2775 SW Bag End Way, Port Orchard, WA 98367 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property.
You may view more detailed information for this home and can make an offer at
http://www.faira.com/listings/11654 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team
Inspection Report for Mr. Stephen MajeskeProperty Address: 2775 SW Bag End Way, Port Orchard, Washington 98367
NW WASHINGTON HOME INSPECTIONS LLC
Carl Liberman License #1758Bainbridge Island, Washington
Table of Contents
Cover Page.................................................................1
Table of Contents ........................................................2
Intro Page ...................................................................3
Significant Issues ........................................................5
Repair & Maintenance Summary ................................6
Future Improvements..................................................9
Complete Wood Destroying Organism InspectionReport .......................................................................10
1 Roof .......................................................................12
2 Attic ........................................................................17
3 Exterior...................................................................19
4 Wall Exteriors.........................................................22
5 Structure ................................................................31
6 Electrical ................................................................33
7 Garage...................................................................37
8 Interior....................................................................40
9 Plumbing ................................................................41
10 Heating.................................................................44
11 Bathrooms............................................................47
12 Kitchen and Built-in Appliances ...........................49
13 Laundry Room .....................................................53
Invoice.......................................................................54
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 2 of 54
Date: 5/7/2018 Time: 01:00 PM Report ID: 180507 B / ICN10323AR001
Property:2775 SW Bag End WayPort Orchard Washington 98367
Customer:Mr. Stephen Majeske
Real Estate Professional:Chris EllisFaira.com
Dear Mr. Majeske,
Thank you for choosing NW WASHINGTON HOME INSPECTIONS LLC for your home inspection needs. I greatlyappreciate the importance of this inspection and have done my utmost to provide you with an organized,sufficiently-detailed, and easy-to-read report.
Three summary reports are provided at the beginning of the report highlighting the most significant findings. TheSignificant Issues Summary includes the most serious issues identified during the inspection. The Repair &Maintenance Summary includes the remainder of those potentially near-term actionable items for you to considerbased on the inspection. Future improvements are provided for your consideration. The results of your StructuralPest Inspection are also summarized in the Complete Wood Destroying Organism Inspection Report, also includedat the beginning of the Home Inspection Report.
The body of the report is organized by system: Roofing, Structure, Electrical, etc. I have included pictures whenpossible. Please review the entire report as there is additional information presented in the body of the report thatmay not be found in the summaries.
If you have any questions regarding your inspection, please feel free to contact me directly at 206.841.9532 or emailme at [email protected]. I look forward to providing future home inspection needs to you, yourfriends, and family.
Warm Regards,
Carl Liberman
Significant Issues ( ) = Items or discoveries indicate that these systems or components may cost significant moneyto correct now or in the near future, or items that require immediate attention to prevent additional damage or eliminatesafety hazards. Further investigation by a specialist and/or subsequent observation may be required.
Repair & Maintenance ( ) = Items or discoveries indicate that these systems or components do not function asintended and/or maintenance is required in the near term. Further investigation by a specialist and/or subsequentobservation may be required.
Future Improvements ( ) = Items or discoveries indicate that these systems or components should be considered forupgrade and/or modernization. Improved safety and/or energy efficiency may apply.
Wood Destroying Organisms ( ) = Items or discoveries that indicate the presence of wood destroying organisms orconditions conducive to wood destroying organisms. Conducive conditions include but are not limited to, inadequateclearances, earth/wood contact, cellulose debris, inadequate ventilation, and excessive moisture.
Standard Limitations: Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes ofthe need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance ornon-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability;The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence of
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 3 of 54
pests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Homeinspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system orcomponent; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspectoror other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does notrespond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debristhat obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardoussubstance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine theeffectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limitedto failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information shouldhire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.
Standards of Practice:Washington State Standards of Practice forHome Inspectors & Inspections (WAC308-408C), Wood Destroying OrganismInspection Standards of the WashingtonState Pest Management Association
Type of building::Single Family (2-story)
Approximate Square Footage::2408
Approximate Year of OriginalConstruction::1995
Occupancy::The home was occupied
Attending the Inspection::Owner
Weather during the Inspection::Clear
Significant precipitation in last 3 days::No
Temperature during inspection::Below 60 (F) = 15.5 (C)
Ground/Soil surface condition:Dry
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 4 of 54
Significant IssuesSignificant Issues = Items or discoveries indicate that these systems or components may cost significant money tocorrect now or in the near future, or items that require immediate attention to prevent additional damage or eliminatesafety hazards.
4. Wall Exteriors
4.4 Composite Siding(1) Hard-board siding produced prior to 1996 of various manufacturers have seen problems with susceptibility towater absorption and subsequent related problems and damage. Several class action lawsuits have been settled. Itis extremely important to keep this type of siding sealed with caulk and paint to avoid problems. Once damaged,replacement is generally the best option. During the recent roofing job, the leading edge was cut back at theflashing throughout the exterior, leaving an exposed and un-painted edge.
