FRONT ELEVATION - LoopNet...front elevation 3/16" = 1'-0" rear elevation 3/16" = 1'-0" a1.1 left &...
Transcript of FRONT ELEVATION - LoopNet...front elevation 3/16" = 1'-0" rear elevation 3/16" = 1'-0" a1.1 left &...
A1.0
FRO
NT
& REA
R E
LEVS.
© 2019 BRANCH CONCEPTS, LLC.
ALL RIGHTS RESERVED
1. The contractor shall perform all
work in accordance with applicable
national, state and local codes.
2. The contractor shall verify all site
conditions and dimensions before
construction. Any discrepancies
shall be reported to Branch
Concepts for justification and/or
corrections before proceeding with
work. Contractor shall assume
responsibility for errors that are not
reported.
3. All dimensions should be read or
calculated and never scaled.
4. All wood, concrete and steel
structural members shall be of
proper grade and quality and meet
all national, state and local building
codes.
5. The contractor shall be
responsible for all structural
members and conditions to meet all
local codes and insure a quality and
safe structure.
6. Caution must be exercised in
making modifications to this plan.
Only a qualified designer, Architect,
Contractor, or Structural Engineer
should attempt modifications. Minor
changes in one area could lead to
major problems in other areas.
PLOT SCALE: N/A
PLOT DATE: 08/12/19
PLOT TIME: 11:50 AM
SEAL:
PAGE:
(678)
523.0780
TH
E W
AL
K @
M
AR
S H
IL
L
BU
IL
DIN
G #
14
00
49
00
IV
EY
R
OA
D
AC
WO
RT
H, G
A 3
01
01
FRONT ELEVATION3/16" = 1'-0"
REAR ELEVATION3/16" = 1'-0"
A1.1
LEFT
& R
IGHT
ELEV
S.
© 2019 BRANCH CONCEPTS, LLC.
ALL RIGHTS RESERVED
1. The contractor shall perform all
work in accordance with applicable
national, state and local codes.
2. The contractor shall verify all site
conditions and dimensions before
construction. Any discrepancies
shall be reported to Branch
Concepts for justification and/or
corrections before proceeding with
work. Contractor shall assume
responsibility for errors that are not
reported.
3. All dimensions should be read or
calculated and never scaled.
4. All wood, concrete and steel
structural members shall be of
proper grade and quality and meet
all national, state and local building
codes.
5. The contractor shall be
responsible for all structural
members and conditions to meet all
local codes and insure a quality and
safe structure.
6. Caution must be exercised in
making modifications to this plan.
Only a qualified designer, Architect,
Contractor, or Structural Engineer
should attempt modifications. Minor
changes in one area could lead to
major problems in other areas.
PLOT SCALE: N/A
PLOT DATE: 08/12/19
PLOT TIME: 11:50 AM
SEAL:
PAGE:
(678)
523.0780
TH
E W
AL
K @
M
AR
S H
IL
L
BU
IL
DIN
G #
14
00
49
00
IV
EY
R
OA
D
AC
WO
RT
H, G
A 3
01
01
LEFT ELEVATION3/16" = 1'-0"
RIGHT ELEVATION3/16" = 1'-0"
RESTROOM
RESTROOM
RESTROOM
RESTROOM
UNIT #1 UNIT #2
lower levelA2.1
PRO
POSED
FLO
ORPL
AN
PROPOSED FLOOR PLAN - LOWER LEVEL3/16" = 1'-0"
© 2019 BRANCH CONCEPTS, LLC.
ALL RIGHTS RESERVED
1. The contractor shall perform all
work in accordance with applicable
national, state and local codes.
2. The contractor shall verify all site
conditions and dimensions before
construction. Any discrepancies
shall be reported to Branch
Concepts for justification and/or
corrections before proceeding with
work. Contractor shall assume
responsibility for errors that are not
reported.
3. All dimensions should be read or
calculated and never scaled.
4. All wood, concrete and steel
structural members shall be of
proper grade and quality and meet
all national, state and local building
codes.
5. The contractor shall be
responsible for all structural
members and conditions to meet all
local codes and insure a quality and
safe structure.
6. Caution must be exercised in
making modifications to this plan.
Only a qualified designer, Architect,
Contractor, or Structural Engineer
should attempt modifications. Minor
changes in one area could lead to
major problems in other areas.
PLOT SCALE: N/A
PLOT DATE: 08/12/19
PLOT TIME: 11:50 AM
SEAL:
PAGE:
(678)
523.0780
TH
E W
AL
K @
M
AR
S H
IL
L
BU
IL
DIN
G #
14
00
49
00
IV
EY
R
OA
D
AC
WO
RT
H, G
A 3
01
01
UNIT #3 UNIT #4 UNIT #5
A2.2
PRO
POSED
FLO
ORPL
AN
PROPOSED FLOOR PLAN - UPPER LEVEL3/16" = 1'-0"
© 2019 BRANCH CONCEPTS, LLC.
ALL RIGHTS RESERVED
1. The contractor shall perform all
work in accordance with applicable
national, state and local codes.
2. The contractor shall verify all site
conditions and dimensions before
construction. Any discrepancies
shall be reported to Branch
Concepts for justification and/or
corrections before proceeding with
work. Contractor shall assume
responsibility for errors that are not
reported.
3. All dimensions should be read or
calculated and never scaled.
4. All wood, concrete and steel
structural members shall be of
proper grade and quality and meet
all national, state and local building
codes.
5. The contractor shall be
responsible for all structural
members and conditions to meet all
local codes and insure a quality and
safe structure.
6. Caution must be exercised in
making modifications to this plan.
Only a qualified designer, Architect,
Contractor, or Structural Engineer
should attempt modifications. Minor
changes in one area could lead to
major problems in other areas.
PLOT SCALE: N/A
PLOT DATE: 08/12/19
PLOT TIME: 11:50 AM
SEAL:
PAGE:
(678)
523.0780
TH
E W
AL
K @
M
AR
S H
IL
L
BU
IL
DIN
G #
14
00
49
00
IV
EY
R
OA
D
AC
WO
RT
H, G
A 3
01
01