CURRENT MEASUREMENTCURRENT MEASUREMENT
Current clamps Selection Guide
For intensitiesClamping diameter (mm) 10 20 30 52 64 100 380 3.9 8 30 39
AC ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
DC ■ ■ ■ ■
Min 5 mA 10 mA 1 A 1 mA 100 mA 500 µA 500 mA 100 µA 5 mA 200 mA 200 mAMAX 150 A 240 A 600 A 1,200 A 3,600 A 400 A 10,000 A 4.5 A 150 A 600 A 1,000 A
Outputin mA AC ■ ■ ■ ■ ■
in mV AC ■ ■ ■ ■ ■ ■ ■
in mV DC ■ ■ ■
in mV AC+DC ■ ■ ■ ■
Connection Insulated Ø 4 mm sockets ■ ■ ■
Lead with insulated elbowed ■ ■ ■ ■ ■ ■ ■ ■ ■
with Ø 4 mm plugsInsulated Ø 4 mm plug box ■ ■
with standard 19 mm spacingCoaxial cable with ■ ■ ■ ■ ■ ■ ■
insulated male BNC
Single-calibre ■ ■ ■ ■ ■
Multi-calibre ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
For multimeter ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
For oscilloscope ■ ■ ■ ■ ■ ■ ■ ■
For seeking leaks ■ ■ ■ ■
and insulation faultsFor measuring power values, ■ ■ ■ ■ ■ ■ ■
harmonics, etc.For the process and the 4-20/ ■
0-20 mA measurement loopPower supply
Stand-alone ■ ■ ■ ■ ■ ■
9 V battery ■ ■ ■ ■ ■
Mains adapter ■ ■ ■ ■ ■
Page 95 95 95 95 95 95 97 96 96 96 96
MIN
I
MN YN C1
XX
DN B1
XX
AmpF
LEX
K EN PAC
1x
PAC
2x
ASRAS CO.,LTD 1694, 1694/1 Prachasongkhro RoadDingdaeng, Dindaeng, Bangkok 10400 Tel. 02-692-3980, Fax 02-692-3978E-mail : [email protected] Website : www.asras.com
CURRENT MEASUREMENTCURRENT MEASUREMENT
Page � 92
Choose
Current sensors
Choosing your ammeter clamp
There is a wide range of criteria for choosing an ammeterclamp. The approach below is designed to help define yourrequirements and guide you naturally towards the model whichbest suits your application.
The criteria selected are classified from 1 to 6.
To choose your clamp, we advise you to followthis logic:
� Measurement of direct or alternating current?(AC/DC clamps or AC clamps tables )
� High or low currents? (see the “Input” column to define the appropriate familiesof clamps)
� On small wires or large cables? (see thediagrams at the bottom of the nextpage and only choose families withthe shapes and dimensionsrequired)
� What instrument will it be connect-ed to? (see “Input / Connection”column to choose a clamp withcompatible signal and connectionpossibilities)
� What are your other criteria? (see“Specific features” column to checkthat the clamp chosen fulfils yourrequirements perfectly)
K1
Page � 93
IEC 61010-2-032 clamps
Ammeter clamps
The widest range of IEC 1010 clamps
Our innovation, technical expertise and determination to man-ufacture top-quality products that comply with standards havemade Chauvin Arnoux the worldwide specialist in ammeterclamps.
On the next pages, you will find a table presenting the clampsfor measuring AC/DC current, followed by a diagram givingclamp form with dimensions and then another table groupinga large number of models for AC current.
As a result of their specifications, certain clamps are special-ized for specific applications.