Siding damage from moisture was found in many areas around the home. Areas of particular susceptibility areconcentrated in the trim and at transition areas where water is most likely to penetrate. The extent of damage to thesubstrate and framing, if any, are unknown. I have documented some areas here in the photos, however due to theextent of the damage found, expect damage to other areas not identified.
I would recommend further assessment and discussing options and costs to repair/replace the damaged siding andtrim by a licensed siding contractor. These conditions are further conducive to wood destroying organisms.
5. Structure
5.2 Insulation Under Floor SystemThe under-floor insulation has been removed and requires replacement to include insulation of exposed copperpiping.
6. Electrical
6.20 Carbon Monoxide DetectorsCarbon monoxide detectors were not installed. Carbon monoxide alarms must be located outside of each separatesleeping area, in the immediate vicinity of the bedroom and on each level of the residence. Install in accordance withmanufactures recommend guidance or hire a licensed contractor for proper installation.
Reference WAC 51-51-315: http://apps.leg.wa.gov/WAC/default.aspx?cite=51-51-0315
Please note this section is not all-inclusive, please read the complete report.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 5 of 54
Repair & Maintenance SummaryRepair & Maintenance Issues = Items or discoveries indicate that these systems or components do not function asintended and/or maintenance is required in the near term. Further investigation by a specialist and/or subsequentobservation may be required.
1. Roof
1.0 Roof Structure Exterior(1) Roof sheathing recently replaced as part of a re-roofing requires priming and painting in the soffits exposed tothe weather around the home and on both levels.(2) Some isolated water damage (rot) in the soffit framing and sheathing not replaced during the re-roofing wasfound. I would recommend replacing affected components. These conditions are further conducive to wooddestroying organisms.
1.3 Roof Drainage System(1) Gutter seams require resealing around the home. These conditions are conducive to wood destroyingorganisms.
(2) Several gutter downspouts are damaged and may restrict flow. I would recommend replacement of thesedownspouts.
2. Attic
2.5 Attic Thermal EnvelopeSome insulation in the attic has been damaged and requires replacement.
3. Exterior
3.6 Deck, Balcony, Bridge and Porch,(1)
1. Please note, the back deck is not accessible for inspection from below.2. Paint is peeling from the decking. I would recommend re-painting/staining during the summer dry season
to maximize the remaining life-span of the deck.(3) The front step railings have developed rot and require rebuilding. These conditions are further conducive towood destroying organisms.
4. Wall Exteriors
4.0 Door Exteriors(1) The french doors on the back of the home from the family room are showing signs of weathering and need to bepainted.(2)
1. The kitchen french door lower lock will not operate.2. The lower-threshold requires adjustment/replacement (daylight).3. The dead-bolt requires a latch-plate.
4.4 Composite Siding
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 6 of 54
(2) The master bed-room chimney chase requires cleaning, preservation, and possibly painting.
5. Structure
5.4 Crawl Space Rodent ActivityI noted mice in the traps in the crawlspace. I would recommend continued measures to remove the mice and furthersealing possible entry-points.
6. Electrical
6.14 Conventional Electrical Receptacles (interior)This receptacle in the garage requires a cover-plate for electrical safety.
6.18 Visible Branch WiringThis open-splice circuit in the garage lighting must be housed within a sealed electrical junction box. I wouldrecommend correction by a licensed electrician.
7. Garage
7.0 Vehicle DoorsA garage vehicle door failed to reverse when a reasonable amount of resistance was applied. I would recommendservice by a qualified garage door contractor.
9. Plumbing
9.1 Source of WaterThe surge tank may be empty and the well system require adjustment. I would recommend servicing by a wellspecialist.
9.4 Electric Water Heater1. Seismic straps are required to be installed.2. I would recommend replacing the flex-hoses with copper piping. Repairs by a licensed plumber.3. It appears a long-term leak has caused corrosion on the top of the tank. I would recommend further
inspection/repairs by a qualified contractor.4. The bonding wires between hot and cold and to the tank are not in-place. I would recommend correction
by a qualified contractor.
10. Heating
10.1 Heaters, ElectricElectric wall heaters are very dirty and require cleaning. Power must be secured at the electrical panel prior toremoving the protective grill. I would recommend servicing/cleaning by a qualified contractor.
10.3 Fireplace(2) I would recommend cleaning of the chimney piping for both fireplaces by a professional chimney sweep if notrecently accomplished.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 7 of 54
11. Bathrooms
11.8 VentilationI would recommend cleaning the exhaust fan grills located in the bathrooms for improved performance.
11.11 ShowerTravertine is a highly porous stone and requires routine sealing when used as a shower surround.
12. Kitchen and Built-in Appliances
12.8 CabinetsThe kitchen sink cabinet floor has been damaged from a prior leak. I would recommend replacement of the cabinetfloor and monitor for any further leak.
12.11 Range HoodThe range down-draft is weak. The motor is noisy and the filter dirty. I would recommend servicing by an appliancetechnician.
Please note this section is not all-inclusive, please read the complete report.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 8 of 54
Future Improvements
1. Roof
1.6 Other1. The back deck metal framed sun-roof is attached to the home in a non-standard manner (flashing is face
mounted over-top of the siding) and may cause siding damage over the long-term.2. Please further consult the manufacturer for installation requirements.
