Nokia MetroSite EDGE Base Station
Functional Test Specification for STIRC in BTS SW Release CXM5
DN0691271Issue 1-0 en
©Nokia CorporationNokia Proprietary and Confidential
1 (21)
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 2/21
Functional Test Specification for STIRC in BTS SW Release CXM5
The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This document is intended for theuse of Nokia's customers only for the purposes of the agreement under which the document issubmitted, and no part of it may be reproduced or transmitted in any form or means withoutthe prior written permission of Nokia. The document has been prepared to be used by
professional and properly trained personnel, and the customer assumes full responsibilitywhen using it. Nokia welcomes customer comments as part of the process of continuousdevelopment and improvement of the documentation.
The information or statements given in this document concerning the suitability, capacity, orperformance of the mentioned hardware or software products cannot be considered bindingbut shall be defined in the agreement made between Nokia and the customer. However,Nokia has made all reasonable efforts to ensure that the instructions contained in thedocument are adequate and free of material errors and omissions. Nokia will, if necessary,explain issues which may not be covered by the document.
Nokia's liability for any errors in the document is limited to the documentary correction of errors. NOKIA WILL NOT BE RESPONSIBLE IN ANY EVENT FOR ERRORS IN THISDOCUMENT OR FOR ANY DAMAGES, INCIDENTAL OR CONSEQUENTIAL (INCLUDINGMONETARY LOSSES), that might arise from the use of this document or the information in it.
This document and the product it describes are considered protected by copyright accordingto the applicable laws.
NOKIA logo is a registered trademark of Nokia Corporation.
Other product names mentioned in this document may be trademarks of their respectivecompanies, and they are mentioned for identification purposes only.
Copyright ©Nokia Corporation 2007. All rights reserved.
Hereby, Nokia Corporation declares that this Nokia Base Station is in compliance withthe essential requirements and other relevant provisions of Directive: 1999/5/EC. Theproduct is marked with the CE marking and Notified Body number according to theDirective 1999/5/EC.
2 (21) ©Nokia CorporationNokia Proprietary and Confidential
DN0691271Issue 1-0 en
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 3/21
Contents
Contents
1 About this document .............................................................................5
1.1 Scope.......................................................................................................5 1.2 Hardware requirements............................................................................6 1.3 Software requirements .............................................................................7 1.4 Specialist test equipment requirements ...................................................7
2 Test cases ...............................................................................................8 2.1 Enable/Disable STIRC from the BSC.......................................................8 2.2 Reset from the BSC ...............................................................................10 2.3 Reset from BTS Manager.......................................................................11 2.4 Alarm handling .......................................................................................12 2.5 TRX Test and TRX Loop Test................................................................13
Appendix A: RF set-up to establish known C/I condi tions ..............18
DN0691271Issue 1-0 en
©Nokia CorporationNokia Proprietary and Confidential
3 (21)
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 4/21
Functional Test Specification for STIRC in BTS SW Release CXM5
4 (21) ©Nokia CorporationNokia Proprietary and Confidential
DN0691271Issue 1-0 en
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 5/21
About this document
1 About this document 1.1 Scope
This document incorporates functional test phase and defines the test cases for
the Space-Time Interference Rejection Combining (STIRC) feature of the BTS
software release CXM5 for MetroSite. The test cases are used to verify that the
BTS configured with the feature works as specified.
Note 1.
The BSC version to be used is S12 unless otherwise specified.
Note 2.
At the BSC, Base Transceiver Stations (sites) are seen as BCFs. Sectors are
referred to as BTS. This principle is followed in the test Description in this
document.
Note 3.
All test cases are performed with BTS Manager connected, unless otherwise
stated.
Note 4.
For all tests that require TRX test to be run, the PMAX value should be set as
maximum (that is, 0).
Note 5.
This feature is only supported by EDGE TRXs of MetroSite.
DN0691271Issue 1-0 en
©Nokia CorporationNokia Proprietary and Confidential
5 (21)
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 6/21
Functional Test Specification for STIRC in BTS SW Release CXM5
Note 6.
(HS)CSD rig is a setup of laptops and phones to enable the testing of these
features.
Note 7.
The IR/LA rig is a setup of equipment that allow introduction of interference on
the air interface so that bad conditions on the RF path can be simulated.
1.2 Hardware requirements
Base stations 3 MetroSite cabinets, 12 EDGE TRXs, 4 GSM TRXs.
