Bomba P6010

22
96 Specifications subject to change without notice. VACUUM PUMPS P6010 P6010 Pi48-3X1 Patented COAX® technology Substationally lower air consumption as compared toconventional ejectors Modular design Available with multiple connection alternatives Low noise level Low feed pressure that ensures high realiabilityeven in case of pressure drops Short evacuation time Supplied with a vacuum gauge. TECHNICAL DATA VACUUM FLOW EVACUATION TIME BLOW FLOW Description Unit Value Feed pressure, max MPa 0.7 Noise level dBA 65–70 Temperature range °C -10–80 Weight g 1700–1800 Material Al, PA, NBR, SS, TPE Feed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuum MPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa 0.22 1.62 5.0 2.0 1.5 0.90 0.55 0.45 0.26 0.07 73 0.30 2.0 5.6 2.5 1.8 1.1 0.65 0.50 0.35 0.25 0.10 90 0.40 2.54 5.7 2.5 2.1 1.5 1.10 0.66 0.36 0.26 0.080 86 Feed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuum MPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa 0.22 1.62 0.025 0.080 0.090 0.30 0.50 0.80 1.7 73 0.30 2.0 0.020 0.060 0.12 0.30 0.45 0.70 1.0 1.6 4.0 90 0.40 2.54 0.020 0.055 0.11 0.18 0.29 0.59 0.90 1.7 86 Feed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressure MPa Nl/s 0 20 40 60 70 80 90 100 110 120 130 140 kPa 0.60 3.55 9.5 6.5 6.0 5.3 4.7 4.6 4.6 4.6 4.5 4.3 4.0 3.7 140 Vacuum flow Evacuation time Blow flow 0 1 2 3 4 5 6 0.22 MPa 0.30 MPa 0.40 MPa 90 80 70 60 50 40 30 20 10 0 Nl/s -kPa 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 0.22 MPa 0.30 MPa 0.40 MPa 90 80 70 60 50 40 30 20 10 2 4 6 8 10 0.60 MPa 140 130 120 110 100 90 80 70 60 40 20 0 Nl/s

description

Especificaciones tecnicas de una bomba P6010

Transcript of Bomba P6010

Page 1: Bomba P6010

96 Specifications subject to change without notice.

VACUUM PUMPS P6010

P6010 Pi48-3X1

Patented COAX® technologySubstationally lower air consumption as compared toconventional ejectors Modular design Available with multiple connection alternatives Low noise level Low feed pressure that ensures high realiabilityeven in case of pressure drops Short evacuation time

Supplied with a vacuum gauge.

TECHNICAL DATA

VACUUM FLOW

EVACUATION TIME

BLOW FLOW

Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 65–70Temperature range °C -10–80Weight g 1700–1800Material Al, PA, NBR, SS, TPE

Feed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.22 1.62 5.0 2.0 1.5 0.90 0.55 0.45 0.26 0.07 — — 730.30 2.0 5.6 2.5 1.8 1.1 0.65 0.50 0.35 0.25 0.10 — 900.40 2.54 5.7 2.5 2.1 1.5 1.10 0.66 0.36 0.26 0.080 — 86

Feed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.22 1.62 0.025 0.080 0.090 0.30 0.50 0.80 1.7 — — 730.30 2.0 0.020 0.060 0.12 0.30 0.45 0.70 1.0 1.6 4.0 900.40 2.54 0.020 0.055 0.11 0.18 0.29 0.59 0.90 1.7 — 86

Feed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 20 40 60 70 80 90 100 110 120 130 140 kPa0.60 3.55 9.5 6.5 6.0 5.3 4.7 4.6 4.6 4.6 4.5 4.3 4.0 3.7 140

Vacuum flow Evacuation time Blow flow

0

1

2

3

4

5

6

0.22 MPa0.30 MPa0.40 MPa

9080706050403020100

Nl/s

-kPa

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.00.22 MPa0.30 MPa0.40 MPa

908070605040302010 2

4

6

8

10

0.60 MPa

1401301201101009080706040200

Nl/s

Page 2: Bomba P6010

Specifications subject to change without notice. 97

VACUUM PUMPS P6010

Vac

uum

pum

psP

60

10

ORDERING INFORMATION

ORDERING INFORMATION, ACCESSORIES

1. Housing P6010 CodeHousing P6010

2. COAX® catridge modules P6010 Codea COAX® cartridge module Pi48-3X1 AJb COAX® cartridge module Pi48-3X1, non-return valve AN

