Clamp meters...1466 Clamp meters AC/DC ClAmp meters • True RMS measurements • 3-3/4 digit LCD...
Transcript of Clamp meters...1466 Clamp meters AC/DC ClAmp meters • True RMS measurements • 3-3/4 digit LCD...
1466
Clamp metersAC/DC ClAmp meters• TrueRMSmeasurements• 3-3/4digitLCDwithhigh-speed,42-segmentbargraph• Max/MinandDataHoldfunctions• PeakHoldfunction• Frequencymeasurement• Diodeandcontinuitytestwithbeeper• Polarityandoverloadindications• Autoormanualranging• Autopower-off• Lowbatteryindication• ConformstoEN610101000VCat.II,600VCat.III• IncludesIa181testleads,6AM6X
batteryandHN416carryingcase• Accreditedcalibrationavailable
SpecificationS:Current range: 40A,400A,1000AAC/DCresolution: 0.01A,0.1A,1AAC/DCaccuracy: AC:±(1.9%rdg.+5dgt.);
DC:±(2.5%rdg.+10dgt.)Voltage range: AC:400V,750V;DC:400V,1000Vresolution: 0.1,1VAC/DCaccuracy: AC:±(1.5%rdg.+5dgt.);DC:±(1%rdg.+2dgt.)resistance range: 400Ω,4000Ωresolution: 0.1Ω,1Ωaccuracy: ±(1%rdg.+3dgt.)Frequency range: A&V:4kHz,10kHzresolution: 1Hz,10Hzaccuracy: A-Hz:±(0.1%rdg.+1dgt.)(20Hz-10kHz); V-Hz:±(0.1%rdg.+1dgt.)(10Hz-10kHz)Continuity range: <100Ωtest Current range: 1.7mAmax.power supply: Single9VbatteryBattery life: Approx.100hoursJaw Opening: 40mmDimensions: 242x66x36mmWeight: 400g
Model No. Mfg. No. Description Price/Each
HX161 R5050 True RMS AC/DC Clamp Meter HX357 AC-006 AC Line Splitter
HX161
Pantone 534 BluePantone 123 Yellow
Pantone 485 RedPantone 123 Yellow
Pantone 534 Blue
Black Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:Pantone 534 Blue - 100/80/30/5Pantone 485 Red - 10/100/100/5Pantone 123 Yellow - 0/27/100/
Pantone 534 BluePantone 123 Yellow
Pantone 485 RedPantone 123 Yellow
Pantone 534 Blue
Black Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:Pantone 534 Blue - 100/80/30/5Pantone 485 Red - 10/100/100/5Pantone 123 Yellow - 0/27/100/
AC/DC ClAmp meters• FullfunctionautorangingDMMincludesAC/DCvoltageandcurrent,
resistance,capacitance,frequency,dutycycle,diodeandcontinuity• Currentmeasurementsto2000 Athrough
theclampand240 mAviatestleads• Large5000countbacklitdisplayforhighresolution• BasicDCVaccuracyof1%with0.1 mV
resolutionandcurrentresolutionto0.1 µA• 2.36"(60 mm)clampjawopening(750 MCM)• DCcurrentpushbuttonzero,
relativemeasurementsandDataHold• Heavy-dutyABScasewithbuilt-instand
andthumbcontrolfunctionswitch
SpecificationS:DC/aC Current range (Clamp): 240,2000 ADC/aC Current range (Dmm): 240,2400 µA,24,240 mADC/aC Voltage range: 2.4,24,240,1000 VCapacitance range: 25,250 nF,2.5,25µFresistance range: 240 Ω,2.4,24,240 kΩ,2.4,24 MΩFrequency range: 50,500 Hz,5,50,100 kHzDuty Cycle range: 0.1%to99.9%
Model No. Mfg. No. Description Price/Each
HN415 CM-9930 AC/DC Clamp-On Meter
Pantone 534 BluePantone 123 Yellow
Pantone 485 RedPantone 123 Yellow
Pantone 534 Blue
Black Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:Pantone 534 Blue - 100/80/30/5Pantone 485 Red - 10/100/100/5Pantone 123 Yellow - 0/27/100/
AC/DC ClAmp meter• MeasuresACandDCvoltageandcurrent,resistance,
capacitanceandfrequencyaswellastemperaturewiththeincludedtypeKthermocoupleprobe