Other Network Elements
• BSC
• Core Network with GPRS and EDGE capabilities
Mobile stations Feature Specific options
Speech channels FR, HR, EFR
Single data channels 9600, 14400 Non-Transparent
Multi-slot data channels 9600 or 14400 Non-Transparent using 1+1, 2+2 or 3+1timeslots
GPRS Class B and Class C, Multi, PBCCH Support
EGPRS Class B and Class C, Multi, PBCCH Support
EGPRS Channel Request on PBCCH and BCCH
Adaptive Multi-Rate AMR FR and HR
PC applications
• Internet browser
• FTP, UDP software
• Terminal Emulator
6 (21) ©Nokia CorporationNokia Proprietary and Confidential
DN0691271Issue 1-0 en
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 7/21
About this document
1.3 Software requirements
• SiteWizard 5.0
• Latest available Pre-Release of CXM5 containing the feature under test.
1.4 Specialist test equipment requirements
The following test equipment is required in some test cases:
• 8PSK & GMSK capable RF TA Rigs
• IR/LA Rig
• Assortment of combiners
• Attenuators
• Terminators
• Signal generator
• Spectrum analyser
• GSM Protocol Analyser
• GPRS/EGPRS laptop
• (HS)CSD rig
• GSM Analyzer
DN0691271Issue 1-0 en
©Nokia CorporationNokia Proprietary and Confidential
7 (21)
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 8/21
Functional Test Specification for STIRC in BTS SW Release CXM5
2 Test cases
2.1 Enable/Disable STIRC from the BSC
The purpose of the following test cases is to confirm that the STIRC feature can
be enabled and disabled successfully from the BSC.
Equipment and BTS set-up
Use the configuration stated below under the test case.
Input Expected Output
1. Enable STIRC in the sector with thefollowing MML command:
ZEQM: BTS=<BTS I D>: STI RC=Y;
STIRC is enabled successfully.
2. Abis interface is monitored. BTS_CONF_DATA is sent to the BTS by theBSC, with the STIRC mode enabled.
The BTS sends ACK, on BTS_BSC_ACK to theBSC.
3. Trace master is used to monitor the UC-DSP traces.
STIRC information is sent to the EQDSP in theINI message for both the sectors.
4. Make a call as defined in the table.
In case of a GPRS call, transfer a file of 200kb in UL and DL direction.
Call is successful.
In case of GPRS, file transfer is successful.
5. Disable STIRC in the sector with thefollowing MML command:
ZEQM: BTS=<BTS I D>: STI RC=N;
STIRC is disabled successfully.
8 (21) ©Nokia CorporationNokia Proprietary and Confidential
DN0691271Issue 1-0 en
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 9/21
Test cases
Input Expected Output
6. Abis interface is monitored. BTS_CONF_DATA is sent to the BTS by theBSC, with the STIRC mode enabled.
The BTS sends ACK, on BTS_BSC_ACK to theBSC.
7. Trace master is used to monitor the UC-DSP traces
STIRC information is sent to the EQDSP in theINI message for both the sectors.
8. Make calls as defined in the table on all the TRXs.
In case of a GPRS call, transfer a file of 200kb.
Calls are successful.
In case of GPRS, file transfer is successful.
Case Ref. Type of Call Configuration
355736.05 FR Any, RDIV=N, RF-Hopping355736.06 HR 2+2
355736.07 GPRS 4 OMNI
355736.08 FR 4+4+4 chaining configuration
Input Expected Output
1. Make anFR call. Call is successful.
The call is ongoing throughout the test case.
2. Enable STIRC in the sector with thefollowing MML command:
ZEQM: BTS=<BTS I D>: STI RC=Y;
Abis interface is monitored.
STIRC is enabled successfully.BTS_CONF_DATA is sent to the BTS by the BSCwith the STIRC mode enabled.
The BTS sends ACK on BTS_BSC_ACK to theBSC.
The call is ongoing and the enabling of STIRCdoes not affect the ongoing call. This means thatthe call is not dropped and there are no additionaldisturbing sounds heard at the receiving end.
3. Trace master is used to monitor the UC-DSP traces
STIRC information is sent to the EQDSP in theINI message for both sectors.
DN0691271Issue 1-0 en
©Nokia CorporationNokia Proprietary and Confidential
9 (21)
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 10/21
Functional Test Specification for STIRC in BTS SW Release CXM5
Input Expected Output
4. Disable STIRC in the sector with thefollowing MML command:
ZEQM: BTS=<BTS I D>: STI RC=N;
Abis interface is monitored.
STIRC is disabled successfully.
BTS_CONF_DATA is sent to the BTS by the BSCwith the STIRC mode disabled.
