Buckling in semi-submersibles: a parametric … in semi-submersibles: a parametric analysis of...
Transcript of Buckling in semi-submersibles: a parametric … in semi-submersibles: a parametric analysis of...
Buckling in semi-submersibles: a parametric
analysis of damage
Winston Jin Young Chang
Thiago Pontin Tancredi
Sumário
Theoretical basis
DNV Standards (Recommended Practices)
Implementation of DNV Recommended Practices
Finite Element Method analysis applied in evaluation of buckling
Parametric analysis of damage
Conclusions
PRESENTATION TOPICS
• Structural fails can be separated in two categories:
– Material fail (Yield Strength)
– Structure instability (Buckling)
MOTIVATION
GOAL
• The critical buckling load is defined by the
solution of the differential equation of beam
equilibrium, respecting the boundary
conditions
THEORETICAL BASIS
Dados geométricos da coluna
Distância entre suportes efetivos do cilindro enrijecido por anéis
(L) [mm] 8000
Comprimento total do cilindro (LC) [mm] 8000
Raio da casca (r) [mm] 2000
Distância entre reforçadores longitudinais (s) [mm] 1571
Distância entre anéis (l) [mm] 1600
Espessura da casca (t) [mm] 100
Área da seção do reforçador (A) [mm²] 10000
Raio até a flange do anel (rf) [mm] 1800
Distância entre a aresta externa da flange e o centróide do anel
(zt) [mm] 50
Comprimento da alma do anel (h) [mm] 100
Espessura da alma do anel (tw) [mm] 100
Largura da flange do anel (b) [mm] 0
Espessura da flange do anel (tf) [mm] 0
Forças e momentos atuantes na coluna
Força axial de projeto (NSd) [N] -8392.106
Força cortante de projeto no eixo 1 (Q1Sd) [N] 0
Força cortante de projeto no eixo 2 (Q2Sd) [N] 0
Pressão lateral de projeto (pSd) [N/mm²] 0
Momento de torção de projeto (TSd) [N.mm] 0
Momento de projeto no eixo 1 (M1Sd) [N.mm] 0
Momento de projeto no eixo 2 (M2Sd) [N.mm] 0
Ângulo de aplicação dos momentos (θ) [rad] 0
σatuante/σflambagem
Painel curvo não enrijecido 2675%
Casca longitudinalmente enrijecida (85%)
Casca enrijecida por anéis 1405%
Coluna (1%)
IMPLEMENTATION
Espessura [mm] Reforçadores [mm²]
Coluna A 100 104
Coluna B 100 25
Coluna C 5 104
Coluna D 5 25
DESIGN OF EXPERIMENTS
Length: 8 m
Diameter: 4 m
Transversal rings: 4
Vertical stiffeners: 8
0
50
100
150
200
250
300
350
400
450
0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1
Tem
po
de p
rocessam
en
to [
s]
Tamanho do elemento [m]
0
0,02
0,04
0,06
0,08
0,1
0,12
0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 E
rro
(%
) Tamanho do elemento [m]
ANALYSIS OF CONVERGENCE
Espessura [mm] Reforçadores [mm²] Carga crítica de
flambagem [MN]
Coluna A 100 104 8392
Coluna B 100 25 7293
Coluna C 5 104 4584
Coluna D 5 25 2115
Analítico [MPa] Computacional [MPa] Diferença em relação ao
analítico
Coluna A 6675 6350 5%
Coluna B 5804 5930 2%
Coluna C 7295 3000 59%
Coluna D 3366 3000 11%
RESULTS
• Buckling is very affect by imperfections and damages
• Damages in columns of semi-submersible can have several
origins, as ships collisions, (especially supply boats)
ANALYSIS OF DAMAGE
[http://www.dnv.com.au/industry/maritime/servicessolutions/consulting/technicalconsulting/asa/shipcollisionana.asp]
[http://militarytimes.com/blogs/scoopdeck/2010/07/29/what-damaged-the-m-star-heres-what-it-wasnt/]
– Intersection of two identical columns
DAMAGE MODEL
[http://militarytimes.com/blogs/scoopdeck/2010/07/29/what-damaged-the-m-star-heres-what-it-wasnt/]
Carga crítica de flambagem das colunas avariadas [MN]
2m 4m 6m
2% 8033 7703 7583
4% 7263 6146 5681
6% 6571 5364 4882
8% 6325 5075 4381
10% 6182 4862 4204
Perda de resistência de flambagem das colunas avariadas
2m 4m 6m
2% 4% 8% 10%
4% 13% 27% 32%
6% 22% 36% 42%
8% 25% 40% 48%
10% 26% 42% 50%
RESULTS
4000
4500
5000
5500
6000
6500
7000
7500
8000
0 2 4 6 8 10 12
Carg
a c
ríti
ca d
e f
lam
ba
ge
m [
MN
]
Penetração (%)
2m
4m
6m
0
5
10
15
20
25
30
35
40
45
50
0 2 4 6 8 10 12
Perd
a d
e r
esis
tên
cia
de f
lam
bag
em
(%
)
Penetração (%)
2m
4m
6m
RESULTS
• Computational results consistent with the
theoretical formulations
• The implementation DNV verified
computationally is an excellent design tool for
naval architects
• The study of damages presented important
results that will be very useful for future
designs, improving safety and reducing the
structure weight.
CONCLUSIONS