Culvert Catalog
Transcript of Culvert Catalog
P. O. Box 1061Dunn, North Carolina 28335(910) 892-6411 fax: (910) 892-48941-866-PRECASTwww.carolinaprecast.com
Setting the Standard
CAROLINAPRECAST
BOX CULVERTS
Box Culverts
Box Culvert Sections Page
Precast Box Culvert; Single Cell 2
Precast Box Culvert; Multiple Cell 3
Precast Box Culvert; Multi Cell – Composite 4
Box Culvert 3-Sided Boxes Page
Precast Box Culvert 3 Sided Box with Footer Slabs 5
Precast Box Culvert 3 Sided Box with Top Slab 6
Box Culvert Bend Details Page
Precast Box Culvert Bend Details 7
Box Culvert End Details Page
Precast Box Culvert End Treatment Detail 8
Precast Box Culvert Skewed Ends 9
Precast Box Culvert Special End Standards (1) 10
Precast Box Culvert Special End Standards (2) 11
Precast Box Culvert Special End Standards (3) 12
1
SEE NOTE #7
LAY LENGTH BARRIER SECTIONS UP TO 7'-6" TYPICAL
1. PRECAST BOX CULVERT DESIGN SPECIFICATIONS SHALL BE IN ACCORDANCE WITH ACI-318 "BUILDING REQUIREMENTS FOR STRUCTURAL CONCRETE", AASHTO "STANDARD SPECIFICATIONS FOR HIGHWAY BRIDGES", ASTM C789 "PRECAST REINFORCED CONCRETE BOX SECTIONS FOR CULVERTS, STORM DRAINS, AND SEWERS, OR ASTM C850 "PRECAST REINFORCED CONCRETE BOX SECTIONS FOR CULVERTS, STORM DRAINS, AND SEWERS WITH LESS THAN 2 Ft. OF COVER SUBJECT TO HIGHWAY LOADINGS", AS APPLICABLE.2. CONCRETE COMPRESSIVE STRENGTH 5,000 P.S.I. MINIMUM UNLESS OTHERWISE SPECIFIED.3. STEEL REINFORCING DESIGN TO CONFORM TO THE REQUIREMENTS OUTLINED IN NOTE #1 AND SHALL UTILIZE GRADE 60 RE-BARS CONFORMING TO THE REQUIREMENTS OF ASTM A185, OR WWF CONFORMING TO THE REQUIREMENTS OF ASTM A185 OR BOTH.4. TYPICAL HAUNCH DETAIL SHALL BE 8"x8". LARGER HAUNCHES ARE AVAILABLE FOR CULVERTS OF LONGER SPANS, DEEPER FILLS OR HEAVY LIVE LOAD REQUIREMENTS.5. WALL, ROOF, AND FLOOR DIMENSIONS SHALL BE DETERMINED BY JOB CONDITIONS. TYPICAL CONFIGURATIONS AS WELL AS STEEL REQUIREMENTS ARE DETAILED IN ASTM C789 AND C850 AS PER NOTE #1.6. PENETRATIONS IN ROOF SLAB AND WALLS CAN BE PROVIDED DEPENDENT ON JOB CONDITIONS. ADDITIONAL STEEL WILL BE REQUIRED AT ALL PENETRATIONS.7. WEEP HOLES AVAILABLE PER JOB REQUIREMENTS AND ARE TYPICALLY PLACED ONE PER CULVERT SECTION AT EACH EXTERIOR WALL.8. TONGUE AND GROOVE SHALL BE SIZED IN PROPORTION TO CULVERT CROSS SECTION. JOINTS SHALL BE SEALED BY 1"x1" CLOSE CELL NEOPRENE SPONGE GASKET MATERIAL WHICH IS FACTORY APPLIED TO THE "BELL" OR "GROOVE" END OF THE CULVERT SECTION.9. SEE SPECIAL DETAILS FOR END TREATMENTS, CURVES, AND ADDITIONAL OPTIONS AVAILABLE.
GENERAL NOTES:
DETAILS PROVIDED BY APPIAN CONSULTING ENGINEERS, P.A.
