Page 1: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

78-4028088-01 Rev B

Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide

Page 2: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user
Page 3: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

For Your Safety

Explanation of Warning and Caution Icons Avoid personal injury and product damage! Do not proceed beyond any symbol until you fully understand the indicated conditions.

The following warning and caution icons alert you to important information about the safe operation of this product:

You may find this symbol in the document that accompanies this product. This symbol indicates important operating or maintenance instructions.

You may find this symbol affixed to the product. This symbol indicates a live terminal where a dangerous voltage may be present; the tip of the flash points to the terminal device.

You may find this symbol affixed to the product. This symbol indicates a protective ground terminal.

You may find this symbol affixed to the product. This symbol indicates a chassis terminal (normally used for equipotential bonding).

You may find this symbol affixed to the product. This symbol warns of a potentially hot surface.

You may find this symbol affixed to the product and in this document. This symbol indicates an infrared laser that transmits intensity-modulated light and emits invisible laser radiation or an LED that transmits intensity-modulated light.

Important Please read this entire guide. If this guide provides installation or operation instructions, give particular attention to all safety statements included in this guide.

Page 4: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Notices

Trademark Acknowledgments Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of cisco trademarks, go to this URL: www.cisco.com/go/trademarks.

Third party trademarks mentioned are the property of their respective owners.

The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1110R)

Publication Disclaimer Cisco Systems, Inc. assumes no responsibility for errors or omissions that may appear in this publication. We reserve the right to change this publication at any time without notice. This document is not to be construed as conferring by implication, estoppel, or otherwise any license or right under any copyright or patent, whether or not the use of any information in this document employs an invention claimed in any existing or later issued patent.

Copyright © 2009, 2012 Cisco and/or its affiliates. All rights reserved. Printed in the United States of America.

Information in this publication is subject to change without notice. No part of this publication may be reproduced or transmitted in any form, by photocopy, microfilm, xerography, or any other means, or incorporated into any information retrieval system, electronic or mechanical, for any purpose, without the express permission of Cisco Systems, Inc.

Page 5: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

78-4028088-01 Rev B iii

Contents

Safe Operation for Software Controlling Optical Transmission Equipment v

Chapter 1 Introduction 1

Chapter 2 Installation 3

Utility Setup .............................................................................................................................. 4 Minimum Requirements ............................................................................................ 4 SNMP Setup ................................................................................................................. 4 Initial Setup .................................................................................................................. 7

Chapter 3 Operating the Lumin Chassis and Modules Using the Lumin Utility 11

Connecting via Serial Port (DLC) ........................................................................................ 12 Chassis Details ........................................................................................................... 12 Module Details .......................................................................................................... 14 DLT Transmitter Module Control .......................................................................... 16 DDR Receiver Module Control ............................................................................... 17 Assigning Names ...................................................................................................... 18 Assigning IP Address ............................................................................................... 19

Connecting via Ethernet Port ............................................................................................... 21 Chassis Details ........................................................................................................... 21 Module Details .......................................................................................................... 24 DLT Transmitter Module Control .......................................................................... 26 DDR Receiver Module Control ............................................................................... 28 Assigning Names ...................................................................................................... 29

Network Alarm Notification ................................................................................................ 31 Service Mode .......................................................................................................................... 32

Assigning IP Address ............................................................................................... 32

Chapter 4 SNMP Management 35

Introduction ............................................................................................................................ 36 Accessing via SNMP .............................................................................................................. 37 Standard Lumin MIBS ........................................................................................................... 38

Lumin MIB Contents ................................................................................................ 38 Viewing the Lumin MIB .......................................................................................... 38

Page 6: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Contents

iv 78-4028088-01 Rev B

stdChassisInfo Elements .......................................................................................... 40 stdModule Elements ................................................................................................. 43 modDLTTable Elements .......................................................................................... 43 modDDRTable Elements ......................................................................................... 46

Alarm Info MIB ...................................................................................................................... 48 Trap Description .................................................................................................................... 49 Caveats .................................................................................................................................... 50 Frequently Asked Questions ................................................................................................ 51

Chapter 5 Customer Support Information 52

Glossary 53

Index 57

Page 7: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Safe Operation for Software Controlling Optical Transmission Equipment

78-4028088-01 Rev B v

Safe Operation for Software Controlling Optical Transmission Equipment

If this manual discusses software, the software described is used to monitor and/or control ours and other vendors’ electrical and optical equipment designed to transmit video, voice, or data signals. Certain safety precautions must be observed when operating equipment of this nature.

For equipment specific safety requirements, refer to the appropriate section of the equipment documentation.

For safe operation of this software, refer to the following warnings.

WARNING:

Ensure that all optical connections are complete or terminated before using this equipment to remotely control a laser device. An optical or laser device can pose a hazard to remotely located personnel when operated without their knowledge.

Allow only personnel trained in laser safety to operate this software. Otherwise, injuries to personnel may occur.

Restrict access of this software to authorized personnel only.

Install this software in equipment that is located in a restricted access area.

Page 8: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user
Page 9: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

78-4028088-01 Rev B 1

Overview This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user to control the Lumin chassis via a serial port (RS-232) or local area network using Simple Network Management Protocol (SNMP). The user can install the software and immediately control a chassis without a Management Information Base (MIB) table.

Who Should Use This Document This document is intended for authorized service personnel who have experience working with similar equipment. The service personnel should have appropriate background and knowledge to complete the procedures described in this document.

Qualified Personnel Only appropriately qualified and skilled service personnel should attempt to install, operate, maintain, and service this product.

