Clamp-on ultrasonic flow meter - ISOILarchivio.isoil.eu/IFX-_CLAMP-ON_ENG.pdf · IFX-P200 –...

6
Clamp-on ultrasonic flow meter

Transcript of Clamp-on ultrasonic flow meter - ISOILarchivio.isoil.eu/IFX-_CLAMP-ON_ENG.pdf · IFX-P200 –...

Page 1: Clamp-on ultrasonic flow meter - ISOILarchivio.isoil.eu/IFX-_CLAMP-ON_ENG.pdf · IFX-P200 – ULTRASONIC FLOW METER “CLAMP-ON” TYPE ... for detailed characteristics refer to individual

Clamp-on ultrasonic flow meter

Page 2: Clamp-on ultrasonic flow meter - ISOILarchivio.isoil.eu/IFX-_CLAMP-ON_ENG.pdf · IFX-P200 – ULTRASONIC FLOW METER “CLAMP-ON” TYPE ... for detailed characteristics refer to individual

IFX-P200 – ULTRASONIC FLOW METER “CLAMP-ON” TYPE

Dimensions

• Very robust and light portable Ultrasonic Flow Meter with graphic LCD.

• Non-intrusive portable measurement suitable for pipes in different materials and for diameters from DN10 up to DN3000 with a choice of sensors.

• Suitable for any liquid regardless conductivity, pressure or chemical characteristics.

• User friendly menu with setup assistance for easy and fast operations.

• Audible Sensor Positioning Assistant for easier sensor mounting.

• Measuring principle based on transit time with dual DSP technology for improved accuracy.

• Integral Data logger able to store up to 100.000 measurement, each including up to 10 units, and dedicated software for PC data download.

• Bidirectional measurement with totalizing function.

• Single sensor able to cover application from DN50 up to DN3000.

• Robust IP65 transport case.

• Optional magnetic rail or mounting accessory.

• Optional integral wall thickness gauge.

• Operates also connected to mains through the battery charge port.

TECHNICAL DATA

Measuring Principle Transit time

Velocity range 0,01 - 25 m/s

Resolution 0,25 mm/s

Repeatability 0,15% of measured value

Accuracy (Flow/Volume) ±1-3% of measured value depending on application ±0,5% of measured value with process calibration against master meter

Accuracy (velocity) ±0,5% of measured value

Measurement rate 1 Hz as standard

Response time 1 second

Damping of reading 0...99 seconds (selectable)

Solids and gas content in media <10% in volume

Enclosure Robust ABS housing with rubber shock protector

Protection rate IP65

Ambient temperature –10 +60 °C (for electronics)

Supply Internal rechargeable batteries

Operation time up to 24 hours with fully charged batteries

Display LCD graphic with back light

Weight (Approx.) 0,65 kg (instrument only)7 kg (transport case with instrument and sensors)

Operating languages English, Spanish, Italian (other on request)

124 mm

58 mm

248

mm

160 mm 81 mm

61 mm20 mm

120

mm

155

mm

270 mm

285

mm

175

mm

124 mm

58 mm

248

mm

160 mm 81 mm

61 mm20 mm

120

mm

155

mm

270 mm

285

mm

175

mm

PORTABLE INSTRUMENT

Page 3: Clamp-on ultrasonic flow meter - ISOILarchivio.isoil.eu/IFX-_CLAMP-ON_ENG.pdf · IFX-P200 – ULTRASONIC FLOW METER “CLAMP-ON” TYPE ... for detailed characteristics refer to individual

Dimensions

Dimensions

124 mm

58 mm

248

mm

160 mm 81 mm

61 mm20 mm

120

mm

155

mm

270 mm

285

mm

175

mm

TECHNICAL DATA

Measurement principle Ultrasonic transit-time difference

Measurement type on line non-invasive

Flow velocity range ±0.01 ... 25 m/s

Resolution 0,25 mm/s

Repeatability 0,15% of measured value, ±0.015 m/s

Accuracy (Flow/Volume) ±1-3% of measured value depending on application ±0,5% of measured value with process calibration

Flow velocity (mean) ±0,5% of measured value

Measurement rate 100 Hz (standard)