NOTE #8
SEE
SEE NOTE #5
SEE NOTE #5
AND DETAIL
SEE NOTE #8SEE NOTE #6
SEE
NO
TE #
5
SEE
NO
TE #
5
TYPICAL SPANSMIN. 6'-0" AND UP(1'-0" INCREMENTS)
(1'-0
" IN
CR
EMEN
TS)
MIN
. 3'-0
" A
ND
UP
TYPI
CA
L R
ISER
SEE NOTE #3
SEE NOTE #4
SIN
GL
E C
EL
LP
RE
CA
ST
BO
X C
ULV
ER
T
NOTE #6SEE
FEB. 15, 1999
BOXCUL-SDRAWING No:
DATE:P. O. Box 1061Dunn, North Carolina 28335(910) 892-6411 fax: (910) 892-48941-866-PRECASTwww.carolinaprecast.comSetting the Standard
CAROLINAPRECAST
© 2007 Carolina Precast Concrete, Inc.
2
LAY LENGTH BARRIER SECTIONS UP TO 7'-6" TYPICAL
1. PRECAST BOX CULVERT DESIGN SPECIFICATIONS SHALL BE IN ACCORDANCE WITH ACI-318 "BUILDING REQUIREMENTS FOR STRUCTURAL CONCRETE", AASHTO "STANDARD SPECIFICATIONS FOR HIGHWAY BRIDGES", ASTM C789 "PRECAST REINFORCED CONCRETE BOX SECTIONS FOR CULVERTS, STORM DRAINS, AND SEWERS, OR ASTM C850 "PRECAST REINFORCED CONCRETE BOX SECTIONS FOR CULVERTS, STORM DRAINS, AND SEWERS WITH LESS THAN 2 Ft. OF COVER SUBJECT TO HIGHWAY LOADINGS", AS APPLICABLE.2. CONCRETE COMPRESSIVE STRENGTH 5,000 P.S.I. MINIMUM UNLESS OTHERWISE SPECIFIED.3. STEEL REINFORCING DESIGN TO CONFORM TO THE REQUIREMENTS OUTLINED IN NOTE #1 AND SHALL UTILIZE GRADE 60 RE-BARS CONFORMING TO THE REQUIREMENTS OF ASTM A185, OR WWF CONFORMING TO THE REQUIREMENTS OF ASTM A185 OR BOTH.4. TYPICAL HAUNCH DETAIL SHALL BE 8"x8". LARGER HAUNCHES ARE AVAILABLE FOR CULVERTS OF LONGER SPANS, DEEPER FILLS OR HEAVY LIVE LOAD REQUIREMENTS.5. WALL, ROOF, AND FLOOR DIMENSIONS SHALL BE DETERMINED BY JOB CONDITIONS. TYPICAL CONFIGURATIONS AS WELL AS STEEL REQUIREMENTS ARE DETAILED IN ASTM C789 AND C850 AS PER NOTE #1.6. PENETRATIONS IN ROOF SLAB AND WALLS CAN BE PROVIDED DEPENDENT ON JOB CONDITIONS. ADDITIONAL STEEL WILL BE REQUIRED AT ALL PENETRATIONS.7. WEEP HOLES AVAILABLE PER JOB REQUIREMENTS AND ARE TYPICALLY PLACED ONE PER CULVERT SECTION AT EACH EXTERIOR WALL.8. TONGUE AND GROOVE SHALL BE SIZED IN PROPORTION TO CULVERT CROSS SECTION. JOINTS SHALL BE SEALED BY 1"x1" CLOSE CELL NEOPRENE SPONGE GASKET MATERIAL WHICH IS FACTORY APPLIED TO THE "BELL" OR "GROOVE" END OF THE CULVERT SECTION.9. SEE SPECIAL DETAILS FOR END TREATMENTS, CURVES, AND ADDITIONAL OPTIONS AVAILABLE.10. PRECAST CULVERT SECTIONS CAN BE PRODUCED MONOLITHICALLY IN MULTI-CELL CONFIGURATIONS AND MUST SPECIFY IN REQUIREMENTS.
GENERAL NOTES:
DETAILS PROVIDED BY APPIAN CONSULTING ENGINEERS, P.A.