� Clamps for oscilloscopes (BNC connectors): E3N, PAC12,PAC22, MN60, Y7N, C160, and D38N
� Clamps for leakage currents: MN73 and C173
� Process current clamps: K1 and K2
� Clamp for measurement on the secondary winding of currenttransformers: MN71
As well as these standardspecialized and unspecialized
models, “specific” versions canalso be produced on request:
please ask for details.MN60
Portable, on-site and laboratory test and measurement instruments � 2009 catalogue
CURRENT MEASUREMENTCURRENT MEASUREMENT
Page � 94
Current measurement
(1) The upper value corresponds to 120% of the maximum nominal value. (2) Lead + electronic unit with Ø 4 mm safety connectors, centre distance 19 mm, for K series
Ve
ry lo
w c
urr
en
t
Low
cu
rre
nt
Me
diu
m c
urr
en
t
Ho
cu
rre
nt
Cu
rre
nt
Vo
lta
ge
Lea
d +
sa
fety
plu
g ø
4 m
m(2
)F
em
ale
so
cke
ts ø
4 m
mB
NC
co
nn
ect
or (
osci
llosc
opes
)
Ou
tpu
t p
rote
cte
d a
gai
nst
ove
rvo
ltag
es
Au
tom
ati
c D
C z
ero
Po
we
r m
eas
ure
me
nt
(low
pha
se s
hift
)B
an
dw
ith
(fre
que
ncy
in H
z)
Typ
ica
l acc
ura
cy
Tra
nsf
orm
ati
on
ra
tio
(inp
ut/o
utp
ut)
AC DC
Measurement range (1)
Series Model
Input Output / Connections Specific features
Toorder
MN73 10 mA to 2.4 A100 mA to 240 A
2 V AC2 V AC
1 V AC
4 V AC0.4 V AC
2 V AC2 V AC
1 V AC
1 V AC
1.4 V AC/DC
4.5 V DC3 V RMS2 V peak
4.5 V DC3 V RMS2 V peak
1 V AC
1 V peak
600 mV AC/DC
3 V peak3 V peak2 V peak
1 A/1000 mV1 A/10 mV
40 Hz to10 kHz
10 Hz to3 kHz
10 Hz to 1 kHz
40 Hz to40 kHz
5 Hz to 10 kHz
10 Hz to100 kHz
30 Hz to50 kHz
DC to 100 kHz
DC to 10 kHz
DC to 10 kHz
DC to 2 kHz
DC to 1.5 kHz
40 Hz to 10 kHz
≤ 1%≤ 2%
≤ 0.7%≤ 0.5%≤ 0.3%≤ 0.2%
≤ 0.5%≤ 0.35%
≤ 2%≤ 1.5%
≤ 2%
≤ 3%≤ 2%≤ 1%
≤ 2%
≤ 3%≤ 4%
≤ 1.5%≤ 2%
≤ 1.5%≤ 2.5%
≤ 1%
≤ 1%
≤ 1%
> P01120421
> P01120309
> P01120083
> P01120409
> P01120075
> P01120308
> P01120057A
> P01120043A
> P01120072
> P01120073
> P01120067
> P01120074
> P01120420
1 mA to 1.2 A0.01 to 12 A0.1 to 120 A1 to 1200 A
500 µA to 4 A0.5 to 400 A
1 A/1V10 A/1V100 A/1V1000 A/1V
1 mA/1 mV1 A/1 mV
1 A/100 mV1 A/10 mV
1 mA/1 mV
10 A/1 V100 A/1 V1000 A/1 V
1 A/10 V1 A/1 mV
1 A/0.1 mV
1 A/100 mV1 A/10 mV
1 A/10 mV1 A/1 mV
1 A/10 mV1 A/1 mV
1 mA/1 mV
1 mA/10 mV
1 A/100 mV
0.1 to 60 A peak0.5 to 600 A
peak
1 A to 1200 Apeak
0.1 to 30 A peak1 to 300 A peak1 to 2000 A peak
1 to 90 A peak1 to 900 A peak1 to 9000 A peak
50 mA to 10 A peak1 to 100 A peak
0.2 to 60 A peak0.4 to 60 A DC
0.5 to 600 A peak0.5 to 600 A DC
0.2 to 150 A peak0.4 to 150 A DC
0.5 to 1400 A peak0.5 to 1400 A DC
1 mA to 14.5 A DC1 mA to 3 A RMS1 mA to 2 A peak
100 A to 450 mA DC100 A to 300 mA RMS100 A to 450 mA peak
10 mA to 12 A
C173
B102
MN60
Y7N
C160
D38N
E3N
PAC12
PAC22
K1
K2
MN71
Measurement on oscilloscope
Measurement of process current
Measurement on secondary widing of current transformers
Leak current measurement
Portable, on-site and laboratory test and measurement instruments � 2009 catalogue Page � 95
Current measurement AC
2 A to 150 A 0.15 A AC
1 A to 100 A 0.1 V AC
1000/1 48 Hz..500Hz ≤ 2.5 %
≤ 2 %
≤ 3 %≤ 2 %
≤ 4 %
48 Hz..500Hz
48 Hz..500Hz
48 Hz..500Hz
1A / 1mA
1mA / 1mV1A / 1mV
1A / 100mV1 A to 150 A 15 V DC
5 mA to 10 A1 A to 100 A
10 V AC0.1 V AC
Very
low
cur
rent
Low
cur
rent
Med
ium
cur
rent
Hot c
urre
nt
Curr
ent
Volta
ge
Lead
s + sa
fety
plu
g ø
4 m
m(2
)Fe
mal
e so
cket
s ø
4 m
mBN
C co
nnec
tor (
osci
llosc
opes
)
Auto
mat
ic D
C ze
roPo
wer
mea
sure
men
t (lo
w ph
ase
shift
)Ba
ndw
ith
(fre
quen
cy in
Hz)
Typi
cal a
ccur
acy
Tran
sfor
mat
ion
rati
o (i
nput
/out
put)
AC DC
Measurement range (1)
Outp
ut p
rote
cted
aga
inst
ove
rvol
tage
to
to
to
to
to
to
to
to
to
to
tototo
tototo
to
toto
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
toto
to
toto
to
toto
toto
to
to
totototototo
to
tototo
tototo
to
toto
to
toto
to
.