3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 01

4. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plain LACover plate NPSF thread connections, Cover plate, plain LJ

5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x G3/4" 53Connections 2x G3/4", silencer 3/4" 54Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56Connections 2x 3/4" NPSF 57Connections 2x 3/4" NPSF, silencer 3/4" 58

Example Ordering numberP6010 Pi48-3X1, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AJ 01 LA 52

Description Art. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532

Page 3: Bomba P6010

98 Specifications subject to change without notice.

VACUUM PUMPS P6010

P6010 Pi48-3X2

Patented COAX® technologySubstationally lower air consumption as compared toconventional ejectors Modular design Available with multiple connection alternatives Low noise level Low feed pressure that ensures high realiabilityeven in case of pressure drops Short evacuation time

Supplied with a vacuum gauge.

TECHNICAL DATA

VACUUM FLOW

EVACUATION TIME

BLOW FLOW

Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 65–70Temperature range °C -10–80Weight g 1700–1800Material Al, PA, NBR, SS, TPE

Feed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.22 3.24 10.0 4.0 3.0 1.8 1.1 0.90 0.52 0.14 — — 730.30 4.0 11.2 5.0 3.6 2.2 1.3 1.0 0.70 0.50 0.20 — 900.40 5.08 11.4 5.0 4.2 3.0 2.2 1.3 0.7 0.52 0.16 — 86

Feed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.22 3.24 0.013 0.040 0.045 0.15 0.25 0.40 0.85 — — 730.30 4.0 0.010 0.030 0.060 0.13 0.23 0.35 0.50 0.80 2.0 900.40 5.08 0.010 0.028 0.055 0.090 0.15 0.30 0.45 0.85 — 86

Feed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 20 40 60 70 80 90 100 110 120 130 140 kPa0.60 7.1 19.0 13.0 12.0 10.6 9.4 9.2 9.2 9.2 9.0 8.6 8.0 7.4 140

Vacuum flow Evacuation time Blow flow

0

2

4

6

8

10

12

0.22 MPa0.30 MPa0.40 MPa

9080706050403020100

Nl/s

-kPa

0.0

0.5

1.0

1.5

2.0

0.22 MPa 0.30 MPa 0.40 MPa

90 80 70 60 50 40 30 20 10 5

10

15

20

0.60 MPa

1401301201101009080706040200

Nl/s

Page 4: Bomba P6010

Specifications subject to change without notice. 99

VACUUM PUMPS P6010

Vac

uum

pum

psP

60

10

ORDERING INFORMATION

ORDERING INFORMATION, ACCESSORIES

1. Housing P6010 CodeHousing P6010

2. COAX® catridge modules P6010 Codea COAX® cartridge module Pi48-3X2 AKb COAX® cartridge module Pi48-3X2, non-return valve AO

3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 01

4. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plain LACover plate NPSF thread connections, Cover plate, plain LJ

5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x G3/4" 53Connections 2x G3/4", silencer 3/4" 54Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56Connections 2x 3/4" NPSF 57Connections 2x 3/4" NPSF, silencer 3/4" 58

Example Ordering numberP6010 Pi48-3X2, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AK 01 LA 52

Description Art. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532

Page 5: Bomba P6010

100 Specifications subject to change without notice.

VACUUM PUMPS P6010

P6010 Pi48-3X3

Patented COAX® technologySubstationally lower air consumption as compared toconventional ejectors Modular design Available with multiple connection alternatives Low noise level Low feed pressure that ensures high realiabilityeven in case of pressure drops Short evacuation time

Supplied with a vacuum gauge.