Pipe diameter range (25 mm) 50 mm to 3000 mm (larger pipe based on material)

Temperature range for sensors –30 to +130 °C (–22 to +266 °F)

Housing Rugged integrated IP 67 - portable

Display LCD display and full keypad

Battery life up to 100 days with internal battery

Power supply 1, 2 or 3 x LiFePo4 12.4 Ah

Power adapter 100 ... 240 V AC input, 9 V DC output

Operating time 1 Cell: up to 7 days continuous operation, 30 days in hibernation mode*

2 Cells: up to 14 days continuous operation, 60 days in hibernation mode*

3 Cells: up to 21 days continuous operation, 100 days in hibernation mode* Unlimited when connected to main through the battery charge port

Dimensions 260 (h) x 280 (w) x 200 (d) mm

Weight (Approx.) 6.0 kg

Operating languages English, Spanish, Italian (other on request)

IFX-P210 – BATTERY OPERATED “CLAMP-ON” ULTRASONIC FLOW METERDESIGNED FOR TEMPORARY SITE INSTALLATION

• Portable, compact flow meter designed for applications requiring rugged and waterproof instrument.

• Large battery capacity intended for long-term installation in remote areas where access to power is limited and exposure to the elements is likely.

• Robust and sealable IP67 housing granting measurement and instrument safety.

• Easy and fast to install thanks to non-invasive sensors based on transit time ultrasonic principle.

• One sensors pair to cover any process pipe from DN 50 to DN 3000.

• Integral logger allowing up to 1.000.000 of measure records.

• Modular battery packages and different operational mode to extend unattended site measuring life up to more than 3 months.

• Suitable for a variety of applications from water network for leak detection and district metering, to temporary replace in line flow meter, to industrial installation on corrosive or dangerous media.

• Delivered with dedicated software for data download and management.

• Optional 4-20 mA, pulse or relay process output.

• Optional magnetic rail or mounting accessory.

• Optional integral wall thickness gauge.

• Operates also connected to mains through the battery charge port.

* Based on normal operating conditions, with no process output enabled.

Page 4: Clamp-on ultrasonic flow meter - ISOILarchivio.isoil.eu/IFX-_CLAMP-ON_ENG.pdf · IFX-P200 – ULTRASONIC FLOW METER “CLAMP-ON” TYPE ... for detailed characteristics refer to individual

www.isoil.com

Dimensions

• Flow transmitter with backlight LCD display and 5 keys board programming.

• Non-intrusive fixed measurement suitable for pipes in different materials and for diameter from DN10 up to DN3000 with a choice of sensors.

• Suitable for any liquid regardless conductivity, pressure or chemical characteristics.

• User friendly menu for easy and fast operations.

• Audible Sensor Positioning Assistant for easier sensor mounting.

• Measuring principle based on transit time with dual DSP technology for improved accuracy.

• Bidirectional measurement with totalizing function.

• Optionaly Digital or Analog outputs including Modbus, RTU e HART Protocol.

• On request Energy calculation function including Pt100 sensors input module. Requires clamp-on Pt100 sensors.

124 mm

58 mm

248

mm

160 mm 81 mm

61 mm20 mm

120

mm

155

mm

270 mm

285

mm

175

mm

TECHNICAL DATA

Measuring Principle Transit time

Velocity range 0,01 - 25 m/s

Resolution 0,25 mm/s

Repeatability 0,15% of measured value

Accuracy (Flow/Volume) ±1-3% of measured value depending on application ±0,5% of measured value with process calibration against master meter

Accuracy (velocity) ±0,5% of measured value

Measurement rate 1 Hz as standard

Response time 1 second

Damping of reading 0...99 seconds (selectable)

Solids and gas content in media <10% in volume

Housing Die cast Aluminium for wall mounted

Protection rate IP66

Ambient temperature –10 +60 °C (for electronics)

Power supply 100...240 VAC or 9...36 VDC

Power consumption <5 W

Display LCD graphic with back light

Weight (Approx.) 0,75 kg

Operating languages English, Spanish, Italian (other on request)