WARNING:

Allow only qualified and skilled personnel to install, operate, maintain, and service this product. Otherwise, personal injury or equipment damage may occur.

Document Version This is the second release of this guide.

1 Chapter 1 Introduction

Page 10: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user
Page 11: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

78-4028088-01 Rev B 3

This chapter provides instructions for configuring your system to work with the Cisco Lumin Utility.

2 Chapter 2 Installation

In This Chapter Utility Setup ............................................................................................. 4

Page 12: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 2 Installation

4 78-4028088-01 Rev B

Utility Setup

Minimum Requirements Operating System Windows NT, 2000, or XP

Personal Computer Pentium III (minimum)

RAM 256 MB

SNMP Setup The Simple Network Management Protocol (SNMP) service on your PC must be enabled under Windows in order for the utility to work correctly. SNMP service is NOT typically installed during Windows installation.

To Install SNMP for the PC 1 Click start, Control Panel.

Result: The Control Panel window appears.

Page 13: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Utility Setup

78-4028088-01 Rev B 5

2 Double-click Add or Remove Programs. Result: The Add or Remove Programs window appears.

3 In the left window, click Add/Remove Windows Components.

Result: The Windows Components Wizard window appears.

4 Scroll the list and select Management and Monitoring Tools. 5 Click the Details button.

Page 14: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 2 Installation

6 78-4028088-01 Rev B

Result: The Management and Monitoring Tools window appears.

6 Scroll the list and select a protocol. 7 Click OK.

Result: The Windows Components Wizard window appears. 8 Click Next.

Result: The Configuring Components window appears.

9 Insert the appropriate disk and follow Windows instructions to complete the

installation.

Page 15: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Utility Setup

78-4028088-01 Rev B 7

To Pass SNMP Traps for XP 1 In the Control Panel window, double-click Windows Firewall. 2 Click the Exceptions tab, and then click the Add Port button. 3 In the Add Port window, select the UDP option. 4 Enter SNMP Trap for Name and 162 for Port Number. 5 Select OK.

Initial Setup The Cisco Lumin Utility uses either the RS-232 communication port or the Ethernet port to control devices.

The following instructions provide information on setting up the ports.

After installing and running the utility, the following screen appears.

RS-232 Connection Follow the instructions below to connect via RS-232. 1 From the Config menu, select COM PORT CONFIG and select the correct

communication port. 2 From the Connect menu, select Serial to make a serial connection. 3 From the Select Unit Type menu, select Lumin if the serial cable is connected to

a DLC device. Note: Do not select Lumin Lite.

Page 16: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 2 Installation

8 78-4028088-01 Rev B

Ethernet Connection Follow the instructions below to connect via Ethernet. 1 From the Connect menu, select Ethernet. 2 From the Config menu, select IP Config to view network configuration fields.

Result: The following screen appears.

3 Enter the System Subnet and Subnet Mask.

Note: It is recommended that the computer be in the same system subnet as the Lumin devices.

4 Click OK. Note: When changing from DHCP On to DHCP Off, or Serial to Ethernet, the fan tray must be re-initialized. Loosen the two thumb screws on the fan tray and pull the tray out a few inches to remove power. Wait 5 seconds, then re-insert and tighten screws.

CAUTION:

Operating the chassis with the fan tray removed for more than a few minutes will result in overheating and should be avoided.

In Ethernet mode, the fan tray and Digi (Ethernet) firmware versions are concatenated in the display. The image below shows how to interpret the concatenation.

Page 17: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Utility Setup

78-4028088-01 Rev B 9

Help Menu Follow the instructions below to access the Help menu. 1 From the Help menu, select Lumin Utility Help.

Note: The file is in PDF format and requires Adobe Acrobat Reader, version 4 or higher.

Page 18: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user
Page 19: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

78-4028088-01 Rev B 11

The Lumin Utility allows you to operate and monitor the chassis using the Serial port or the Ethernet port.

3 Chapter 3 Operating the Lumin Chassis and Modules Using the Lumin Utility

In This Chapter Connecting via Serial Port (DLC) ....................................................... 12 Connecting via Ethernet Port .............................................................. 21 Network Alarm Notification ............................................................... 31 Service Mode ......................................................................................... 32

Page 20: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 3 Operating the Lumin Chassis and Modules Using the Lumin Utility

12 78-4028088-01 Rev B

Connecting via Serial Port (DLC) The following section provides instructions for operating the chassis and modules via a serial port connection.

Chassis Details Follow the instructions below to view details of the chassis. 1 From the Connect menu, select Serial. 2 Click Unit Info Table 1 to view model and alarm status.

Result: The following screen appears.

3 Click Unit Info Table 2 to view serial number and firmware version.

Page 21: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Connecting via Serial Port (DLC)

78-4028088-01 Rev B 13

Result: The following screen appears.

4 Click the Lumin node from the tree view (left window) to monitor fan tray

controller (FTC) and power supply parameters. Result: The following screen appears.

5 In the POWER MONITOR window, select Main Power Supply and/or Aux

Power Supply. To return to the original display, click the X box in the upper right corner of the internal display. Note: Save Unit Settings/Parameters and Restore Unit Settings/Parameters will be supported later.

Page 22: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 3 Operating the Lumin Chassis and Modules Using the Lumin Utility

14 78-4028088-01 Rev B

Module Details Follow the instructions below to view details of the modules. 1 Click the Slot Discovery button to view the slot overview screen.

Result: The following screen appears.

2 Click Unit Info Table 2 to view the serial number and firmware version for each

module. Result: The following screen appears.