TECHNICAL DATA

VACUUM FLOW

EVACUATION TIME

BLOW FLOW

Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 65–70Temperature range °C -10–80Weight g 1700–1800Material Al, PA, NBR, SS, TPE

Feed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.22 4.86 15.0 6.0 4.5 2.7 1.7 1.4 0.78 0.21 — — 730.30 6.0 16.8 7.5 5.4 3.3 2.0 1.5 1.1 0.75 0.30 — 900.40 7.62 17.1 7.5 6.3 4.5 3.3 2.0 1.1 0.78 0.24 — 86

Feed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.22 4.86 0.008 0.027 0.030 0.10 0.17 0.27 0.57 — — 730.30 6.0 0.007 0.020 0.040 0.083 0.15 0.23 0.33 0.53 1.3 900.40 7.62 0.007 0.018 0.037 0.060 0.097 0.20 0.30 0.57 — 86

Feed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 20 40 60 70 80 90 100 110 120 130 140 kPa0.60 10.65 29 19.5 18.0 15.9 14.1 13.8 13.8 13.8 13.5 12.9 12.0 11.1 140

Vacuum flow Evacuation time Blow flow

0

5

10

15

20

0.22 MPa0.30 MPa0.40 MPa

9080706050403020100

Nl/s

-kPa

0.0

0.3

0.6

0.9

1.2

1.5

0.22 MPa 0.30 MPa 0.40 MPa

90 80 70 60 50 40 30 20 10 10

15

20

25

30

0.60 MPa

1401301201101009080706040200

Nl/s

Page 6: Bomba P6010

Specifications subject to change without notice. 101

VACUUM PUMPS P6010

Vac

uum

pum

psP

60

10

ORDERING INFORMATION

ORDERING INFORMATION, ACCESSORIES

1. Housing P6010 CodeHousing P6010

2. COAX® catridge modules P6010 Codea COAX® cartridge module Pi48-3X3 ALb COAX® cartridge module Pi48-3X3, non-return valve AP

3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 01

4. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plain LACover plate NPSF thread connections, Cover plate, plain LJ

5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56

Example Ordering numberP6010 Pi48-3X3, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AL 01 LA 52

Description Art. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532

Page 7: Bomba P6010

102 Specifications subject to change without notice.

VACUUM PUMPS P6010

P6010 Pi48-3X4

Patented COAX® technologySubstationally lower air consumption as compared toconventional ejectors Modular design Available with multiple connection alternatives Low noise level Low feed pressure that ensures high realiabilityeven in case of pressure drops Short evacuation time

Supplied with a vacuum gauge.

TECHNICAL DATA

VACUUM FLOW

EVACUATION TIME

BLOW FLOW

Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 65–70Temperature range °C -10–80Weight g 1700–1800Material Al, PA, NBR, SS, TPE

Feed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.22 6.48 20.0 8.0 6.0 3.6 2.2 1.8 1.0 0.28 — — 730.30 8.0 22.4 10.0 7.2 4.4 2.6 2.0 1.4 1.0 0.40 — 900.40 10.16 22.8 10.0 8.4 6.0 4.4 2.6 1.4 1.0 0.32 — 86

Feed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.22 6.48 0.006 0.020 0.023 0.075 0.13 0.20 0.43 — — 730.30 8.0 0.005 0.015 0.030 0.063 0.11 0.18 0.25 0.40 1.0 900.40 10.16 0.005 0.014 0.028 0.045 0.073 0.15 0.23 0.43 — 86

Feed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 20 40 60 70 80 90 100 110 120 130 140 kPa0.60 14.2 38 26 24.0 21.2 18.8 18.4 18.4 18.4 18.0 17.2 16.0 14.8 140

Vacuum flow Evacuation time Blow flow

0

5

10

15

20

25

0.22 MPa0.30 MPa0.40 MPa

9080706050403020100

Nl/s

-kPa

0.0

0.2

0.4

0.6

0.8

1.0

0.22 MPa0.30 MPa0.40 MPa

908070605040302010 10

15

20

25

30

35

40

0.60 MPa

1401301201101009080706040200

Nl/s

Page 8: Bomba P6010

Specifications subject to change without notice. 103

VACUUM PUMPS P6010

Vac

uum

pum

psP

60

10

ORDERING INFORMATION

ORDERING INFORMATION, ACCESSORIES

1. Housing P6010 CodeHousing P6010

2. COAX® cartridge modules P6010 Codea COAX® cartridge module Pi48-3X4 AMb COAX® cartridge module Pi48-3X4, non-return valve AQ

