CAT C175-16 2.5eMW Tier 4i Quote
Transcript of CAT C175-16 2.5eMW Tier 4i Quote
PRELIMINARY SPEC SHEET CATERPILLAR® Diesel Generator Set - 2,500 ekW Tier 4i 4160v
S stem Air Inlet
Cooling
Exhaust
Fuel
Generator
Governing System Control Panels Lube System
Mounting
Note
PRELIMINARY
C175-16 Continuous 2,500 ekW with Fan - 60 Hz - 1800 RPM
4,160 Volts
Standard • Single element canister type air cleaners • Dual element canister type air cleaners (optional) • Service indicators
• Radiator (optional, shipped loose) • Coolant drain line with valve • Cate illar Extended Life Coolant • Dry exhaust manifold • Flan ed faced outlets (ANSI/DIN) • Secondary and tertiary fuel filte • Fuel priming pump • Primary fuel filters with water se • Fuel cooler (optional, s ed laos
• PMG • Class H insulation • Class H temperature (I50°C rise) • CDVR voltage regulator • Reactive droop • B us bar connections • Winding temperature sensors (optional) • Anti-condensation space heaters (optional)
•
• Rubber, anti-vibration mounts (shipped loose) • Optional spring vibration isolators (shipped loose)
o tional seismic rated s rin vibration isolators (sm ed loose)
Dual 24 Volt starting motors (Quad starters optional) • 75 Amp charging alternator • Battery disconnect switch • Jacket water heater (optional) • Batteries with rack and cables (optional, shipped loose) • 20A, 35A, and 50A Battery chargers (optional, shipped loose) • Right-hand service • Paint - Caterpillar Yellow except rails and radiators gloss black • SAE standard rotation • Fl wheel and fl wheel housin - SAE No. 00
1 of 4
PRELIMINARY SPEC SHEET Diesel Generator Set - 2,500 ekW Tier 4i 4160v
Specifications
CA T Generator Excitation ....................... Permanent Magnet Pitch ................................................. 2/3 Number of poles ................................... 4 Number of bearings ............................... 2 Insulation ......... UL 1446 Recognized Class H IP rating ........................... Drip Proof IP23 Alignment ............................ close coupled Overspeed capability - % ofrated ............ 125 Wave form ................ Less than 5% deviation
Paralleling kit/Droop transformer ....... Standard Telephone Influence Factor ......... Less than 50 Harmonic distortion .................. Less than 5%
CAT Digital Voltage Regulator Microprocessor based V ARlPF control ............................. Standard Direct 3 Phase sensing with selectable voltslHz Communicates with EMCP 3 Programmable operating characteristics Voltage regulation ... Less than +/- 0.25% (steady state), Less than +/- 1 % (no load to full load) Compatible with self-excited, PMG, and IE
Stroke- mm ................... . Displacement - L ......... . Compression ratio ..... . Aspiration ........... . Fuel system ..... . Governor type.. .
PRELIMINARY 2 of 4
CATERPILLAR®
CA T EMCP Control Panels • EMCP 4.2 (Standard) • 24 Volt DC control
• Generator instruments designed ULlCSA/CEIUL508A
• Integral generator termill~
• Single location for
• MODBUS isolate,:l$Th supports serial cOlnmur kbaud)
• Auto staJrt/sto
L-N Volts, phase amps, Hz
, kVA, kVAR, kW-hr, %kW, PF
.,siiut,jmvns with indicating lights for:
Low oil pressure
High coolant temperture
Low coolant level
Overspeed
Emergency stop
Failure to start (over crank)
• Programmable protective relay functions:
Under and over voltage
Under and over frequency
Reverse power
Overcurrent (phase & total)
• Programmable kW level relay
CA T Control Options • Programmable annunciator (local and
remote or both) (2 max)
• Spare discrete 110 (16 inI8 out) (l max) • Generator temperature
monitor/protection (stator & bearing)
• Engine temperature monitor/protection
PRELIMINARY SPEC SHEET Diesel Generator Set - 2,500 ekW Tier 4i 4160v
Generator Set Technical Data
Package Performance Genset Power rating with fan Power @ 0.8
100% load with fan 75% load with fan 50% load with fan
Diesel Exhaust Fluid Consumption 100% load with fan 75% load with fan 50% load with fan
Cooling System
2,500 ekW ,125 kVA
675.8 Uhr 536.6 Uhr 443.7 Uhr
54.1 LIhr 42.9 LIhr 35.5 LIhr
CATERPILLAR®
178.5 Gallhr 141.8 Gallhr 117.2 Gallhr
14.3 Gallhr 11.3 Gallhr 9.4 Gallhr
Maximum external air flow restriction (system) Not available at this time Radiator air flow rate @ 0.5 external static restriction
air inlet flow rate
Exhaust System Exhaust stack gas temperature Exhaust gas flow rate Exhaust flange size (dual exhaust) (internal diameter) Exhaust
Heat Rejection Heat rejection to coolant Heat rejection to exhaust Heat rejection to aw"rc''''li"r Heat ection to
Emissions (Estimate Nominal) NOx glhp-hr He g/hp-hr co g/hp-hr PM
PRELIMINARY 3 of 4
238.1 m3/min
466°C 596.8 m3/min 355.6 mm 6.7 kPa
8408 eFM
870 of 21076 eFM
16 in. 27 in. H20
70,068 Btu/min 151,065 Btu/min 21,060 Btu/min 15,084 Btu/min
Not available at this time Emissions will meet US EPA Tier 4 Interim
Note: Do not use for installation design. Consult factory for final configuration.