Page 23: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Connecting via Serial Port (DLC)

78-4028088-01 Rev B 15

3 Click View Event Log to view a log of events. Result: The following screen appears.

The events are logged in the following format:

Unit number/location

Date and time stamp

Event description (including status) Note: The last event is logged as the first entry on the list.

Page 24: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 3 Operating the Lumin Chassis and Modules Using the Lumin Utility

16 78-4028088-01 Rev B

DLT Transmitter Module Control Follow the instructions below to set DLT module parameters using the serial port. 1 Click the DLT module icon from the tree view to view or set parameters.

Result: The following screen appears.

Note: The hand icon shows which module is currently displayed. The following parameters can be changed.

Laser Drive - change the laser value (0 to 5 dB). Press Enter on the keyboard to set the parameter.

Laser Enable - enable/disable laser. Click On or Off.

AGC Enable - enable/disable AGC. Click On or Off.

Note:

The Alarm window shows current alarm status.

Restore Factory Defaults will be supported later.

Page 25: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Connecting via Serial Port (DLC)

78-4028088-01 Rev B 17

DDR Receiver Module Control Follow the instructions below to set DDR module parameters. 1 Click the DDR module icon from the tree view.

Result: The following screen appears.

The following parameters can be changed.

Attenuator A - change the value (0 to 32 dB). Press Enter on the keyboard to set the parameter.

Attenuator B - change the value (0 to 32 dB). Press Enter on the keyboard to set the parameter.

Note:

- The Alarm window shows current alarm status.

- Disable Alarms and Restore Factory Defaults will be supported later.

Page 26: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 3 Operating the Lumin Chassis and Modules Using the Lumin Utility

18 78-4028088-01 Rev B

Assigning Names Names can be assigned for the chassis and slots. Follow the instructions below to assign names.

Note: Names are assigned to actual chassis slots and stored in fan tray memory. The name is not written to a module. 1 From the main menu, select Assign Slots Name.

Result: The following screen appears.

Page 27: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Connecting via Serial Port (DLC)

78-4028088-01 Rev B 19

2 Select the desired slot from the Chassis column and then click the corresponding row from the Name column to change the chassis slot name.

3 Press Enter on the keyboard to confirm the change. Important: Do not just click another line. You must press Enter or the change will be lost.

4 Click Save To File to store the name in a file on your PC. 5 Click Update From File to update the name from a file on your PC. 6 Click OK to load new slot names. 7 Click Clear to clear all slot names. 8 Click the X in the upper right corner to exit the screen.

Assigning IP Address Follow the instructions below to assign an IP address. 1 From the main menu, select the Assign IP Address menu.

Result: The following screen appears.

2 To set the static IP address, uncheck the DHCP box. 3 Enter the IP Address, Subnet Mask and Gateway in the appropriate field. 4 Check the communication settings using the front panel controls and display.

The port should be ethernet with DHCP off.

Page 28: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 3 Operating the Lumin Chassis and Modules Using the Lumin Utility

20 78-4028088-01 Rev B

5 Click Write Unit IP Address. Notes:

When changing from DHCP On to DHCP Off, or Serial to Ethernet, the fan tray must be re-initialized. Loosen the two thumb screws on the fan tray and pull the tray out a few inches to remove power. Wait 5 seconds, then re-insert and tighten screws.

Read Unit IP Address will be supported later.

CAUTION:

Operating the chassis with the fan tray removed for more than a few minutes will result in overheating and should be avoided.

Page 29: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Connecting via Ethernet Port

78-4028088-01 Rev B 21

Connecting via Ethernet Port The following section provides instructions for operating the chassis and modules via an Ethernet connection.

Chassis Details Follow the instructions below to view details of the chassis. 1 From the Connect menu, select Ethernet.

Result: The following screen appears.

2 To query more than one unit, enter the IP address range (001 - 254) for your

system in the Start and End fields. Note: This range is for the last octet in the IP address.

3 To query a single unit, enter the same IP address in the Start and End fields. 4 Click the Query Network button.

Page 30: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 3 Operating the Lumin Chassis and Modules Using the Lumin Utility

22 78-4028088-01 Rev B

Result: The following screen appears.

Note: When changing from DHCP On to DHCP Off, or Serial to Ethernet, the fan tray must be re-initialized. Loosen the two thumb screws on the fan tray and pull the tray out a few inches to remove power. Wait 5 seconds, then re-insert and tighten screws.

CAUTION:

Operating the chassis with the fan tray removed for more than a few minutes will result in overheating and should be avoided.

The left pane shows the addresses in sequential order and in a tree/node format.

The right pane has the following three folder tabs.

Unit Info Table 1 - Unit ID, Unit Name, Serial Number, Alarm Status

Unit Info Table 2 - Unit ID, FW Version, MAC Address, Unit Uptime

View Event Log - Alarms, Slot Installation/Removal, lost and establish connection, etc.

1 Click Unit Info Table 2 to view Unit ID, firmware version, MAC Address, and Unit Uptime for each module.

Page 31: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Connecting via Ethernet Port

78-4028088-01 Rev B 23

Result: The following screen appears.

2 Click the chassis icon from the tree view (do not click the + sign) to monitor the

fan tray controller and power supply parameters. Result: The following screen appears.

3 In the POWER MONITOR window, check Main Power Supply and/or Aux

Power Supply. 4 To return to the original display, click the X box near the upper right corner of

the internal display. Note: Save Unit Settings/Parameters and Restore Unit Settings/Parameters will be supported later.

