, LK, LT 

    http://www.ifm.com/products/gb/ds/E33242.htmhttp://www.ifm.com/products/gb/ds/E33228.htmhttp://www.ifm.com/products/gb/ds/E33229.htmhttp://www.ifm.com/products/gb/ds/E33221.htmhttp://www.ifm.com/products/gb/ds/E33222.htmhttp://www.ifm.com/products/gb/ds/E33208.htmhttp://www.ifm.com/products/gb/ds/E33209.htmhttp://www.ifm.com/products/gb/ds/E33304.htmhttp://www.ifm.com/products/gb/ds/E33201.htmhttp://www.ifm.com/products/gb/ds/E33202.htmhttp://www.ifm.com/products/gb/ds/E33211.htmhttp://www.ifm.com/products/gb/ds/E33213.htmhttp://www.ifm.com/products/gb/ds/E33212.htmhttp://www.ifm.com/products/gb/ds/E33340.htmhttp://www.ifm.com/products/gb/ds/E30130.htmhttp://www.ifm.com/products/gb/ds/E30122.htmhttp://www.ifm.com/products/gb/ds/E30128.htmhttp://www.ifm.com/products/gb/ds/E43000.htmhttp://www.ifm.com/products/gb/ds/E43002.htmhttp://www.ifm.com/products/gb/ds/E43100.htmhttp://www.ifm.com/products/gb/ds/E43102.htmhttp://www.ifm.com/products/gb/ds/E43101.htmhttp://www.ifm.com/products/gb/ds/E43003.htmhttp://www.ifm.com/products/gb/ds/E43004.htmhttp://www.ifm.com/products/gb/ds/E43012.htmhttp://www.ifm.com/products/gb/ds/E43103.htmhttp://www.ifm.com/products/gb/ds/E43201.htmhttp://www.ifm.com/products/gb/ds/E43202.htmhttp://www.ifm.com/products/gb/ds/E43910.htmhttp://www.ifm.com/products/gb/ds/E43910.htmhttp://www.ifm.com/products/gb/ds/E43202.htmhttp://www.ifm.com/products/gb/ds/E43201.htmhttp://www.ifm.com/products/gb/ds/E43103.htmhttp://www.ifm.com/products/gb/ds/E43012.htmhttp://www.ifm.com/products/gb/ds/E43004.htmhttp://www.ifm.com/products/gb/ds/E43003.htmhttp://www.ifm.com/products/gb/ds/E43101.htmhttp://www.ifm.com/products/gb/ds/E43102.htmhttp://www.ifm.com/products/gb/ds/E43100.htmhttp://www.ifm.com/products/gb/ds/E43002.htmhttp://www.ifm.com/products/gb/ds/E43000.htmhttp://www.ifm.com/products/gb/ds/E30128.htmhttp://www.ifm.com/products/gb/ds/E30122.htmhttp://www.ifm.com/products/gb/ds/E30130.htmhttp://www.ifm.com/products/gb/ds/E33340.htmhttp://www.ifm.com/products/gb/ds/E33212.htmhttp://www.ifm.com/products/gb/ds/E33213.htmhttp://www.ifm.com/products/gb/ds/E33211.htmhttp://www.ifm.com/products/gb/ds/E33202.htmhttp://www.ifm.com/products/gb/ds/E33201.htmhttp://www.ifm.com/products/gb/ds/E33304.htmhttp://www.ifm.com/products/gb/ds/E33209.htmhttp://www.ifm.com/products/gb/ds/E33208.htmhttp://www.ifm.com/products/gb/ds/E33222.htmhttp://www.ifm.com/products/gb/ds/E33221.htmhttp://www.ifm.com/products/gb/ds/E33229.htmhttp://www.ifm.com/products/gb/ds/E33228.htmhttp://www.ifm.com/products/gb/ds/E33242.htm

  • 8/20/2019 Ifm the Right Choice for Your Application Level Sensors From Ifm

    24/24

    Visit our website:

    www.ifm.com

    ifm electronic gmbh

    Friedrichstraße 145128 Essen

    Tel. +49 / 201 / 24 22-0Fax +49 / 201 / 24 22-1200

    E-mail [email protected]

    Over 70 locations worldwide –at a glance at www.ifm.com

    Position sensors

    Sensors formotion control

    Industrial imaging

    Safety technology

    Process sensors

    Condition monitoringsystems

    Industrialcommunication

    Identification systems

    Systems formobile machines

    Connectiontechnology

    Overviewifm product range:

    Accessories

    t   i  c   l  e  n  o .

       7   8   0   0

       1   7   6   7  ·   W  e  r  e  s  e  r  v  e   t   h  e  r   i  g   h   t   t  o  m  a   k  e   t  e  c   h  n   i  c  a   l  a   l   t  e

      r  a   t   i  o  n  s  w   i   t   h  o  u   t  p  r   i  o  r  n  o   t   i  c  e .  ·   P  r   i  n   t  e   d   i  n   G  e  r  m  a  n  y

      o  n  n  o  n  -  c   h   l  o  r   i  n  e   b   l  e  a  c   h  e   d  p  a  p  e  r .   1   1   /   1   5