PRELIMINARY SPEC SHEET Diesel Generator Set - 2,500 ekW Tier 4i 4160v CATERPILLAR® Generator Technical Data
CI75-16, Continuous, 60Hz, 1800 RPM 4,160 Volts
Heat Rejection 104.2 kW 5,931 Btu/min
Heat rejection to atmosphere from generator
Generator Motor starting capability @32.5%voltage dip, 0.4 PF 9,381 skVA Frame 1846 Winding Form Temperature Rise 105°C 221 of
Generator temperature rise is based on a 40°C ambient per NEMA MG 1-32.
Preliminary Package Mounted Radiator Dimensions
Ratings are based 0
BS5514 standard condi
PRELIMINARY
s installation design. for final configuration .
. H20) of external restriction and 6°C (11 OF) air to
: ABGSM TM3, AS1359, AS2789, BS4999, BS5000, C34/1, IS0304611, IS08528, JEM1359, and NEMA MG 1-32
conditions. These ratings also apply at IS03046/1, DIN6271, and
of API (16°C or 600P) gravity having an LHV of 42 780 kJ/kg (18,390 and weighing 838.9 glliter (7.001Ibs/U.S. gal.)
4 of 4
HI Ci T'
Rimeo Inc.
PO Box 362529 San Juan, PR 00936-2529 Tel: 787-792-4300 Fax: 787 774-6662 QUOTATION NO. IO-JG-0046
SUBJECT • • Quotation for a Caterpillar Generator Set
May 19, 2010
Weare pleased to present this quotation based on our interpretation of your requirements for a generator set. We offer the following:
ITEM (1):
One (1) CATERPILLAR POWER GENERATOR SET, MODEL CI75-16 -2500 EKW (Continuous Power Application) @ 0.8 Power Factor, 4160 Volts, 3 Phase, 4 Wires, 60 Hertz at 1800 RPM, TIER II, with the following standard accessories included:
Feature Code Qty Description Unit Price Currency Weight LIN All Total Price
lNSPEC4 II PREVENTATIVE MAlNT. lNSPECTION
CERTIF2 II TIER2 NONROAD MOBILE COMPLIANT
CERTUSA I llNSIDE US EPA LOCATIONS
CERTSTA II STATIONARY APPLICATION USE
NONULL I 1 NON UL 2200 LISTED PKG GEN SET
60H4160 1160HZ 4160 VOLTS
CONTlNU II CONTlNUOUS APPLICATION
ESCNONE_I1 No Extended Service Coverage
KW02600 I 1 2600 EKW W /0 FAN
EMCP33 II EMCP 3.3 CONTROL PANEL
REMRADl II REMOTE RADIATOR OR NO RADIATOR
CONFIG II MODIFIED CONFIGURATION
175DR12_I1 REF 175DE12, LF0019, LF0101
GENTl05 11105 DEG GENERATOR TEMP RISE
MSEPGGN_I 1 GENERAL EPG (non-enclosed)
