Cim-tek CLM
-
Upload
maz-bintang -
Category
Documents
-
view
228 -
download
0
Transcript of Cim-tek CLM
-
7/28/2019 Cim-tek CLM
1/14
-
7/28/2019 Cim-tek CLM
2/14
CenturionIw/Adaptor
Designed for highvolume service station applications,commercial fueling centers, marine fueling centers, agriculturafueling, and truck stop fueling centers
Filter housings and replaceable elements are compatible withgasoline, diesel, methanol and ethanol blends up to 10%,biodiesel up to B20, and ultra-low sulfur diesel (ULSD)
Filter housings may be used in hydraulic oil applications
Demonstrated extended equipment life
Assures delivery of quality fuel
Cleaner change-out with draincock design
Eco-friendly reusable housing
Application
CENTURION I
Design Features
Benefits
HIGHVOLUMESingle Housing Assembly
30 gpm (113 lpm) maximum flow
Standard 1" NPT inlet/outlet flow area
Elements are available in 10 and 30micron paper for particulate removal
Elements are available in 10 and 30micron Hydrosorbmedia for waterdetection and particulate removal
Elements are available in 2 micronCellulose/Microglass blend for longerlife of particulate removal
Equipped with a draincock for easydrainage of captured contaminants
MODEL: CENTURION I
5.1
PETROLEUMFILTER TECHNOLOGY FOR PETROLEUM PRODUCTS
-
7/28/2019 Cim-tek CLM
3/14
Centurion I Dimensional Information
Ordering Information
Centurion I Elements
Part No. Model Description
Single
Adaptor40001
Part No. Model No. Description
E0230065
30002
30004
30033
30036
E10
E30
EHS-10
EHS-30
30195 E-10M Element for Particulate Removal. 10 Micron High Performance Micgroglass Med
Element for Particulate Removal. HighPerformance 2 Micron Microglass/Cellulo
Media Blend.
Element for Particulate Removal. 10 Micron Cellulose Media.
Element for Particulate Removal. 30 Micron Cellulose Media.
Element for Water Detection and Particulate Removal. 10 Micron HydrosorbMedia.
Element for Water Detection and Particulate Removal. 30 Micron HydrosorbMedia.
Centurion I w/Adaptor Filter Element Section View of Element
14 1/2"
5 1/4"4 1/2"
9 1/16"
NOTE: 1. Element includes gaskets, washer, and filter element.
2. Filters are not to be used with aviation applications.
Housing Kit Consisting of Adaptor, Housing, Washer, Acorn Nut, and Draincock.
Element Not Included. (1"NPT Inlet/Outlet)
201 N. CHAMPAIGN STREET BEMENT, IL 61813 TOLL FREE PHONE: 888-898-7187 TOLL FREE FAX: 888-515-2611PHONE: 217-678-2511 FAX: 217-678-2611 [email protected] WWW.CIM-TEK.COM
CENTRAL ILLINOIS MANUFACTURING COMPANY
Material: Aluminum adaptor
Used on: Centurion I
Inlet/Outlet ports: 1" NPT
Description DimensionsAdaptor Part No.
90004
-
7/28/2019 Cim-tek CLM
4/14
Designed for high-volume service station applications,commercial fueling centers, marine fueling centers, agriculturafueling, and truck stop fueling centers
Filter housings and replaceable elements are compatible withgasoline, diesel, methanol and ethanol blends up to 10%,biodiesel up to B20, and ultra-low sulfur diesel (ULSD)
Filter housings may be used in hydraulic oil applications
Parallel flow applications
Demonstrated extended equipment life
Assures delivery of quality fuel
Cleaner change-out with draincock design
Eco-friendly resuable housing
60 gpm (227 lpm) maximum flow
Standard 1 1/2" NPT inlet/outlet flow
Elements are available in 10 and 30micron paper for particulate removal
Elements are available in 10 and 30micron Hydrosorbmedia for waterdetection and particulate removal
Elements are available in 2 micronCellulose/Microglass blend forlonger life
Equipped with a draincock
CENTURION III
Centurion IIIw/Adaptor
CENTURION IIIHIGHVOLUMEDual Housing Parallel Flow
5.5
PETROLEUMFILTER TECHNOLOGY FOR PETROLEUM PRODUCTS
-
7/28/2019 Cim-tek CLM
5/14
Centurion III Dimensional Information
Ordering Information
Centurion III Elements
Part No. Model Description
Dual
Adaptor40013
Part No. Model No. Description
E0230065
30002
30004
30033
30036
E10
E30
EHS-10
EHS-30
Filter ElementSection View of Element
4 1/2"
9 1/16"
Centurion III w/Adaptor
14 1/2"
10 1/2"
NOTE: 1. Element includes gaskets, washer, and filter element.
