120” CMP CulvertPanel Lok IIIE

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.QuickTime™ and a

Photo - JPEG decompressorare needed to see this picture.

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.QuickTime™ and a

Photo - JPEG decompressorare needed to see this picture.

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.

Page 3: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.QuickTime™ and a

Photo - JPEG decompressorare needed to see this picture.

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.QuickTime™ and a

Photo - JPEG decompressorare needed to see this picture.

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.

Rebar Beam Bolsters Used As Annulus Spacers

Page 4: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.QuickTime™ and a

Photo - JPEG decompressorare needed to see this picture.

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.QuickTime™ and a

Photo - JPEG decompressorare needed to see this picture.

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.

Annulus Spacers (Beam Bolsters) Welded to CMP

Page 5: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

78” CMP Covington, GA

Liner ID= 74"

Ø = 30°

78" ID CMP Culvert Covington, GA

20 -7/16"on inside surface of CMP

Circumferential distance between 1.5" height beam bolsters

1.5"5"

5 feet lengthsRebar Beam Bolster

PVC Liner Required 19.6'/ft of pipe Grout Required = 4.2 CF/ft of pipe (Assuming 1" deep corrugations)

NTS

NTS

Side View

End View

Page 6: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

Twin 120” CMP Culverts - Illinois

Page 7: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

108” Cement Coated Cinder Brick Storm Drain

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.QuickTime™ and a

Photo - JPEG decompressorare needed to see this picture.

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.QuickTime™ and a

Photo - JPEG decompressorare needed to see this picture.

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.

Page 8: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

90” Storm Sewer Washington, DC

Page 9: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

90” Storm Sewer Washington, DC

Page 10: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

90” Storm Sewer Washington, DC

Page 11: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

7½ Ft x 15 FT Stone Arch – Ohio DOT

Page 12: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

7½ Ft x 15 FT Stone Arch – Ohio DOT

Page 13: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

11’-7” x 7’-5” CMP Kingston, NY

Page 14: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

11’x7’ Box Culvert Storm Sewer-Baltimore

Page 15: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

11’x7’ Box Culvert Storm Sewer-Baltimore

Page 16: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

12’-6” x 7’-11” CMPA – Ohio DOT

Page 17: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

12’-6” x 7’-11” CMPA – Ohio DOT

Page 18: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

12’-6” x 7’-11” CMPA – Ohio DOT

Page 19: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

60” Storm Sewer Syracuse, NY

Page 20: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

60” Storm Sewer Syracuse, NY

Page 21: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.QuickTime™ and a

Photo - JPEG decompressorare needed to see this picture.

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.QuickTime™ and a

Photo - JPEG decompressorare needed to see this picture.

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.

44”x72” Culvert - Boise, Idaho

Page 22: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.QuickTime™ and a

Photo - JPEG decompressorare needed to see this picture.

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.QuickTime™ and a

Photo - JPEG decompressorare needed to see this picture.

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.

Grouting Invert - Boise Culvert

Page 23: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.QuickTime™ and a

Photo - JPEG decompressorare needed to see this picture.

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.QuickTime™ and a

Photo - JPEG decompressorare needed to see this picture.

QuickTime™ and aPhoto - JPEG decompressor

are needed to see this picture.

Boise Culvert Finished Job

Page 24: Www.danbyrehab.com CULVERT REHABILITATION.  120” CMP Culvert Panel Lok IIIE.

www.danbyrehab.com

A Proven Solution