Bleeding system for cooling water treatment · ELADOS® EMP for Water Treatment 05/2017...
Transcript of Bleeding system for cooling water treatment · ELADOS® EMP for Water Treatment 05/2017...
Product catalog Systems / Plants
Measuring Metering Systems Plants
Contents
Proportional metering system
1 Proportional metering device EMP Compact
Bleeding system for cooling water treatment
2 Bleeding unit CoolProtect
3 Bleeding unit Versatronic Cooling Water
Metering units
4 Metering unit with batch tank
5 Metering station
Compact Metering Device
ELADOS® EMP for Water Treatment
05/2017 EMP-Kompakt-II_e.doc 1
• For quantity-proportional metering in water post-treatment technology, tested by DVGW (German assoc. of gas and water experts)
• With contact water meter as proportional pulse generator
• With silent, electric motor driven diaphragm pump • Benefits of the EMP E60 pump
- Graphic display with user-friendly menu navigation - Metering monitoring via stroke signal output - Extensible functions via access code (pulse multiplication, pulse division, registration of operating and consumption data, calibration function)
The ELADOS® EMP compact metering devices are appliances designed for the posttreatment of potable water. They consist of contact water meter including metering valve and metering pump. The concentration needed may be selected via the metering pumps mechanical stroke adjustment
function. By coordinating the components of the EMP-program it is possible to combine compact metering devices for several applications, thus reaching delivery capacities between 0.2 l/h and over 750 l/h with nominal diameters (DN) between 20 and 150.
Technical data: Material no. 141277 141278 141279 Nominal diameter (mm): DN 20 / R 3/4 DN 25 / R 1 DN 40 R 1½ Nominal flow (m³/h): 2,5 6 10 Pump metering capacity (l/h): 1,4 1,4 2,5 Max. metering capacity. (cm³/pulse): 0,21 0,21 0,39 Max. metering back pressure (bar): 10 10 10 Pulse interval (l/pulse): 1 1 2 Max. concentration (ppm): 100 100 100 Connection thread G: R 1 R 1 1/4 R 2 Electric connection (V/Hz): 230 (50/60) 230 (50/60) 230 (50/60) Power input (W): 10,4 10,4 10,4 Protection type: IP 65 IP 65 IP 65
Compact Metering Device
ELADOS® EMP for Water Treatment
05/2017 EMP-Kompakt-II_e.doc 2
Dimensions:
DN20 (Material No. 141277)
DN25 (Material No. 141278)
DN40 (Material No. 141279)
Compact Metering Device
ELADOS® EMP for Water Treatment
05/2017 EMP-Kompakt-II_e.doc 3
Material No. 141277 141278 141279
Nominal width (mm): DN 20 / R 3/4 DN 25 / R 1 DN 40 R 1½
Length L (mm) without screw connection: 130 260 300
Length L1 (mm) (overall length) 222 365 447
Connection-thread G R 1 R 1 1/4 R 2
Connection-thread G1 R 3/4 R 1 R 1 1/2
Compact Metering Device
ELADOS® EMP for Water Treatment
05/2017 EMP-Kompakt-II_e.doc 4
Ordering data: Article Material No.
ELADOS® EMP Compact E60 V3014 PP 10 EP KE PP DN20 141277 E60 V3014 PP 10 EP KE PP DN25 141278 E60 V3025 PP 10 EP KE PP DN40 141279 Extent of supply:
1 contact compact water-meter with screw connection and ready-assembled metering valve, assembled metering pump with connection cable, fixing brackets for water-meter, ready-assembled metering line (approx. 500 mm length) including connecting elements and O-ring seals, 2 m metering line (PE) for use in case of on-wall installation, operating instructions.
ELADOS® EMP Compact
Accessories
05/2017 EMP-Kompakt-II_e.doc 5
Article Material No.