Page 32: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 3 Operating the Lumin Chassis and Modules Using the Lumin Utility

24 78-4028088-01 Rev B

5 Click the + sign next to the chassis icon to expand the node tree and view the module information. Result: The following screen appears (if Unit Info Table 1 selected).

Module Details Follow the instructions below to view details of the modules. 1 Click the + sign next to the chassis icon to expand the node tree and view the

module information.

Page 33: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Connecting via Ethernet Port

78-4028088-01 Rev B 25

Result: The following screen appears.

2 Click Unit Info Table 2 to view the serial number and firmware version for each

module. Result: The following screen appears.

Page 34: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 3 Operating the Lumin Chassis and Modules Using the Lumin Utility

26 78-4028088-01 Rev B

3 Click View Event Log to view a log of events. 4 Result: The following screen appears.

The events are logged in the following format:

Unit number/location

Date and time stamp

Event description (including status)

Note: The last event is logged as the first entry on the list.

DLT Transmitter Module Control Follow the instructions below to set DLT module parameters for the Ethernet port. 1 Click the DLT module icon from the tree view to view and/or set parameters.

Result: The following screen appears.

Page 35: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Connecting via Ethernet Port

78-4028088-01 Rev B 27

Note: The hand icon shows which module is currently displayed.

The following parameters can be changed.

Laser Drive - change the value (0 to 5 dB). Press Enter on the keyboard to set the parameter.

Laser Enable - enable/disable laser. Click On or Off.

AGC Enable - enable/disable AGC. Click On or Off.

Notes:

- The Alarm window shows current alarm status.

- Restore Factory Defaults will be supported later.

Page 36: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 3 Operating the Lumin Chassis and Modules Using the Lumin Utility

28 78-4028088-01 Rev B

DDR Receiver Module Control Follow the instructions below to set DDR module parameters for the Ethernet port. 1 Click the DDR module icon from the tree view to view or set DDR module

parameters. Result: The following screen appears.

The following parameters can be changed.

Attenuator A - change the value (0 to 32 dB). Press Enter on the keyboard to set the parameter.

Attenuator B - change the value ( 0 to 32 dB). Press Enter on the keyboard to set the parameter.

Note:

- The Alarm window shows current alarm status.

- Disable Alarms and Restore Factory Defaults will be supported later.

Page 37: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Connecting via Ethernet Port

78-4028088-01 Rev B 29

Assigning Names Names can be assigned for the chassis and slots. Follow the instructions below to assign names.

Note: Names are assigned to actual chassis slots and stored in fan tray memory. The name is not written to a module. 1 From the main menu, select Assign Slots Name.

Result: The following screen appears.

Page 38: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 3 Operating the Lumin Chassis and Modules Using the Lumin Utility

30 78-4028088-01 Rev B

2 Select the desired slot from the Chassis column and then click the corresponding row from the Name column to change the chassis slot name.

3 Press Enter on the keyboard to confirm the change. Important: Do not just click another line. You must press Enter or the change will be lost.

4 Click Save To File to store the name in a file on your PC. 5 Click Update From File to update the name from a file on your PC. 6 Click OK to load new slot names in the fan tray. 7 Click Clear to clear all slot names from the fan tray. 8 Click the X in the upper right hand corner to exit the screen.

Page 39: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Network Alarm Notification

78-4028088-01 Rev B 31

Network Alarm Notification While monitoring a unit, you will be prompted for any alarmed Lumin unit in the network.

1 Press the alarm button to view the list of alarmed units.

2 Select the entry from the list to switch from the current expanded node tree to

the new chassis and alarm.

Page 40: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 3 Operating the Lumin Chassis and Modules Using the Lumin Utility

32 78-4028088-01 Rev B

Service Mode This mode can be used to assign the IP address. 1 From the Tools menu, select Service Mode.

Assigning IP Address 1 From the Tools menu, select Assign IP Address.

Result: The following screen appears. Important Note: To assign an IP address while in Ethernet mode, you must be running on a server.

2 Click Build Network Table.

Page 41: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Service Mode

78-4028088-01 Rev B 33

Result: The following screen appears.

3 Click Status for the unit to which you want to assign a new IP address. 4 Change the status, and then click the IP Address field.

Result: The following screen appears.

5 Replace current IP address with the network available IP address. 6 Click OK.

Note: If the IP address is not available, you will be prompted to change the IP address.

Page 42: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 3 Operating the Lumin Chassis and Modules Using the Lumin Utility

34 78-4028088-01 Rev B

Note: When changing from DHCP On to DHCP Off, or Serial to Ethernet, the fan tray must be re-initialized. Loosen the two thumb screws on the fan tray and pull the tray out a few inches to remove power. Wait 5 seconds, then re-insert and tighten screws.

CAUTION:

Operating the chassis with the fan tray removed for more than a few minutes will result in overheating and should be avoided.

Page 43: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

78-4028088-01 Rev B 35

Overview This chapter provides information about using SNMP commands for remote system monitoring and control. Lumin uses SNMP v2c commands and sends SNMP v2c traps and notifications.

4 Chapter 4 SNMP Management

In This Chapter Introduction ........................................................................................... 36 Accessing via SNMP ............................................................................. 37 Standard Lumin MIBS .......................................................................... 38 Alarm Info MIB ..................................................................................... 48 Trap Description ................................................................................... 49 Caveats ................................................................................................... 50 Frequently Asked Questions ............................................................... 51

Page 44: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 4 SNMP Management

36 78-4028088-01 Rev B

Introduction SNMP is an International Organization for Standardization (ISO) often used by network and element management systems to monitor network devices for alarms and other significant conditions.

