EE 4BD4 Lecture 21
Cardiac Pacing
1
![Page 2: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/2.jpg)
Electrical Pathways of the Heart
2
![Page 3: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/3.jpg)
3
![Page 4: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/4.jpg)
Type I Heart Block
4
![Page 5: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/5.jpg)
5
![Page 6: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/6.jpg)
Type 2 Heart Block
6
![Page 7: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/7.jpg)
7
![Page 8: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/8.jpg)
Type 3 Heart Block
8
![Page 9: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/9.jpg)
History• 1774 Aldini electrically resuscitated a 3 year old child• Over next 2 centuries scientists experimented with
electrical cardiac stimulation cardiac• First electrostatic charges and later a-c and d-c currents• 1932 Alfred Hyman developed the first device to
stimulate the heart electronically. Delivered 3 mA pulses directly to heart using needle electrodes
• Coined the term pacemaker• 1947 Beck reported a successful cardiac defibrillation• 1952 Paul Zoll reported a closed-chest external
electrical cardiac pacemaker using surface electrodes, 2 ms pulses, 100-200 mA
• Caused pain and burns
9
![Page 10: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/10.jpg)
History (cont’d)
10
![Page 11: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/11.jpg)
History (cont’d)
11
![Page 12: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/12.jpg)
History (cont’d)
• 1960 Chardack and Greatbach implanted a pacemaker
• Examples:
12
![Page 13: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/13.jpg)
First Type of Pacemaker Developedcomplete heart block only
13
![Page 14: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/14.jpg)
Pacemaker Specifications
• Power supply: lithium type (iodide) long life 5 -10 years (early batteries 2 years max)
• Oscillator: (fixed rate) set at 70 – 90 beats/min• Output circuit: Constant voltage 5.0 to 5.5, 500 – 600
µs duration; constant current 8 – 10 mA, 1.0 – 1.2 ms• Lead wires: inter-wound helical coils spring-wire alloy
(fatigue resistant) in silicone rubber or polyurethane cylinder
• Electrodes: unipolar or bipolar (unipolar return electrode on case) platinum alloys such as platinum iridium (biocompatible and inert)
14
![Page 15: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/15.jpg)
Demand Inhibit (synchronous)incomplete heart block
• Most current single lead types (avoids stimulating during naturally occurring T-wave to avoid sending heart into fibrillation)
• Saves energy since pulse sent out only when needed• Stimulating electrode senses QRS and resets timer• Rest of circuit same as asynchronous
15
![Page 16: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/16.jpg)
Atrial Synchronous• Assumes SA node functional• 120 ms delay allows ventricles to fill during atrial
contraction• 500 ms delay locks out circuit to avoid QRS
pulse from triggering another stimulus
16
![Page 17: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/17.jpg)
Activity or Demand Responsive Pacemakers
17
![Page 18: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/18.jpg)
Temporary External Pacemakres
18
![Page 19: EE 4BD4 Lecture 21 Cardiac Pacing.](https://reader035.fdocuments.in/reader035/viewer/2022062317/5a4d1b4b7f8b9ab0599a5617/html5/thumbnails/19.jpg)
Lead Placements
19