Clamp-On Meters · 2013-10-10 · Category AC Clamp Meters AC/DC Clamp Meters Leakage Clamp Meters...

2
Clamp-On Meters SELECTOR GUIDE www.yokogawa-usa.com 2 Dar t Road Newnan, GA 30265 770-254-0400 • 800-888-6400 Fax: 770-251-2088 http://www.yokogawa-usa.com Represented by: Since our establishment in the United States in 1957, Yokogawa Corporation of America (YCA) has become a leading North American manufacturer and supplier of Test and Measurement, Field Instrumentation (Flow, Pressure and Analytical Products), Process Control Equipment, Information Products. Headquartered just south of Atlanta, Georgia, YCA has sales offices across the United States. Our commitment to our customers is our number one priority, and we back it up with a network of representatives and distributors that reflect this commitment. Our 132 manufacturing and service locations give us a presence on every major continent, which means we have the global resources to support all your application needs. Our parent company, Yokogawa Electric Corporation, is dedicated to developing the most advanced control and instrumentation products and systems in the world. As a major global player, the company anticipates the needs of the times, continually tackling new challenges and exploring new markets in order to provide the best solutions in the world. Yokogawa’s commitment to innovation is reflected in our extraordinary investments in R&D, which ensure development of the most advanced products and services. As a result, we have secured more than 4,500 patents and registrations, representing a number of important innovations, including the world’s first distributed control system and the first digital sensors for flow and pressure measurement. PG CL-E; REV1 NOV. 2011 A Commitment to Innovation PG CL-E

Transcript of Clamp-On Meters · 2013-10-10 · Category AC Clamp Meters AC/DC Clamp Meters Leakage Clamp Meters...

Page 1: Clamp-On Meters · 2013-10-10 · Category AC Clamp Meters AC/DC Clamp Meters Leakage Clamp Meters MODEL CL120 CL130 CL135 CL150 CL155 CL220 CL235 CL250 CL255 CL320 CL340 CL345 CL360

Clamp-On Meters

SELECTOR GUIDE

www.yokogawa-usa.com

2 Dart RoadNewnan, GA 30265770-254-0400 • 800-888-6400Fax: 770-251-2088http://www.yokogawa-usa.com

Represented by:

Since our establishment in the United States in 1957, Yokogawa Corporation of America (YCA) has become a leading North American manufacturer and supplier of Test and Measurement, Field Instrumentation (Flow, Pressure and Analytical Products), Process Control Equipment, Information Products.

Headquartered just south of Atlanta, Georgia, YCA has sales offices across the United States. Our commitment to our customers is our number one priority, and we back it up with a network of representatives and distributors that reflect this commitment. Our 132 manufacturing and service locations give us a presence on every major continent, which means we have the global resources to support all your application needs.

Our parent company, Yokogawa Electric Corporation, is dedicated to developing the most advanced control and instrumentation products and systems in the world. As a major global player, the company anticipates the needs of the times, continually tackling new challenges and exploring new markets in order to provide the best solutions in the world. Yokogawa’s commitment to innovation is reflected in our extraordinary investments in R&D, which ensure development of the most advanced products and services. As a result, we have secured more than 4,500 patents and registrations, representing a number of important innovations, including the world’s first distributed control system and the first digital sensors for flow and pressure measurement.

PG CL-E; REV1 NOV. 2011

A Commitment to Innovation

PG CL-E

Page 2: Clamp-On Meters · 2013-10-10 · Category AC Clamp Meters AC/DC Clamp Meters Leakage Clamp Meters MODEL CL120 CL130 CL135 CL150 CL155 CL220 CL235 CL250 CL255 CL320 CL340 CL345 CL360

Category AC Clamp Meters AC/DC Clamp Meters Leakage Clamp Meters

MODEL CL120 CL130 CL135 CL150 CL155 CL220 CL235 CL250 CL255 CL320 CL340 CL345 CL360 30031A 30032A

Appearance

MEAN MEAN RMS MEAN RMS MEAN RMS MEAN RMS MEAN MEAN RMS MEAN MEAN MEAN

Display 3.5 digits 1999 counts

3.5 digits 1999 counts

3.5 digits 1999 counts

3.5 digits 4000 counts

3.5 digits 4000 counts

3.5 digits 4000 counts

3.5 digits 3999 counts

3.5 digits 3999 counts

3.5 digits 3999 counts

3.5 digits 1999 counts

3.5 digits 3999 counts 6000 counts (40/400mA)