The BTS sends ACK, on BTS_BSC_ACK to theBSC.
The call is ongoing and the disabling of STIRCdoes not affect the ongoing call. This means thatthe call is not dropped and there are no additionaldisturbing sounds heard at the receiving end.
5. Trace master is used to monitor the UC-DSP traces
STIRC information is sent to the EQDSP in theINI message for both sectors.
Case Ref. Configuration
365489.02 EDGE
2.2 Reset from the BSC
The purpose of the following test cases is to ensure that the STIRC feature is
functioning correctly after reset from BSC or from BTS Manager.
Equipment and BTS set-up
Use the configuration stated below under the test case.
Input Expected Output
1. Enable STIRC for all the sectors with thefollowing MML command:
ZEQM: BTS=<BTS I D>: STI RC=Y;
STIRC is enabled successfully.
2. Abis interface is monitored. BTS_CONF_DATA is sent to the BTS by theBSC with the STIRC mode enabled.
The BTS sends ACK on BTS_BSC_ACK to the
BSC.
3. Trace master is used to monitor the UC-DSP traces.
STIRC information is sent to the EQDSP in theINI message for both sectors.
4. Perform an action as listed in the lower partof this table:
• BCF lock/unlock
• Sector lock/unlock
• OMU reset
The action is performed successfully.
10 (21) ©Nokia CorporationNokia Proprietary and Confidential
DN0691271Issue 1-0 en
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 11/21
Test cases
Input Expected Output
5. Make a speech call in all the sectors. Calls are successful.
Case Ref Configuration Hopping Action355758.04 4+4+4 chain Non BCF lock/unlock
355758.05 2+2 EDGE BB Sector Lock/unlock
2.3 Reset from BTS Manager
Purpose:
The purpose of this test case is to ensure that the STIRC feature is functioningcorrectly after reset from BTS Manager.
Equipment and BTS set-up
Use the configuration stated below under the test case.
Input Expected Output
1. Enable STIRC for all the sectors with thefollowing MML command:
ZEQM: BTS=<BTS I D>: STI RC=Y;
STIRC is enabled successfully.
2. Abis interface is monitored. BTS_CONF_DATA is sent to the BTS by theBSC with the STIRC mode enabled.
The BTS sends ACK on BTS_BSC_ACK to theBSC.
3. Trace master is used to monitor the UC-DSP traces.
STIRC information is sent to the EQDSP in theINI message for the sector that was reset.
4. Make speech calls on all TRXs. Calls are successful.
5. In BTS Manager, perform an action aslisted in the lower part of this table:
• BCF reset
• Sector reset
• Sector block/unblock
• TRX reset
The action is performed successfully and all the TRXs are in WO state.
There are no unexpected alarms.
6. Make speech calls on all TRXs. Calls are successful.
Case Ref Configuration Hopping Action
DN0691271Issue 1-0 en
©Nokia CorporationNokia Proprietary and Confidential
11 (21)
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 12/21
Functional Test Specification for STIRC in BTS SW Release CXM5
Input Expected Output
365507.05 4 OMNI Non BCF reset
365507.06 2+2 BB Sector Reset365507.07 4 OMNI Non Sector Block/unblock
365507.08 2+2 Non TRX Reset
2.4 Alarm handling
Purpose:
The purpose of the following test cases is to verify that the STIRC feature
cannot be enabled for a GSM site and the correct alarm is reported.
Equipment and BTS set-up
Use the configuration stated below under the test case.
Input Expected Output
1. Enable STIRC with the following MMLcommand:
ZEQM: BTS=<BTS I D>: STI RC=Y;
Alarm 7606 NON-EDGE TRX ACCIDENTALLYUSED IN EDGE CAPABLE MODE is reported onBTS Manager and on BSC for all the GSM TRXsexcept for one TRX.
Alarm 7603 appears for the sector.
2. Reset the sector. Alarms are cancelled and then reported again.
3. Disable STIRC with the following MMLcommand:
ZEQM: BTS=<BTS I D>: STI RC=N;
All the alarms are cancelled and the BTS comesup in WO state.
4. Make speech calls. Calls are successful.
Case Ref Configuration
355752.03 GSM
Input Expected Output
Any configuration is used. The BCF is in Supervisory state.
1. Enable STIRC with the following MMLcommand:
ZEQM: BTS=<BTS I D>: STI RC=Y;
STIRC is enabled successfully.