Suction lance D16 with empty signal report
SGL VCPVFP99GL000-0008-06-1SS-0525-9999
incl. of ball non-return valve, level-pre-warning-contact, 2 m connecting cable with connector and 2 m suction hose 6/8 Length: 525 mm Nominal width (pipe): 6 mm
Material Suction lance: PVC Valve ball: glass for chemical reservoir 20/30 l length 525 mm
249222
Suction lance D16 with double empty signal report
incl. of ball non-return valve, suction strainer, level-pre- warning-contact, zero-potential empty signal contact (level down = contact interrupted),hose connection material (4/6 mm, 6/8 mm, 6/12 mm) Material: PVC Seals: Viton B Ball: Glass Pipe diameter: 16 mm Suction tube: PE Connection cable: 3-pole connector incl. 5 m cable
for chemical reservoir 20/30 l length 540 mm
for chemical reservoir 60 l length 750 mm
for chemical reservoir 100 l length 970 mm
for chemical reservoir 200 l length1125 mm
249020
249021
249022
249023
ELADOS® EMP Compact
Accessories
05/2017 EMP-Kompakt-II_e.doc 6
Article Material No.
Adapter screw cap
for suction lance ø 16 mm can be screwed on 10 l and 20 l canister Thread pitch: 5 mm Threaded internal diameter: 50 mm Threaded external diameter: 55 mm
Adapter screw cap
for suction lance ø 16 mm can be screwed on 60-200 l chemical reservoir or 30 l canister Thread pitch: 5 mm Threaded internal diameter: 56 mm Threaded external diameter: 61 mm
Adapter cable for EMP II
between empty signal input plug suction lance EMP old and empty signal input EMP II/III
38619003
38619004
248201
Suction unit
with floating empty signal contact (empty = contact interrupted) consisting of: Bottom admission valve (PVDF), ceramic weight, float switch (PVC/PP), 5m connection cable with 4-pin plug and PE cover dome Suction unit for 4/6 mm hose Suction unit for 4/6 mm hose with "soft sealing" through O-ring
188461
288461
ELADOS® EMP Compact
Spare Parts
05/2017 EMP-Kompakt-II_e.doc 7
Spare parts: Metering pump EMP II, E60, 1.4 l/h (for 141277, 141278) 148070 2.5 l/h (for 141279) 148170
Pos Article Material No. 1 SDV PPEPKE 000 G 3/8 - G 3/8 – 99 Suction/pressure valve, PP/EPDM 248116 2 Connection set 3/8“ PP for hose 4/6, 6/8, 6/12 mm 248492 3 Valve cartridge, V3 EMP II EPKEPP 248435 4 Cover plate, PK-PP 54000188 5 Hexagon socket screw, M 5 x 40, DIN 912, V2A 413031026 6 Washer, B15 x 5.3 x 1.6, DIN9021, ISO7093, V2A 413501720 7 Venting screw, PP/EPDM 243078 8 Bellow 34800132 9 Transparent enclosure cover 34800120 10a Dummy plug, empty signal input 248186 11a Cover cap, control output 34800117 12a Dummy plug, control input 248187 10b Plug 4-poles, empty signal input 418463115 11b Plug 4-poles, control output 418463117 12b Plug 5-poles, control input 418463118 13 Wiring outlet 3-poles, 2 m 34860001
type V3014 type V3025
14 Diaphragm 34800134 34800253 15 Supporting disk 34000158 -- 16 Intermediate plate 34800133 34800150 17 Pump head PVDF 34800293 34800294
ELADOS® EMP Compact
Spare Parts
05/2017 EMP-Kompakt-II_e.doc 8
Article Material-No.
Contact water meter DN 20, G 1, 1 l / pulse (for 141260)
Contact water meter DN 25, G 1 ¼, 1 l / pulse (for 141274)
Contact water meter DN 40, G 2, 2 l / pulse (for 141275)
419901047
419901237
419901238
Contact water meter screw connection
Material: Brass for contact water meter DN 20 (G 1i – R ¾a) DN 25 (G 1¼i – R 1a) DN 40 (G 2i – R 1½a) Contact water meter screw connection with hole R 1/4 for metering valve
Material: Brass for contact water meter DN 20 (G 1i – R ¾a) DN 25 (G 1¼i – R 1a) DN 40 (G 2i – R 1½a)
415506343 415506344 415506349
415506331 415506332 415506334
ELADOS® EMP Compact
Spare Parts
05/2017 EMP-Kompakt-II_e.doc 9
Article Material-No.
