Certificate No.: FRPP17511
Franklin Offshore Australia Pty Ltd
ABN 64 082 781 691Certificate No.:
CERTIFICATE OF LOAD TEST AND EXAMINATION
Address:Order No: Test Date:ORONTIDE MADCO
LOT 560 SPARKS ROAD HENDERSONP000112356 14/12/2018Client:
ClientID: SG-D252962/ FHH6040
7 Possner WayHENDERSON WA 6166Tel: 61-8-9410-6000 Fax: 61-8-9410-6001
Job Sheet No: 12405
6m half height container
Length: 6058mmWidth: 2438mmHeight: 1436mm
Tare: 3550kgNett: 9750kgMGM: 13300kg
13300kg33.25 tonnes on4 points
DNVGL-ST-E271:20171
Remarks
The items were found to comply to test specifications as detailed above.
The above test was performed by a competent person in accordance with the information provided.
Accredited Number: 3073Date of Issue:
Printed Name:
Signatory:
TestType
ANDREW BRIGGS
09/01/2019
PROOFLOAD
Form WIADM-007 Rev. 3
Accredited for compliance with ISO/IEC 17025
Manufacturer:
Surface Finish: PAINT
FERGUSON SEACABSLoad cell used: 55T tension Serial number: 7795
Page of1 1
Location of Test: Franklin Offshore Australia, 7Possner Way, Henderson
Franklin Offshore Australia Pty Ltd
ABN 64 082 781 691
CERTIFICATE OF MAGNETIC PARTICLE INSPECTION
Certificate No.: FRNP4624
Test Date: 27/11/2018
Test Date: 27/11/2018
7 Possner WayHENDERSON WA 6166Tel: 61-8-9410-6000 Fax: 61-8-9410-6001
Order No: P00109116Client:
Address:
ORONTIDE MADCO PTY LTD
46 SPARKS ROAD HENDERSON PERTH W.A 6166 Job Sheet: 12405
WCP: 26917BMI: 0917137
THIS TEST REVEALED NIL SURFACE DISCONTINUITIES OUTOF SPECIFICATION TO THE ABOVE ACCEPTANCECRITERIA AT THE TIME OF INSPECTION.
WELDS TESTED COMPLY.
TEST RESTRICTIONS: NIL
LOAD TEST NO.: FRPP16522 11/18
Material Spec:
Product Spec: Procedure No:
Test Sheet No:
Technique:
Penetrant Contact Time:
Developer Time:
Job Description:
Test Specification:
Acceptance Criteria:
Surface Condition:
Method of Surface Preperation:
Client ID:
TestID:
LOCATION AND ADDRESS OF TEST CONDUCTED:
TECHNICIAN:
CARBON STEEL
EDGARDO GARCIA
FRNP4624
MAGNETIC FLOW
WIWS 037 REV8
4624
FERRO-MAGNETIC
N/A
POWER WIRE BRUSHED
Magnaflux Y6: #7
AS WELDED
Franklin Offshore Australia, 7 Possner Way, Henderson
FHH6040
Approved Signatory:
DEAN OSBOINEPrinted Name:
Date of Issue: 22/01/2019
N/A
AWS D1.1: 2015-T 6.1
AS 1171-1998
Accredited for Compliance with ISO/IEC 17025
Accredited Number: 3073
Test Results / Indications :
NON COMPLIANTCOMPLIANT /
Batch Number:Equipment/Test Medium:
Pre and Post magnetic particle on 6m Half height container's four lifting lug weld attachments and Post-MPI on welds ofrepaired portions.
Form WIADM-007 Rev. 3
www.proofload.com.au 1 of 1
Certificate No. Job No.
CERTIFICATE FOR OFFSHORE CONTAINER LIFTING SLINGS Customer:
Customer Order No.
