DOOR FRAME & DESIGN - Canadian Curtis Refrigeration · Door and door frame constructed of 24 gauge...
Transcript of DOOR FRAME & DESIGN - Canadian Curtis Refrigeration · Door and door frame constructed of 24 gauge...
CONSTRUCTION:
Door and door frame constructed of 24 gauge pre-painted galvanized steel; polyurethane foamed-in-place insulation.
MAGNETIC GASKET
Specially designed vinyl covered magnetic gasketwith welded corners for positive air-tight seal.Locks into built-in retainer. Fast easy replacementwithout tools.
DOOR CLOSER
Positive spring activated mechanismbrings door to a smooth close.
RELIEF PORT
Heated air pressure relief portequipped on all rooms below 2°C / 34°F.Equalizes pressure when door isopened or closed. Heated valve pre-vents freeze-up.
HINGES
Heavy duty construction self closingcam action nylon bushings for long life.
SILL PLATE
14 GA. stainless steel plate reinforcedto withstand heavy traffic.
DOOR FRAME HEATER
Low wattage heater cable preventsfrost build-up. Surface mounted inperimeter raceways with chrome plat-ed snap-on cover trim. Standard on allrooms below 0 °C / 32 °F.
HANDLE / LATCH
Heavy duty construction lever actionpadlockable. Equipped with quick act-ing inside safety release to preventaccidental entrapment.
THERMOMETER
Flush mounted Electronic Digital thermometerfor accurate reading of interior temperaturerange from -40 °C to 20 °C.
LIGHTINGFactory Installed
Pilot light and switch mounted in stainless steelcover plate. Inter-wired to interior vapour prooflight fixture, switch mounted with thermometer.
Door image is a graphical representationof Curtis door and door frame
DOOR FRAME & DESIGN SPECIF ICATIONS
Canadian Curt is Ref r igerat ion Inc.3200 Highway 7, Vaughan, Ontario L4K 5Z5
Tel: 905-660-01101-866-328-7847
Fax: 905-660-0310www.canadiancurtis.com
*Specifications subject to change by Curtis without prior notice
GENERAL CONTRACTORThe expansion joint must be installed as to form an integral part with the slab insu-lation creating a continuous thermal barrier. The expansion joint must be installedin such a manner that it will not be lifted or torn during floor construction.
NOTE TO CONTRACTOR: NO BUTT JOINTS
Curtis walk-in coolers (above 2°C) normally do NOT require floorinsulation when slab-on-grade. Freezers (below 2°C) ALWAYSrequire floor insulation & interior/exterior thermal break.
18 GAUGE
FINISHED BUILDING FLOOR
3” INSULATED WALL PANEL
3” INSULATED GALVANIZEDCURTIS FLOOR
FINISHEDBUILDING
FLOOR
PERIMETERGROUTING BYGENERAL CONTRACTOR ½” SAND LEVELING COURSE
(BY GENERAL CONTRACTOR)
½”3 ½” DEPRESSION
BY G.C.
DEPRESSIONBY G.C.
3” INSULATED WALL PANEL
3” INSULATED GALVANIZED CURTISFLOOR AND SCREED
FINAL FLOOR FINISH AND GROUTING(BY GENERAL CONTRACTOR)
FINISHEDBUILDING
FLOOR
FINISHEDBUILDING
FLOOR
FINISHEDBUILDING
FLOOR
PERIMETERGROUTING BYGENERAL CONTRACTOR ½” SAND LEVELING COURSE
(BY GENERAL CONTRACTOR)
6 - ½”
½”
DEPRESSIONBY G.C.
CURTIS INSULATED WALL PANEL
1 ½” WIDE HIGH DENSITY RIGID POLY-STYRENE EXPANSION JOINT (BY GENERALCONTRACTOR). MUST PROTRUDE 1”ABOVE FINISHED BUILDING FLOOR.
4” SLAB INSULATION. (R 20 MINIMUM)(BY GENERAL CONTRACTOR)
4”7”
3”
¾” WATERPROOF PLYWOODBONDED INTO 3” INSULATEDCURTIS FLOOR
RESIN ADHESIVE
ALTRO SAFETY FLOORINGSPECIFY COLOUR
CURTIS WALL PANEL
EXTERIOR
INTERIOR
EXTERIOR
INTERIOR
EXTERIOR
INTERIOR
WALK-IN NO FLOOR ( STANDARD )SCALE: N.T.S.
WALK-IN 3” GALV. CLAD FLOOR ( STANDARD )SCALE: N.T.S.
WALK-IN FLOOR DETAILS
EXPANSION JOINT DETAILSCALE: N.T.S.
3-½” FLOOR DEPRESSION DETAIL SCALE: N.T.S.
6-½” FLOOR DEPRESSION DETAIL SCALE: N.T.S.
ALTRO SAFETY FLOORING DETAILSCALE: N.T.S.
EXTERIOR
INTERIOR