MSCEC72 I 1 COMMERCIAL BUSlNESSES
MWCODEN_I 1 CONTlNUOUS (BASE LOAD)
1
QUOTATION NO. lO-JG-0046
LANENGO_I1 ENGLISH LANGUAGE OPTION
LANENGCI 1 ENGLISH LANGUAGE-GENSET CNTL
OGNPMFCI1 GENERATOR 1848 FRAME PM 2B FC
SHK0003_I1 GENERATOR SPACE HEATER
UIPBBHS_I1 CONTROL PANEL MOUNT REAR (STD)
CUSTCNR_I 1 CUSTOMER CONNECTION MTG RH SID
LSMOD05_I1 LOAD SHARE MODULE
RSELWR1_I1 RAISEILOWER SWITCH - 1800 FRM 167
PLUG004_I1 PLUG (NO PANEL LIGHTS)
CVR0017 _I 1 COVER GP (NO ANNUNCIATORS)
BOXGEN1_I 1 BASIC BOX 1
CT06005_I1 CURRENT TRANSF .. 600:5 RATIO
PLUG005_I1 PLUG GP (NO ETHER START) 0
PLUG006_I1 PLUG GP (NO AIR INLET SHUTOFF)
ACLSS04_I 1 AIR CLEANER - SINGLE ELEMENT
WIRGP06_I1 WIRING GP (W/O CYL TEMP SEN)
PLUG003_I1 PLUG (NO TURBO SPEED SENSORS)
RAD0008_S 1 REMOTE RADIATOR HORIZONTAL
FFFWS01_S 1 PRIMARY FUEL FILTER WIFW SEP 1
DPX0001_I1 DOMESTIC PACK-EXPORT CONTAINER
SRP0014_I1 STORAGE PRESERVATION
ELSM240_I1 ELEC STARTING MOTORS 24V
CVR0023_I1 COVER GP (2)- STARTER LOCATION
BAT1202_S 1 BATTERY SET 4 - 12 VOLT DRY
BTC3500_S 1 BATTERY CHG 35 AMP
CVR0026_I1 COVER GP - NO ALTERNATOR
HCPD001_I 1 HI CURRENT DISTRIBUTION BOX
CVR0025_I1 COVER GP - JACKET WATER HEATER
OILPN01_I1 STANDARD SUMP OIL PAN WIRAD
ELEPP05_I1 ELEC PRELUBE PUMP 24 VOLT 05
LUBOILU 1 LUBE OIL
LUBOD02_I1 DRAIN GP - OIL PAN
SPLEX02_I1 SIMPLEX OIL FILTER
CVR002U 1 COVER GP - CRANKCASE
FUMDISU 1 FUMES DISPOSAL Sl
May 19. 2010
2
QUOTATION NO. 10-JG-0046
MUF0036_S 1 MUFFLER - 20" 40 dBA
FLGWOOl_S 1 FLANGE, ANSI 20 1648
EXHBOOl_S 1 BELLOWS - BOLTED FLANGE
AFTPOOl_Il PLUG W/O AFTER COOLER DRAIN
BUSBLN2_Il 1000A MV BUS BARS LEFT (NEMA)
CVR0013_Il COVER GP - REAR (1)
CVROOI0_Il COVER GP - SIDE (2)
BOTCROl_Il MV BOTTOM CBL ENTRY NO SHROUD
CVROOI5_Il COVER GP - RIGHT
NGRDCNN_I 1 NEUTRAL GND CONNECTION MV
VIBIS42_S 1 LOW EFF ISO- 90% EFFECIENCY
May 19, 2010
NOTE: Customer is responsible for providing piping from genset to radiator and the correct Voltage for the radiator motors.
TOTAL PRICE F.O.B. FACTORY (LAFAYETTE, INDIANA) TAXES NOT INCLUDED:
WARRANTY One (1) year after initial start up.
VALIDITY Quotation is valid for 30 days.