12 (21) ©Nokia CorporationNokia Proprietary and Confidential
DN0691271Issue 1-0 en
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 13/21
Test cases
Input Expected Output
2. Abis interface is monitored. BTS_CONF_DATA is sent to the BTS by theBSC, with the STIRC mode as enabled.
The BTS sends ACK, on BTS_BSC_ACK to theBSC.
3. Trace master is used to monitor the UC-DSP traces.
STIRC information is sent to the EQDSP in theINI message for both sectors.
4. Replace the EDGE TRX by a GSM TRX. Alarm 7606 NON-EDGE TRX ACCIDENTALLYUSED IN EDGE CAPABLE MODE is reported onBTS Manager and on the BSC for the TRX.
5. Lock/unlock the sector. Alarm is cancelled and then reported again.
6. Disable STIRC with this MML command:
ZEQM: BTS=<BTS I D>: STI RC=N;7. A-bis interface is monitored. BTS_CONF_DATA is sent to the BTS by the
BSC, with the STIRC mode disabled.
The BTS sends ACK, on BTS_BSC_ACK to theBSC.
8. Trace master is used to monitor the UC-DSP traces.
STIRC information is sent to the EQDSP in theINI message for both sectors.
9. Lock/unlock the sector. All the alarms are cancelled and the BTS comesup in WO state.
10. Make speech calls. Calls are successful.
Case Ref Configuration
355752.05 EDGE
2.5 TRX Test and TRX Loop Test
Purpose:
The purpose of the following tests is to check that the TRX Test can be
executed successfully on the TRXs of a STIRC-enabled sector.
Acceptable test results
The acceptable test results for this test are:
• BER = 0%
• RX Sensitivity:
− -110.5 dBm (or better) for GSM 900 and GSM 800
− -111 dBm (or better) for GSM 1800 and GSM 1900
DN0691271Issue 1-0 en
©Nokia CorporationNokia Proprietary and Confidential
13 (21)
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 14/21
Functional Test Specification for STIRC in BTS SW Release CXM5
• The GMSK sensitivity is typically -111 to -113 dBm, MCS-5 is -107 to -
109 dBm and MCS-9 is -97 to -99 dBm.
• PMAX value should be set as maximum (that is, 0).
• The threshold values of TRX performance test need to be defined as thedefault values. The default threshold or TRX performance test values for
MetroSite are:
Transmitted Metro Power (PWRM) = 30 dBm
Transmitted Metro HP Power (PWRH) = 37 dBm
BER (BER) = 0.2000%
RX Sensitivity (MSENS) = -100 dBm
At the BSC, the current threshold values of TRX performance test can be
verified using the following MML command:ZUCV: TRP, CURRENT;
If the current threshold values differ from the default ones, they should be
modified with the following MML command:
ZUCV: TRP, MODI FY: PWRU=<pwr u_val >, BER=<ber _val >, MSENS=<msens_ val >;
The expected range of TX power level from the TRX Test is:
transmitted power level dBm – PMAX + 4dBm
Note 8.
When the test is started from BTS Manager, alarm 7615 RTS IS IN TEST USE
for the used TS is started.
When BTS Manager finishes the test, alarm 7615 RTS IS IN TEST USE for the
used TS is cancelled.
The alarm may not be included in the alarm history at the BSC as the BSC uses
time-window based filtering for alarm reporting. That is, if an alarm is started
and cancelled within 10 seconds.
Note 9.
When running the TRX Test from the BSC, only MCS-5 is supported with 8-
PSK modulation.
14 (21) ©Nokia CorporationNokia Proprietary and Confidential
DN0691271Issue 1-0 en
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 15/21
Test cases
Input Expected Output
BCF is in Supervisory state.
1. For an EDGE sector, configure DAP andEGENA. EGENA is configured successfully.
2. Enable STIRC for both sectors with thefollowing MML command:
ZEQM: BTS=<BTS I D>: STI RC=Y;
STIRC is enabled successfully.
3. Abis interface is monitored. BTS_CONF_DATA is sent to the BTS by theBSC with the STIRC mode enabled.
The BTS sends ACK, on BTS_BSC_ACK to theBSC.
4. See the traces using Trace master. The INI message contains the STIRC option as
enabled.5. Make a call using the TRX being tested. Call is successful.
6. A TRX test is started from the BSC usingthe following MML command:
ZUBS
for 8-PSK modulation method.
The test is started.
7. The test results are checked with thefollowing MML command:
ZUBP
The used TX power level is verified withthe Spectrum Analyser.
The test is successful and the test results areacceptable, as defined in the explanation abovethis table.
Note:
The used TX power level is the same as theBCCH TX power level.
The test is not started for control channels orchannels with an active call.