SNMP accesses information about network devices through Management Information Base (MIB) objects. MIBs are hierarchical tree-structured descriptions used to define database elements. SNMP is used to manage individual data elements and the values assigned to MIB objects.

SNMP addresses a single MIB object using a numeric string called an object identifier (OID). The OID defines a branching path through the hierarchy to the location of the object. In addition to the OID, a MIB object is known by its object descriptor, a text string intended to be more meaningful to a human operator. The OID and object descriptor are unique to each MIB object.

Also defined for each MIB object is the access that SNMP affords the object data value. For example, if a MIB object has read-write access, SNMP can be used to retrieve and set the value of the object. If an object is read-only, SNMP can be used to get the object value, but not change it.

Page 45: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Accessing via SNMP

78-4028088-01 Rev B 37

Accessing via SNMP The Lumin DLC has an Ethernet port on the front. Use a standard RJ-45 cable to connect to your network. Your MIB browser (for example, MG-Soft MIB browser or Castle Rock SNMPc) should be set to use SNMP v2c with a read community string of "public" and a write community string of "private". To get full access via SNMP, change the port on the front display from RS-232 to Ethernet. The access will be read-only if not changed.

Important: SNMP v1 is not supported. You must use SNMP v2c. If using the sysName.0 management object (1.3.6.1.2.1.1.5.0) to identify a Lumin chassis, the object will return "Lumin".

Page 46: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 4 SNMP Management

38 78-4028088-01 Rev B

Standard Lumin MIBS The Lumin MIBs allow easy access to the chassis, trap, alarm and module information via SNMP. There is one proprietary MIB for management and event notification.

The StandardComm-Lumin-MIB contains a scalar list of values used to control Lumin management functions as well as several tables covering the modules and alarms.

This MIB depends on the Standard-Communications-Global-MIB but only for placement in the OID tree. Details of the elements are provided in the following sections. Only the Lumin sub-tree is covered here.

Lumin MIB Contents MIB objects fall into several categories. Parameters for the chassis include the state of the chassis in terms of power supplies, voltages, and network settings. Other tables cover module-specific settings and alarms.

Viewing the Lumin MIB To view the Lumin MIB, compile and load both Standard-Communications-Global-MIB and Lumin-MIB in your MIB browser.

The Lumin-MIB OID is 1.3.6.1.4.1.8273.4. This is the dot version of the full path that expands to: iso(1).org(3).dod(6).internet(1).private(4).enterprises(1). standardcommunications(8273).stdLuminMib(4)

This MIB contains stdChassisInfo (entire chassis), stdModuleInfo, stdAlarm Info and stdAlarmEvent (trap/notification). The following is a typical screen for the stdChassisInfo.

Page 47: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Standard Lumin MIBS

78-4028088-01 Rev B 39

Some objects are enumerated values (stdChassisType.0) and strings (trapDest0.0, which shows an IP address). Others are scaled integers (stdPlus24Volts.0, which shows 242, indicating 24.2 volts).

The stdModuleInfo contains several tables including an overall inventory and status table, stdModuleTable, which gives a quick summary of the module population and alarm status.

DLT specific information can be found in the modDLTTable.

Page 48: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 4 SNMP Management

40 78-4028088-01 Rev B

DDR specific information can be found in the modDDRTable.

stdChassisInfo Elements The stdChassisInfo MIB contains the following elements.

Element Example Value Description stdChassisType.0 stdDLC(1) Values: stdDLC(1), stdDLL(2)

Access: read-only

OID: 1.3.6.1.4.1.8273.4.1.1 Displays type of chassis being controlled. MIB works with both the DLC (up to 15 modules and the DLL (up to 3 modules).

stdFirmwareVersion.0 2.07.23 Access: read-only

OID: 1.3.6.1.4.1.8273.4.1.2

Displays firmware version number:

2.03 = firmware version for the fan tray (DFT)

.18 = version of the Ethernet (Digi) module

stdSerialNumber.0 YYMMMSSS Access: read-only

OID: 1.3.6.1.4.1.8273.4.1.3

Displays serial number.

stdModelNumber.0 DFT Access: read-only

OID: 1.3.6.1.4.1.8273.4.1.4

Displays fan tray model number.

stdChassisAlarms.0 OK Access: read-only

OID: 1.3.6.1.4.1.8273.4.1.5 View current alarms in text format. If there are no active alarms, this leaf returns "OK".

Page 49: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Standard Lumin MIBS

78-4028088-01 Rev B 41

Element Example Value Description stdSystemError.0 on(1) Values: on(1), off(2)

Access: read-only

OID: 1.3.6.1.4.1.8273.4.1.6

Displays chassis alarm/fault condition:

On = alarm/fault

Off = no alarm/fault

stdCommState.0 statusOK(48) Values: statusOK(48), statusFault(96)

Access: read-only

OID: 1.3.6.1.4.1.8273.4.1.7

Displays communication status:

Status OK (48) = communication to host allowed

Status Fault (96) = no set command allowed

stdFanStatus.0 on(1) Values: on(1), off(2)

Access: read-only

OID: 1.3.6.1.4.1.8273.4.1.8

Displays status of the system fans:

Off = problem with the fans.

stdChassisTemp.0 21 Access: read-only

OID: 1.3.6.1.4.1.8273.4.1.9

Displays fan tray temperature in degree celsius.

stdPlus5Volts.0 54 Access: read-only

OID: 1.3.6.1.4.1.8273.4.1.10 Displays current reading for the +5 V DC located on the fan tray. The value is in tenths of a volt.