2. Filters are not to be used with aviation applications.
3. Centurion III requires two elements.
Element for Particulate Removal. High Performance 2 Micron Microglass/Cellulo
Media Blend.
Element for Particulate Removal. 10 Micron Cellulose Media.
Element for Particulate Removal. 30 Micron Cellulose Media.
Element for Water Detection and Particulate Removal. 10 Micron Hydrosorb
Media.
Element for Water Detection and Particulate Removal. 30 Micron Hydrosorb
Media.
Housing Kit Consisting of Adaptor, Housing, Washer, Acorn Nut, and Draincock.
Element Not Included. (1 1/2" NPT Inlet/Outlet)
201 N. CHAMPAIGN STREET BEMENT, IL 61813 TOLL FREE PHONE: 888-898-7187 TOLL FREE FAX: 888-515-2611PHONE: 217-678-2511 FAX: 217-678-2611 [email protected] WWW.CIM-TEK.COM
CENTRAL ILLINOIS MANUFACTURING COMPANY
Material: Aluminum adaptor
Used on: Centurion III
Inlet/Outlet ports: 1 1/2" NPT
Description DimensionsAdaptor Part No.
90014
30195 E-10M Element for Particulate Removal. 10 Micron High Performance Micgroglass Med
-
7/28/2019 Cim-tek CLM
6/14
Designed for highvolume service station applications,commercial fueling centers, marine fueling centers, agriculturalfueling, and truck stop fueling centers
Filter housings and replaceable elements are compatible with
gasoline, diesel, methanol and ethanol blends up to 10%,biodiesel up to B20, and ultra-low sulfur diesel (ULSD)
Filter housings may be used in hydraulic oil applications
Triple parallel flow applications
90 gpm flow capacity
Demonstrated extended equipment life
Numerous element options
Assures delivery of quality fuels
90 gpm (340 lpm) maximum flow
Standard 2" NPT inlet/outlet flow
Elements are available in 10 and 30micron paper for particulate removal
Elements are available in 10 and 30micron Hydrosorbmedia for waterdetection and particulate removal
Elements are available in 2 micronCellulose/Microglass blend for longerlife
Equipped with a draincock for easydrainage of captured contaminants
CENTURION IV
CENTURION IVHIGHVOLUMEThree Element Parallel Flow
Centurion IVw/Adaptor
5.7
PETROLEUMFILTER TECHNOLOGY FOR PETROLEUM PRODUCTS
-
7/28/2019 Cim-tek CLM
7/14
Centurion IV Dimensional Information
Ordering Information
Centurion IV Elements
Part No. Model Description
Triple
Adaptor40020
Part No. Model No. Description
E0230065
30002
30004
30033
30036
E10
E30
EHS-10
EHS-30
Filter ElementSection View of Element
4 1/2"
9 1/16"
Centurion IV w/Adaptor
14 1/2"
10 1/2"
NOTE: 1. Element includes gaskets, washer, and filter element.
2. Consult Cim-Tek Filtration for oil, methanol, and ethanol compatability. 3. Filters are not to be used with aviation applications. 4. Centurion IV requires three elements.
201 N. CHAMPAIGN STREET BEMENT, IL 61813 TOLL FREE PHONE: 888-898-7187 TOLL FREE FAX: 888-515-2611PHONE: 217-678-2511 FAX: 217-678-2611 [email protected] WWW.CIM-TEK.COM
CENTRAL ILLINOIS MANUFACTURING COMPANY
Element for Particulate Removal. High Performance 2 Micron Microglass/Cellul
Media Blend.