ITEM (2) FffiLD FOLLOW UNIT
$ 766,800.00
One (1) CATERPILLAR POWER GENERATOR SET, MODEL C175-16-2500EKW (Continuous Power Application) @ 0.8 Power Factor, 4160 Volts, 3 Phase, 4 Wires, 60 Hertz at 1800 RPM, TIER 41 for Field Follow Site, with the following standard accessories included:
II C175-16EL C175-16 Package Gen Set II EXHC002_I 16" VERTICLE EXHAUST COLLECTOR S 1 FFFWSOl_S PRIMARY FUEL FILTER WIFW SEP 1 II FUMDISl_I FUMES DISPOSAL SI I 1 HCPDOOl_I HI CURRENT DISTRIBUTION BOX I 1 INSPEC4_I PREVENTATIVE MAINT. INSPECTION II KW02500_I 2500 EKW WIFAN II LANENGC_I ENGLISH LANGUAGE-GENSET CNTL II LSMOD05_I LOAD SHARE MODULE 05 I 1 LUBOD02_I DRAIN GP - OIL PAN 2 I 1 LUBOILl_I LUBE OIL I 1 NGRDCNN_I NEUTRAL GND CONNECTION MV I 1 NONULL_I NON UL 2200 LISTED PKG GEN SET II OGNPMFB_I GENERATOR 1846 FRAME PM 2B FB
3
QUOTATION NO. lO-JG-0046
II OILPNOU STANDARD SUMP OIL PAN WIRAD I 1 PLUG003 _I PLUG (NO TURBO SPEED SENSORS) I 1 PLUG004_I PLUG (NO PANEL LIGHTS) I 1 PLUG005 _I PLUG GP (NO ETHER START) II PLUG006_I PLUG GP (NO AIR INLET SHUTOFF)
II RSELWRU RAISEILOWER SWITCH - 1800 FRM I 1 SHK0003 _I GENERATOR SPACE HEATER II SPLEX02_I SIMPLEX OIL FILTER II UIPBBHS_I CONTROL PANEL MOUNT REAR (SID) S 1 VIBIS42_S LOW EFF ISO- 90% EFFECIENCY 42 II WIRGP06_IWIRING GP (W/O CYL TEMP SEN) II 175DRll_I REF 175DEll, LF0017, LFOI0l II 60H4160_I 60HZ 4160 VOLTS I 1 ACLSS04_I AIR CLEANER - SINGLE ELEMENT
II AFTPOOU PLUG WIO AFTERCOOLER DRAIN II AIDEMB_I AID EMBLEM S 1 BATl202_S BATTERY SET 4 - 12 VOLT DRY I 1 BOTCROl_I MV BOTTOM CBL ENTR Y NO SHROUD I 1 BOXGENl_I BASIC BOX 1 S 1 BTC3500_S BATTERY CHG 35 AMP I 1 BUSBLN2_I 1000A MV BUS BARS LEFT (NEMA) I 1 CER TMOB_I MOBILE APPLICATION USE I 1 CER TUSA_I INSIDE US EPA LOCATIONS II CONTINU_I CONTINUOUS APPLICATION II CT05005_I CURRENT TRANSF., 500:5 RATIO I 1 CUSTCNR_I CUSTOMER CONNECTION MTG RH STD II CVROOI0_I COVER GP - SIDE (2) II CVR0013_I COVER GP - REAR (1) II CVROOI5_I COVER GP - RIGHT II CVR0017_ICOVER GP (NO ANNUNCIATORS) I 1 CVR0021_I COVER GP - CRANKCASE II CVR0023_I COVER GP (2)- STARTER LOCATION II CVR0025_ICOVER GP - JACKET WATER HEATER II CVR0026_I COVER GP - NO ALTERNATOR II ELEPP05_I ELEC PRELUBE PUMP 24 VOLT 05 II ELSM240_I ELEC STARTING MOTORS 24V II EMCP33_I EMCP 3.3 CONTROL PANEL II CONFIG_IMODIFIED CONFIGURATION II GENTl05_I 105 DEG GENERATOR TEMP RISE I 1 LANENGO _I ENGLISH LANGUAGE OPTION
II REMRADU REMOTE RADIATOR OR NO RADIATOR II SRPOOI4_I STORAGE PRESERVATION II DPXOOOl_IDOMESTIC PACK-EXPORT CONTAINER II FACCOMl_I FACTORY COMMISSIONING I 1 MSCEC72_I COMMERCIAL BUSINESSES I 1 MSEPGGN_I GENERAL EPG (non-enclosed)
May 19, 2010
4
QUOTATION NO. lO-JG-0046
I 1 MWCODEN_I CONTINUOUS (BASE LOAD)
I 1 SWP0001_I SHRINK WRAP PROTECTION
II ESCNONE_I No Extended Service Coverage
With the following configuration: COUNT OF ALL ANNUNCIATORS 0
COUNT INSTALLED ANNUNCIATORS 0
Created on Date for record 04/28/2010
CBKCount 1 CONFIGURATION REF 175DEll, LF0017, LF0101
C175_16EL GENSIZE 1800 FRAME SIZE