IFX-F100 – ULTRASONIC FLOW METER “CLAMP-ON” TYPE FOR FIXED INSTALLATIONS

Page 5: Clamp-on ultrasonic flow meter - ISOILarchivio.isoil.eu/IFX-_CLAMP-ON_ENG.pdf · IFX-P200 – ULTRASONIC FLOW METER “CLAMP-ON” TYPE ... for detailed characteristics refer to individual

ULTRASONIC SENSORS FOR PORTABLE METERS

ULTRASONIC SENSORS FOR FIXED METERS

www.isoil.com

SENSOR TYPE K1N / K1E

Pipe diameter 50...3000 mm

Sensor dimensions 60 x 30 x 34 mm

Sensor head material Stainless Steel

Cable conduit material Stainless Steel

Working temperature –30 +130 °C (–30 + 250 °C for K1E)

Protection rate IP 68

Cable length 4 m standard (on request other lengths)

SENSOR TYPE K1P / K1L / K1N / K1E

Pipe diameter 50...3000 mm

Sensor dimensions 60 x 30 x 34 mm

Sensor head material Stainless Steel (plastic for K1P)

Cable conduit material PVC (Stainless Steel for K1E/K1N)

Working temperature K1P –20 +50 °C K1L –30 +80 °CK1N –30 +130 °CK1E –30 + 250 °C

Protection rate IP 68

Cable length K1P: 3 m K1L: 5 mK1N / K1E: 4 m

(on request other lengths)

SENSOR TYPE K4N / K4E

Pipe diameter 10...250 mm

Sensor dimensions 43 x 18 x 22 mm

Sensor head material Stainless Steel

Cable conduit material Stainless Steel

Working temperature –30 +130 °C (–30 + 250 °C for K4E)

Protection rate IP 68

Cable length 2,5 m standard (on request other lengths)

SENSOR TYPE K4L / K4N / K4E

Pipe diameter 10...250 mm

Sensor dimension 43 x 18 x 22 mm

Sensor head material Stainless Steel

Cable conduit material PVC (Stainless Steel for K4E/K4N)

Working temperature K4L –30 +80 °CK4N –30 +130 °CK4E –30 + 250 °C

Protection rate IP 68

Cable length K4L: 5 mK4N / K4E: 2,5 m

(on request other lengths)

Page 6: Clamp-on ultrasonic flow meter - ISOILarchivio.isoil.eu/IFX-_CLAMP-ON_ENG.pdf · IFX-P200 – ULTRASONIC FLOW METER “CLAMP-ON” TYPE ... for detailed characteristics refer to individual

d

a b

v

tab tba

www.isoil.com

ISOIL INDUSTRIA SPACinisello Balsamo - Milano (Italy)

Via Fratelli Gracchi, 27 tel. +39 0266027.1 - fax +39 026123202

www.isoil.com [email protected]

01/2

016

g

andi

ni-r

endi

na.c

omTH

E M

AN

UFA

CTU

RER

RESE

RVES

TH

E RI

GH

T TO

CH

AN

GE

DA

TA &

SPE

CIF

ICA

TIO

NS

WIT

HO

UT

NO

TIC

E.

Information shown in this brochure are not exhaustive, for detailed characteristics refer to individual data sheet.

The ultrasonic flow meter specifically designed for water treatment and chemical industry.

Transit time measuring principle.

Sensors “a” and “b” work alternately to send and receive ultrasonic pulses.

The sound waves “a” to “b” travelling with the flow move faster than those “b” to “a” travelling against it; the time difference is the flow velocity.

Figure shows typical V reflection mounting, where sensors are installed on the same external side of pipe, different installation ways can be used to manage different pipe size and material.

Measuring principle

ACCESSORIES

A list of accessories are available for easy mounting or for improving the measuring results like:

• Integral wall thickness gauge for IFX-P200 or IFX-P210 – for direct connection on the meter

• External wall thickness gauge also suitable for fixed meters

• Magnetic rails

• Clamp on temperature sensors for energy measurement

• Clips and Mounting accessories

• Acoustical Paste

• Extension cables

Magnetic mounting rail

Wall tickness gaugePT100 transducer fixed to pipe