3.5 digits 4200 counts 6000 counts (40/400mA)

3.5 digits 1999 counts

3.5 digits 3200 counts

3.5 digits 3200 counts

40Hz - 1kHz 45Hz - 1kHz 40Hz - 1kHz 40Hz - 1kHz 40Hz - 1kHz DC, 20Hz - 1kHz DC, 10Hz - 1kHz DC, 40Hz - 1kHz DC, 30Hz - 1kHz 40 - 400Hz 20Hz - 1kHz 20Hz - 1kHz 40Hz - 1kHz 50/60Hz 50/60Hz

ɸ24mm ɸ33mm ɸ33mm ɸ55mm ɸ55mm ɸ24mm ɸ33mm ɸ55mm ɸ55mm ɸ24mm ɸ40mm ɸ40mm ɸ68mm ɸ40mm ɸ40mm

Measurement ACA 200A 600A 600A 2000A 2000A 300A 600A 2000A 2000A 20m/200m/200A 40m/400m/400A 40m/400m/400A 3m/30m/30/60A 3m/30m/30/60A

Resolution 0.01A 0.1A 0.1A 0.1A 0.1A 0.01A 0.1A 0.1A 0.1A 0.01mA 0.01mA 0.01mA 0.1mA 0.001mA 0.001mA

Accuracy @50/60Hz (% rdg + digit)2.0 + 7 (20 A)

2.0 + 5 (200 A)1.5 + 6 (200 A) 1.0 + 3 (600 A)

1.5 + 41.0 +3

3.0% (1500-2000 A)1.0 +3

3.0% (1500-2000 A)

1.0 + 4 (40 A) 1.5 +4 (20-200 A

@300 A) 3.5% (200-300 A)

1.5 + 51.5 + 2

3.0 +2 (1001-2000A)1.5 + 3

3.5 + 3 (1701-2000A)

2.0 + 4 (WIDE) 3.0 + 5 (Narrow)

5.0 +4 (WIDE, 100.1-200A)

5.0 + 5 (Narrow, 100.1-200A)

2.5 + 10 (WIDE) 1.0 + 5 (Narrow)

5.0% (WIDE, 350-400A)

2.0% (Narrow, 350-400A)

2.5 + 10 (WIDE) 1.0 + 5 (Narrow)

5.0% (WIDE, 350-400A)

2.0% (Narrow, 350-400A)

1.0 + 2 (WIDE, 200m/2/20A)

1.5 + 2 (Narrow, 200m/2/20A) 1.5 + 2 (WIDE,

200/0-500A@1000A) 2.0 + 2 (Narrow,

200/0-500A@1000A) 5% (WIDE, 501-1000A)

5.5% (Narrow, 501-1000A)

1.0 + 5 (3m/30m/30A, 0.05-50A @60A)

5.0 + 5 (50-60.6A@60A)

Filter OFF: 1.0 + 5 (3m/30m/30A,

0.05-50A @60A) 5.0 + 5

(50-60.6A@60A) Filter ON:

1.5 + 5 (3m/30m/30A, 0.05-50A @60A)

5.5 + 5 (50-60.6A@60A)

DCA --- --- --- --- --- 40/300A 400/1000A 400/2000A 400/2000A --- --- --- --- --- ---

Resolution --- --- --- --- --- 0.01A 0.1A 0.1A 0.1A --- v--- --- --- --- ---

Accuracy (% rdg + digit) --- --- --- ---

1.0 + 4 (40 A) 1.5 +4 (20-200 A

@300 A) 3.0% (200-300 A)

1.0 + 5 1.5 + 2 1.5 + 2 --- --- --- --- --- ---

ACV --- 200/600V 200/600V 40/400/750V 40/400/750V --- 40/400/600V 400/750V 40/400/750V --- --- --- --- --- ---

Accuracy @50/60Hz (% rdg + digit) --- 1.0 + 2 1.0 + 2 1.0 + 2 1.0 + 2 --- 1.5 + 5 1.5 + 2 1.5 + 3 --- --- --- --- --- ---

DCV --- --- --- 40/400/1000V 40/400/1000V --- 40/400/600V 400/1000V 40/400/1000V --- --- --- --- --- ---

Accuracy (% rdg + digit) --- --- --- 1.0 +2 1.0 +2 --- 1.0 + 5 1.0 + 2 1.0 + 2 --- --- --- --- --- ---