NOTE #8
SEE
SEE NOTE #6
NOTE #7SEE
SEE NOTE #8AND DETAIL
MIN. 6'-0" AND UP(1'-0" INCREMENTS)
SEE
NO
TE #
5
SEE
NO
TE #
5SEE NOTE #3
TYPICAL SPANS
SEE NOTE #4
SEE NOTE #5
PR
EC
AS
T B
OX
CU
LVE
RT
MU
LTIP
LE
CE
LL
SEE
NOTE #6TY
PICA
L RI
SER
MIN
. 3'-0
" AND
UP
(1'-0
" INC
REM
ENTS
)
SEE NOTE #5
SEE NOTE #5
FEB. 15, 1999
BOXCUL-MDRAWING No:
DATE:P. O. Box 1061Dunn, North Carolina 28335(910) 892-6411 fax: (910) 892-48941-866-PRECASTwww.carolinaprecast.comSetting the Standard
CAROLINAPRECAST
© 2007 C
arolina Precast C
oncrete, Inc.
3
1. PRECAST BOX CULVERT DESIGN SPECIFICATIONS SHALL BE IN ACCORDANCE WITH ACI-318 "BUILDING REQUIREMENTS FOR STRUCTURAL CONCRETE", AASHTO "STANDARD SPECIFICATIONS FOR HIGHWAY BRIDGES", ASTM C789 "PRECAST REINFORCED CONCRETE BOX SECTIONS FOR CULVERTS, STORM DRAINS, AND SEWERS, OR ASTM C850 "PRECAST REINFORCED CONCRETE BOX SECTIONS FOR CULVERTS, STORM DRAINS, AND SEWERS WITH LESS THAN 2 Ft. OF COVER SUBJECT TO HIGHWAY LOADINGS", AS APPLICABLE.2. CONCRETE COMPRESSIVE STRENGTH 5,000 P.S.I. MINIMUM UNLESS OTHERWISE SPECIFIED.3. STEEL REINFORCING DESIGN TO CONFORM TO THE REQUIREMENTS OUTLINED IN NOTE #1 AND SHALL UTILIZE GRADE 60 RE-BARS CONFORMING TO THE REQUIREMENTS OF ASTM A185, OR WWF CONFORMING TO THE REQUIREMENTS OF ASTM A185 OR BOTH.4. TYPICAL HAUNCH DETAIL SHALL BE 8"x8". LARGER HAUNCHES ARE AVAILABLE FOR CULVERTS OF LONGER SPANS, DEEPER FILLS OR HEAVY LIVE LOAD REQUIREMENTS.5. WALL, ROOF, AND FLOOR DIMENSIONS SHALL BE DETERMINED BY JOB CONDITIONS. TYPICAL CONFIGURATIONS AS WELL AS STEEL REQUIREMENTS ARE DETAILED IN ASTM C789 AND C850 AS PER NOTE #1.6. PENETRATIONS IN ROOF SLAB AND WALLS CAN BE PROVIDED DEPENDENT ON JOB CONDITIONS. ADDITIONAL STEEL WILL BE REQUIRED AT ALL PENETRATIONS.7. WEEP HOLES AVAILABLE PER JOB REQUIREMENTS AND ARE TYPICALLY PLACED ONE PER CULVERT SECTION AT EACH EXTERIOR WALL.8. TONGUE AND GROOVE SHALL BE SIZED IN PROPORTION TO CULVERT CROSS SECTION. JOINTS SHALL BE SEALED BY 1"x1" CLOSE CELL NEOPRENE SPONGE GASKET MATERIAL WHICH IS FACTORY APPLIED TO THE "BELL" OR "GROOVE" END OF THE CULVERT SECTION.9. SEE SPECIAL DETAILS FOR END TREATMENTS, CURVES, AND ADDITIONAL OPTIONS AVAILABLE.10. MULTI-CELL CONFIGURATION MAY BE BUT ACCOMPLISHED BY REPEATED ROWS OF SINGLE CELL CROSS SECTIONS. THIS IS PRIMARILY DUE TO CONSTRAINTS ON SITE DUE TO WEIGHT HANDLING LIMITATIONS.11. A 1" SPACING BETWEEN ROWS FILLED WITH GRANULAR MATERIAL IS DESIRABLE TO ASSUME PROPER LOAD DISTRIBUTION. PRECAST NOSING STEMS ARE AS REQUIRED.
GENERAL NOTES:
& NOTE #11SEE DETAIL
DETAILS PROVIDED BY APPIAN CONSULTING ENGINEERS, P.A.