.
.
.
.
.
.
.
.
.
...
...
.
.
.
.
.
.
.
.
..
..
.
.
peakpeak
peak
peakpeakpeak
peakpeakpeak
.
.
.
.
.
.
.
.
.
.
.
peakpeakpeak
.
.
.
.
.
.
.
.
.
.
.
.
.
.
...
.
.
.
.
.
.
.
..
.
.
.
toto
(1) The higher value corresponds to 120% of the max. nominal value (2) Reshaping of AC signal by diodes.
Input Output / Connections Specific features
Series Model ToOrder
MINI 01MINI 03MINI 05MINI 09MN08MN09MN010MN011MN012MN013MN014MN015MN021MN023MN038MN039MN060MN071MN073MN088MN089Y1NY2NY3NY4NY7NC100C102C103C106C107C112C113C116C117C122C148
C160
C173
D30ND30CND31N
D32ND33ND34N
D35ND36N
D37N
D38N
> P01105001
> P01105002
> P01105003
> P01105004
> P01120401
> P01120402
> P01120403
> P01120404
> P01120405
> P01120406
> P01120416
> P01120417
> P01120418
> P01120419
> P01120407
> P01120408
> P01120409
> P01120420
> P01120421
> P01120410
> P01120415
> P01120001A
> P01120028A
> P01120029A
> P01120005A
> P01120075
> P01120301
> P01120302
> P01120303
> P01120304
> P01120305
> P01120314
> P01120315
> P01120316
> P01120317
> P01120306
> P01120307
> P01120308
> P01120309
> P01120049A
B102 > P01120083
> P01120064
> P01120050A
> P01120051A
> P01120052A
> P01120053A
> P01120054A
> P01120055A
> P01120056A
> P01120057A
31 mm
20 mm
18.5 mm
35 mm
35 mm
51 mm
66 mm
111 mm
310 mm
115 mm
135 mm
213 mm
216 mm
310 mm
48 mm
Ø 12 mm
Ø 20 mm
30 x 63 mm
Ø 52 mm
43 mm
151 mm
312 mm
Ø 100 mm max
64 x 150 mm
CURRENT MEASUREMENTCURRENT MEASUREMENT
Page � 96
Current measurement AC/DC
Adaptator for …
> E clamps > P01101965> K clamps > P01101966> PAC clamps > P01101967> AmpFLEXTM clamps > P01101968
Very
low
cur
rent
Low
cur
rent
Med
ium
cur
rent
Hot
curr
ent
Curr
ent
Volt
age
Lead
s +
safe
ty p
lug
ø 4
mm
(2)
Fem
ale
sock
ets
ø 4
mm
BNC
conn
ecto
r (os
cillo
scop
es)
Out
put
prot
ecte
d ag
ains
t ov
ervo
ltag
e
Auto
mat
ic D
C ze
roPo
wer
mea
sure
men
t (lo
w p
hase
shift
)Ba
ndw
ith
(fre
quen
cy in
Hz)
Typi
cal a
ccur
acy
Tran
sfor
mat
ion
rati
o (
inpu
t/ou
tput
)
AC DC
Measurement range (1)
peak
peak
tototo
tototo
.
.
toto
to
to
to
toto
to
toto
totototo
totototo
toto
toto
toto
toto
toto
..
..
. peak
peak
.
.
.
.
...
.
.
.
.
peak
peak
.
.
.
...
..
..
peak
peak
peak
peak
.
.
..
peak
.
.
.
.
.
.
.
.
.
.
.
(1) The higher value corresponds to 120 % of the max. nominal value (2) Lead + electronic housing with Ø 4 mm safety plugs, centre distance 19 mm, for K series.