• TrueRMSACmeasurements• Diodeandcontinuitytestwithbeeper• 50000-countdigitaldisplaywith61-segmentanalog• Autoormanualranging• Doublemoldedplastichousing• ConformstoEN61010600VCat.III• Includestestleads,temperature
probe,9Vbatteryandcase• AC/DCrange:500/1000A
Model No. Mfg. No. Description Price/Each
IB065 R5040 AC/DC Clamp Meter
true rms AC/DC ClAmp meter• MeasuresAC/DCcurrent,AC/DCvoltage,resistance,
capacitance,frequency,dutycycle,andtemperaturewithatypeKthermocoupleprobe
• TrueRMSACmeasurements• Non-contactACvoltagedetectorinclamptip• Lowbatteryindicationandautopower-off• 50000countLCDwithbacklight• ConformstoEN61010Cat.III600V• Jawopening:1.2"(30mm)• Includessetoftestleads,temperatureprobe,
batteries,andsoftcarryingcase
SpecificationS:aC/DC Current range: 50.00,500.0Aaccuracy: AC:±(2.8%rdg.+30dgt.);DC:±(2.5%rdg.+30dgt.)aC Voltage range: 500.00mV,5.0000,50.000,500.00,750.0Vaccuracy: ±(1.0%rdg.+30dgt.)DC Voltage range: 500.00mV,5.0000,50.000,500.00,1000.0Vaccuracy: ±(0.1%rdg.+4dgt.)resistance range: 500.00Ω,5.000,50.000,500.00kΩ,5.0000,50.000MΩaccuracy: ±(1.0%rdg.+4dgt.)Frequency range: 10.000kHzaccuracy: ±(0.5%rdg.+10dgt.)Capacitance range: 500.00,5000.0nF,50.00,500.0μF,5.000mFaccuracy: ±(3.5%rdg.+10dgt.)temperature range: -100.0to1000.0°C/-148.0to1832.0°F
AC/DC ClAmp meter• MeasuresACcurrent,ACandDCvoltage,
resistance,capacitance,aswellastemperaturewiththeincludedTypeKthermocoupleprobe
• Diodetestandcontinuitycheck• 4000-countLCDdisplayslowbattery
andoverrangeindications• ULapproved• Cat.III600Vsafetyrating• Includesonesetoftestleads,onetemperature
probe,batteries,andasoftcarryingcase
SpecificationS:aC Current range: 40.00,400.0Aaccuracy: ±(2.5%rdg.+8dgt.)DC Voltage range: 400.0mV,4.000,40.00,400.0,600.0Vaccuracy: ±(1.5%rdg.+2dgt.)aC Voltage range: 4.000,40.00,400.0,600.0Vaccuracy: ±(1.8%rdg.+8dgt.)resistance range: 400.0Ω,4.000,40.00,
400.0kΩ,4.000,40.00MΩaccuracy: ±(1.5%rdg.+2dgt.)Capacitance range: 40.00,400.0nF,4.000,40.00,100.0µFaccuracy: ±(3%rdg.+5dgt.)temperature range: -20.0to760.0°C(-4.0to1400.0°F)accuracy: ±(3%rdg.+5°C/9°F)Jaw Opening: 1.2"(30mm)maximumpower supply: 2x1.5V"AAA"batteriesDimensions: 200x66x37mmWeight: 205g
Model No. Mfg. No. Description Price/Each
IA982 R5020 AC/DC Clamp Meter
Model No. Mfg. No. Description Price/Each
IB685 R5030 True RMS AC/DC Clamp Meter
Pantone 534 BluePantone 123 Yellow
Pantone 485 RedPantone 123 Yellow
Pantone 534 Blue
Black Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:Pantone 534 Blue - 100/80/30/5Pantone 485 Red - 10/100/100/5Pantone 123 Yellow - 0/27/100/
Pantone 534 BluePantone 123 Yellow
Pantone 485 RedPantone 123 Yellow
Pantone 534 Blue
Black Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:Pantone 534 Blue - 100/80/30/5Pantone 485 Red - 10/100/100/5Pantone 123 Yellow - 0/27/100/
OFFICe prODuCts
INstrumeNts, sCales &
eleCtrICal
sHIppINg & paCkagINg
tOOls & equIpmeNt
WelDINg & metalWOrkINg
saFety equIpmeNt & supplIes
JaNItOrIal & maINteNaNCe
materIal HaNDlINg &
stOrage
1467
