Holophane Outdoor Substation 04250 Series Brochure 1971
-
Upload
alan-masters -
Category
Documents
-
view
215 -
download
1
Transcript of Holophane Outdoor Substation 04250 Series Brochure 1971
7/28/2019 Holophane Outdoor Substation 04250 Series Brochure 1971
http://slidepdf.com/reader/full/holophane-outdoor-substation-04250-series-brochure-1971 1/2
)
s
(o
!!J9F69
I
z
HOLOPHANE OUTDOOR SUBSTATION UNIT O4E5Ot u?$iar*,i,fd c €*tf.qac?r'];$. a{:s
ABSENCE OF GLARE. The light is refracted upward hence
the operators'sight lines follow the direction of lightdistribution.HIGH UTILIZATION OF LIGHT OUTPUT. The upward dis-
tribution of more than 60 percent of total lamp lumensprovides eflective illumination on overhead vertical and
horizontal surfaces.
PERMANENCE. The one-piece prismatic light controllingelement is molded ENDURAL glass which has built-insafety factoN to withstand all tempelature gradients
encountered in operating outdoor luminaires. Metalfixture parts of stainless steel and cast or spun ahlrni-num will withstand severe wcather.NO PERMANENT DEPRECIATION. Original output can be
restored by thorough cleaning, and natural cleansing
action of rain maintains high operating output.
LOWMAINTENANCE
COST. Sealed gasket assembliesaround top and bottom of refractor keep interior of unitdirt and weather tight.SIMPLE ADJUSTMENT OF LIGHT DISTRIBUTION ON JOB.
While lamp is on, entire unit can be rotated up or down
to adjust beam of maximum candlcpower to reach loca-
tions oJ disqonnect switches and other overhead struc-ture. A set screw locks unit in adjustment,ACCESSIBILITY FOR RELAMPING. Unit can be morrnted
on bracket or post top where there will be no danger of
contact with high voltage when relamping.
!;,No.04250
For over 35 years, Holophane units have been used
for lighling outdoor substations in all parts of the
United States, Canada, and Mexico. During that time,
several minor mechanical revisions had been made inthe design of these units but now an entirely new and
improved luminaire has been developed, based on ex-
perience and knowledge gained from successful opera-
tion of this type of equipment in the field.
The core of the new design is the basic light con-
trolling element - a one piece plislJ,atic refractor made
of ENDURAL{, (thermally shble) glass. On the bottom
of this refractor there is a spun on and sealed 16 gauge
Alzak aluminum reflector; the reflector, in turn, being
assembled to a threaded cast aluminum collar.
The collar engages threads in a cast aluminum fitterwhich supports a mogul basc lamp socket, and is ma-
chined to slip fit to a depth of 2%" over a 1%" pipe. The
fitter is locked in place on mounting bracket or post top
by two stainless steel set screws.
The top of the refractor is closed by a 16 gauge, 11
inch diameter aluminum coverlvhich is gasketed and
clamped to the refractor by two spring tension stainless
steel latches. Interior access is obtained by removing this
top cover. When unit is being relamped, the cover hangsoutside the refractor on a permanently attached stainless
sieel bead chain thei'eby fi'eeing both hands of the main-
tenance man.
The refractor assembly can be rotated on the threaded
fitter. The beam o{ maximum candlepower, which peaks
nornally at 105', can be raised or lowered 5".
CHOICE OF LAMPS.
500 or 300 watt incandescent lamps may be used.
400 watt mercury vapor, or
Sketch of No. 04250
7/28/2019 Holophane Outdoor Substation 04250 Series Brochure 1971
http://slidepdf.com/reader/full/holophane-outdoor-substation-04250-series-brochure-1971 2/2
PHOTOMETPIC TESI REPORTHOI.OIHANE COMPANY, INC.
7t
0il
a,}959?l
r02i
ro5r0?lrt0112i115
u,2trtor3t
u01lr5150r's
ll8375399lr9t
1280
2S\o
lllro376t3850
7915)9O5l&oll!r5
22851t651380
8177t!5
539rd ol Eo1.phE. xo. olr25o
pd;ricn .{ bhp lrsht c.otor lr-?/8' rbot. botr6
r,un.n 21000w.6 lr00 volr'surr Br-3? Fit.R.P.M. Iu! ud r6c..roE-5or.n DnhR 25 F..t
85
e2+95
9?;
102*
1o?+
110
1r5-11?]120
1251t013t
1t+5
150lts165
77t
252311!
3195
11907235
1585t655t+5aJ461
L6l
ll+12l[
171t78
rd t fiolophs. No. olr25o
r6irr.n .f r.hp lrsht c.nr.r !*r!.t!acto!
ll'' c, r:la1 FllMontrv nr rocoo$/.h 500 v.l'r r20sutb Ps-lro-cr rn. cc-8
acc..!ory-50
MOUNTING ACCESSORIES
Bracket No. 0876 is used on vertical members of sub-
station structures for NEW installations of No.04250.
Additional ground lighting units can also be attachedto this bracket.
0876 (Bracket)
For RELIGHTING jobs where there are old style1%" threaded brackets (Catalog No. 0871-T), arr adapt-er, Catalog No.0218 is used for installations of No.
04250 to replace obsolete lighting units.
Standards for post top mounting of No.04250 maybe secured from post or pole manufacturers.
Shields
Metal inner shields Sd-51 are available for use on
stations near residential properties. Shields can be
ordered with new fixtures, or purchased separately andinstalled in existing fixtures. In final assemblies, shieldsmay be rotated in fixtures to the most effective positioru.
Cat.No.
o4250
Lam pWattage
400W Clear l,.4ercury or500 lnc.
Dimensions in lnchesDiam- Depth Termination
Slip fit for1L/2" pipe
1Y, pipe threadto 1% slip fit
r6'h
Span Net Wgt.Lbs, Each
23
0876 (Bracket)
0218 (Adapter) Converts old style O871-Tto 0876 Bracket.
Sd-51 (Metal Shield)
18Y, min.20 max.
180"-11Y2" deep
2O3/a 5
Y2
Y2 o
llp,lnp"h"pneir#fi*'{rx'Hiriih#*.ii*nqC,","r,::"T'":T:"
Pri.red . usa. 7292 1