3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 01

4. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plain LACover plate NPSF thread connections, Cover plate, plain LJ

5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56

Example Ordering numberP6010 Pi48-3X4, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AM 01 LA 52

Description Art. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532

Page 9: Bomba P6010

104 Specifications subject to change without notice.

VACUUM PUMPS P6010

P6010 Si32-3X1

Patented COAX® technologySubstationally lower air consumption as compared to conventional ejectors Modular design Available with multiple connection alternatives Low noise level High flow - suitable for handling of porous objects and in case of leakageShort evacuation time

Supplied with a vacuum gauge.

TECHNICAL DATA

VACUUM FLOW

EVACUATION TIME

BLOW FLOW

Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 60–65Temperature range °C -10–80Weight g 1700–1800Material Al, PA, NBR, SS, TPE

Feed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 -kPa0.40 1.25 5.0 2.9 1.9 1.2 0.80 0.40 0.10 — 600.50 1.5 5.7 3.3 2.2 1.4 0.85 0.62 0.35 0.18 700.60 1.75 6.0 3.5 2.6 1.7 0.90 0.60 0.50 0.35 75

Feed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 -kPa0.40 1.25 0.030 0.070 0.14 0.24 0.42 1.0 — 600.50 1.5 0.020 0.060 0.11 0.21 0.35 0.60 1.0 700.60 1.75 0.020 0.050 0.10 0.18 0.33 0.53 0.80 75

Feed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 10 20 30 40 50 60 70 80 kPa0.60 1.75 7.8 5.4 4.6 3.8 3.3 3.1 2.7 2.3 1.8 80

Vacuum flow Evacuation time Blow flow

0

1

2

3

4

5

6

0.40 MPa0.50 MPa0.60 MPa

706050403020100

Nl/s

-kPa

0.0

0.2

0.4

0.6

0.8

1.0

0.40 MPa 0.50 MPa 0.60 MPa

90 80 70 60 50 40 30 20 10

s/l

-kPa1

2

3

4

5

6

7

8

0.60 MPa

80706050403020100

Nl/s

Page 10: Bomba P6010

Specifications subject to change without notice. 105

VACUUM PUMPS P6010

Vac

uum

pum

psP

60

10

ORDERING INFORMATION

ORDERING INFORMATION, ACCESSORIES

1. Housing P6010 CodeHousing P6010

2. COAX® catridge modules P6010 Codea COAX® cartridge module Si32-3X1 ABb COAX® cartridge module Si32-3X1, non-return valve AF

3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 01

4. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plain LACover plate NPSF thread connections, Cover plate, plain LJ

5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x G3/4" 53Connections 2x G3/4", silencer 3/4" 54Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56Connections 2x 3/4" NPSF 57Connections 2x 3/4" NPSF, silencer 3/4" 58

Example Ordering numberP6010 Si32-3X1, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AB 01 LA 52

Description Art. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532

Page 11: Bomba P6010

106 Specifications subject to change without notice.

VACUUM PUMPS P6010

P6010 Si32-3X2

Patented COAX® technologySubstationally lower air consumption as compared to conventional ejectors Modular design Available with multiple connection alternatives Low noise level High flow - suitable for handling of porous objects and in case of leakageShort evacuation time

Supplied with a vacuum gauge.

TECHNICAL DATA

VACUUM FLOW

EVACUATION TIME

BLOW FLOW

Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 60–65Temperature range °C -10–80Weight g 1700–1800Material Al, PA, NBR, SS, TPE

Feed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.40 2.5 10.0 5.8 3.8 2.4 1.6 0.80 0.20 — — — 600.50 3.0 11.4 6.6 4.4 2.8 1.7 1.2 0.70 0.36 — — 700.60 3.5 12.0 7.0 5.2 3.4 1.8 1.2 1.0 0.70 — — 75

Feed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.40 2.5 0.015 0.035 0.070 0.12 0.21 0.50 — — — 600.50 3.0 0.010 0.030 0.055 0.11 0.18 0.30 0.50 — — 700.60 3.5 0.010 0.025 0.050 0.090 0.17 0.27 0.40 — — 75