VOLTAGE 60HZ 4160 VOLTS AIR CLEANERS AIR CLEANER - SINGLE ELEMENT
AFTER COOLER DRAIN PLUG WIO AFTERCOOLER DRAIN
PACKING AID EMBLEM
SD document category Quotation BATTERY SETS BATTERY SET 4 - 12 VOLT DRY
CABLE ENTRY (RIGHT SIDE-LV) MV BOTTOM CBL ENTRY NO SHROUD
CONTROL SYSTEM OPTIONS BASIC BOX 1
BATTERY CHARGER BATTERY CHG 35 AMP CIRCUIT BREAKER LEFT HAND 1000A MV BUS BARS LEFT (NEMA)
Distribution channel C1 MATERIAL NUMBER C175-16EL
CERTIFIED APPLICATION MOBILE APPLICATION USE
CERTIFICATION EMISSION LOC INSIDE US EPA LOCATIONS
STANDARD CONFIGURATION MODIFIED CONFIGURATION
DUTY TYPE CONTINUOUS APPLICATION CURRENT TRANSFORMERS CURRENT TRANSF., 500:5 RATIO
May 19, 2010
CUSTOMER CONNECTION LOCATION CUSTOMER CONNECTION MTG RH STD CIRCUIT BREAKER COVER COVER GP - SIDE (2)
CIRCUIT BREAKER COVER COVER GP - REAR (1)
CABLE ENTRY COVER COVER GP - RIGHT
ANNUNCIATOR COVERS COVER GP (NO ANNUNCIATORS)
PROTECTION SYSTEMS COVER GP - CRANKCASE
STARTING SYSTEM COVERS COVER GP (2)- STARTER LOCATION
JACKET WATER HEATERS COVER GP - JACKET WATER HEATER
CHARGING ALTERNATORS COVER GP - NO ALTERNATOR
DTO Indicator D EXPORT PACKING DOMESTIC PACK-EXPORT CONTAINER
Sales organization E901
PRELUBE PUMPS ELEC PRELUBE PUMP 24 VOLT 05
ELECTRIC STARTERS ELEC STARTING MOTORS 24V
EMCP 3 CONTROL PANEL EMCP 3.3 CONTROL PANEL
EXTENDED SERVICE COVERAGE No Extended Service Coverage EXHAUST SYSTEM 16" VERTICLE EXHAUST COLLECTOR
COMMISSIONING FACTORY COMMISSIONING
5
QUOTATION NO. lO-JG-0046
FUEL SYSTEM PRIMARY FUEL FILTER W/FW SEP 1
FUMES DISPOSALS FUMES DISPOSAL Sl
GENERATOR TEMPERATURE RISE 105 DEG GENERATOR TEMP RISE
HI CURRENT DISTRIBUTION BOX HI CURRENT DISTRIBUTION BOX
PREVENTATIVE INSPECTIONS PREVENTATIVE MAINT. INSPECTION
RATING 2500 EKW WIFAN LANGUAGE - GENSET CONTROLLER ENGLISH LANGUAGE-GENSET CNTL
LANGUAGE OPTIONS ENGLISH LANGUAGE OPTION
EMCP 3 CONTROL PANEL OPTIONS LOAD SHARE MODULE 05 OIL PAN DRAINS DRAIN GP - OIL PAN 2
LUBRICATION SYSTEM LUBE OIL
VOLTAGE DEFINED MEDIUM VOLTAGE PACKAGE
SUB MARKET CODE COMMERCIAL BUSINESSES MARKET SEGMENT GENERAL EPG (non-enclosed)
MARKET WORK CODE CONTINUOUS (BASE LOAD)
DELETION HELPER NEW _PET_SEGMENTS
GROUNDING CONNECTIONS REAR NEUTRAL GND CONNECTION MV
UL LISTING NON UL 2200 LISTED PKG GEN SET
OPTIONAL GENERATOR GENERATOR 1846 FRAME PM 2B FB
DEEP SUMP OIL PANS STANDARD SUMP OIL PAN W/RAD
TURBO SPEED SENSORS PLUG (NO TURBO SPEED SENSORS)
ADDL EMCP 3 ATTACHMENTS PLUG (NO PANEL LIGHTS)
STARTING AID OPTIONS PLUG GP (NO ETHER START)
AIR INLET SYSTEM PLUG GP (NO AIR INLET SHUTOFF)
Sales Document Type Quote
RADIATOR MOUNTING LOCATION REMOTE RADIATOR OR NO RADIATOR ADDL EMCP 3 ATTACHMENTS RAISEILOWER SWITCH - 1800 FRM
SPACE HEATER OPTIONS GENERATOR SPACE HEATER
OIL FILTERS SIMPLEX OIL FILTER
SHIPPING PROTECTION STORAGE PRESERVATION
SHRINK WRAP PROTECTION SHRINK WRAP PROTECTION EMCP 3 PANEL LOCATION CONTROL PANEL MOUNT REAR (STD)
MOUNTING SYSTEM LOW EFF ISO- 90% EFFECIENCY 42 PYROMETER AND THERMOCOUPLES WIRING GP (W/O CYL TEMP SEN)