3. Exterior
3.7 Additional StructuresPlease note, the barn and additional outbuilding were not inspected.
6. Electrical
6.19 Smoke DetectorsSmoke detectors are recommended on each floor of the home, in each bedroom of the home, outside commonbedroom areas. Install in accordance with manufactures recommend guidance or hire a licensed contractor forproper installation.
Reference WAC 212-10-040: http://apps.leg.wa.gov/wac/default.aspx?cite=212-10-040
7. Garage
7.2 FloorsA loft storage floor and stairs have been installed. Construction is non-standard in that the floor ledger-board is notsupported by load-bearing beams and posts, rather face-nailed to the wall . Additionally, the stairs are steeper thanallowed and have no hand-rail. Please further consult a structural engineer to determine the load-bearing capabilityof the loft flooring system.
12. Kitchen and Built-in Appliances
12.9 Kitchen AppliancesPlease note, kitchen appliances are generally older models. Consider purchasing a home warranty that covers suchappliances.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 9 of 54
Complete Wood Destroying Organism Inspection ReportComplete Wood Destroying Organism Inspection Report: This report identifies the presence of wood destroyingorganisms or conditions conducive to wood destroying organisms. Conducive conditions include but are not limited to,inadequate clearances, earth/wood contact, cellulose debris, inadequate ventilation, and excessive moisture. PestInspection Standards in Washington State, WAC 16-228-2045 - requires that a diagram / drawing be prepared forwood destroying organism (WDO) Reports. If the photos and descriptions in this report are inadequate, a drawingis available upon request.
WSDA ICN # 10323AR001
_________________________________________________________________________________________________________
Summary of Findings:
Visible Evidence of Active Wood Destroying Insects: None Noted / Present
Visible Evidence of Inactive Wood Destroying Insects: None Noted / Present
Visible Evidence of Active Wood Decaying Fungi: None Noted / Present
Visible Evidence of Damage by Wood Destroying Organisms: None Noted / Present
Visible Evidence of Conditions Conducive to Wood Destroying Organisms: None Noted / Present
_________________________________________________________________________________________________________
Moisture Meter Testing: Where moisture meter testing is indicated in this report a GE Protimeter BLD5365 SurveymasterDual-Function Moisture Meter was used.
Standard Limitations: Complete WDO inspections will identify conditions present at a subject property at the time of an inspection. Inspectorsare not required to report on any WDO infestation or other condition that might be subject to seasonal constraints or environmental condition ifevidence of those constraints or conditions is not visible at the time of inspection. Please note that most WDO observations are related to highmoisture conditions that could be conducive to mold-like substances. NORTHWEST WASHINGTON HOME INSPECTIONS LLC is not a moldspecialist and recommends consulting with an industrial hygienist or other mold remediation expert if concerned about mold or indoor airquality.
1. Roof
1.0 Roof Structure Exterior(2) Some isolated water damage (rot) in the soffit framing and sheathing not replaced during the re-roofing wasfound. I would recommend replacing affected components. These conditions are further conducive to wooddestroying organisms.
1.3 Roof Drainage System(1) Gutter seams require resealing around the home. These conditions are conducive to wood destroyingorganisms.
3. Exterior
3.6 Deck, Balcony, Bridge and Porch,
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 10 of 54
(3) The front step railings have developed rot and require rebuilding. These conditions are further conducive towood destroying organisms.
4. Wall Exteriors
4.4 Composite Siding(1) Hard-board siding produced prior to 1996 of various manufacturers have seen problems with susceptibility towater absorption and subsequent related problems and damage. Several class action lawsuits have been settled. Itis extremely important to keep this type of siding sealed with caulk and paint to avoid problems. Once damaged,replacement is generally the best option. During the recent roofing job, the leading edge was cut back at theflashing throughout the exterior, leaving an exposed and un-painted edge.
Siding damage from moisture was found in many areas around the home. Areas of particular susceptibility areconcentrated in the trim and at transition areas where water is most likely to penetrate. The extent of damage to thesubstrate and framing, if any, are unknown. I have documented some areas here in the photos, however due to theextent of the damage found, expect damage to other areas not identified.
I would recommend further assessment and discussing options and costs to repair/replace the damaged siding andtrim by a licensed siding contractor. These conditions are further conducive to wood destroying organisms.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 11 of 54
1. RoofThe roof inspection portion of the General Home Inspection will not be as comprehensive as an inspection performed by a qualified roofing contractor.Because of variations in installation requirements of the huge number of different roof-covering materials installed over the years, the General HomeInspection does not include confirmation of proper installation. Home Inspectors are trained to identify common deficiencies and to recognizeconditions that require evaluation by a specialist. Inspection of the roof typically includes visual evaluation of the roof structure, roof-coveringmaterials, flashing, and roof penetrations like chimneys, mounting hardware for roof-mounted equipment, attic ventilation devices, ducts forevaporative coolers, and combustion and plumbing vents. The roof inspection does not include leak-testing and will not certify or warranty the roofagainst future leakage. Other limitations may apply and will be included in the comments as necessary.