Mounting bracket (for 141277)
Mounting bracket MS Washer 5.5 x 10 x 1, V2A Hexagon nut M5, V2A Pipe clamps (for 141278)
Pipe clamp D40 – 45 mm, M8, V2A Pipe clamp D48 – 52 mm, M8, V2A Pipe clamps (for 141279)
Pipe clamp D48 – 52 mm, M8, V2A Spacer bolt Brackets
Mounting / Wall bracket (for 141277) Mounting plate (for 141278, 141279), VA 1.4301 Wall bracket (for EMP II pump), PP
34800307 413500360 413200007
415014026 415014027
415014027 413502501
34800306
34127701
207002
ELADOS® EMP Compact
Spare Parts
05/2017 EMP-Kompakt-II_e.doc 10
Metering valves - code 1. Valve designation
DVM = metering valve with metering pipe DVO = metering valve without metering pipe
2. Screw-in part material MS = brass VA = stainless steel
3. Valve body material PP = PP PV = PVDF
4. Sealing material EP = EPDM
5. Valve ball / conical nipple material GL = glass 99 = without balls
6. Valve spring pressure 010 = 1.0 bar 018 = 1.8 bar
7. Thread screw-in side G ¼ G ½
8. Thread connecting side G 3/8
9. Connection 21 = set for hose 4/6, 6/8, 6/12 52 = set for hose 4/6 (cutting ring)
Article Material-No.
DVM MS PV EP 99 010 G 1/4 – G 3/8 – 52 243016 (for 141277)
DVM VA PP EP GL 018 G 1/4 – G 3/8 – 21 248053 (for 141277 and 141278)
DVM MS PV EP 99 010 G1/4 G3/8 52
ELADOS® EMP Compact
Wearing Parts
05/2017 EMP-Kompakt-II_e.doc 11
Set of wearing parts (complete)
consisting of 1 piece each:
• Suction valve with hose connection material (1) • Pressure valve with hose connection material (2) • Venting screw (3) • Diaphragms (4) • Supporting ring (5, not for type V3025) • Bellow (6)
Article Code Material-No.
Wearing part set EMP II V3014PPEPKE 248462 EMP II V3025PPEPKE 248471
1. Pump type (pump capacity)
V3014 = 1.4 l/h V3025 = 2.5 l/h
2. Valve material PP = PP
3. Sealing material EP = EPDM
4. Valve ball material KE = ceramics
Wearing part set EMP II
V3014 PP EP KE
3 1, 2
4 5 6
CoolPROTECT
Control Equipment
03/2014 Coolprotect_e.doc 1
Ready-to-connect, preassembled bleeding system with programmable control device for optimum cooling water treatment. • Conductivity-dependent bleeding control • Optional timer-controlled biocide metering • Maintenance-free inductive conductivity measurement • Forced recirculation according to VDI regulation 6022 • Real time module with 2 independent day and week
clock timers • High efficiency due to adjustable
interlocking of simultaneous bleeding and biocide metering)
• Integrated acoustic alarm signal • Simple, menu-assisted operation in plain text • Definable access code Cooling tower bleeding
In a cooling tower, a continuous increase in the minerals dissolved in the water takes place due to the continual evaporation of the water (bleeding). CoolPROTECT continually controls the conductivity and the bleeding grade of the cooling tower water. If the measured value exceeds a preset upper limit W+, deconcentration of the water is introduced by transfer of water from the cooling circuit into the discharge channel. The consequent reduction in the level of the cooling water is sensed by a level control device, which controls the introduction of fresh feed water. This supply of fresh feed water causes the concentration to decrease and the conductivity reduces. If the conductivity now falls below a preset lower limiting value W- the deconcentration process is terminated. The water in the cooling circuit continues to be subject to the process of salination. When the upper limiting value W+ is again reached, the deconcentration process restarts.
Biocide metering
Microbiological cultures form in the cooling water under conditions that are favourable to this phenomenon (high temperatures, high concentration of minerals).