Customer Address:
Manufacturer: Address:
DNV Type Approval No. Type Designation:
Working Load Limit: Angle of Legs (To Vertical): No. / Dia. of sling legs: Length of legs:
Description of sling: ID No/Markings:
Wire Rope Slings Reference Standard: Grade of Wire Rope: Grade of terminal fittings:
QUAD: SHACKLES:
Chain Slings
Reference Standard: Material Grade: Reference to testing of mechanical properties after heat treatment:
Tests carried out on sling:
Lifting Set Components
Description Supplier/Manufacturer Identification Mark DNV Type Approval No.
The lifting set has been designed, approved and tested in accordance with DNVGL-ST-E271 “2.7-1 Offshore Containers"
The sling also conforms to the following standard(s):
Remarks:
DATE OF TEST:
APPROVED SIGNATORY
Head Office: 35 Resource Way, Malaga, WA 6090 P +61 8 92481288
Doc N.O. T-FR-0041 Rev. 0004
Hoover Ferguson Pty Ltd
FGA-PO007948
16 Alacrity Place, Henderson, WA 6166
Proofload Pty Ltd (Certificate Issuer) 35 Resource Way, Malaga, WA 6090
S-8398 N/A
13.3 Tonne 45° 4/26mm 4.57 Metres
26mm Grade 1960 4 Leg Wire Rope Assembly with Fram Q38B Masterlink Assembly and 9.5t Safety Bow Shackles
FSA260
AS3569 1960
N/A N/AN/A
133kN Each Leg, 264.9kN Masterlink, 186.4kN Shackles
Wire RopeMasterlinkShackles
Usha MartinFramVan Beest
D011/1920/43SABS6/BS6
N/ATAS0000048TAS00001D0
EN13414-1 & AS1666.1-2009
Shackles Stamped "260 A-D"4 Legs Replaced
17/07/2020
PDV2006 7205
80 60
Devon Haskins
Certificate of Visual Inspection
Certificate Number 166110
Ferguson Group Australia Pty Ltd trading as Hoover Ferguson
16 Alacrity Place
Henderson
WA 6166
14-Jan-2021 6M/20ft Half Height (Removable Sides)
6.058
2.438
1.436
3,550
9,750
13,300
14-Dec-2018
Date of Current Examination
Dimensions Equipment OwnerWeights Date of Previous
Examination
Date of Next
Examination/Test
Date of Current Proof
Load & Certificate Number
Length
Width
Height
Tare
Payload
Gross
Number & Position of Pad Eyes:
Lifting Set Description & ID Numbers Safe Working Load
Address of the premises at which the
examination was made
Cert Additional NotesInspector Name
FSA260
260A-D
Working Load Limit / Angle of Lift
13.3
9.5
FHH6040
Date Of Next
Examination/Test
13-Jan-2022
13-Jan-2022
27-Jul-2020
4 leg wire rope sling
4 Safety Pin Bow Shackles
Ferguson Group Australia Pty Ltd
16 Alacrity Place Henderson
Australia WA 6166
Kgs
Kgs
Kgs
Mtrs
Mtrs
Mtrs
t @ 0-45 deg
Joel Agnete
t
4 Top Mounted
FRPP17511
NO DEFECTS EVIDENT, INSPECTION PLATE
AND SLING TAG MARKED AS REQUIRED
Ferguson Group Pty Ltd,
16 Alacrity Place, Henderson
Australia WA 6166
Equipment ID No Unit Description
Inspection
Procedure
Inspection
Result
PASS
Sling Desc
Sling ID No.
Shackle Desc
Shackle ID No.
Last Date of Non-Destructive Testing: 24-Jan-2019 No Surface Defects were found at time of Inspection
13-Jan-2022
Pressure Test Run Out Hydrostatic Run Out
N/A N/A
In accordance with
DNV 2.7-1. Section
9.2 and Section 9.3
Accredited for compliance with ISO/IEC 17020.
NATA Accredited Inspection Number 16907.
This document must only be reproduced in full.
Page 1 of 1
Date of Issue 14-Jan-2021
Signed