Styles & Materials
Method of inspection:Walked the roof
The roof style was:Gable
Primary roof-covering type:3-tab Fiberglass Asphalt Shingle
Drainage system description:Gutters and downspouts installed
Chimney flue material:Metal
Underlayment/Interlayment::Not Visible
Sky Light(s):None
Items
1.0 Roof Structure ExteriorComments: Inspected
(1) Roof sheathing recently replaced as part of a re-roofing requires priming and painting in the soffitsexposed to the weather around the home and on both levels.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 12 of 54
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 13 of 54
1.1 UnderlaymentComments: Not Inspected
1.2 Roof FlashingComments: Inspected
1.3 Roof Drainage SystemComments: Inspected
(2) Some isolated water damage (rot) in the soffit framing and sheathing not replaced during the re-roofing was found. I would recommend replacing affected components. These conditions are furtherconducive to wood destroying organisms.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 14 of 54
1.4 Plumbing and Combustion VentsComments: Inspected
1.5 Asphalt Composition ShingleComments: Inspected
(1) Gutter seams require resealing around the home. These conditions are conducive to wooddestroying organisms.
(2) Several gutter downspouts are damaged and may restrict flow. I would recommend replacement ofthese downspouts.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 15 of 54
1.6 OtherComments: Limitation
The roof of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
1. The back deck metal framed sun-roof is attached to the home in a non-standard manner (flashing isface mounted over-top of the siding) and may cause siding damage over the long-term.
2. Please further consult the manufacturer for installation requirements.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 16 of 54
2. AtticInspection of the attic typically includes visual examination the following:roof structure (framing and sheathing); roof structure ventilation; thermalenvelope; electrical components (wiring, junction boxes, outlets, switches and lighting); plumbing components (supply and vent pipes, bathroom ventterminations) and HVAC components (drip pans, ducts, condensate and TPR discharge pipes).
Styles & Materials
Attic info:Scuttle hole
Attic inspected from:Inside the attic
Attic thermal insulation material:Fiberglass Batt
Approximate attic thermal insulationdepth:
R-19 or better
Roof Structure Ventilation:Attic ventilation appeared sufficient
Roof structure ventilation device type:Continuous ridge and soffit vents
Roof Framing Type:Conventional Framing- dimensional
lumber
Roof Sheathing Material:Oriented Strand Board (OSB)
Items
2.0 Attic AccessComments: Limitation
2.1 Roof Framing (from attic)Comments: Limitation
2.2 Roof SheathingComments: Limitation
2.3 Roof Structure VentilationComments: Limitation
2.4 Attic ElectricalComments: Not Inspected
2.5 Attic Thermal EnvelopeComments: Inspected
2.6 Venting Systems (Kitchens, Baths and Laundry)Comments: Limitation
Some insulation in the attic hasbeen damaged and requiresreplacement.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 17 of 54
The attic of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 18 of 54
3. ExteriorInspection of the home exterior typically includes: exterior wall covering materials; exterior trim; window and door exteriors; adequate surfacedrainage; driveway and walkways; window wells; exterior electrical and plumbing components; and retaining wall conditions that may affect the homestructure. The potential for dangers/damage associated with trees- such as falling branches or root damage to foundations- varies with tree speciesand age, and requires an arborist evaluation.
The General Home Inspection does not include inspection of landscape irrigation systems, fencing or swimming pools/spas.
Styles & Materials
Driveway Material:Asphalt
Walkway Materials:Concrete
Appurtenance:Deck with stepsCovered porch
Downspout Discharge:Below Grade
Lot Description:Flat
Clearance to Grade:Standard
Items
3.0 Exterior ViewsComments: Inspected
3.1 DrivewayComments: Inspected
3.2 WalkwaysComments: Inspected
3.3 General GroundsComments: Inspected
3.4 Exterior TrimComments: Inspected
3.5 PorchComments: Inspected
3.6 Deck, Balcony, Bridge and Porch,Comments: Limitation
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 19 of 54
(1)1. Please note, the back deck is not accessible for inspection from below.2. Paint is peeling from the decking. I would recommend re-painting/staining during the summer dry
season to maximize the remaining life-span of the deck.
non-standard flashing
(2) The front steps would benefit from staining/preservation.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 20 of 54
3.7 Additional StructuresComments: Not Inspected
The exterior of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
(3) The front step railings have developed rot and require rebuilding. These conditions are furtherconducive to wood destroying organisms.
Please note, the barn and additional outbuilding were not inspected.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 21 of 54
4. Wall ExteriorsInspection of the home exterior typically includes: exterior wall covering materials; exterior trim; window and door exteriors; adequate surfacedrainage; driveway and walkways; window wells; exterior electrical and plumbing components; and retaining wall conditions that may affect the homestructure. The potential for dangers/damage associated with trees- such as falling branches or root damage to foundations- varies with tree speciesand age, and requires an arborist evaluation.