In order to protect the system and preclude any health risks to humans, the cooling water circuit must be dosed with a germicide product at regular intervals. With CoolPROTECT it is possible to carry out time-controlled biocide metering intervals. The duration of the metering and reaction time is arbitrary. The bleeding controller is inhibited during the metering and reaction time. The current operating status is displayed on the screen in plain text. You can also activate a pre-bleeding function. This means that if, when biocide dosing is triggered by the timer, the conductivity value is above the lower bleeding threshold (W), bleeding has priority over biocide dosing.
Circulation control
In order to act against contamination resulting from water circuits that are periodically deactivated, optional communication between CoolPROTECT and the cooling water system control system can be established. This control system independently activates the water circuit circulation pump even if the cooling tower is switched off. It then starts biocide dosing after a settable circulation time has passed.
CoolPROTECT
Control Equipment
03/2014 Coolprotect_e.doc 2
Technical data (conductivity measuring unit):
Dimensions: 360 x 110 x 160 mm (w ∗ d ∗ h)
Ambient temperature: max. 45° C
Weight: approx. 4.8 kg
Power supply: 230 V AC, 15 VA 50/60 Hz
Protection type: IP 65
Protection class: III
Control electronics
Display unit:
Two-line, 16 digit LC Display
Control functions: Conductivity controller Time control
Inputs: − Conductivity probe, inductive − Temperature sensor, conductivity − Enable contact
Outputs: − Change-over contact for alarms − Acoustic alarm, 24 V AC (buzzer) − Change-over contact for bleeding − Change-over contact for biocide control − Potential-free changeover contact for pre-circulation (cooling water
circulation pump)
Conductivity measurement: Measuring range: Accuracy: Repeatability:
0 - 3000 µS/cm in steps of 1 µS/cm ±10% of the set conductivity value < 3000 µS/cm (We recommend that the devices are operated above 150 µS/cm) Amplitude fluctuation max. ± 2.5% of the set value
Timing: Real time clock with battery buffer (lifetime > 10 years) Notice: To guarantee the newest state of our products, we reserve the rights for single technical
changes.
CoolPROTECT
Control Equipment
03/2014 Coolprotect_e.doc 3
Ordering data: Article Material-No.
CoolPROTECT basic system
Bleeding unit CoolPROTECT with integrated timer for biocide metering pre-assembled on a mounting plate (500 x 720 mm)
Bleeding unit CoolPROTECT with integrated timer for biocide metering and pre-circulation pre-assembled on a mounting plate (500 x 720 mm)
Extent of supply: CoolProtect conductivity measuring
unit (1)
Manual diaphragm valve (2)
Conductivity measuring probe (3)
Motor driven ball cock 230 V (4)
Test portion cock (5)
on request
on request
CoolPROTECT options
on request
Option 1 Metering valve 1 for biocide metering, ready-assembled
Option 2 Metering valve 2 for metering of a 2nd biocide or a anticorrosive, ready-assembled
Option 3 Manual diaphragm valve on inlet side
Option 4 Filter in front of drain valve, DN 20, PVC, 0.5 mm
Option 5 Contact water meter with pulse output 1 pulse/liter
Option 6 Manometer 0-10 bar
Option 7 Orifice (-30 %), on outlet side
Option 8 Unit in a GFK cabinet with heating
Option 9 Components for biocide metering (see page 4)
1
5
4
3
2
3 5
1
4 6
7
2
8
CoolPROTECT
Control Equipment
03/2014 Coolprotect_e.doc 4
Article Material-No. Components for biocide metering on request for self installation by the customer For removal of standard original containers
10-60 liter.
Existing of:
1 diaphragm metering pump EMP II E60
1 wall bracket for metering pump EMP II
1 suction pipe D16, length: 750 mm
1 suction pipe adapter
5 m PE-hose 4/6 mm (ID/AD)
Components for biocide metering (degassing products) for self installation by the customer
on request
For removal of standard original containers 10-60 liter.