LAY LENGTH BARRIER SECTIONS
UP TO 7'-6" TYPICALSEENOTE #8
SEE NOTE #11
NOTE #6
NOTE #7SEE
AND DETAIL
SEE NOTE #8SEE
MIN. 6'-0" AND UP(1'-0" INCREMENTS)
SEE
NO
TE #
5
SEE
NO
TE #
5SEE NOTE #3
TYPICAL SPANS
SEE NOTE #4
MU
LTI C
EL
L -
CO
MP
OS
ITE
PR
EC
AS
T B
OX
CU
LVE
RT
NOTE #6SEE
NOTE #7
SEE
OPTIONALNOSING
PRECAST
MIN
. 3'-0
" AND
UP
(1'-0
" INC
REM
ENTS
)
TYPI
CAL
RISE
R
SEE NOTE #5FILL WITH
MORTAR
SEE NOTE #5
FEB. 15, 1999
BOXCUL-CDRAWING No:
DATE:P. O. Box 1061Dunn, North Carolina 28335(910) 892-6411 fax: (910) 892-48941-866-PRECASTwww.carolinaprecast.comSetting the Standard
CAROLINAPRECAST
© 2007 C
arolina Precast C
oncrete, Inc.
4
ALTERNATE PRECAST
SEE NOTE #10OR POURED IN
1. PRECAST BOX CULVERT DESIGN SPECIFICATIONS SHALL BE IN ACCORDANCE WITH ACI-318 "BUILDING REQUIREMENTS FOR STRUCTURAL CONCRETE", AASHTO "STANDARD SPECIFICATIONS FOR HIGHWAY BRIDGES", ASTM C789 "PRECAST REINFORCED CONCRETE BOX SECTIONS FOR CULVERTS, STORM DRAINS, AND SEWERS, OR ASTM C850 "PRECAST REINFORCED CONCRETE BOX SECTIONS FOR CULVERTS, STORM DRAINS, AND SEWERS WITH LESS THAN 2 Ft. OF COVER SUBJECT TO HIGHWAY LOADINGS", AS APPLICABLE.2. CONCRETE COMPRESSIVE STRENGTH 5,000 P.S.I. MINIMUM UNLESS OTHERWISE SPECIFIED.3. STEEL REINFORCING DESIGN TO CONFORM TO THE REQUIREMENTS OUTLINED IN NOTE #1 AND SHALL UTILIZE GRADE 60 RE-BARS CONFORMING TO THE REQUIREMENTS OF ASTM A185, OR WWF CONFORMING TO THE REQUIREMENTS OF ASTM A185 OR BOTH.4. TYPICAL HAUNCH DETAIL SHALL BE 8"x8". LARGER HAUNCHES ARE AVAILABLE FOR CULVERTS OF LONGER SPANS, DEEPER FILLS OR HEAVY LIVE LOAD REQUIREMENTS.5. WALL, ROOF, AND FLOOR DIMENSIONS SHALL BE DETERMINED BY JOB CONDITIONS. TYPICAL CONFIGURATIONS AS WELL AS STEEL REQUIREMENTS ARE DETAILED IN ASTM C789 AND C850 AS PER NOTE #1.6. PENETRATIONS IN ROOF SLAB AND WALLS CAN BE PROVIDED DEPENDENT ON JOB CONDITIONS. ADDITIONAL STEEL WILL BE REQUIRED AT ALL PENETRATIONS.7. WEEP HOLES AVAILABLE PER JOB REQUIREMENTS AND ARE TYPICALLY PLACED ONE PER CULVERT SECTION AT EACH EXTERIOR WALL.8. TONGUE AND GROOVE SHALL BE SIZED IN PROPORTION TO CULVERT CROSS SECTION. JOINTS SHALL BE SEALED BY 1"x1" CLOSE CELL NEOPRENE SPONGE GASKET MATERIAL WHICH IS FACTORY APPLIED TO THE "BELL" OR "GROOVE" END OF THE CULVERT SECTION.9. SEE SPECIAL DETAILS FOR END TREATMENTS, CURVES, AND ADDITIONAL OPTIONS AVAILABLE.10. THIS IS A GOOD SOLUTION FOR ENVIRONMENTALLY SENSITIVE AREAS WHERE STREAM BEDS CAN NOT BE DISTURBED.
