D 96-4049 002powder coating GFI circuit breakers available through 50A One-piece case back for...

3
Volume 1—Residential and Light Commercial CA08100002E—December 2010 www.eaton.com 289 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6.2 Power Pedestals Temporary Power/RV Park Two Styles to Meet Your Power Outlet Needs Surface mount: User mounts unit to a post Pedestal mount: User mounts with an underground pedestal extension or pad-mounting bracket. (Underground pedestal extension and pad-mounting bracket are sold separately. See accessories Page 291 for part numbers and options) Compact Design Available in Certain Configurations for Added Convenience Standards and Certifications UL Standard 231 UL File Number E163588 Receptacles conform to NEMA and/or ANSI configurations as specified by the NEC. Standard Compliance All power outlet panels for temporary construction site power and RV (recreational vehicle) application shall be UL listed for the U.S. per UL Standard 231, File E163588. Receptacles shall conform to NEMA and/or ANSI configurations as specified by the National Electrical Code (NEC). Surface Units Pedestal Units Lighted option for site location and nighttime panel operations Three-point mounting 100 percent galvanized steel with baked-on polyester powder coating GFI circuit breakers available through 50A One-piece case back for metered and unmetered panels Unique steel barrier prevents unauthorized operation of breakers when door is closed and padlocked Lower deadfront cover can be removed for easy routing of incoming wires or receptacle changeouts Padlock provisions to prevent unauthorized entry Utility grade metering available for construction site or RV park applications Removable upper deadfront cover for easy incoming wire connections to breaker terminals • Units are factory wired and assembled NEMA 3R construction for rainproof installation Door swings up when opening and allows cords to remain connected when closed. • Metered units available with meter on top or on bottom • Units are factory wired and assembled 100 percent galvanized steel with baked-on polyester powder coating GFI circuit breakers (single- and two-pole) available through 50A One-piece case back for metered and unmetered panels Removable upper deadfront cover for easy incoming wire connections to breaker terminals Door swings up when opening and allows cords to remain connected when closed Unique steel barrier prevents unauthorized operation of breakers when door is closed and padlocked Lower deadfront cover can be removed for easy routing of incoming wires or receptacle changeouts Padlock provisions to prevent unauthorized entry Loop-feed lug assembly with 350 kcmil lugs included as standard Pad-mounted bracket option also available Pedestal extension available for underground services Utility grade metering available for construction site or RV park applications NEMA 3R construction for rainproof installation

Transcript of D 96-4049 002powder coating GFI circuit breakers available through 50A One-piece case back for...

Page 1: D 96-4049 002powder coating GFI circuit breakers available through 50A One-piece case back for connected metered and unmetered panels Unique steel barrier prevents unauthorized operation

Volume 1—Residential and Light Commercial

CA08100002E—December 2010 www.eaton.com

289

666666666666666666666666666666

6.2

Power Pedestals

Temporary Power/RV Park

Two Styles to Meet Your Power Outlet Needs● Surface mount: User

mounts unit to a post● Pedestal mount:

User mounts with an underground pedestal extension or pad-mounting bracket. (Underground pedestal extension and pad-mounting bracket are sold separately. See accessories Page 291 for part numbers and options)

Compact Design Available in Certain Configurations for Added Convenience

Standards and Certifications● UL Standard 231● UL File Number E163588Receptacles conform to NEMA and/or ANSI configurations as specified by the NEC.

Standard ComplianceAll power outlet panels for temporary construction site power and RV (recreational vehicle) application shall be UL listed for the U.S. per UL Standard 231, File E163588. Receptacles shall conform to NEMA and/or ANSI configurations as specified by the National Electrical Code (NEC).

Surface Units

Pedestal Units

Lighted option for site location and nighttime panel operations

Three-point mounting

100 percent galvanized steel with baked-on polyester powder coating

GFI circuit breakers available through 50A

One-piece case back for metered and unmetered panels

Unique steel barrier prevents unauthorized operation of breakers when door is closed and padlocked

Lower deadfront cover can be removed for easy routing of incoming wires or receptacle changeouts

Padlock provisions to prevent unauthorized entry

Utility grade metering available for construction site or RV park applications

Removable upper deadfront cover for easy incoming wire connections to breaker terminals

• Units are factory wired and assembled

NEMA 3R construction for rainproof installation

Door swings up when opening and allows cords to remain connected when closed.

• Metered units available with meter on top or on bottom

• Units are factory wired and assembled

100 percent galvanized steel with baked-on polyester powder coating

GFI circuit breakers (single- and two-pole) available through 50A

One-piece case back for metered and unmetered panels

Removable upper deadfront cover for easy incoming wire connections to breaker terminals

Door swings up when opening and allows cords to remain connected when closed

Unique steel barrier prevents unauthorized operation of breakers when door is closed and padlocked

Lower deadfront cover can be removed for easy routing of incoming wires or receptacle changeouts

Padlock provisions to prevent unauthorized entry

Loop-feed lug assembly with 350 kcmil lugs included as standard

Pad-mounted bracket option also available

Pedestal extension available for underground services

Utility grade metering available for construction site or RV park applications

NEMA 3R construction forrainproof installation

Page 2: D 96-4049 002powder coating GFI circuit breakers available through 50A One-piece case back for connected metered and unmetered panels Unique steel barrier prevents unauthorized operation

78 6 5 4 3 2 1

78 6 5 4 3 2 1

D

C

B

A

D

C

B

A

DSD_DFM_ACAD_WEB.DWG

TITLE / DESCRIPTION

SHEET

DRAFTER/DESIGNER DATE (YYYY/MM/DD)

DRAWINGNUMBER

REVISIONSIZE

UNLESS OTHERWISE SPECIFIEDDIMENSIONS IN

SCALEOF

D

C Eaton Corporation, All Rights Reserved

THE INFORMATION ON THIS DRAWING ISDISCLOSED IN CONFIDENCE AND IS NOT

TO BE REPRODUCED, USED ORDISCLOSED, EXCEPT FOR THE PURPOSE

WHICH FURNISHED.

POWER OUTLET, UNMETERED PEDESTAL EXTENSION

M. CASTRO

2013/12/18

96-4049002

INCHES

N/A1

1

2000

Page: 1 of 1

Page 3: D 96-4049 002powder coating GFI circuit breakers available through 50A One-piece case back for connected metered and unmetered panels Unique steel barrier prevents unauthorized operation