INsulatION testers
SpecificationS:Insulation resistance teststest Voltage: 250 V,500 V,1000 Vmeasurement range: 200 MΩ,2000 MΩaccuracy: ±3.5%rdg.±5 dgt.resistance testsmeasurement range: 200 Ω,2000 Ωaccuracy: ±1%rdg.±2 dgt.Voltage testsmeasurement range: 750 VAC;1000 VDCaccuracy: AC:±1.2%rdg.±10 dgt. DC:±0.8%rdg.±3 dgt.Continuity testsmeasurement range: Beeps≤40 Ωtest Current: ≤200 mAgeneralpower supply: 6x1.5 VAAbatteriesDimensions: 200x92x50 mmWeight: 700 g
SpecificationS:Nominal test Voltages: 50 V,100 V,250 V,
500V,1000VInsulation resistance range: 2to200GΩanalogue range: 1GΩfullscaleshort Circuit Current: 2mA+0%-50%leakage Current range: 10µAto2000µAleakage Current accuracy: 10%rdg.±3dgt.Voltage Display: 3%rdg.±3dgt.±0.5%ofratedvoltagepolarisation Index (pI): 10min/1minuteratioDielectric absorption ratio (Dar): 60sec/30secratioContinuity range: 0.01to99.9Ω(0to100Ωonanaloguescale)accuracy: ±2%rdg.±2dgt.(0to100Ω)Open Circuit Voltage: 5V±1Vtest Current: 205mA(±5mA)(0.01to9.99Ω);
20mA(±1mA)(10.0to99.9Ω)Buzzer: Variablelimit,1Ω,2Ω,5Ω,10Ω,20Ωresistance range: 0.01to1000kΩ(0to1MΩonanaloguescale)accuracy: ±3%rdg.±2dgt.upto50kΩ,
then±5%rdg.±2dgt.Open Circuit Voltage: 5V±1Vshort Circuit Current: 1.5mA±0.2mAVoltage range: 0to600VDCaccuracy: ±2%rdg.±2dgt.Frequency range: 40to450Hzaccuracy: ±0.5%rdg.±1dgt.Capacitance range: 100pFto10µFaccuracy: ±5.0%rdg.±2dgt.storage Capacity: >1000testresultspower supply: 5x1.5V,Alkalinebatteries,
NiMHrechargeablecellsmaybeusedBattery life: 2200insulationtestswithdutycycleof5sec
ON/55secOFF@1000Vinto1MΩDimensions: 220x92x50mm(8.66x3.63x1.97")Weight: 590g(20.73oz)
Pantone 534 BluePantone 123 Yellow
Pantone 485 RedPantone 123 Yellow
Pantone 534 Blue
Black Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:Pantone 534 Blue - 100/80/30/5Pantone 485 Red - 10/100/100/5Pantone 123 Yellow - 0/27/100/
Pantone 534 BluePantone 123 Yellow
Pantone 485 RedPantone 123 Yellow
Pantone 534 Blue
Black Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:Pantone 534 Blue - 100/80/30/5Pantone 485 Red - 10/100/100/5Pantone 123 Yellow - 0/27/100/
InsulAtIon testers InsulAtIon/ContInuIty testers • Testvoltagecombinations:
250 V,500 Vor1000 V• 1 mAtestcurrentforMΩ
rangeatratedvoltage• 200 mAtestcurrentforcontinuityrange• Continuitytestwithbeeper• Large,easy-to-readdual
displaywithbacklight
• Dataholdswitch• Testbuttonmaybelocked
onforhands-freeoperation• Doublemouldedplastichousing• Suppliedwithtestleads,batteries
andplasticcarryingcase• MeetsIEC61010-1Cat.III1000 V
• PolarisationIndex(PI)andDielectricAbsorptionRatio(DAR)functionsaswellastestresultsstorage
• Includedaccessories:Red/blacksiliconeleadsetwithclips,protectiverubberboot
• DesignedtomeetthesafetyrequirementsforuseonCATIV600V
Model No. Mfg. No. Description Price/Each
IA194 ST-5500 Insulation Tester
Model No. Mfg. No. Description Price/Each
IA811 MIT420 Insulation/Continuity Tester
Model No. Mfg. No. Description Price/Each
IA855 R5002 Insulation Tester