The General Home Inspection does not include inspection of landscape irrigation systems, fencing or swimming pools/spas.
Styles & Materials
Exterior wall-covering Material:Hardboard Lap Siding
Exterior Doors:Metal
Items
4.0 Door ExteriorsComments: Inspected
(1) The french doors on the backof the home from the family room areshowing signs of weathering and needto be painted.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 22 of 54
(2)1. The kitchen french door lower lock will not operate.2. The lower-threshold requires adjustment/replacement (daylight).3. The dead-bolt requires a latch-plate.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 23 of 54
4.1 Window ExteriorsComments: Inspected
4.2 Exterior Wall PenetrationsComments: Inspected
4.3 Exterior Wall MembraneComments: Inspected
4.4 Composite SidingComments: Inspected
(1) Hard-board siding produced prior to 1996 of various manufacturers have seen problems withsusceptibility to water absorption and subsequent related problems and damage. Several class action lawsuitshave been settled. It is extremely important to keep this type of siding sealed with caulk and paint to avoidproblems. Once damaged, replacement is generally the best option. During the recent roofing job, the leadingedge was cut back at the flashing throughout the exterior, leaving an exposed and un-painted edge.
Siding damage from moisture was found in many areas around the home. Areas of particular susceptibility areconcentrated in the trim and at transition areas where water is most likely to penetrate. The extent of damageto the substrate and framing, if any, are unknown. I have documented some areas here in the photos,however due to the extent of the damage found, expect damage to other areas not identified.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 24 of 54
I would recommend further assessment and discussing options and costs to repair/replace the damaged sidingand trim by a licensed siding contractor. These conditions are further conducive to wood destroyingorganisms.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 25 of 54
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 26 of 54
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 27 of 54
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 28 of 54
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 29 of 54
The exterior of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
(2) The master bed-roomchimney chase requires cleaning,preservation, and possibly painting.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 30 of 54
5. StructureThe General Home Inspection includes inspection of the home structural elements that were readily visible at the time of the inspection. This mayinclude the: foundation; walls; floor structure; and/or roof structure. Soils vary in their stability and ability to support the weight of a structure. Minorcracking is normal with some common foundation materials, is typically limited to the material surface, is not a structural concern, and may not becommented on. Cracking related to soil/foundation movement indicates the potential for present or future structural concerns and will be commentedon to the best of the inspector's ability.
Much of the home structure is hidden behind exterior and interior roof, floor, wall, and ceiling coverings, or is buried underground. Because theGeneral Home Inspection is limited to visual and non-invasive methods, this report may not identify all structural deficiencies. Identification of portionsof the wall structure not directly visible requires logical assumptions on the part of the Inspector that are based on the Inspectors past experience andknowledge of common building practices.
Upon observing indications that structural problems may exist that are not readily visible, or the evaluation of which lies beyond the Inspector'sexpertise, the inspector may recommend evaluation or testing by a specialist that may include invasive measures, which would require homeownerpermission.
Styles & Materials
Typical Ceiling Structure:Not visible
Exterior Wall Structures:Conventional 2x6 Wood Frame
Wall Insulation:Not Visible
Foundation Configuration:Crawlspace
Foundation Method/Materials:Poured concrete foundation walls
Main Floor Structure:Oriented strand board (OSB) sheathing
over wood joists
Main Floor Structure- Perimeter Bearing:Rests on top of foundation wall
Main Floor Structure- IntermediateSupport:
Wood beam girderWood postsConcrete Piers
Floor System Insulation:BattsFiberglass
Evidence of Seismic Protection:None Noted
Crawl Space Vapor Barrier:6 Mil Poly
Items
5.0 Exterior Wall ConstructionComments: Inspected
5.1 Floor StructureComments: Inspected
5.2 Insulation Under Floor SystemComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 31 of 54
5.3 FoundationComments: Inspected
5.4 Crawl Space Rodent ActivityComments: Inspected
The structure of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
The under-floor insulation has been removed and requires replacement to include insulation of exposedcopper piping.
I noted mice in the traps in thecrawlspace. I would recommendcontinued measures to remove themice and further sealing possibleentry-points.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 32 of 54
6. ElectricalOver the years, many different types and brands of electrical components have been installed in homes. Electrical components and standards havechanged and continue to change. Homes electrical systems are not required to be updated to meet newly enacted electrical codes or standards. Fulland accurate inspection of electrical systems requires contractor-level experience. For this reason, full inspection of home electrical systems liesbeyond the scope of the General Home Inspection.