Ex: 54 = 5.4 volts.

stdMinus5Volts.0 53 Access: read-only

OID: 1.3.6.1.4.1.8273.4.1.11 Displays current absolute value reading for the -5 V DC located on the fan tray. The value is in tenths of a volt.

Ex: 53 = -5.3 volts.

stdPlus24Volts.0 242 Access: read-only

OID: 1.3.6.1.4.1.8273.4.1.12

Displays current reading for the 24 V DC located on the fan tray. The value is in tenths of a volt.

Ex: 242 = 24.2 volts.

Page 50: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 4 SNMP Management

42 78-4028088-01 Rev B

Element Example Value Description stdMainPSStatus.0 on(1) Values: on(1), off(2)

Access: read-only

OID: 1.3.6.1.4.1.8273.4.1.13

Displays the status of the main power supply:

On(1) = Ok

Off(2) = main power supply failed

stdAuxPSStatus.0 off(2) Values: on(1), off(2)

Access: read-only

OID: 1.3.6.1.4.1.8273.4.1.14

Displays the status of any Aux. power supply:

On(1) = Aux power supply running

Off(2) = problem with Aux power supply

stdPwrMonitor.0 mainOnly(1) Values: none(0), mainOnly(1), auxOnly(2), both(3)

Access: read-write

OID: 1.3.6.1.4.1.8273.4.1.15

Controls what power supply will be monitored.

trapDest0.0 10.91.38.20 Access: read-write

OID: 1.3.6.1.4.1.8273.4.1.16 Fully qualified IP address for where to send the stdAlarmEvent traps, position 1 of 5. Format is in standard dotted notation: 1.2.3.4.

trapDest1.0 10.91.38.27 Access: read-write

OID: 1.3.6.1.4.1.8273.4.1.17 Fully qualified IP address for where to send the stdAlarmEvent traps, position 2 of 5. Format is in standard dotted notation: 1.2.3.4.

trapDest2.0 0.0.0.0 (empty) Access: read-write

OID: 1.3.6.1.4.1.8273.4.1.18 Fully qualified IP address for where to send the stdAlarmEvent traps, position 3 of 5. Format is in standard dotted notation: 1.2.3.4.

trapDest3.0 0.0.0.0 (empty) Access: read-write

OID: 1.3.6.1.4.1.8273.4.1.19 Fully qualified IP address for where to send the stdAlarmEvent traps, position 4 of 5. Format is in standard dotted notation: 1.2.3.4.

trapDest4.0 0.0.0.0 (empty) Access: read-write

OID: 1.3.6.1.4.1.8273.4.1.20 Fully qualified IP address for where to send the stdAlarmEvent traps, position 5 of 5. Format is in standard dotted notation: 1.2.3.4.

Page 51: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Standard Lumin MIBS

78-4028088-01 Rev B 43

stdModule Elements The standard module table gives a quick summary of how the chassis is populated and if there are any active alarms.

Element Example Value Description modType ddr(32) empty(1), dlt(8), dfr(16), ddr(32), dsa(64), dltInBoot(136), dfrInBoot(144),

ddrInBoot(160), dsaInBoot(192), unknownInBoot(128), unknown(255)

Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.1.1.2 Provides the type of module for this slot. If the module is in boot, no valid runtime code is available on that unit. The unit should be returned to the factory.

modName My Lumin DDR Access: read-write

OID: 1.3.6.1.4.1.8273.4.2.1.1.3

Displays or sets the slot name.

modAlarm off(2) on(1), off(2)

Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.1.1.4

Displays alarm status:

On = alarm

Off = modules Ok

modDLTTable Elements The DLT table lists all the DLT modules and details about each.

Element Example Value Description modDLTFirmware 3.36 Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.1.1.1.1 Displays firmware version for the optical transmitter module.

modDLTSerialNumber AAVUXYZ Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.1.1.1.2

Displays the module serial number.

modDLTModelNumber DLT-7 Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.1.1.1.3

Displays model number for the transmitter module.

modDLTAlarms RF Input Low, RF Input Alarm

Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.1.1.1.4 View current alarms in text format. If there are no active alarms, this leaf returns "OK".

Page 52: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 4 SNMP Management

44 78-4028088-01 Rev B

Element Example Value Description modDLTModuleTemp 198 Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.1.1.1.5

View current transmitter temperature reading in tenths of a degree celsius.

Ex: 198 = 19.8C

modDLTLaserBiasCur 458 Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.1.1.1.6 View laser bias current reading in tenths of a milliampere.

Ex: 458=45.8mA

modDLTOutputPower 71 Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.1.1.1.7 View current output power reading in tenths of a dBm.

Ex: 71 = 7.1 dBm

modDLTRFInDAC 894 Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.1.1.1.8 View the average RF power in value. It is a unitless number, where the greater the number, the higher the value.

modDLTLaserTemp 160 Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.1.1.1.9 Displays laser temperature in tenths of a degree celsius.

Ex: 160 =16.0C

modDLTRFPadLevel 30 Access: read-write

OID: 1.3.6.1.4.1.8273.4.2.2.1.1.1.10 Control pad level for the input RF signal in tenths of a dB.

Ex: 30 = 3.0 dB

modDLTLaserEnable on(1) Values: on(1), off(2)

Access: read-write

OID: 1.3.6.1.4.1.8273.4.2.2.1.1.1.11

Enable/disable the transmitter laser.

modDLTAGCEnable off(2) Values: on(1), off(2)

Access: read-write

OID: 1.3.6.1.4.1.8273.4.2.2.1.1.1.12

Enable/disable AGC.

