SGEM 2006: SEction 12 [GaS GEnEratorS] 19312
Laboratory Gas Generators 194
Gas Generators
-
12 Gas Generators
SGEM 2006: SEction 12 [GaS GEnEratorS]194
If your laboratory has one or more applications that demand a constant, high volume of laboratory gas you may be able to justify the cost (wish to consider the purchase of) of a laboratory gas generator which could save you money and make improvements to your productivity and laboratory safety at the same time.
Gas Generators can be used with any instrumentation requiring high purity hydrogen, nitrogen or zero air, anywhere a standard electrical supply is available.
Typical applications demanding constant high laboratory gas flows and where a laboratory gas generator may be justified include:
LC/MS instruments
Spectrometers
Sample prep
Auto samplers
ELSD
Domnick Hunter Gas Generators, which can be supplied by BOC, have many other benefits to consider in addition to the potential cost savings for high volume laboratory gas users:
improve your analysis with UHP gas
improved safety
low pressure
minimal stored gas
no cylinder handling
improved reliability and productivity
never run out of gas
compact modular design
free up space
use anywhere in lab
aesthetic and ergonomic design
integrate into any laboratory
complement scientific instrumentation
easy to operate and maintain
quiet operation
minimal maintenance
after sale service
1 year warranty
global manufacturing support
service contracts and extended warranties available
BOC recommends that customers should always retain adequate back-up supplies of their laboratory gases in the event of a failure or shut down of their laboratory gas generator.
applications Guide
instrument Gas requirement Purity Flow rateGenerator recommended
Products for Gas chromatography
GC-FID Hydrogen for fuel gas UHP 3050 cc/min Hydrogen
Zero air for flame gas Hydrocarbon-free 300500 cc/min Zero Air
Hydrogen for capillary carrier gas
UHP 10 cc/min Hydrogen
Nitrogen for packed carrier gas
UHP, zero grade 2050 cc/min Zero Nitrogen
Nitrogen for make-up gas UHP, zero grade 3050 cc/min Zero Nitrogen
GC-FPD Hydrogen for fuel gas UHP 6090 cc/min Hydrogen
Zero Air for flame gas Hydrocarbon-free 90120 cc/min Zero Air
GC-NPD Hydrogen for capillary gas UHP 50 cc/min Hydrogen
Nitrogen for make-up gas UHP, zero grade 30 cc/min Zero Nitrogen
GC-ECD Nitrogen for carrier gas UHP, zero grade 60 cc/min Zero Nitrogen
Nitrogen for make-up gas UHP, zero grade 100 cc/min Zero Nitrogen
GC-TCD Hydrogen as carrier gas UHP 50 cc/min Hydrogen
GC-ATD Dry Air purge Clean and dry air
-
12
SGEM 2006: SEction 12 [GaS GEnEratorS] 195
Laboratory Gas Generators
instrument Gas requirement Purity Flow rateGenerator recommended
Products for LcMS instruments
LCMS API/LCMS Air for nebulizer gas Clean and dry air, hydrocarbon free 99.5%
18 L/min Clean Dry Air or Zero Air NitrogenAPCI, Electrospray
LCMS/MS, TOFNitrogen for curtain and sheath shield gas
535 L/min
Products for Spectroscopy
FT-IR Spectrometer Purge gas for sample compartment, optics, air bearing and microscope
Clean dry, CO2 free 1485 L/min CO2 free air
NMR Spectrometer Air for lifting spinning and ejecting
Clean and dry air 300 L/min Clean Dry Air
ICP Spectrometer Nitrogen or zero nitrogen for purge gas
99.99 + % 9 L/min Nitrogen or Zero Nitrogen
AA Spectrometer Air for oxidant gas Clean and dry air 20200 L/min Clean Dry Air
Products for analysers
TOC Dry air or Nitrogen for carrier gas or combustion gas
Clean dry, CO2 free/ hydrocarbon free
100500 cc/min CO2 free air/ Zero Air
UHP 50700 cc/min Zero Nitrogen
THA Zero air for FID Hydrocarbon free 50500 cc/min Zero Air
Hydrogen for fuel gas UHP 550 cc/min Hydrogen
DSC Air for air shield Clean and dry 100 cc/min Clean Dry Air
TGA Nitrogen or dry air as furnace gas
Clean and dry air or high purity N2
100 cc/min Clean Dry Air or Nitrogen
TOD Nitrogen carrier gas UHP, Zero Grade 300 cc/min Zero Nitrogen
CO2 Analyser Calibration air Clean dry, CO2 free/ hydrocarbon free
5501000 cc/min CO2 free air
other laboratory applications
Sample Prep Nitrogen for solvent evaporation
9599% 130 L/min Nitrogen
Auto-samplers Air for pneumatic controls
Clean and dry 28 L/min Clean Dry Air
Nitrogen for sample injector
UHP, Zero Grade 550 cc/min Zero Nitrogen
Circular Dichroism Nitrogen UHP, Zero Grade Zero Nitrogen
ELSD Nitrogen 98% 28 L/min Nitrogen or
Particle sizing by Laser Diffraction
Clean and dry air for nebulizing gas
Clean and dry air Clean Dry Air
-
12
SGEM 2006: SEction 12 [GaS GEnEratorS]196
Hydrogen Generators
Capable of generating a continuous source of UHP hydrogen gas from de-ionised water and electricity for applications such as:
GC-FID, NPD, FPD, TCD, ELCD, HALL, GC-carrier gas, THA
BenefitsContinuous supply of GC quality hydrogen gas on demand. No warm-up period
Improved productivity and chromatography results when using hydrogen as a carrier gas.