The General Home Inspection is limited to identifying common electrical requirements and deficiencies. Conditions indicating the need for a morecomprehensive inspection will be referred to a qualified electrical contractor.Inspection of the home electrical system typically includes visualinspection of the following:service drop: conductors, weatherhead, and service mast; electric meter exterior; service panel and sub-panels; serviceand equipment grounding; system and component bonding; and visible branch wiring: receptacles (representative number), switches, lighting
Styles & Materials
Electrical Service Conductors:Underground serviceAluminum120/240 volt service
Service Panel Ampacity:200 amps
Service Panel Type:Load Center
Service Panel Manufacturer:Cuttler Hammer
Service Disconnect Location:At Service Panel
Service Disconnect Type:Breaker
Service Grounding Electrode:Not Visible
Wiring Methods:Romex
Type of Branch Wiring:Solid CopperStranded Copper
Ground Fault Circuit Interruptor (GFCI)Protection:
Partial
Arc Fault Circuit Interruptor (AFCI)Protection:
NO
Items
6.0 General Electrical System DescriptionComments: Inspected
6.1 General Electrical System ConditionComments: Inspected
6.2 Service Drop, Drip Loop, Splice and AttachmentComments: Inspected
6.3 Electric MeterComments: Inspected
6.4 Service Entrance ConductorsComments: Inspected
6.5 Service Panel ManufacturerComments: Inspected
6.6 Service Panel Exposure RatingComments: Inspected
6.7 Service Panel Cabinet, Ampacity, and CoverComments: Inspected
6.8 Service Panel WiringComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 33 of 54
6.9 Service DisconnectComments: Inspected
6.10 Overcurrent Protection DevicesComments: Inspected
6.11 Service Grounding Electrode System & Service BondComments: Inspected
6.12 Equipment Grounding & BondingComments: Inspected
6.13 Exterior Electrical ReceptaclesComments: Inspected
6.14 Conventional Electrical Receptacles (interior)Comments: Inspected
6.15 GFCI/AFCI Electrical ReceptaclesComments: Inspected
6.16 SwitchesComments: Inspected
6.17 LightingComments: Inspected
6.18 Visible Branch WiringComments: Inspected
This receptacle in the garagerequires a cover-plate for electricalsafety.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 34 of 54
6.19 Smoke DetectorsComments: Inspected
6.20 Carbon Monoxide DetectorsComments: Inspected
This open-splice circuit in thegarage lighting must be housed withina sealed electrical junction box. Iwould recommend correction by alicensed electrician.
Smoke detectors are recommended on each floor of the home, in each bedroom of the home, outsidecommon bedroom areas. Install in accordance with manufactures recommend guidance or hire a licensedcontractor for proper installation.
Reference WAC 212-10-040: http://apps.leg.wa.gov/wac/default.aspx?cite=212-10-040
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 35 of 54
6.21 DoorbellComments: Inspected
The electrical system of the home was inspected and reported on with the above information. Outlets were not removed and the inspection was onlyvisual. Any outlet not accessible (behind the refrigerator for example) was not inspected or accessible. Any repair items mentioned in this reportshould be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates tothe comments in this inspection report.
Carbon monoxide detectors were not installed. Carbon monoxide alarms must be located outside ofeach separate sleeping area, in the immediate vicinity of the bedroom and on each level of the residence.Install in accordance with manufactures recommend guidance or hire a licensed contractor for properinstallation.
Reference WAC 51-51-315: http://apps.leg.wa.gov/WAC/default.aspx?cite=51-51-0315
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 36 of 54
7. GarageInspection of the garage typically includes examination of the following:general structure; floor, wall and ceiling surfaces; operation of all accessibleconventional doors and door hardware; vehicle door condition and operation proper electrical condition including Ground Fault Circuit Interrupter(GFCI) protection; interior and exterior lighting; stairs and stairways proper firewall separation from living space; and proper floor drainage
Styles & Materials
Garage Vehicle Door Type:Double
Number of Vehicle Doors:1
Number of Automatic Openers:1
Vehicle Door Automatic Reverse:Failure to reverse
Auto-opener Manufacturer:AUTOMATIC DOORMAN
Items
7.0 Vehicle DoorsComments: Inspected
7.1 Conventional DoorsComments: Inspected
7.2 FloorsComments: Inspected
A garage vehicle door failed toreverse when a reasonable amount ofresistance was applied. I wouldrecommend service by a qualifiedgarage door contractor.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 37 of 54
7.3 WallsComments: Inspected
7.4 CeilingComments: Inspected
7.5 Fire SeparationComments: Inspected
A loft storage floor and stairs have been installed. Construction is non-standard in that the floor ledger-board is not supported by load-bearing beams and posts, rather face-nailed to the wall . Additionally, the stairsare steeper than allowed and have no hand-rail. Please further consult a structural engineer to determine theload-bearing capability of the loft flooring system.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 38 of 54
7.6 Stairs/Steps to Living SpaceComments: Inspected
7.7 Garage ElectricalComments: Inspected
7.8 General Condition and VentilationComments: Inspected
7.9 AtticComments: Inspected
The structure of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 39 of 54
8. InteriorInspection of the home interior does not include testing for mold, radon, asbestos, lead paint, or other environmental hazards unless specificallyrequested as an ancillary inspection. Inspection of the home interior typically includes: interior wall, floor and ceiling coverings and surfaces; doorsand windows: condition, hardware, and operation; interior trim: baseboard, casing, molding, etc.; permanently-installed furniture, countertops,shelving, and cabinets; and ceiling and whole-house fans.