Feed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 10 20 30 40 50 60 70 80 kPa0.60 3.5 15.5 10.8 9.2 7.6 6.6 6.2 5.4 4.6 3.6 80

Vacuum flow Evacuation time Blow flow

0

2

4

6

8

10

12

0.40 MPa0.50 MPa0.60 MPa

9080706050403020100

Nl/s

-kPa

0.0

0.1

0.2

0.3

0.4

0.5

0.40 MPa 0.50 MPa 0.60 MPa

90 80 70 60 50 40 30 20 10 0

5

10

15

20

0.60 MPa

80706050403020100

Nl/s

Page 12: Bomba P6010

Specifications subject to change without notice. 107

VACUUM PUMPS P6010

Vac

uum

pum

psP

60

10

ORDERING INFORMATION

ORDERING INFORMATION, ACCESSORIES

1. Housing P6010 CodeHousing P6010

2. COAX® cartridge modules P6010 Codea COAX® cartridge module Si32-3X2 ACb COAX® cartridge module Si32-3X2, non-return valve AG

3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 01

4. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plain LACover plate NPSF thread connections, Cover plate, plain LJ

5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x G3/4" 53Connections 2x G3/4", silencer 3/4" 54Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56Connections 2x 3/4" NPSF 57Connections 2x 3/4" NPSF, silencer 3/4" 58

Example Ordering numberP6010 Si32-3X2, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AC 01 LA 52

Description Art. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532

Page 13: Bomba P6010

108 Specifications subject to change without notice.

VACUUM PUMPS P6010

P6010 Si32-3X3

Patented COAX® technologySubstationally lower air consumption as compared to conventional ejectors Modular design Available with multiple connection alternatives Low noise level High flow - suitable for handling of porous objects and in case of leakageShort evacuation time

Supplied with a vacuum gauge.

TECHNICAL DATA

VACUUM FLOW

EVACUATION TIME

BLOW FLOW

Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 60–65Temperature range °C -10–80Weight g 1700–1800Material Al, PA, NBR, SS, TPE

Feed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.40 3.75 15.0 8.7 5.7 3.6 2.4 1.2 0.30 — — — 600.50 4.5 17.1 9.9 6.6 4.2 2.6 1.8 1.1 0.54 — — 700.60 5.25 18.0 10.5 7.8 5.1 2.7 1.8 1.5 1.1 — — 75

Feed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.40 3.75 0.010 0.023 0.047 0.080 0.14 0.33 — — — 600.50 4.5 0.007 0.020 0.037 0.070 0.12 0.20 0.33 — — 700.60 5.25 0.007 0.017 0.033 0.060 0.11 0.18 0.27 — — 75

Feed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 10 20 30 40 50 60 70 80 kPa0.60 5.25 23.3 16.2 13.8 11.4 9.9 9.3 8.1 6.9 5.4 80

Vacuum flow Evacuation time Blow flow

0

5

10

15

20

0.40 MPa0.50 MPa0.60 MPa

9080706050403020100

Nl/s

-kPa

0.00

0.05

0.10

0.15

0.20

0.25

0.30

0.35

0.40 MPa 0.50 MPa 0.60 MPa

90 80 70 60 50 40 30 20 10

s/l

-kPa5

10

15

20

25

0.60 MPa

80706050403020100

Nl/s

Page 14: Bomba P6010

Specifications subject to change without notice. 109

VACUUM PUMPS P6010

Vac

uum

pum

psP

60

10

ORDERING INFORMATION

ORDERING INFORMATION, ACCESSORIES

1. Housing P6010 CodeHousing P6010

2. COAX® cartridge modules P6010 Codea COAX® cartridge module Si32-3X3 ADb COAX® cartridge module Si32-3X3, non-return valve AH

3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 01

4. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plain LACover plate NPSF thread connections, Cover plate, plain LJ

5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56

Example Ordering numberP6010 Si32-3X3, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AD 01 LA 52

Description Art. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532

Page 15: Bomba P6010

110 Specifications subject to change without notice.

VACUUM PUMPS P6010

P6010 Si32-3X4

Patented COAX® technologySubstationally lower air consumption as compared to conventional ejectors Modular design Available with multiple connection alternatives Low noise level High flow - suitable for handling of porous objects and in case of leakageShort evacuation time

Supplied with a vacuum gauge.