Element for Particulate Removal. 10 Micron Cellulose Media.
Element for Particulate Removal. 30 Micron Cellulose Media.
Element for Water Detection and Particulate Removal. 10 Micron HydrosorbMedia.
Element for Water Detection and Particulate Removal. 30 Micron HydrosorbMedia.
Housing Kit Consisting of Adaptor, Housing, Washer, Acorn Nut, and Draincock.
Element Not Included. (2" NPT Inlet/Outlet)
Material: Aluminum adaptor
Used on: Centurion IV
Inlet/Outlet ports: 1" NPT
Description DimensionsAdaptor Part No.
90015
30195 E-10M Element for Particulate Removal. 10 Micron High Performance Micgroglass Me
-
7/28/2019 Cim-tek CLM
8/14
Application
VIKING 1
Design Features
Benefits
FILTER HOUSING
Capable of filtering gasoline, ethanol blends up to E15, biodieseblends up to B100, diesel fuel, ultra-low sulfur diesel (ULSD), anfuel oils
Industrial fluids such as lubrication oils, hydraulic oils, syntheti
oils, transformer oils, many solvents, and thinners may be filter
Bulk fueling racks and bulk fluid transfer
Removes common contaminants such as dirt, dust, and rust
Increased filtering capacity
Easy opening and access with swing down lid
Full ASME Certification available
120 gpm (450 lpm) maximum flow
150 psi rating
Standard 2" NPT inlet/outlet flow,flanged available
Epoxy coated on inside and outside
3 bolt swing down lid
Inlet to Outlet dimensions 12"(2" NPT)
Inlet to Outlet dimensions 13 1/2"(Flanged model)
12"x12" bottom plate
Carbon Steel housing
1/4" ports for the optional pressuregauge kit
Requires 1 6"x18" element
MODEL: VIKING 1 & 1F
6.1
Viking 1FFlanged
PETROLEUMFILTER TECHNOLOGY FOR PETROLEUM PRODUCT
-
7/28/2019 Cim-tek CLM
9/14
201 N. CHAMPAIGN STREET BEMENT, IL 61813 TOLL FREE PHONE: 888-898-7187 TOLL FREE FAX: 888-515-2611PHONE: 217-678-2511 FAX: 217-678-2611 [email protected] WWW.CIM-TEK.COM
CENTRAL ILLINOIS MANUFACTURING COMPANY
6.2
Ordering Information
Viking 1 DimensionalInformation
Viking 1 Housing
Top View of Lid
6"
18"
E-1300-02
E-1300-10
E-1300-30
E-1300MG-03
E-1300MG-05
E-1300MG-10
E-1300HS-10
E-1300HS-30
Viking 1 ElementsPart No. Model Description Use With
30066
30008
30009
30204
30203
30202
30034
30037
Element for Particulate Removal. 2 Micron Cellulose/Microglass
Media Blend.
Element for Particulate Removal. 10 Micron Cellulose Media.
Element for Particulate Removal. 30 Micron Cellulose Media.
Element for Particulate Removal. 3 Micron High PerformanceMicroglass Media.
Element for Particulate Removal. 5 Micron High PerformanceMicroglass Media.
Element for Particulate Removal. 10 Micron High Performance
Microglass Media.
Element for Water Detection and Particulate Removal. 10 MicronHydrosorb Media.
Element for Water Detection and Particulate Removal. 30 MicronHydrosorb Media.
All Above
All Above
All Above
All Above
All Above
All Above
All Above
All Above
Replacement Gaskets
90560 Standard Main Buna Gasket Seal Used On All Above
90599 Optional Main Viton Gasket Seal On All Above
Part No. Description
NOTE: Filters are not to be used with aviation applications.
NOTE: Viking 1 & 1F require one element.