Bring an unlimited autonomy to yourcurrent clamps: replace the battery withthe mains adapter plug
Series Model ToOrder
K1
K2
E1N
E3N
E6N
PAC10
PAC11
PAC12
PAC20
PAC21
PAC22
> P01120067
> P01120074
> P01120030A
> P01120043A
> P01120040A
> P01120070
> P01120068
> P01120072
> P01120071
> P01120069
> P01120073
15 mm
20 mm
26 mm
67 mm
97 mm
111 mm
231 mm
224 mm
97 mm
224 mm
20 mm
25 mm
Ø 3.9 mm
Ø 11.8 mm
50 x 10 mmor Ø 30 mm
50 x 12.5 mmor Ø 39 mm
Input Output / Connections Specific features
1 kA / 10 kAAmpFLEXTM
Portable, on-site and laboratory test and measurement instruments � 2009 catalogue Page � 97
Flexible current sensors
20 A / 200 A
The range is composed of 9 standard models*dedicated to the measurement of AC currentsfrom 0.5 A to 10 kA, at industrial frequencies.Each flexible core (48, 80 or 120 cm longdepending on the model) is connected by ashielded cable to a small box containing the
processing electronics and a standard 9 V bat-tery. The distance between the sockets (19 mm)facilitates direct connection to any type of mul-timeter, tester or recorder equipped with an ACvoltage input (impedance Z > 1 MΩ).The quick and simple system for opening/closing
the core makes it easy to handle even withsafety gloves.Other strong points: very lightweight (no mag-netic circuit), no saturation effect, highly accu-rate and very little phase shift (for wattmetermeasurements).
Flexibility and easy handling for clamping any conductorAmpFLEX™
* Specific models on request: consult us concerning the possiblesensitivities (mV/A) and lengths. We can also supply bare sensorsfor incorporation in assemblies including the signal processingelectronics.
- +
AmpFLEXTM
References to order Accessories / Spares
> Bring unlimited autonomy to your AmpFLEX™:replace the battery with the mains adapted plugAdaptator for AmpFLEXTM > P01101968
0.5 … 20A0.5 … 200A
2 V AC
2 V AC
0.5 … 2,000A
0.5 … 2,000A
0.5 … 200A0.5 … 2,000A0.5 … 200A
0.5 … 2,000A0.5 … 300A
0.5 … 3,000A0.5 … 300A
0.5 … 3,000A0.5 … 300A
0.5 … 3,000A0.5 … 1,000A0.5 … 10,000A
1A / 100mV1A / 10mV
1A / 10mV1A / 1mV1A / 10mV1A / 1mV1A / 10mV1A / 1mV1A / 10mV1A / 1mV1A / 10mV1A / 1mV1A / 1mV
1A / 0.1mV
10 … 20kHz ≤ 1 %
≤ 1 %
≤ 1 %
≤ 1 %
≤ 1 %
≤ 1 %
≤ 1 %
≤ 1 %
≤ 1 %
10 … 20kHz
10 … 20kHz
10 … 20kHz
10 … 20kHz
10 … 20kHz
10 … 20kHz
10 … 20kHz
10 … 20kHz
1A / 1mV
1A / 1mV2 V AC
2 V AC
2 V AC
3 V AC
3 V AC
3 V AC
1 V AC
Very
low
cur
rent
Low
cur
rent
Med
ium
cur
rent
Hot c
urre
nt
Curr
ent
Volta
ge
Lead
s + sa
fety
plu
g ø
4 m
m(2
)Fe
mal
e so
cket
s ø
4 m
mBN
C co
nnec
tor (
osci
llosc
opes
)
Auto
mat
ic D
C ze
roPo
wer
mea
sure
men
t (lo
w ph
ase
shift
)Ba
ndw
ith
(fre
quen
cy in
Hz)
Typi
cal a
ccur
acy
Tran
sfor
mat
ion
rati
o (i
nput
/out
put)
AC DC
Measurement range (1)
Outp
ut p
rote
cted
aga
inst
ove
rvol
tage
Models To order
20A/200A (45 cm)
2 kA (45 cm)
2 kA (80 cm)
200A/2kA (45 cm)
200A/2kA (80 cm)
300A/3kA (45 cm)
300A/3kA (80 cm)300A/3kA (120 cm)
1/10 kA (120 cm)
> P01120503
> P01120501
> P01120502
> P01120504
> P01120505
> P01120506
> P01120507
> P01120508
> P01120509
ASRAS Co.,LTD1694, 1694/1 Prachasongkhro Road.Dindaeng, Dindaeng, Bangkok 10400Tel. 02-692-3980, Fax. 02-692-3978E-mail : [email protected] : www.asras.com ; www.asras.co.th