Styles & Materials
Walls and Ceilings:Drywall
Floor Covering Materials:CarpetTileSheet Vinyl
Interior Doors:Wood Hollow Core
Window Material:Vinyl
Window Glazing:Double-pane
Window Operation:Single-hung
Smoke/CO Detectors:Smoke detectors installedCarbon Monoxide detectors were not
installed
Items
8.0 FloorsComments: Inspected
8.1 WallsComments: Inspected
8.2 CeilingsComments: Inspected
8.3 LightingComments: Inspected
8.4 DoorsComments: Inspected
8.5 Windows and SkylightsComments: Inspected
8.6 Interior TrimComments: Inspected
8.7 Cabinets and CountertopsComments: Inspected
8.8 StairsComments: Inspected
8.9 Bathroom and Laundry VentilationComments: Inspected
The interior of the home was inspected and reported on with the above information. The inspection did not involve moving furniture and inspectingbehind furniture, area rugs or areas obstructed from view. Any repair items mentioned in this report should be considered before purchase. It isrecommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 40 of 54
9. PlumbingInspection of the plumbing system typically includes (limited) operation and visual inspection of: water supply source (identification as public orprivate); sewage disposal system (identification as public or private); water supply/distribution pipes; drain, waste and vent (DWV) system; waterheater (type, condition and operation); gas system; and sump pump (confirmation of installation/operation).
Styles & Materials
Water Supply Source:Community Well
Main Water Supply Pipe:1-inchCopper
Main Water Supply Location:Garage
Water Distribution Pipes:3/4-inch copper
Distribution Pipe Bonding:Pipes were not bonded
Sewage System Type:Septic system
Drain Waste and Vent Pipe Materials:Acrylonitrile butadiene styrene (ABS)
Water Heater Manufacturer:Whirlpool
Date of Manufacture:2008
Water Heater Fuel Type:Electric
Water Heater Type:Tank (conventional)
Water Heater Tank Capacity:50 gallons
Water Heater Location:Utility Room
Washer Drain Size:2" Diameter
Items
9.0 Exterior PlumbingComments: Inspected
9.1 Source of WaterComments: Inspected
The surge tank may be emptyand the well system requireadjustment. I would recommendservicing by a well specialist.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 41 of 54
9.2 Water Supply and DistributionComments: Inspected
9.3 Sewage and DWV SystemsComments: Inspected
9.4 Electric Water HeaterComments: Inspected
1. Seismic straps are required to be installed.2. I would recommend replacing the flex-hoses with copper piping. Repairs by a licensed plumber.3. It appears a long-term leak has caused corrosion on the top of the tank. I would recommend further
inspection/repairs by a qualified contractor.4. The bonding wires between hot and cold and to the tank are not in-place. I would recommend
correction by a qualified contractor.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 42 of 54
The plumbing in the home was inspected and reported on with the above information. Washing machine drain line for example cannot be checked forleaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed andbarely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waitingfor closing) rust or deposits within the pipes can further clog the piping system. Any repair items mentioned in this report should be considered beforepurchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
The plumbing in the home was inspected and reported on with the above information. Washing machine drain line for example cannot be checked forleaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed andbarely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waitingfor closing) rust or deposits within the pipes can further clog the piping system. Any repair items mentioned in this report should be considered beforepurchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 43 of 54
10. HeatingHeating system inspection will not be as comprehensive as that performed by a qualified heating, ventilating, and air-conditioning (HVAC) systemcontractor. For example: identification of cracked heat exchangers requires a contractor evaluation. Report comments are limited to identification ofcommon requirements and deficiencies. Observed indications that further evaluation is needed will result in referral to a qualified HVAC contractor.The general home inspection does not include any type of heating system warranty or guaranty. Inspection of heating systems is limited to basicevaluation based on visual examination and operation using normal controls. Report comments are limited to identification of common requirementsand deficiencies. Observed indications that further evaluation is needed will be referred to a qualified heating, ventilating, and air-conditioning (HVAC)contractor. Inspection of heating systems typically includes (limited) operation and visual inspection of: the heating appliance (confirmation ofadequate response to the call for heat); proper heating appliance location; proper or adequate heating system configuration; exterior cabinetcondition; fuel supply configuration and condition; combustion exhaust venting; heat distribution components; proper condensation discharge; andtemperature/pressure relief valve and discharge pipe (presence, condition, and configuration).
Styles & Materials
Heating System Type:Electric Wall Heaters
Energy Source:Electric
Number of Heat Systems (excludingwood):
One
Heating/Cooling Ducts:N/A
Heating System Brand:Cadet
Types of FIreplaces:Pellet burning
Number of Woodstoves:One
Items
10.0 Presence of installed heat source in each roomComments: Inspected
10.1 Heaters, ElectricComments: Inspected
Electric wall heaters are verydirty and require cleaning. Powermust be secured at the electrical panelprior to removing the protective grill. Iwould recommend servicing/cleaningby a qualified contractor.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 44 of 54
10.2 ThermostatComments: Inspected
10.3 FireplaceComments: Inspected
(1) I found stains from a pastfireplace chimney and/or flashing leakin the living room chimney. The roofwas recently replaced, monitor for anyfuture leaks.