InsulAtIon testers• Measurementsfrom500Vto5000Vandupto60GΩ• Sourcesupto1.2mAcurrentduringteststooffsetcapacitanceload• Dielectricabsorptionratiomeasurements(DAR)• Polarizationindexmeasurement(PI)• Timesetmeasurementfunction• Auto-dischargefunctionandvoltageoutputwarningfunction• Livecircuitwarningsymbolsplusaudiblewarning• Livecircuitdetectionprevents
insulationtestif>30Visdetected• Max/Min,Peak,Relativevalue
andDataHoldfunctions• 6000-countdigitaldisplay
withbargraphandbacklight• MeetsIEC61010-1Cat.IV
600Vsafetystandards• Includestestleads,
batteriesandcarryingcase• Accreditedcalibrationavailable
SpecificationS:Insulation resistancetest Voltages: 500V,1000V,2500V,5000VDCInsulation resistance range: 0to60.0GΩresistance test range: 0.1to6000ΩVoltage range: 0.5to600.0VAC/DC
InsulAtIon testers• Acompactandeasy-to-useinsulationandcontinuitytester
thatisidealformorearduousenvironments• Threeinsulationtestranges:250V,500V,1000V• Continuityrange:3Ωand500Ω• 200mAmeasuringcurrentoncontinuitytesting• Livecircuitwarningbuzzerandneonlamp• Automaticdischargeofcircuitcapacitance• Dustanddripproofconstruction(designedtoIP54)model No. Ia193 mfg. No. KEW3132A price/each $
see pages 556 - 558 for electrical safety clothing
& protection
materIal HaNDlINg &
stOrage
JaNItOrIal & maINteNaNCe
saFety equIpmeNt & supplIes
WelDINg & metalWOrkINg
tOOls & equIpmeNt
sHIppINg & paCkagINg
INstrumeNts, sCales &
eleCtrICal
OFFICe prODuCts
1468
CapaCItaNCe, pHase & eartH grOuND testers
CAble trACers• Allcomponentsarefullyfuse
protectedandintrinsicallysafe;andfitintoafoam-linedcarryingcase
• ModelR2000Receiverhastwodetectorsinitstipwhicharetunedtopickuptheelectromagneticsignals('short'mode)orelectrostaticsignals('open'mode)generatedbyothercomponents
• LEDsandsensitivitysettingsindicatetherelativesignalstrengthtoalloweasydetectionofthesignalsource
• ModelS2600LoadSignalGenerator,whenconnectedtoanenergizedline,willdrawarapidlyfluctuatingcurrentpulsefromthesource,causingthepowerlinetoemitanelectromagneticsignalwhichisdetectedbytheR2000inthe'short'mode
• ModelT2200Transmitterinjectsasignalintoanunenergizedconductor.Iftheconductorisbroken(open),nocurrentwillflow,sothesignalispresentasavoltagepulse,whichisdetectedalongtheconductor'slengthbytheR2000'selectrostaticdetector('open'mode)
• ModelA2201InductiveClampwhenclampedaroundtheenergizedlineandpluggedintotheT2200willinduceasignalontothedownstream(load)sidetoenableidentificationofequipmentonthatcircuit
• Includes:Receiver,loadsignalgenerator,transmitter,clamp-ontransmitteraccessory,cordsetsandadapter
phAse rotAtIon InDICAtorswith open phaSe checker• Designedtocheckthepresenceofanopen
phaseandalsothephasesequencewithrotatingdisksandlamps
• Verifiesawiderangeof3-phasepowersourcesfrom110 Vto600 V
• Colour-codedintegratedtestleadseliminatetheriskofmisconnectionandmeterdamage
Model No. Mfg. No. Description Price/Each
IA185 KEW8031 Phase Rotation Indicator
Model No. Mfg. No. Description Price/Each
IA854 R5001 LCR/Capacitance Meter
Model No. Mfg. No. Description Price/Each
IA856 R5003 AC Voltage/Current Data Logger
Model No. Mfg. No. Description Price/Each