Sales Document Type AUART YQTS
Sub-items 101 to 102 belong to item 100
Sub-items 104 to 105 belong to item 100
Sub-items 107 to 157 belong to item 100 101 II 3184550 INSPECTION-PM
102 I 1 LF0084 CORE ENGINE IRON 60 HZ - T2 SCAC
Sub-items 103 belongs to this item 102 103 I 13079788 ENGINE AR - C175-16
104 I 1 LF0112 3000S T2 MV WOR PACKAGING 105 I 1 LF0069 GEN AR-SR5-1846 3300V/4160V-FW-RTD-2B
Sub-items 106 belongs to this item 105 106 I 12523974 GENERATOR AR - POWER
May 19. 2010
6
QUOTATION NO. lO-JG-0046
107 I 1 LL6016 3717 BHP 2500 GEN KW WfF 60 HZ 108 I 1 9Y8164 CONTINUOUS POWER APPLICATION 109 I 1 5N9599 VOLTAGE INDICATOR 4160V, 60HZ 110 I 1 OV1065 END USE: GENERAL EPG 111 II LF0231 LANGUAGE MARKINGS - ENGLISH
112 I 1 LF0245 SINGLE STAGE ACL WI SERV IND 113 I 12853954 PLUG GP 114 I 13223173 HEATER GP-GEN 115 I 1 2527322 MTG GP-TRANSFORMER 117 I 1 LF0558 EXH. COLLECTION KIT - VERTICAL DUAL 16"
118 I 1 3096470 PLUG GP 119 I 1 LF0082 PRIMARY FUEL FILTER WIO PKG MID RADIATOR 120 12 8H1396 AID EMBLEM 121 II LF0093 ELECTRICAL GPS-W/O CYL TEMP SENSORS 122 I 1 2853955 PLUG GP 123 I 1 2474905 CONNECTION GP 124 I 1 LF0092 PAN & GAGE GP-OIL 125 I 1 LF0089 OIL - BULK
126 I 1 LF0212 ELECTRIC PRELUBE PUMP 24V STD PAN 127 I 1 LF0099 FILTER GP - PRIMARY OIL 128 I 1 LF0094 COVER GP - CRANKCASE
129 I 1 LF0243 FUMES DISPOSAL 130 S 1 2563178 MTG GP-ENG FLEX 131 II OP7824 DOMESTIC PACK-EXPORT CONTAINER 132 I 1 OP7607 SHRINK WRAP PROTECTION - 3516
133 I 12896091 PRESERVATION GP 134 I 1 2787089 CONNECTION GP 135 I 1 LF0161 MOTOR GP - DUAL ELECTRIC START 136 I 1 LF0057 COVER GP (STARTER LOCATIONS) 137 I 1 LF0098 COVER GP - JW HEATER
138 I 1 LF0209 BATTERY SET 139 I 1 3476645 COVER GP 140 I 1 3078694 MOUNTING GP-BREAKER 141 II LF0095 PLUG GP (ETHER) 142 S 1 3534423 CHARGER GP - BATTERY (35A) 143 I 1 LF0096 COVER GP - SIDE PANEL 144 I 1 3528717 COVER GP-REAR
145 I 1 LF0261 Voltage & Current Sensing MV 1800 Frame 146 I 1 2527502 .INSTRUCTIONS-AIR
147 I 1 2450096 COVER GP-SIDE EXTENSION BOTTOM 148 I 1 LF0275 EMCP3.3 - 1800 Frame
149 I 12527392 NOTE-CONTROL PANEL MOUNTING 150 I 1 2527394 INSTRUCTIONS 151 II 2527417 CONTROL GP 152 I 1 2678475 MOUNTING GP 153 I 1 LF0097 COVER GP - ANNUNCIATOR
May 19, 2010
7
QUOTATION NO. 10-JG-0046
154 I 1 2527700 PLUG
155 I 1 LF0064 CONTROL PANEL - MV, 1800 FRAME GENERATOR
156 I 1 2546368 ELEK GP-A6001
157 I 1 OV1160 OV1160 FACTORY COMMISSIONING
200 N 1 OV8707 DTO QUOTE DESIGN FEE
300 I 13541530 ENGINE AR - C175-16
400 I 13079788 ENGINE AR - C175-16 L
500 S 2 3558975 FITTING GP-EXHAUST
600 S 1 OV2319 DTO CEM (CLEAN EMISSIONS MODULE)
CAT CLEAN EMISSIONS MODULE (CEM)
# Diesel oxidation catalyst for particulate matter (PM) and hydrocarbon (HC) control
# Selective catalytic reduction (SCR) with integrated sound attenuation
700 S 1 OV2319 DTO RADIATOR
May 19, 2010
88 sq ft Remote, Horizontal Core Radiator with heresite coated cores, galvanized fraruework
and corrosion resistant control panel for coastal environment protection.