TECHNICAL DATA

VACUUM FLOW

EVACUATION TIME

BLOW FLOW

Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 60–65Temperature range °C -10–80Weight g 1700–1800Material Al, PA, NBR, SS, TPE

Feed pressure Air consumption Vacuum flow (Nl/s) at different vacuum levels (-kPa) Max vacuumMPa Nl/s 0 10 20 30 40 50 60 70 80 90 -kPa0.40 5.0 20.0 11.6 7.6 4.8 3.2 1.6 0.40 — — — 600.50 6.0 22.8 13.2 8.8 5.6 3.4 2.4 1.4 0.72 — — 700.60 7.0 24.0 14.0 10.4 6.8 3.6 2.4 2.0 1.4 — — 75

Feed pressure Air consumption Evacuation time (s/l) to reach different vacuum levels (-kPa) Max vacuumMPa Nl/s 10 20 30 40 50 60 70 80 90 -kPa0.40 5.0 0.008 0.018 0.035 0.060 0.11 0.25 — — — 600.50 6.0 0.005 0.015 0.028 0.053 0.088 0.15 0.25 — — 700.60 7.0 0.005 0.013 0.025 0.045 0.083 0.13 0.20 — — 75

Feed pressure Air consumption Blow flow (Nl/s) at different pressure levels (kPa) Max pressureMPa Nl/s 0 10 20 30 40 50 60 70 80 kPa0.60 7.0 31 21.6 18.4 15.2 13.2 12.4 10.8 9.2 7.2 80

Vacuum flow Evacuation time Blow flow

0

5

10

15

20

25

0.40 MPa0.50 MPa0.60 MPa

9080706050403020100

Nl/s

-kPa

0.00

0.05

0.10

0.15

0.20

0.25

0.40 MPa 0.50 MPa 0.60 MPa

90 80 70 60 50 40 30 20 10

s/l

-kPa5

10

15

20

25

30

35

0.60 MPa

80706050403020100

Nl/s

Page 16: Bomba P6010

Specifications subject to change without notice. 111

VACUUM PUMPS P6010

Vac

uum

pum

psP

60

10

ORDERING INFORMATION

ORDERING INFORMATION, ACCESSORIES

1. Housing P6010 CodeHousing P6010

2. COAX® catridge modules P6010 Codea COAX® cartridge module Si32-3X4 AEb COAX® cartridge module Si32-3X4, non-return valve AI

3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 01

4. Cover plates P6010 CodeCover plate G thread connections, Cover plate, plain LACover plate NPSF thread connections, Cover plate, plain LJ

5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56

Example Ordering numberP6010 Si32-3X4, Mounting T-slot, Cover plate G-threads, Connections 2x G1" and silencer 1" P6010 AE 01 LA 52

Description Art. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 250 kPa 0112533Manometer 1 MPa 0112532

Page 17: Bomba P6010

112 Specifications subject to change without notice.

VACUUM PUMPS P6010

P6010 AVM™

Patented COAX® technologySuitable for vacuum systems using numerous large suction cups Valves for ON/OFF of vacuum and for blow-off Adjustment valve for controlling the blow-off flow Two vacuum switches with signal output.Automatic energy-saving function -can be switched off in applications where leakage is present Onesingle M12 8-pin electric connection that facilitatesinstallation PNP or NPNoutput selectable.

Supplied with a vacuum gauge.

TECHNICAL DATA

TECHNICAL DATA, SPECIFIC

PERFORMANCE TABLESDepending upon choice of COAX®Cartridge, applicable performance data of the P6010 AVM™ can be found inthe tables for vacuum flow and evacuation time for models P6010 Pi48-3x1 to x4 as well as for Si32-3x1 to x4.

