Flange- lok Installation Instructions

24
Flange-lok Installation Instructions Quick Installation Guide 00825-0200-4809 rev. DB

description

Flange- lok Installation Instructions. Quick Installation Guide 00825-0200-4809 rev. DB. Drill the Hole into the Pipe Using a Drill Bit or Hole Saw. Tag with correct drill hole size attached to the Annubar. Clean the Area with a Grinder to Prepare for the Surface for Welding . - PowerPoint PPT Presentation

Transcript of Flange- lok Installation Instructions

Page 1: Flange- lok  Installation Instructions

Flange-lok Installation InstructionsQuick Installation Guide00825-0200-4809 rev. DB

Page 2: Flange- lok  Installation Instructions

Drill the Hole into the Pipe Using a Drill Bit or Hole Saw

Tag with correct drill hole size attached to the Annubar

Page 3: Flange- lok  Installation Instructions

Clean the Area with a Grinder to Prepare for the Surface for Welding

Page 4: Flange- lok  Installation Instructions

Mounting Should be Welded So the Bolt Holes are Parallel to Pipe The mounting

hardware should be gapped 1-/16th inch for welding– Use weld rod to do this

It should also be centered over the drilled hole

Page 5: Flange- lok  Installation Instructions

Tack Weld the Mounting Hardware with 4 Equal Length Tacks Tack weld anywhere on

the mounting hardware Then again directly across

from the first tack weld Then on the other 2 sides

2

1

3

Page 6: Flange- lok  Installation Instructions

Check to See that the Mounting Hardware is Level and Square If it’s not, use a

rubber mallet to lightly adjust the hardware and recheck

Page 7: Flange- lok  Installation Instructions

Verify that the ODF Dimension Matches What is Listed in the QIG The ODF is the dimension from outside pipe diameter to face of flange

Page 8: Flange- lok  Installation Instructions

Complete a Continuous Weld Around the Perimeter of the Unit

Page 9: Flange- lok  Installation Instructions

Using a Gasket, Install the Flange on the Mounting Hardware

Page 10: Flange- lok  Installation Instructions

Tighten the Studs in Nuts in a Cross Pattern Until Appropriately Torqued

Page 11: Flange- lok  Installation Instructions

Insert Studs into the Flange-lok Body

Page 12: Flange- lok  Installation Instructions

Mark the End of the Sensor With a Felt Tip Marker Do not mark if order with special cleaning (Option Code P2, PA)

Page 13: Flange- lok  Installation Instructions

Insert the Flowmeter Until the Tip Contacts the Opposite Side Pipe WallRotate Annubar back and forth.

Page 14: Flange- lok  Installation Instructions

Remove the Flowmeter and Verify the Sensor Tip Made ContactSome of the marker should have been rubbed off.

Page 15: Flange- lok  Installation Instructions

Align the Flow Arrow and Insert the Annubar

Page 16: Flange- lok  Installation Instructions

Insert a Packing Ring Underneath the Compression Plate and the FollowerThe split in the packing ring should face one of the three studs. Use the Compression Plate and Follower to compress the packing into the Pak-lok Body.

Page 17: Flange- lok  Installation Instructions

Packing Goes Below the Compression Plate and Follower

NO!

YES!

NO!

Compression PlateFollower

Weld Ring

Packing

Page 18: Flange- lok  Installation Instructions

The Next 2 Packing Rings should be Inserted so the Split is 120 ۫ Apart

The split in each packing ring should face a different stud which are 120 degrees apart

Page 19: Flange- lok  Installation Instructions

Insert the Second Packing Ring with the Split Facing a Different StudCompress it with the Follower and Compression Plate

Page 20: Flange- lok  Installation Instructions

Insert the Third Packing Ring with the Split Facing a Different StudCompress it with the Follower and Compression Plate

Page 21: Flange- lok  Installation Instructions

Place the Split Ring Washers on the Studs

Page 22: Flange- lok  Installation Instructions

Thread the Nuts onto the Studs

Page 23: Flange- lok  Installation Instructions

Tighten Each Nut ½ Turn in Succession

Page 24: Flange- lok  Installation Instructions

Tightened the Nuts Until the Split-Ring Washers are Flattened

The Split-Ring washers are specially designed to be flat at the appropriate Torque level for the Annubar