Performance Specifications:
Air flow: 111,428 actin
Fan consumes: 120 hp
50% Ethylene Glycol
Ambient: 11 O'F
Air rise: O'F
Elevation: 984 ft
External Static: 0.0" H20
JW temp: 210 'F
AC temp: 138.2 'F
Motor Data:
3ph, 208-230/460V, 60hz
WARRANTY:
VALIDITY • •
OPTIONAL EQUIPMENT:
TOTAL PRICE F.O.B. FACTORY (LAFAYETTE, INDIANA);TAXES NOT INCLUDED:
Field Follow Test Agreement
Quotation is valid for 30 days.
Point Guard Remote Monitoring System
$766,800.00
This proposal is to provide a remote monitoring system and PointGuard services to monitor and control two Caterpillar generators with EMCP3.3 and ADEM4 controls in a prime power application. This system requires customer provided broadband Internet communications.
8
QUOTATION NO. lO-JG-0046 May 19, 2010
Pricing and Deliverables
Equipment and Services Price (US$ Dealer Net)
1. Remote monitoring/supervisory control system with installation documentation and $10,255 drawings
2. Network router and configuration (required but can be supplied by customer) $1,165
3. Remote installation and commissioning assistance includes monitoring system installation support, PointGuard system check and startup, simulated alarm testing,
$95/hour standard and help for integration into customer network (estimated at 2 man-days)
These preferential rates are offered as part of the Instrumentation and Communications $115/hour after Agreement (ICA) for ease of support. Support provided through the leA is for all on-site hours issues including but not limited to ensuring that the instrumentation and communications systems are working to provide the necessary information to enable this proposal.
4. PointGuard Standard Services for 2 Generators with 15-min Data Logging and Daily Logged Data Upload includes:
a. 24/7/365 Monitoring for Alarms b. Automated Notification of Alarms through Email, Text Message or Page $130/month c. Data Gathering and Management d. Asset Displays on WebCenter e. Standard Reports: Alarm Historv and Site Run Reports
0 Graphic Site Intertace GSI $12/month
0 Data Sgreadsheet Regort $8/month
0 Trending Regort $10/month
0 Diagnostic Fault Codes $20/month
1. See PointGuard services specification sheets for more information. 2. Systems signed up for a three year services agreement receive a 10% discount off the service fees. 3. Systems signed up for a five year services agreement receive an additional 5% discount off the service fees. 4. Hardware shipment only after receipt of hard copy PO. Shipping will be prepaid by PointGuard and billed to the customer unless
othetwise agreed in advance. Customer can request preferred shipment method and need to provide customer account number. 5. All shipments are FOB London, Ontario, Canada
We will arrange for initial start-up services at no additional charge. These services include a check of wiring continuity, safety shutoffs and controls; including automatic transfer switches, on and related to the unit that we supply.
Thank you for the opportunity of quoting this project. If additional information or assistance is needed, please feel free to contact us.
Best Regards,
RIMCO,INC.
Jackson Galindez Sales Engineer Engine Division
Tel: (787) 273-5707 Fax: (787) 774-6662 Cell: (787) 502-0342 E-mail: [email protected]
9