32 1/2"28 1/2"
3 3/8"
7 1/2"
12"
Inlet Outlet
12"
9 1/2"
40186
40187
Viking 1
Viking 1FFlanged
Part No. Model Description (Elements Not Included.) Flow PSI NPT
Epoxy Coated Inside/Out Carbon Steel Filter Housing. 120 gpm 2" NPT
Epoxy Coated Inside/Out Carbon Steel Filter Housing. 120 gpm
150 psi
150 psi
-
7/28/2019 Cim-tek CLM
10/14
Capable of filtering gasoline, ethanol blends up to E15, biodieseblends up to B100, diesel fuel, ultra-low sulfur diesel (ULSD), anfuel oils
Industrial fluids such as lubrication oils, hydraulic oils, synthetoils, transformer oils, many solvents, and thinners may be filter
Bulk fueling racks and bulk fluid transfer
VIKING 2FILTER HOUSING
Viking 2F Flanged
MODEL: VIKING 2 & 2F
Design Features
BenefitsRemoves common contaminants such as dirt, dust, and rust
Increased filtering capacity
Easy opening and access with swing down lid
Full ASME Certification available
150 gpm (567.8 lpm) maximum flow
150 psi rating
Standard 2" NPT inlet/outlet flow,flanged available
Epoxy coated on inside and outside
3 bolt swing down lid
Inlet to Outlet dimensions 12"(2" NPT)
Inlet to Outlet dimensions 13 1/2"(Flanged model)
12"x12" bottom plate
Carbon Steel housing
1/4" ports for the optional pressuregauge kit
Requires 2 6"x18" elements
6.3
PETROLEUMFILTER TECHNOLOGY FOR PETROLEUM PRODUCT
-
7/28/2019 Cim-tek CLM
11/14
Viking 2 Dimens ionalInformation
Top View of Lid
Filter Element
6"
18"
201 N. CHAMPAIGN STREET BEMENT, IL 61813 TOLL FREE PHONE: 888-898-7187 TOLL FREE FAX: 888-515-2611
PHONE: 217-678-2511 FAX: 217-678-2611 [email protected] WWW.CIM-TEK.COM
CENTRAL ILLINOIS MANUFACTURING COMPANY
Ordering Information
E-1300-02
E-1300-10
E-1300-30
E-1300MG-03
E-1300MG-05
E-1300MG-10
E-1300HS-10
E-1300HS-30
Viking 2 ElementsPart No. Model Description Use With
30066
30008
30009
30204
30203
30202
30034
30037
Element for Particulate Removal. 2 Micron Cellulose/Microglass
Media Blend.
Element for Particulate Removal. 10 Micron Cellulose Media.
Element for Particulate Removal. 30 Micron Cellulose Media.
Element for Particulate Removal. 3 Micron High PerformanceMicroglass Media.
Element for Particulate Removal. 5 Micron High PerformanceMicroglass Media.
Element for Particulate Removal. 10 Micron High Performance
Microglass Media.
Element for Water Detection and Particulate Removal. 10 MicronHydrosorb Media.
Element for Water Detection and Particulate Removal. 30 Micron
Hydrosorb Media.
All Above
All Above
All Above
All Above
All Above
All Above
All Above
All Above
Replacement Gaskets
90560 Standard Main Buna Gasket Seal Used On All Above
90599 Optional Main Viton Gasket Seal Used On All Above
Part No. Description
NOTE: Filters are not to be used with aviation applications.
NOTE: Viking 2 & 2F require two elements.