Ultra safe operation from patented seven mode failure protection system
Extended column service life with hydrogens lower elution temperatures
Improved safety and efficiency
No caustic solutions required
FeaturesAutomatic H2 leak detection
Self test fault diagnosis with visual and audible alarms
High capacity water tank
Filters offer protection against harsh lab environment
Compact design
No need for liquid electrolytes or caustic solutions
No costly palladium purifier replacements
Simple installation and operation
CE and UL approved
Hydrogen Generator selection chart (Single desiccant cartridge)
ModelFlow rate (cc/min) Purity %
Pressure (psi)
connections BSP H2 outlet
Voltage (Vac)
Electrical consumption
Dimensions (mm)
Weight (kg)Width Height Depth
20H 160 >99.999%* 07 bar (0100)
1/8 Swagelok 110230 125 W 342 456 437 24
40H 250 >99.999%* 07 bar (0100)
1/8 Swagelok 110230 125 W 342 456 437 24
60H 500 >99.999%* 07 bar (0100)
1/8 Swagelok 110230 125 W 342 456 437 24
* When used with oxygen / moisture trap
High Purity Hydrogen MD Generator selection chart (regenerative Micro Dryer)
ModelFlow rate (cc/min) Purity %
Pressure (psi)
connections BSP H2 outlet
Voltage (Vac)
Electrical consumption
Dimensions (mm)
Weight (kg)Width Height Depth
20H-MD 160 >99.9999%* 07 bar (0100)
1/8 Swagelok 110230 180 W 342 456 437 24
40H-MD 250 >99.9999%* 07 bar (0100)
1/8 Swagelok 110230 210 W 342 456 437 24
60H-MD 500 >99.9999%* 07 bar (0100)
1/8 Swagelok 110230 300 W 342 456 437 24
Laboratory Gas Generators
-
12
SGEM 2006: SEction 12 [GaS GEnEratorS] 197
Laboratory Gas Generators
Lc/MS nitrogen Generators
Designed to meet the gas flow, purity and pressure requirements of LC/MS instruments using proven pressure swing adsorption (PSA) technology.
Features and BenefitsDesigned in conjunction with instrument manufacturers - Ideally suited to nebulising, sheath and drying gas applications
Wide range of flow rates available - Total flexibility allowing single or multiple instruments to be supplied
Fully regenerative PSA technology - Reduced risk of gas contamination
Guaranteed consistent nitrogen purity - Improved instrument stability and greater reproducibility of results
Integral oil-free compressors - Fully secure supply no reliance on existing compressed air supplies
Soundproofed compressor box - Low compressor noise
Phthalate-free - Clean analyses
Compact design - Fits under bench
CE, UL and CRN approved - Peace of mind
Lc/MS nitrogen Generator selection chart
ModelFlow rate (cc/min) Purity %
connections BSP
Voltage (Vac)
Dimensions (mm)
Weight (kg)air inlet Gas outlet Width Height Depth
LCMS-12-1* 12 0.5 1/8 110/230 345 873 663 90
LCMS-15-0 15 0.5 1/4 1/8 110/230 510 705 559 89
LCMS-15-1* 15 0.5 1/8 110/230 510 705 826 129
LCMS-18-0 18 0.5 1/4 1/8 110/230 345 873 663 77
LCMS-20-0 20 1 1/4 1/8 110/230 510 705 559 89
LCMS-20-1* 20 1 1/8 110/230 510 705 826 129
LCMS-30-0 30 1 1/4 1/8 110/230 510 705 760 135
LCMS-30-1* 30 2 1/8 110/230 510 705 826 129
LCMS-40-0 40 1 1/4 1/8 110/230 510 705 760 135
* with integral compressor
-
12
SGEM 2006: SEction 12 [GaS GEnEratorS]198
nitrogen Generators
Capable of generating nitrogen gas from pre-filtered compressed air for applications such as:
ICP
ELSD
GC make up / carrier gas
XRD
Solvent evaporation
NMR
CD
