PorchDining / Family
800
12
00
Roof timbers and wall plate to be secured to walls with galvanized straps spaced at maximum 2m centres with a minimum length of 1.2M. To be fixed vertically to masonry walls with mechanical fixings suitable for design requirements in accordance with manufactures details. Lowest fixing within 150mm of bottom of strap.
Each rafter fixed to wall plate with framing anchors or skew nails.
Nogging
Pack
Internal block wall.
Galvanised steel restraint straps should be provided at roof level. To bespaced at Max. 2 metre centres, fixed to the first three rafters.
Strap turned over uncut block.
Form roof valleys on 19mm thick exterior qualityplywood including tilt fillets, down edges & tile cutedges.Gap between tile edges to be 225mm min wide, usingcode 4 lead work. All lead work to be in accordancewith the lead sheet Association guidelines.
19mm timber support board cut betweenrafters and supported on 38 x 25mmbattens nailed to rafters. Top surface ofsupport board must be flush with top oftimber rafters.
Dovetail GRP Valley nailed to support battens. Timber rafters
Underlay turned up onto supportbatten
38 x 19mm S.W. batten supportedon valley support board
38 x 19mm S.W. batten supportedon valley support board
PRIOR TO COMMENCEMENT, LOCATE EXISTING FOUL DRAINS. SITE CHECK
EXISTING INVERT LEVELS AND SUITABLE FALLS CAN BE ACHIEVED. AGREE FINAL IC /
DRAIN RUNS ON SITE.
FOUNDATIONS SHOULD BE CARRIED DOWN TO DEPTH OF ANY DRAINS IN CLOSE PROXIMITY
EXAMPLE DRAWING
Planning Permission
RISK OF FALLS.WORKING PLATFORMS OR OTHER PRECAUTIONS REQUIRED DURING
CONSTRUCTION
FRONT ELEVATIONAS EXISTING
SIDE ELEVATIONAS EXISTING
VERTICAL STRAPPING ATEAVES PERSPECTIVE (NTS)
ROOF STRAPPED TO GABLE WALL PERSPECTIVE (NTS)
GROUND FLOOR PLANAS PROPOSED
FRONT ELEVATIONAS PROPOSED
SIDE ELEVATIONAS PROPOSED
REAR ELEVATIONAS EXISTING
REAR ELEVATIONAS PROPOSED
www.extension-design-plans.co.uk
Two Storey ExtensionBuilding Regulations
SECTION A-A SECTION B-B