(2) I would recommend cleaning of the chimney piping for both fireplaces by a professional chimneysweep if not recently accomplished.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 45 of 54
The heating system of this home was inspected and reported on with the above information. The inspection is not meant to be technically exhaustive.The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensedheat contractor would discover. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualifiedcontractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 46 of 54
11. BathroomsInspection of the bathrooms typically includes the following:walls, floors and ceiling; sink (basin, faucet, overflow); cabinets (exteriors, doors, drawers,undersink); toilet/bidet tub and shower (valves, showerhead, walls, enclosure); electrical (outlets, lighting); and room ventilation
Styles & Materials
Exhaust Fans:Fan only
Items
11.0 FloorsComments: Inspected
11.1 WallsComments: Inspected
11.2 CeilingsComments: Inspected
11.3 DoorsComments: Inspected
11.4 WindowsComments: Inspected
11.5 SkylightsComments: Inspected
11.6 Electrical Receptacles and SwitchesComments: Inspected
11.7 LightingComments: Inspected
11.8 VentilationComments: Inspected
I would recommend cleaning the exhaust fan grills located in the bathrooms for improved performance.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 47 of 54
11.9 CabinetsComments: Inspected
11.10 ToiletComments: Inspected
11.11 ShowerComments: Inspected
11.12 Medicine CabinetComments: Inspected
11.13 MirrorsComments: Inspected
11.14 SinkComments: Inspected
The bathrooms of the home was inspected and reported on with the above information. Any repair items mentioned in this report should beconsidered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to thecomments in this inspection report.
Travertine is a highly porous stone and requires routine sealing when used as a shower surround.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 48 of 54
12. Kitchen and Built-in AppliancesInspection of kitchens typically includes (limited) operation and visual inspection of the following: wall, ceiling and floor; windows, skylights and doors;range/cooktop (basic functions, anti-tip); range hood (fan, lights, type); dishwasher; Cabinetry exterior and interior; door and drawer; Sink basincondition; supply valves; adequate trap configuration; functional water flow and drainage; disposal; Electrical switch operation; and outlet placement,grounding, and GFCI protection. Note: Appliances are operated at the discretion of the Inspector.
Styles & Materials
Cabinets:Solid Wood
Countertop Material:Granite
Range:Gas
Range/Oven Brand:Jenn Air
Range Hood:Vents to exterior
Range Hood Brand:Jenn Air
Dishwasher:Present, not inspected
Dishwasher brand:Kenmore
Dishwasher Anti-siphon method:High-loop installed
Garbage Disposal brand:Badger
Trash Compactor Brand:Kenmore
Built-in Microwave Brand:General Electric
Refrigerator:Present, not inspected
Refridgerator Brand:General Electric
Items
12.0 FloorsComments: Inspected
12.1 WallsComments: Inspected
12.2 CeilingsComments: Inspected
12.3 DoorsComments: Inspected
12.4 WindowsComments: Inspected
12.5 Interior TrimComments: Inspected
12.6 Receptacles and SwitchesComments: Inspected
12.7 LightingComments: Inspected
12.8 CabinetsComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 49 of 54
12.9 Kitchen AppliancesComments: Inspected
The kitchen sink cabinet floor hasbeen damaged from a prior leak. Iwould recommend replacement of thecabinet floor and monitor for anyfurther leak.
Please note, kitchen appliances are generally older models. Consider purchasing a home warranty thatcovers such appliances.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 50 of 54
12.10 RangeComments: Inspected
12.11 Range HoodComments: Inspected
The range down-draft is weak.The motor is noisy and the filter dirty. Iwould recommend servicing by anappliance technician.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 51 of 54
12.12 DishwasherComments: Inspected
12.13 CounterComments: Inspected
12.14 SinkComments: Inspected
The Kitchen and built-in appliances of the home were inspected and reported on with the above information. Any repair items mentioned in this reportshould be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates tothe comments in this inspection report.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 52 of 54
13. Laundry RoomIn addition to those items typically inspected as part of the interior, inspection of the laundry room includes examination of the following:dryerconnections and venting; room ventilation; and provision of proper clothes washer waste pipe.
Styles & Materials
Dryer Power:Electric
Dryer Vent:Smooth-bore metal
Dryer 240-volt electrical receptacle:Installed
Items
13.0 FloorsComments: Inspected
13.1 WallsComments: Inspected
13.2 CeilingsComments: Inspected
13.3 DoorsComments: Inspected
13.4 WindowsComments: Inspected
13.5 SkylightsComments: Inspected
13.6 Receptacles, Switches, ConnectionsComments: Inspected
13.7 LightingComments: Inspected
13.8 CabinetsComments: Inspected
13.9 Dryer VentingComments: Inspected
13.10 Washer/DryerComments: Not Inspected
The laundry room of the home was inspected and reported on with the above information. Any repair items mentioned in this report should beconsidered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to thecomments in this inspection report.
NW WASHINGTON HOME INSPECTIONS LLC Majeske
2775 SW Bag End Way Page 53 of 54