Page 53: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Standard Lumin MIBS

78-4028088-01 Rev B 45

Element Example Value Description modDLTSetDefaults off(2) Values: on(1), off(2)

Access: read-write

OID: 1.3.6.1.4.1.8273.4.2.2.1.1.1.13 When set to on(1), it forces the module to return to factory defaults.

Page 54: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 4 SNMP Management

46 78-4028088-01 Rev B

modDDRTable Elements The DDR table lists all the DDR modules and details about each.

Element Example Value

Description

modDDRFirmware 3.07 Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.2.1.1.1 Displays firmware version for the dual receiver module.

modDDRSerialNumber AAGSNUU Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.2.1.1.2

Displays module serial number.

modDDRModelNumber DDR Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.2.1.1.3 Displays model number for the dual receiver module.

modDDRAlarms OK Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.2.1.1.4 View current alarms in text format. If there are no active alarms, this element returns "OK".

modDDRModuleTemp 303 Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.2.1.1.5 Displays the module temperature in tenths of a degree celsius.

Ex: 303 = 30.3C

modDDRInputAPwr -200 Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.2.1.1.6 View current input power reading for channel A in tenths of dBm.

Ex: -200 = -20.0 dBm

modDDRInputBPwr -200 Access: read-only

OID: 1.3.6.1.4.1.8273.4.2.2.2.1.1.7 View current input power reading for channel B in tenths of dBm.

Ex: -200 = -20.0 dBm

modDDRDeviceMask maskNone(0) Values: maskNone(0), maskA(1), maskB(2), maskBoth(8)

Access: read-write

OID: 1.3.6.1.4.1.8273.4.2.2.2.1.1.8 Sets the monitoring mask for internal devices. Controls the alarms on the devices.

Page 55: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Standard Lumin MIBS

78-4028088-01 Rev B 47

Element Example Value

Description

modDDRRFPadLevelA 200 Access: read-write

OID: 1.3.6.1.4.1.8273.4.2.2.2.1.1.9 Displays or sets pad level for laser A in tenths of a dB.

Ex: 200 = 20.0 dB

modDDRRFPadLevelB 200 Access: read-write

OID: 1.3.6.1.4.1.8273.4.2.2.2.1.1.10 Displays or sets pad level for laser B in tenths of a dB.

Ex: 200 = 20.0 dB

modDDRSetDefaults 2 Values: on(1), off(2)

Access: read-write

OID: 1.3.6.1.4.1.8273.4.2.2.2.1.1.11 When set to (1), it forces the module to return to factory defaults.

Page 56: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 4 SNMP Management

48 78-4028088-01 Rev B

Alarm Info MIB Alarms are recorded using a human-readable table that is patterned after the HMS MIB alarmIdent (OID: 1.3.6.1.4.1.5591.1.2). When conducting a MIB walk, the alarmIdent branch is listed, however, this is not intended for customer use and does not follow the normal patterns defined in the HMS MIB. The following screen shows the MIB that should be used.

During operations, the stdAlarmEvent and the hmsAlarmEvent are sent. Disregard the hmsAlarmEvent as it is used for internal communications with the Lumin Utility and is not intended for customer use. All relevant information can be found in the stdAlarmEvent and the stdAlarmTable.

Page 57: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Trap Description

78-4028088-01 Rev B 49

Trap Description When an entry is put into the stdAlarmTable, there is a corresponding stdAlarmEvent trap. A standard coldStart trap is also sent upon boot of the fan tray. Each of the destinations listed in trapDest0.0 - trapDest4.0 (refer to stdChassisInfo Elements (on page 40)) will receive the trap without having to be in the same subnet. A broadcast trap is also sent (limited to the same subnet as the Cisco Lumin chassis). The following screen shows a typical trap/notification.

Note: This is an SNMP v2c notification and not an SNMP v1 trap.

Page 58: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 4 SNMP Management

50 78-4028088-01 Rev B

Caveats Only SNMP v2c is supported. Normally an SNMP v2c agent would be

backwards compatible with SNMP v1, but not this one. Community strings are "public" for read access, and "private" for write access.

The timestamps stored in the stdAlarmTable are relative to the time the chassis was powered. Use the corresponding trap's received timestamp to track an event.

Page 59: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Frequently Asked Questions

78-4028088-01 Rev B 51

Frequently Asked Questions 1 Why doesn't my MIB Browser work with the Cisco Lumin chassis?

a Make sure you have configured for SNMP v2c with a read community string of "public" and a write community string of "private". SNMP v1 does not work with the Lumin chassis.

b Several minutes are required after applying power for the LuminNet component to initialize and synchronize with the fan tray.

2 How do I send traps to a particular IP address? a Modify the list of trap destinations (trapDest0-4) by hand (recommended) or b If you have a MIB browser on the PC that you want to get the trap, perform

a GET on the management object sysUpTime. This updates a hidden dynamic list of "interested" managers.

3 What are DFR and DSA modules shown in the stdModuleTypes tree? a These are legacy modules no longer supported.

4 Can I change the IP address via SNMP? a No. This must be done via the Lumin Utility or front panel.

Page 60: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Chapter 5 Customer Support Information

52 78-4028088-01 Rev B

If You Have Questions If you have technical questions, call Cisco Services for assistance. Follow the menu options to speak with a service engineer.

Access your company's extranet site to view or order additional technical publications. For accessing instructions, contact the representative who handles your account. Check your extranet site often as the information is updated frequently.

