D:\Compressor\Q405 (Gas Comp. Wailawi Wells)\CALCULATION\HTRI\coole3r.htri
3.25 ft
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
1
Name
TubeType1
Type
High-finned
OuterDiameter
(inch)
1.0000
WallThickness
(inch)
0.0830
TransversePitch(inch)
2.5000
LongitudinalPitch(inch)
2.1650
FinHeight(inch)
0.5000
Row
123
Numberof Tubes
151515
Tube Type
TubeType1TubeType1TubeType1
WallClearance
(inch)
0.37501.62500.3750
Row
456
Numberof Tubes
151515
Tube Type
TubeType1TubeType1TubeType1
WallClearance
(inch)
1.62500.37501.6250
Bundle InformationBundle widthNumber of tube rowsNumber of tubesMinimum wall clearance Left RightNumber of tubes per pass Tubepass # 1: Tubepass # 2: Tubepass # 3: Tubepass # 4:
3.2506
90
0.37500.3750
45151515
ft
inchinch