GENERAL NOTES:
PLACE FOOTER SLAB
DETAILS PROVIDED BY APPIAN CONSULTING ENGINEERS, P.A.
NOTE #8
SEE
SEE NOTE #5
UP TO 7'-6" TYPICAL
LAY LENGTH BARRIER SECTIONS
SEE NOTE #7
SEE NOTE #8SEE
NO
TE #
5
SEE
NO
TE #
5
SEE NOTE #6
AND DETAIL
TYPICAL SPANSMIN. 6'-0" AND UP(1'-0" INCREMENTS)
MIN
. 3'-0
" A
ND
UP
TYPI
CA
L R
ISER
(1'-0
" IN
CR
EMEN
TS)
SEE NOTE #3
FOOTER
SEE NOTE #4
3 S
IDE
D B
OX
WIT
H F
OO
TE
R S
LA
BS
PR
EC
AS
T B
OX
CU
LVE
RT
NOTE #6SEE
FEB. 15, 1999
BOXCUL-FDRAWING No:
DATE:P. O. Box 1061Dunn, North Carolina 28335(910) 892-6411 fax: (910) 892-48941-866-PRECASTwww.carolinaprecast.comSetting the Standard
CAROLINAPRECAST
© 2007 C
arolina Precast C
oncrete, Inc.
5
DRAWING No:
DATE:
1. PRECAST BOX CULVERT DESIGN SPECIFICATIONS SHALL BE IN ACCORDANCE WITH ACI-318 "BUILDING REQUIREMENTSFOR STRUCTURAL CONCRETE", AASHTO "STANDARD SPECIFICATIONS FOR HIGHWAY BRIDGES", ASTM C789 "PRECASTREINFORCED CONCRETE BOX SECTIONS FOR CULVERTS, STORM DRAINS, AND SEWERS, OR ASTM C850 "PRECASTREINFORCED CONCRETE BOX SECTIONS FOR CULVERTS, STORM DRAINS, AND SEWERS WITH LESS THAN 2 Ft. OF COVERSUBJECT TO HIGHWAY LOADINGS", AS APPLICABLE.
2. CONCRETE COMPRESSIVE STRENGTH 5,000 P.S.I. MINIMUM UNLESS OTHERWISE SPECIFIED.3. STEEL REINFORCING DESIGN TO CONFORM TO THE REQUIREMENTS OUTLINED IN NOTE #1 AND SHALL UTILIZE GRADE
60 RE-BARS CONFORMING TO THE REQUIREMENTS OF ASTM A185, OR WWF CONFORMING TO THE REQUIREMENTS OFASTM A185 OR BOTH.
4. TYPICAL HAUNCH DETAIL SHALL BE 8"x8". LARGER HAUNCHES ARE AVAILABLE FOR CULVERTS OF LONGER SPANS,DEEPER FILLS OR HEAVY LIVE LOAD REQUIREMENTS.
5. WALL, ROOF, AND FLOOR DIMENSIONS SHALL BE DETERMINED BY JOB CONDITIONS. TYPICAL CONFIGURATIONS AS WELLAS STEEL REQUIREMENTS ARE DETAILED IN ASTM C789 AND C850 AS PER NOTE #1.
6. PENETRATIONS IN ROOF SLAB AND WALLS CAN BE PROVIDED DEPENDENT ON JOB CONDITIONS. ADDITIONAL STEELWILL BE REQUIRED AT ALL PENETRATIONS.
7. WEEP HOLES AVAILABLE PER JOB REQUIREMENTS AND ARE TYPICALLY PLACED ONE PER CULVERT SECTION AT EACHEXTERIOR WALL.
8. TONGUE AND GROOVE SHALL BE SIZED IN PROPORTION TO CULVERT CROSS SECTION. JOINTS SHALL BE SEALED BY1"x1" CLOSE CELL NEOPRENE SPONGE GASKET MATERIAL WHICH IS FACTORY APPLIED TO THE "BELL" OR "GROOVE"END OF THE CULVERT SECTION.
9. SEE SPECIAL DETAILS FOR END TREATMENTS, CURVES, AND ADDITIONAL OPTIONS AVAILABLE.10. THIS SECTION MAY BE USED FOR VARIOUS APPLICATIONS WHERE IT IS DESIRABLE TO GAIN ACCESS TO A TRENCH
OR INSTALL PIPING OR UTILITIES BEFORE CLOSING TOP SECTION.DETAILS PROVIDED BY APPIAN CONSULTING ENGINEERS, P.A.
