Grid Design - New Mexico Institute of Mining and...
Transcript of Grid Design - New Mexico Institute of Mining and...
![Page 1: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/1.jpg)
Grid Design
Match to objective of study
tank 1D Radial
Cross-sectional
1D
3D2D radial
Areal
Mattax & Dalton
![Page 2: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/2.jpg)
Criteria for selecting gridblock size
1. Able to identify saturations and pressures at specific locations and times
Desired location
GridblockExisting wells
≥ 3 blocks between locations
![Page 3: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/3.jpg)
Criteria for selecting gridblock size2. Adequately represent the geometry/geology and
physical properties of the reservoir
Ertekin,et al.
![Page 4: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/4.jpg)
Criteria for selecting gridblock size
Structure Map andOverlying grid
Mattax & Dalton
![Page 5: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/5.jpg)
Criteria for selecting gridblock size
Malhotra
Malhotra
![Page 6: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/6.jpg)
Criteria for selectinggridblock size
3. Sufficient to describe the dynamics
a. Able to describe pressures as f(t)
b. Able to follow front locations and movement
c. Able to correctly represent well behavior
Mattax & Dalton
![Page 7: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/7.jpg)
Criteria for selecting gridblock size
4. Correctly model the reservoir fluid mechanics; for example: coning, displacement
5. Compatible with the mathematics of the simulator
![Page 8: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/8.jpg)
Numerical Dispersion• Artifact of numerical analysis techniques• Can cause severe distortions in simulations,
especially in rapid saturation changes
x
Sw
x
Sw
1 432
If upstream mobility, then water will flowFrom Blocks 2 to 3. Next time step, waterFlows from 3 to 4.
![Page 9: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/9.jpg)
Numerical Dispersion• Effect is to decrease displacement efficiency at
breakthrough• Most serious for favorable mobility ratios• Tends to smear the front
Mattax & Dalton
![Page 10: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/10.jpg)
Gridsize Guidelines
• No general rule for proper cell size• Perform sensitivity analysis• Rule of thumb
– 3 to 5 blocks between producers– 5 to 10 between producers/injectors
![Page 11: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/11.jpg)
Limiting Numerical Dispersion1. Increase number of gridblocks2. Improved upstream, mobility weighting3. Apply pseudofunctions
relative permeability curves in areal models are modified to restrict the movement of the displacing phase until saturation reaches the finely gridded simulation value.
4. Finite Element Modelling (FEM)
![Page 12: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/12.jpg)
Grid Orientation Effect• Performance influenced by the orientation of the
grid relative to the well locations.• Multi-dimensional, multiphase problem• Important when M displacing phase >> M displaced phase
A
B
-flow path from Well B longer,Thus front will arrive later
- but sweep efficiency greater…Higher oil recovery
![Page 13: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/13.jpg)
Grid Orientation Effect
Diagonal model
Parallel model
![Page 14: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/14.jpg)
Grid Orientation EffectCase I: Unit mobility, diagonal grid
PVinj0.5
1.0
0.41.5
- Gridblock size (Δx) variedFrom 0.05 to 0.20.
- Results insensitive to numberOf gridblocks
PVre
c
![Page 15: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/15.jpg)
Grid Orientation EffectCase II: Unit mobility, parallel grid
PVinj0.5
1.0
0.41.5
-Oil recovery increases as gridblock size decreases,
-but is less than diagonal model for all grid spacings
Increasing
Δx
PVre
c
![Page 16: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/16.jpg)
Grid Orientation EffectCase III: Unfavorable mobility ratio (10:1)
PVinj0.5
1.0
0.41.5
IncreasingΔx
Diagonal
Parallel9 point formulation
PVre
c
![Page 17: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/17.jpg)
Grid Orientation Effect
• For simulations with favorable to slightly favorable mobility ratio…grid orientation effect can be reduced by refining the grid.
• Diagonal orientation less likely to introduce distortion.
• Grid orientation effect more pronounced for unfavorable mobility ratios (10:1)
![Page 18: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/18.jpg)
Grid Orientation Effect
Strike curvature map
kmax
kmin
kmax
kmin
kmax
kmin
A
B
C
Robinson
Orient grid parallel to principal directions of permeability……. if known..
![Page 19: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/19.jpg)
Approaches to Reduce Grid Orientation Effect
1. Nine point formulation2. Initialize with high displacing phase
saturation near injection wells3. Two-point upstream weighting4. Curvilinear coordinates5. Triangular grid systems6. F.E.M.
![Page 20: Grid Design - New Mexico Institute of Mining and Technologypetro/faculty/Engler571/simulation-3-griddesign.pdf · Criteria for selecting gridblock size 2. Adequately represent the](https://reader033.fdocuments.in/reader033/viewer/2022051722/5aa7b1947f8b9ab8228c9baa/html5/thumbnails/20.jpg)
Selection of Timestep• Selection function of study; e.g. single well
pressure test vs. full field reservoir simulation• Consequences of large time step
– Incorrect mobilities– Numerical dispersion– Physics of system not represented
• Initialization• Automatic timestep
– Controlling parameters are pressure and saturation change