Viking 2 Housing12"
7 1/2"Inlet Outlet
3 3/8"
46 1/2"
50 1/2"
9 1/2"
12"
40188
40189
Viking 2
Viking 2FFlanged
Part No. Model Description (Elements Not Included.) Flow PSI NPT
Epoxy Coated Inside/Out Carbon Steel Filter Housing. 150 gpm 2" NPT
Epoxy Coated Inside/Out Carbon Steel Filter Housing. 150 gpm
150 psi
150 ps
6.4
-
7/28/2019 Cim-tek CLM
12/14
VIKING3FFILTER HOUSING
Viking 3F Flanged
Application
Design Features300 gpm (1135.6 lpm) maximum flow
150 psi rating
Standard 3" flanged inlet/outlet flow
Epoxy coated on inside and out
8 bolt swing away lid
Inlet to Outlet dimensions 24"
Carbon Steel housing
1/4" ports for the optional pressuregauge kit
Requires 4 6"x18" elements
MODEL: VIKING 3F
Removes common contaminants such as dirt, dust, and rust
Increased filtering capacity
Convenient housing drain
Wide variety of filtering applications
Easy opening access and extra secure seal with 8 bolt swing lid
Full ASME Certification available
Benefits
6.5
Capable of filtering gasoline, ethanol blends up to E15, biodieseblends up to B100, diesel fuel, ultra-low sulfur diesel (ULSD), afuel oils
Industrial fluids such as lubrication oils, hydraulic oils, synthetoils, transformer oils, many solvents, and thinners may be filte
Bulk fueling racks and bulk fluid transfer
PETROLEUMFILTER TECHNOLOGY FOR PETROLEUM PRODUCT
-
7/28/2019 Cim-tek CLM
13/14
201 N. CHAMPAIGN STREET BEMENT, IL 61813 TOLL FREE PHONE: 888-898-7187 TOLL FREE FAX: 888-515-2611PHONE: 217-678-2511 FAX: 217-678-2611 [email protected] WWW.CIM-TEK.COM
CENTRAL ILLINOIS MANUFACTURING COMPANY
6.
Replacement Gaskets
90561 Standard Main Buna Gasket Seal Used On Viking 3F
90600 Optional Main Viton Gasket Seal Used On Viking 3F
Part No. Description
Viking 3F Housing
Ordering Information
Viking 3F Dimensional Information
Top View of Lid
NOTE: Viking 3F requires four elements.
NOTE: Filters are not to be used with aviation applications.
Filter Element
6"
18"
E-1300-02
E-1300-10
E-1300-30
E-1300MG-03
E-1300MG-05
E-1300MG-10
E-1300HS-10
E-1300HS-30
Viking 3F ElementsPart No. Model Description
30066
30008
30009
30204
30203
30202
30034
30037
Element for Particulate Removal. 2 Micron Cellulose/Microglass
Media Blend.
Element for Particulate Removal. 10 Micron Cellulose Media.
Element for Particulate Removal. 30 Micron Cellulose Media.
Element for Particulate Removal. 3 Micron High PerformanceMicroglass Media.
Element for Particulate Removal. 5 Micron High PerformanceMicroglass Media.
Element for Particulate Removal. 10 Micron High Performance
Microglass Media.
Element for Water Detection and Particulate Removal. 10 MicronHydrosorb Media.
Element for Water Detection and Particulate Removal. 30 Micron
Hydrosorb Media.
Inlet
40 1/2"
17"
59 1/4"
Outlet
6"
12"
12"
24"
40190
Viking 3F
Flanged Only
Part No. Model Description (Elements Not Included.) Flow PSI NPT
Epoxy Coated Inside/Out Carbon Steel Filter Housing. 300 gpm
150 psi
-
7/28/2019 Cim-tek CLM
14/14
500 gpm (1892.7 lpm) maximum flow
150 psi rating
Standard 4" flanged inlet/outlet flow
Epoxy coated on inside and outside
8 bolt swing away lid
Inlet to Outlet dimensions 28"
Carbon Steel housing
1/4" port for the optional pressuregauge kit
Requires 8 6"x 18" elements
Removes common contaminants such as dirt, dust, and rust
Increased filtering capacity
Convenient housing drain
Wide variety of filtering applications
Easy opening and extra secure seal with 8 bolt swing lid
Full ASME Certification available
VIKING 4F
Benefits
FILTER HOUSING
Viking 4FFlanged
MODEL: VIKING 4F
Capable of filtering gasoline, ethanol blends up to E15, biodieseblends up to B100, diesel fuel, ultra-low sulfur diesel (ULSD), afuel oils
Industrial fluids such as lubrication oils, hydraulic oils, synthetoils, transformer oils, many solvents, and thinners may be filte
Bulk fueling racks and bulk fluid transfer
PETROLEUMFILTER TECHNOLOGY FOR PETROLEUM PRODUC