ORDERING INFORMATION

Description Unit ValueFeed pressure, max. MPa 0.7Noise level dBA 50–70Material Al, PA, NBR, SS, PMMA, ABS, TPETemperature range °C 0–50Weight g 2000–2100Voltage VDC 24 (22–30)Ripple, max. Vp 1Vrms

Current consumption mA 110Safety classification IP65Current, max. output load mA 100Display LED indicators

Description Unit ValueLC, LL LD, LM LE, LN LF, LO LG, LP LH, LQ

Function, on/off NO NO NO NC NC NCSignal range -kPa 30/50 30/70 50/70 30/50 30/70 50/70

1. Housing P6010 CodeHousing P6010

2. COAX® catridge modules P6010 CodeCOAX® cartridge module Pi48-3X1, non-return valve ANCOAX® cartridge module Pi48-3X2, non-return valve AOCOAX® cartridge module Pi48-3X3, non-return valve APCOAX® cartridge module Pi48-3X4, non-return valve AQCOAX® cartridge module Si32-3X1, non-return valve AFCOAX® cartridge module Si32-3X2, non-return valve AGCOAX® cartridge module Si32-3X3, non-return valve AHCOAX® cartridge module Si32-3X4, non-return valve AI

3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 01

Page 18: Bomba P6010

Specifications subject to change without notice. 113

VACUUM PUMPS P6010

Vac

uum

pum

psP

60

10

NO = Normally open valve for vacuum on/off, NC = Normally closed valve for vacuum on/off

ORDERING INFORMATION, ACCESSORIES

4. Cover plates P6010 CodeFunction AVM™ NO 30/50, Cover plate G thread connections LCFunction AVM™ NO 30/70, Cover plate G thread connections LDFunction AVM™ NO 50/70, Cover plate G thread connections LEFunction AVM™ NC 30/50, Cover plate G thread connections LFFunction AVM™ NC 30/70, Cover plate G thread connections LGFunction AVM™ NC 50/70, Cover plate G thread connections LHFunction AVM™ NO 30/50, Cover plate NPSF thread connections LLFunction AVM™ NO 30/70, Cover plate NPSF thread connections LMFunction AVM™ NO 50/70, Cover plate NPSF thread connections LNFunction AVM™ NC 30/50, Cover plate NPSF thread connections LOFunction AVM™ NC 30/70, Cover plate NPSF thread connections LPFunction AVM™ NC 50/70, Cover plate NPSF thread connections LQ

5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56

Example Ordering numberP6010 Si32-3X2, Mounting T-slot, Cover plate with AVM™ NO 30/50 function and G-threads, Connections 2x G1" and silencer 1"

P6010 AG 01 LC 52

Description Art. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Manometer 1 MPa 0112532Cable 2m 0.25 x 7 PUR with electrical connector M12 8-pin 0110238

Page 19: Bomba P6010

114 Specifications subject to change without notice.

VACUUM PUMPS P6010

P6010 PCC

Patented COAX®technologyProgrammable for constant vacuum level or blow-pressure level in the system Quick adjustment Easy to install in control systems Low power consumption, 24 VDC/120 mAIntegrated analogue vacuum or blow-pressure sensor

Supplied with a vacuum gauge.

TECHNICAL DATA

The design of PCC requires that the inlet pressure is 0.1 MPa higher than the outlet pressure.

PERFORMANCE TABLESDepending upon choice of COAX® Cartridge, applicable performance data of the P6010 PCC can be found inthe tables for vacuum flow, evacuation time and blow flow for models P6010 Pi48-3x1 to x4 as well as for Si32-3x1 to x4.

ORDERING INFORMATION

Description Unit ValueFeed pressure, max. MPa 1.0Noise level dBA 50–70Temperature range °C 3–50Weight g 2100–2200Material Al, PA, NBR, SS, AiSi302Voltage supply VDC 24 (21.8–26.4)Current consumption mA <120Voltage signal, input/output VDC 0–10Scale factor signal out, vacuum -kPa 0–100Scale factor signal in, vacuum -kPa 0–90Scale factor signal out, blow MPa 0–0.2Safety classification IP65

1. Housing P6010 CodeHousing P6010

2. COAX® catridge modules P6010 CodeCOAX® cartridge module Pi48-3X1 AJCOAX® cartridge module Pi48-3X2 AKCOAX® cartridge module Pi48-3X3 ALCOAX® cartridge module Pi48-3X4 AMCOAX® cartridge module Si32-3X1 ABCOAX® cartridge module Si32-3X2 ACCOAX® cartridge module Si32-3X3 ADCOAX® cartridge module Si32-3X4 AE