The test takes no more than 5 seconds.
The call is not affected, that is, the call is notdropped and there are no additional disturbingsounds heard at the receiving end.
8. The test is repeated for every TSs in bothBCCH and non-BCCH TRXs in both
sectors. The colour of unit LEDs is verified at theBTS and the BTS Manager equipmentview.
The test is started for idle channels.
The colour of the TRX LEDs at the BTS remains
green during the test.
The test is not started for control channels orchannels with an active call, and the colour of the TRX at the BTS and BTS Manager remainsgreen.
Case Ref. Configuration
355759.02 2+2
DN0691271Issue 1-0 en
©Nokia CorporationNokia Proprietary and Confidential
15 (21)
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 16/21
Functional Test Specification for STIRC in BTS SW Release CXM5
Input Expected Output
BCF is in Supervisory state.
1. For the EDGE sector, configure DAP andEGENA. EGENA is configured successfully.
2. Enable STIRC for both sectors with thefollowing MML command:
ZEQM: BTS=<BTS I D>: STI RC=Y;
STIRC is enabled successfully.
3. Abis interface is monitored. BTS_CONF_DATA is sent to the BTS by the BSCwith the STIRC mode enabled.
The BTS sends ACK, on BTS_BSC_ACK to theBSC.
4. See the traces using Trace master. The INI message contains the STIRC option as
enabled.5. Make a call using the TRX being tested. Call is successful.
6. In BTS Manager, select Tests Æ TRXTest.
Select TCH TRX and Radio Timeslot. Thetest is started on non-BCCH TRX of all TSs.
Verify the colour of unit LEDs from the BTSand BTS Manager Equipment view.
The test is started.
• When the test is started, the alarm 7615RTS IS IN TEST USE for the used TS andfor its partner TS is displayed.
• When the test is finished, the alarm 7615RTS IS IN TEST USE for the used TS andits partner TS is cancelled.
The colour of the TRX LEDs at the BTS remainsgreen during the test.
7. Check the test results. The test results are acceptable, as defined in theexplanation above this table.
8. With EDGE configuration, repeat the testwith 8-PSK MCS5 and 8-PSK MCS9Modulation Methods.
Case Ref. Configuration
355759.04 2+2
Purpose:
The purpose of the following test case is to check that the TRX Loop Test can
be executed successfully on the TRXs of a STIRC-enabled sector.
Input Expected Output
1. Enable STIRC in the sector with thefollowing MML command:
ZEQM: BTS=<BTS I D>: STI RC=Y;
STIRC is enabled successfully.
16 (21) ©Nokia CorporationNokia Proprietary and Confidential
DN0691271Issue 1-0 en
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 17/21
Test cases
Input Expected Output
2. Abis interface is monitored. BTS_CONF_DATA is sent to the BTS by the BSCwith the STIRC mode as enabled.
The BTS sends ACK, on BTS_BSC_ACK to theBSC.
3. See the traces using Trace master. The INI message contains the STIRC option asenabled.
4. In BTS Manager, select Tests Æ TRXLoop Test.
Select TRX Number, time slot, Loop backpoints and modulation method.
The test is started.
5. Stop the TRX Loop Test is stopped in BTSManager.
Test is stopped and the results are acceptable, asdefined in the explanation above this table.
6. Repeat the test for GMSK CS1 and 8PSK MCS9.
Case Ref. Configuration
365522.02 Any EDGE
DN0691271Issue 1-0 en
©Nokia CorporationNokia Proprietary and Confidential
17 (21)
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 18/21
Functional Test Specification for STIRC in BTS SW Release CXM5
Appendix A: RF set-up to establish known C/I condit ions
The figures on the following pages illustrate the MetroSite RF set-up for uplink
quality measurements for main receiver and diverse receiver.
18 (21) ©Nokia CorporationNokia Proprietary and Confidential
DN0691271Issue 1-0 en
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 19/21
Appendix A: RF set-up to establish known C/I conditions
DN0691271Issue 1-0 en
©Nokia CorporationNokia Proprietary and Confidential
19 (21)
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 20/21
Functional Test Specification for STIRC in BTS SW Release CXM5
20 (21) ©Nokia CorporationNokia Proprietary and Confidential
DN0691271Issue 1-0 en
8/22/2019 Functional Test STIRC DN0691271x1x0xen
http://slidepdf.com/reader/full/functional-test-stirc-dn0691271x1x0xen 21/21
Appendix A: RF set-up to establish known C/I conditions
DN0691271 ©Nokia Corporation 21 (21)