BenefitsDesigned to meet specific analytical instrument gas purityand flow requirements
Uses reliable pressure swing adsorption technology (PSA)
no need for secondary purification
Constant flow of instrument grade nitrogen
improved consistency and reproducibility of results
improves laboratory efficiency
Economy mode option turns off compressor when nitrogen supply is not required
Simple Installation on or below bench top
Quick, easy servicing typically less than 10 mins every 6 months
nitrogen Generator selection chart
ModelsFlow rate (L/min) Purity
connections BSP
Voltage (Vac)
Dimensions (mm) Weight (kg)
air inletGas outlet Width Height Depth
Without compressor
With compressor
G1 0.55 10 ppm 1/8 1/8 110/230 345 842 413 52 56
0.75 10 ppm
G2 1.5 10 ppm 1/8 1/8 110/230 345 873 663 77 90
2 10 ppm
G3 2.5 100 ppm 1/8 1/8 110/230 345 873 663 71 83
4 0.1%
5 0.5%
7 1%
8 2%
G4 5 100 ppm 1/8 1/8 110/230 345 873 663 77 90
6 0.1%
10 0.5%
12.5 1%
14 2%
Laboratory Gas Generators
-
12
SGEM 2006: SEction 12 [GaS GEnEratorS] 199
Laboratory Gas Generators
Zero nitrogen and Dry air Generators
Suitable for applications such as:
GC-FID
THA
Zero nitrogen and Dry air Generator selection chart
ModelsFlow rate (L/min) Purity
connections BSP
Voltage (Vac)
Dimensions (mm) Weight (kg)
air inletGas outlet Width Height Depth
Without compressor
With compressor
Zero nitrogen
G5 1 10 ppm 1/8 1/8 110/230 345 842 413 51 55
combined nitrogen and Dry air
G6
N2: 0.6 10 ppm 1/8
1/8 110/230
345
842
413
54
58
Air: 1.5 -55C adp 1/8
G7
N2: 3 10 ppm 1/8
1/8 110/230
345
842
413
80
93
Air: 3 -55C adp 1/8
Dry air
G8 3 -55C adp 1/8 1/8 110/230 345 842 413 50 54
G9 6 -55C adp 1/8 1/8 110/230 345 842 413 50 54
-
12
SGEM 2006: SEction 12 [GaS GEnEratorS]200
Zero air Generators
By connecting to a compressed air supply, a zero air generator will remove hydrocarbons and methane, making it ideal for use with the following applications:
GC-FID, NPD, FDP
LC/MS
THA
Gas sensing
BenefitsContinuous flow of clean, dry air with ultra low residual methane content
Improved instrument performance through reduced baseline noise and improved stability
Cleaner air reduces frequency of instrument cleaning and re-calibrations
Simple installation connect to any clean, dry compressed air source
Improved safety no high pressure cylinders required
Improved lab efficiency 24 hour operation
FeaturesHigh performance catalyst and filtration system
Eliminates the main contaminants in your compressed air supply (HCs and CH4)
Purity
-
12
SGEM 2006: SEction 12 [GaS GEnEratorS] 201
Laboratory Gas Generators
clean Dry air Generators
These desiccant dryers are ideal for laboratory use, providing a constant flow of clean, dry compressed air for:
NMR, AA, GC, ATD
Rheometer
Sample prep
Auto samplers and more
FeaturesPoint of use installation provides clean and dry air where you need it
Quite operation
Compact and lightweight
Can be bench or wall mounted
Quick easy servicing
clean Dry air Generator Selection chart
Modelsoutput air Flow (L/min)
Dimensions (mm) Weight (kg)
DAS 1 70 422 x 149 11
DAS 2 115 500 x 149 13
DAS 3 182 616 x 149 16
DAS 4 227 692 x 149 18
DAS 5 295 847 x 149 20
DAS 6 340 906 x 149 23
DAS 7 453 1098 x 149 28
Max. working pressure 12 bar g (175 psi g)
Dewpoint -40C
Purity Non methane HCs
-
12 Gas Generators
SGEM 2006: SEction 12 [GaS GEnEratorS]202