3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 01

4. Cover plates P6010 CodeFunction PCC Vacuum, Cover plate G thread connections LBFunction PCC Blow, Cover plate G-thread connections LRFunction PCC Blow, Cover plate NPSF thread connections LSFunction PCC Vacuum, Cover plate NPSF thread connections LT

5. Connections for vacuum and exhaust P6010 CodeConnections 2x G1" 51Connections 2x G1", silencer 1" 52Connections 2x 1" NPSF 55Connections 2x 1" NPSF, silencer 1" 56

Page 20: Bomba P6010

Specifications subject to change without notice. 115

VACUUM PUMPS P6010

Vac

uum

pum

psP

60

10

ORDERING INFORMATION, ACCESSORIES

Example Ordering numberP6010 Si32-3X2, Mounting T-slot, Cover plate with PCC vacuum function and G-threads, Connections 2x G1" and silencer 1"

P6010 AC 01 LB 52

Description Art. No.Silencer G1" 0112499Silencer 1" NPSF 0113003Cable L=3m, M16 8-pin, angled 0112395Cable, L=3m, M16 8-pin, straight 0112393Manometer 1 MPa 0112532

Page 21: Bomba P6010

116 Specifications subject to change without notice.

VACUUM PUMPS P6010

P6010 CLASSIC

Patented COAX® technologyConnections can be made on the long side of the ejector Retro-compatible withPIAB’s Classic model in regard to mounting

Supplied with a vacuum gauge.

TECHNICAL DATA

PERFORMANCE TABLESDepending upon choice of COAX® Cartridge, performance data of the P6010 Classic can be found in the tablesfor vacuum flow, evacuation time and blow flow for models P6010 Pi48-3x1 to x4 as well as for Si32-3x1 to x4.

Description Unit ValueFeed pressure, max MPa 0.7Noise level dBA 50–65Temperature range °C -10–80Weight g 1700–1800Material Al, PA, NBR, SS, TPE

Page 22: Bomba P6010

Specifications subject to change without notice. 117

VACUUM PUMPS P6010

Vac

uum

pum

psP

60

10

ORDERING INFORMATION

ORDERING INFORMATION, ACCESSORIES

1. Housing P6010 CodeHousing P6010

2. COAX® cartridge modules P6010 Codea COAX® cartridge module Pi48-3X1 AJa COAX® cartridge module Pi48-3X2 AKa COAX® cartridge module Pi48-3X3 ALa COAX® cartridge module Pi48-3X4 AMb COAX® cartridge module Pi48-3X1, non-return valve ANb COAX® cartridge module Pi48-3X2, non-return valve AOb COAX® cartridge module Pi48-3X3, non-return valve APb COAX® cartridge module Pi48-3X4, non-return valve AQa COAX® cartridge module Si32-3X1 ABa COAX® cartridge module Si32-3X2 ACa COAX® cartridge module Si32-3X3 ADa COAX® cartridge module Si32-3X4 AEb COAX® cartridge module Si32-3X1, non-return valve AFb COAX® cartridge module Si32-3X2, non-return valve AGb COAX® cartridge module Si32-3X3, non-return valve AHb COAX® cartridge module Si32-3X4, non-return valve AI

3. Mounting P6010 CodeMounting T-slot, Cover plate with PIAB label 01

4. Cover plates P6010 CodeCover plate Classic G thread connections, Cover plate plain LICover plate Classic NPSF thread connections, Cover plate plain LK

5. Connections for vacuum and exhaust P6010 CodeConnections 2x G3/4" 53Connections 2x G3/4", silencer 3/4" 54Connections 2x 3/4" NPSF 57Connections 2x 3/4" NPSF, silencer 3/4" 58

Example Ordering numberP6010 Pi48-3X4, Mounting T-slot, Cover plate Classic G-threads, Connections 2x G3/4" and silencer 3/4" P6010 AM 01 LI 54

Description Art. No.Manometer 250 kPa 0112533Manometer 1 MPa 0112532Silencer G3/4” 3216002