HD909 AT-2004 Cable Tracing System
Model No. Mfg. No. Description Price/Each
IA857 R5004 Phase Sequence/Motor Rotation Tester
lCr/CApACItAnCe meters• Measureinductance/capacitance/resistance
withsecondaryparametersincludingdissipationfactor(D),qualityfactor(Q),phaseangle(Ø),equivalentseries/parallelresistance(ESRorRp)
• AutorangingoperationforACimpedanceandDEresistancemeasurement
• AutoLCRsmartcheckandmeasurement• Series/Parallelmodes• Ls/Lp/CpwithD/Q/Ø/ESRparameters• SupportDCRmode200to200MΩ• Highaccuracywith4or5terminal
Kelvinmeasurement• Testingfrequencyisupto10kHzand
outputfrequencyisupto100kHz• Includestestleadsandbatteries• Accreditedcalibrationavailable
SpecificationS:Inductance range: 2000.0µH/20.000/200.0/2000.0mH/20.000/200.00/2000.0HCapacitance range: 2000.0pF/20.000/200.00/2000.0nF/20.00/200.00/2000µFresistance range: 20.000/200.00Ω/2.0000/20.000/200.00kΩ/2.0000/20.000/200.0MΩtest Frequencies: 100/120/1k/10k/100kHz
VoltAge/Current DAtA loggers• Simultaneouslymeasure2TrueRMS
ACvoltageinputsOR2ACcurrentinputsOR1ACvoltageand1ACcurrentinput
• Userprogrammablesampleratesfrom1secondto24hours
• Storesupto256,000measurements• Userprogrammablehigh/lowalarms• LCDindicatestime/date,current
readings,Max/Min,Peakholdandwhetheralarmsettingshavebeenexceeded
• DownloadcollecteddatathroughUSBinterface
• Autopoweroffandbatterycheck• IncludesACcurrentclampsensor
andvoltagesensor,USBcable,software,andbattery
• Accreditedcalibrationavailable
SpecificationS:aC Current range: 10to200AaC Voltage range: 10to600V
phAse sequenCe testers• Testsphaseorientationof3-phasepowersources• Indicatesphaseorientation(clockwiseorcounter-clockwise)
andwhethereachofthethreephasesislive• Alsoindicatesdirectionofmotorrotation• Determinesmotorrotationwithoutcontact• Easytoopenalligatorclipswithwidejaws• Doublemoldedhousing• Cat.III600Vsafetyrating• InputVoltage:40to600VAC• OperatingFrequency:2to400Hz• Completewithcableswith3colour-coded
alligatorclips,9Vbatteryandcarryingcase• Accreditedcalibrationavailable
Pantone 534 BluePantone 123 Yellow
Pantone 485 RedPantone 123 Yellow
Pantone 534 Blue
Black Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:Pantone 534 Blue - 100/80/30/5Pantone 485 Red - 10/100/100/5Pantone 123 Yellow - 0/27/100/
Pantone 534 BluePantone 123 Yellow
Pantone 485 RedPantone 123 Yellow
Pantone 534 Blue
Black Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:Pantone 534 Blue - 100/80/30/5Pantone 485 Red - 10/100/100/5Pantone 123 Yellow - 0/27/100/
Pantone 534 BluePantone 123 Yellow
Pantone 485 RedPantone 123 Yellow
Pantone 534 Blue
Black Rich Black - 20/20/20/100
Blue - 100/80/30/5Yellow - 0/27/100/0
Red - 10/100/100/5Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:Pantone 534 Blue - 100/80/30/5Pantone 485 Red - 10/100/100/5Pantone 123 Yellow - 0/27/100/
see pages 1377 - 1379 for Insulated hand tools
OFFICe prODuCts
INstrumeNts, sCales &
eleCtrICal
sHIppINg & paCkagINg
tOOls & equIpmeNt
WelDINg & metalWOrkINg
saFety equIpmeNt & supplIes
JaNItOrIal & maINteNaNCe
materIal HaNDlINg &
stOrage