GENERAL NOTES:UP TO 7'-6" TYPICAL
LAY LENGTH BARRIER SECTIONS
SEE NOTE #7NOTE #8
SEE
3 S
IDE
D B
OX
WIT
H T
OP
SL
AB
PR
EC
AS
T B
OX
CU
LVE
RT
SEE
NOTE #6
SEE
NO
TE #
5
SEE
NO
TE #
5
SEE NOTE #6
AND DETAIL
SEE NOTE #8
(1'-0" INCREMENTS)MIN. 6'-0" AND UP
TYPICAL SPANS
SEE NOTE #5
PRECAST REMOVABLE TOP SHELF
TYPI
CA
L R
ISER
MIN
. 3'-0
" A
ND
UP
(1'-0
" IN
CR
EMEN
TS)
SEE NOTE #4
SEE NOTE #3
FEB. 15, 1999
BOXCUL-T
P. O. Box 1061Dunn, North Carolina 28335(910) 892-6411 fax: (910) 892-48941-866-PRECASTwww.carolinaprecast.comSetting the Standard
CAROLINAPRECAST
© 2007 C
arolina Precast C
oncrete, Inc.
6
MODERATELY EXPENSIVE
DETAILS PROVIDED BY APPIAN CONSULTING ENGINEERS, P.A.
COULD BE EXPENSIVE DEPENDING ON CONFIGURATION
TIGHT BEND - MITER JOINTANGLES AS REQUIRED UP TO 45°SPECIAL JOINT SECTION REQUIRED,LIMITED BY CROSS SECTION CONFIGURATIONS
MAKE A TURN.MOST COST EFFECTIVE WAY TODEPENDING ON JOB CONFIGURATIONS.
STEEL REINFORCING.WELDING OF REBAR TO PROVIDE CONTINUOUS
ANGLE AS REQUIREDSPECIAL CULVERT SECTION REQUIRED TO BEHAND BUILT INCORPORATING A COLD JOINT AND
TYPICALLY 5° TO 10° PER JOINT
TIGHT BEND - SPECIAL SECTION
SWEEP BEND - TAPERED JOINT
BE
ND
DE
TAIL
SP
RE
CA
ST
BO
X C
ULV
ER
T
FEB. 15, 1999
BOXCUL-BDRAWING No:
DATE:P. O. Box 1061Dunn, North Carolina 28335(910) 892-6411 fax: (910) 892-48941-866-PRECASTwww.carolinaprecast.comSetting the Standard
CAROLINAPRECAST
© 2007 Carolina Precast Concrete, Inc.
7
1. #4 DOWEL BAR SPLICERS MAY BE CAST IN TO FACILITATE TIE IN TO CAST IN PLACE HEADWALLS, WING WALLS AND FOOTINGS.2. REBAR MAY BE EXTENDED TO FACILITATE TIE INS IN LIEU OF NOTE #1.3. PRECAST END WALL DESIGNS ARE AVAILABLE TO CREATE CONTAINMENT STRUCTURES. CALL C.P.C. ENGINEERING DEPARTMENT FOR FURTHER DETAILS.4. EMBEDDED WALL PLATES MAY BE PROVIDED TO ACCOMMODATE SPECIAL JOB CONDITIONS.
SEE NOTE #4
GENERAL NOTES:
SEE NOTE #3
DETAILS PROVIDED BY APPIAN CONSULTING ENGINEERS, P.A.
SEE NOTE #4
SEE NOTE #2
EN
D T
RE
AT
ME
NT
DE
TAIL
PR
EC
AS
T B
OX
CU
LVE
RT
SEE NOTE #1
FEB. 15, 1999
BOXCUL-EDRAWING No:
DATE:P. O. Box 1061Dunn, North Carolina 28335(910) 892-6411 fax: (910) 892-48941-866-PRECASTwww.carolinaprecast.comSetting the Standard
CAROLINAPRECAST
© 2007 C
arolina Precast C
oncrete, Inc.