Resistance --- 200Ω 200Ω 400/4k/40k/400kΩ 400/4k/40k/400kΩ --- 400/4000Ω 400/4000Ω 400/4000Ω --- --- --- --- --- ---

Accuracy (% rdg + digit) --- 1.2 + 4 1.2 + 4 1.5 +2 1.5 +2 --- 1.0 + 5 1.5 + 2 1.5 + 2 --- --- --- --- --- ---

Continuity Buzzer --- YES YES YES YES --- YES YES YES --- --- --- --- --- ---

Frequency --- --- --- --- --- --- 10-3000Hz --- 10-3999 Hz --- --- --- --- --- ---

Accuracy (% rdg + digit) --- --- --- --- --- --- 1.5 + 5 --- 1.5 + 5 --- --- --- --- --- ---

Functions Data Hold YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES

Peak Hold --- --- --- YES YES --- YES YES YES --- YES YES YES

Analog Output --- --- ---DC 400mV

(for current)DC 400mV

(for current)--- ---

DC 400mV (for current)

DC 400mV (for current)

--- --- --- AC/DC 200mV --- ---

Frequency Filter --- --- --- --- --- --- --- --- --- YES YES YES YES --- YES

Other Sample Rate Approx. 2 times / secApprox. 2.5 times

/ secApprox. 2.5 times

/ secApprox. 2.5 times

/ secApprox. 2.5 times

/ secApprox. 2.5 times

/ secApprox. 3 times / sec

Approx. 2.5 times / sec

Approx. 3 times / sec Approx. 2 times / secApprox. 2.5 times

/ secApprox. 2.5 times

/ secApprox. 3 times / sec 2 times / sec 2 times / sec

Response Time Approx. 2 secondsApprox. 1 second

(2 seconds on resistance range)

Approx. 1 second (2 seconds on

resistance range)Approx. 2 seconds Approx. 2 seconds Approx. 2 seconds Approx. 2 seconds Approx. 2 seconds Approx. 2 seconds Approx. 2 seconds Approx. 2 seconds Approx. 2 seconds Approx. 1 second

Operating Temperature 0-40℃ -10-40℃ -10-40℃ 0-40℃ 0-40℃ 0-40℃ 0-40℃ 0-40℃ 0-40℃ 0-40℃ 0-40℃ 0-40℃ 0-40℃ 0-50℃ 0-50℃

Applicable Standard CAT. Ⅲ 300V CAT. Ⅲ 600V CAT. Ⅲ 600VCAT. Ⅲ 600VCAT. Ⅱ 1000V

CAT. Ⅳ 300V

CAT. Ⅲ 600VCAT. Ⅱ 1000V

CAT. Ⅲ 300V CAT. Ⅲ 600VCAT. Ⅳ 600VCAT. Ⅲ 1000V

CAT. Ⅲ 600VCAT. Ⅱ 1000V

CAT. Ⅲ 300V CAT. Ⅲ 300V CAT. Ⅲ 300V CAT. Ⅲ 300V CAT. Ⅲ 300V CAT. Ⅲ 300V

Battery Source LR-44 (or SR-44) x 2 9V 9V 2 x AA 2 x AA LR-44 (or SR-44) x 2 9V 2 x AA 9V LR-44 (or SR-44) x 2 2 x AAA 2 x AAA 9V CR2032 CR2032

Battery Life (Continuous Operation) Approx. 100 hrs Approx. 200 hrs Approx. 200 hrs Approx. 150 hrs Approx. 80 hrs Approx. 11 hrs Approx. 15 hrs Approx. 100 hrs Approx. 15 hrs Approx. 15 hrs Approx. 40 hrs Approx. 24 hrs Approx. 60 hrs Approx. 90 hrs Approx. 90hrs

Dimensions (W)x(H)x(D)mm 59 x 148 x 26 91 x 208 x 40 91 x 208 x 40 105 x 247 x 49 105 x 247 x 49 59 x 147 x 25 91 x 210 x 40 105 x 250 x 49 105 x 250 x 49 60 x 149 x 26 81 x 185 x 40 81 x 185 x 32 129 x 248 x 55 70 x 178 x 25 70 x 178 x 25

Weight (Approx.) 100g 400g 400g 470g 470g 100g 450g 530g 540g 120g 270g 270g 570g 200g 200g

Warranty 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year

Detection Method

Frequency Characteristics

Conductor Size (MAX. mm)

Clamp-On Meter Selector Guide

www.yokogawa-usa.com