5 Chapter 5 Customer Support Information

Page 61: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

78-4028088-01 Rev B 53

D

DLC Dense Fiber Chassis. Lumin chassis.

DLL Dense Lumin Lite Chassis. Lumin chassis.

DLT Dense Fiber Transmitter. Lumin transmitter.

DRP Dense Redundant Power Chassis. Lumin chassis.

E

EMC electromagnetic compatibility. A measure of equipment tolerance to external electromagnetic fields.

ESD electrostatic discharge. Discharge of stored static electricity that can damage electronic equipment and impair electrical circuitry, resulting in complete or intermittent failures.

Ethernet A standard protocol (IEEE 802.3) for a 10 Mbps local area network (LAN) that uses carrier sense multiple access with collision detection (CSMA/CD) to handle simultaneous access demands. Ethernet is the most widely-installed LAN technology. An Ethernet LAN typically uses coaxial cable or special grades of twisted-pair wires. The most commonly installed Ethernet systems are called 10-BaseT and provide transmission speeds up to 10 Mbps.

F

FCC Federal Communications Commission. Federal organization set up by the Communications Act of 1934 which has authority to regulate all inter-state (but not intra-state) communications originating in the United States (radio, television, wire, satellite, and cable).

Glossary

Page 62: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Glossary

54 78-4028088-01 Rev B

G

GHz Gigahertz. A unit of frequency equal to one billion cycles per second.

H

HFC hybrid fiber/coaxial. A network that uses a combination of fiber optics and coaxial cable to transport signals from one place to another. A broadband network using standard cable television transmission components, such as optical transmitters and receivers, coaxial cable, amplifiers, and power supplies. The broadband output stream is transmitted as an optical signal, over the high-speed, fiber optic transmission lines to local service areas where it is split, converted to electrical RF signals, and distributed to set-tops over coaxial cable.

I

IP address Internet protocol address. A 32-bit sequence of numbers used for routing IP data. Each IP address identifies a specific component on a specific network. The address contains a network address identifier and a host identifier.

ISO International Organization for Standardization. An international body that defines global standards for electronic and other industries.

M

MAC address media access control address. A unique 48-bit number that identifies the input/output card of a particular device. The MAC address is programmed into the card by the manufacturer. The MAC sub-layer handles access to shared media.

MHz megahertz. A unit of measure representing one million cycles per second; measures bandwidth.

MIB management information base. SNMP collects management information from devices on the network and records the information in a management information base. The MIB information includes device features, data throughput statistics, traffic overloads, and errors.

N

nm nanometer. One billionth of a meter.

P

PC personal computer.

Page 63: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Glossary

78-4028088-01 Rev B 55

Q

QAM quadrature amplitude modulation. A phase modulation technique for representing digital information and transmitting that data with minimal bandwidth. Both phase and amplitude of carrier waves are altered to represent the binary code. By manipulating two factors, more discrete digital states are possible and therefore larger binary schemes can be represented.

R

RMA return material authorization. A form used to return products.

S

SNMP simple network management protocol. A protocol that governs network management and the monitoring of network devices and their functions.

V

V AC volts alternating current.

V DC volts direct current.

Page 64: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user
Page 65: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

78-4028088-01 Rev B 57

A Accessing via SNMP • 37 Alarm Info MIB • 48 Assigning IP Address • 19, 32 Assigning Names • 18, 29

C Caveats • 50 Chassis Details • 12, 21 Connecting via Ethernet Port • 21 Connecting via Serial Port (DLC) • 12 Customer Support Information • 52

D DDR Receiver Module Control • 17, 28 DLC • 53 DLL • 53 DLT • 53 DLT Transmitter Module Control • 16, 26 DRP • 53

E EMC • 53 ESD • 53 Ethernet • 53 Ethernet Connection • 8

F FCC • 53 Frequently Asked Questions • 51

G GHz • 54

H HFC • 54

I Initial Setup • 7 Installation • 3 Introduction • 1, 36

IP address • 54 ISO • 54

L Lumin MIB Contents • 38

M MAC address • 54 MHz • 54 MIB • 54 Minimum Requirements • 4 modDDRTable Elements • 46 modDLTTable Elements • 43 Module Details • 14, 24

N Network Alarm Notification • 31 nm • 54

O Operating the Lumin Chassis and Modules

Using the Lumin Utility • 11

P PC • 54

Q QAM • 55

R RMA • 55 RS-232 Connection • 7

S Service Mode • 32 SNMP • 55 SNMP Management • 35 SNMP Setup • 4 Standard Lumin MIBS • 38 stdChassisInfo Elements • 40 stdModule Elements • 43

Index

Page 66: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Index

58 78-4028088-01 Rev B

T Trap Description • 49

U Utility Setup • 4

V V AC • 55 V DC • 55 Viewing the Lumin MIB • 38

Page 67: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user
Page 68: Cisco Lumin Dense Fiber Chassis (DLC) Configuration Guide · Overview : This guide provides information regarding the Cisco Lumin™ Utility, a software program that allows the user

Cisco Systems, Inc. 5030 Sugarloaf Parkway, Box 465447 Lawrenceville, GA 30042

678 277-1120 800 722-2009

www.cisco.com This document includes various trademarks of Cisco Systems, Inc. Please see the Notices section of this document for a list of the Cisco Systems, Inc. trademarks used in this document. Product and service availability are subject to change without notice. © 2009, 2012 Cisco and/or its affiliates. All rights reserved. October 2012 Printed in USA

Part Number 78-4028088-01 Rev B