8
SEE NOTE #2
1. STANDARD SKEWED ANGLE MAY BE LIMITED DUE TO SECTION LENGTH AS RELATED TO SPAN OF CULVERT. SPECIAL LENGTH END SECTIONS CAN BE PRODUCED TO INCREASE SKEWED ANGLE.2. SPECIAL SKEW CONFIGURATION CAN BE ACHIEVED IN SINGLE AND MULTIPLE CELL CULVERTS BY INCORPORATING A PRECAST HEADWALL INTO THE END DESIGN. CALL CAROLINA PRECAST ENGINEERING DEPARTMENT FOR FURTHER DETAILS.
DETAILS PROVIDED BY APPIAN CONSULTING ENGINEERS, P.A.
LAY LENGTH BARRIER SECTIONS
GENERAL NOTES: 1'-6" MIN.
UP TO 7'-6" TYPICALTWIN
SK
EW
ED
EN
DS
PR
EC
AS
T B
OX
CU
LVE
RT
NOTE #1
UP TO 7'-6" TYPICAL
LAY LENGTH BARRIER SECTIONS
1'-6" MIN.
SINGLE
SEE
FEB. 15, 1999
BOXCUL-KDRAWING No:
DATE:P. O. Box 1061Dunn, North Carolina 28335(910) 892-6411 fax: (910) 892-48941-866-PRECASTwww.carolinaprecast.comSetting the Standard
CAROLINAPRECAST
© 2007 Carolina Precast Concrete, Inc.
9
DRILL & DOWELTAPERED END
IN FIELD
PRECAST FOOTER
DETAILS PROVIDED BY APPIAN CONSULTING ENGINEERS, P.A.
DOWEL BAR SPLICERS
SECOND POUR
TAPERED ENDS MAY BE USED
PART OF END SECTION
ECONOMICAL ALTERNATIVE
PROVIDE A PRACTICAL AND
IN LIEW OF WINGWALLS TO
PRECAST HEADWALL
CAST AS INTEGRAL
SP
EC
IAL
EN
D S
TAN
DA
RD
SP
RE
CA
ST
BO
X C
ULV
ER
T
FEB. 15, 1999
BOXCUL-W1DRAWING No:
DATE:P. O. Box 1061Dunn, North Carolina 28335(910) 892-6411 fax: (910) 892-48941-866-PRECASTwww.carolinaprecast.comSetting the Standard
CAROLINAPRECAST
© 2007 Carolina Precast Concrete, Inc.
10
CONNECTION
DETAILS PROVIDED BY APPIAN CONSULTING ENGINEERS, P.A.
DRILL & DOWEL
FIELD CONNECTION
SP
EC
IAL
EN
D S
TAN
DA
RD
SP
RE
CA
ST
BO
X C
ULV
ER
T
BOLT ANGLE
FEB. 15, 1999
BOXCUL-W2DRAWING No:
DATE:P. O. Box 1061Dunn, North Carolina 28335(910) 892-6411 fax: (910) 892-48941-866-PRECASTwww.carolinaprecast.comSetting the Standard
CAROLINAPRECAST
© 2007 Carolina Precast Concrete, Inc.
11
1. PRECAST WING WALL SECTIONS ARE AVAILABLE TO CREATE A TOTAL PRECAST SOLUTION. THESE SECTIONS ARE READILY AVAILABLE IN PRECAST CONCRETE, HOWEVER, SECTION WEIGHTS AND JOB CONDITIONS MAY LIMIT THE CONTRACTORS ABILITY TO HANDLE THIS PRODUCT OR LARGER CULVERT SECTIONS.
GENERAL NOTES:
DETAILS PROVIDED BY APPIAN CONSULTING ENGINEERS, P.A.
DRILL & DOWELPRECAST FOOTER
IN FIELD
PART OF END SECTION
PRECAST HEADWALL
CAST AS INTEGRAL
PR
EC
AS
T B
OX
CU
LVE
RT
SP
EC
IAL
EN
D S
TAN
DA
RD
S
FEB. 15, 1999
BOXCUL-W3DRAWING No:
DATE:P. O. Box 1061Dunn, North Carolina 28335(910) 892-6411 fax: (910) 892-48941-866-PRECASTwww.carolinaprecast.comSetting the Standard
CAROLINAPRECAST
© 2007 Carolina Precast Concrete, Inc.
12