Existing of:
1 self-venting diaphragm piston pump EMP KKS E60
1 wall bracket for metering pump EMP KKS
1 suction pipe D32, length: 750 mm with return connection
1 suction pipe adapter
5 m PTFE-hose 4/6 mm (ID/AD)
CoolPROTECT
Control Equipment
03/2014 Coolprotect_e.doc 5
Article Material-No. Metering unit for biocide metering 75 liter on request Ready for connection metering unit
Existing of:
1 diaphragm metering pump EMP II E60 mounted on a container
1 metering product container PE, 75 l, Ø 460 mm, height 630 mm
1 suction pipe assembled and connected 1 level switch with level pre-warning and empty signal
assembled and connected
5 m PE-hose 4/6 mm (ID/AD)
Metering unit for biocide metering 75 liter (for
degassing products) on request
Ready for connection metering unit Existing of:
1 self-venting diaphragm piston pump EMP KKS E60
1 metering product container PE, 75 l, Ø 460 mm, height 630 mm
1 suction pipe assembled and connected 1 level switch with level pre-warning and empty signal
assembled and connected
5 m PTFE-hose 4/6 mm (ID/AD)
CoolPROTECT
Spare Parts
03/2014 Coolprotect_e.doc 6
Article Material-No.
CoolPROTECT control unit 255159
CoolPROTECT incl. timer for biocide metering 255155
CoolPROTECT incl. timer and pre-circulation 255166
Conductivity measuring probe, PP, with counter nut and cable 3 m with plug
287407
Conductivity measuring probe, PP, with counter nut and cable 6 m with plug
287408
Adapter PP for conductivity measuring probe CoolProtect to be installed in PVC flow fitting
38740131
O-ring EPDM 25.8 x 3.53 417001981
Versatronic
Cooling Water Treatment
11/2019 Versatronic-Kuehlwasser_e.doc 1
Supports the hygienic operation of evaporation coolers as per VDI 2047, sheet 2 resp. 42 federal regulations for emission protection law
Large illuminated graphic display
Simple operation by clear arranged menu guidance
Bleeding control of up to three cooling towers is possible
Additional monitoring measurements like pH or Redox can be integrated
Optional: Integrated screen recorder for data recording
The Versatronic cooling water allows fully automatic desalination control and timer-controlled biocide dosing of up to three cooling towers. If the device is only designed for one or two cooling towers, two weekly timers can also be set per measuring channel for the dosing of two different biocides.
The Versatronic also includes a communication function to the circulation pump of the cooling tower. Logic links between the functions of bleeding, biocide dosing and circulation control provide adequate process reliability.
Functions:
Adjustable interlocking between biocide dosing and bleeding (preferred bleeding)
Weekly timer with up to 4 dosing points per day (max. 28 per week) for biocide dosing, dosing duration and application time per dosing time freely selectable
Communication with the circulation pump of the cooling circuit (control gives a running command to the circulating pump if it is not running, after starting the circulation, bleeding or biocide dosing remain blocked for an adjustable time)
Selectable conductivity measuring principle (inductive or conductive measurement)
Additional measurement (incl. control output) integrable
Standard signal output (0/4 - 20 mA) for each measuring channel
Option: Integrated screen recorder for data recording and visualization
Option: Current screen display of the device on the PC/laptop via Ethernet interface (integrated web browser)
Versatronic
Cooling Water Treatment
11/2019 Versatronic-Kuehlwasser_e.doc 2
Technical data:
Bleeding inductive Default setting display range: 0 – 5000 μS/cm Default setting W+: 1800 μS/cm Default setting Ws: 1700 μS/cm Default setting W-: 1600 μS/cm Bleeding conductive
(electrode measurement) Default setting display range: 0 - 500 µS/cm Default setting W+: 180 μS/cm Default setting Ws: 170 μS/cm Default setting W-: 160 μS/cm Biocide timer Weekly timer, up to 4 dosing points per day selectable Dosing time: 0 – 23 h 59 min 59 s Application time: 0 – 23 h 59 min 59 s
pH measurement Default setting display range: 0 - 14 pH Preset setpoint: 7 pH Redox measurement Default setting display range: 0 - 500 mV Preset setpoint: 200 mV Outputs per measuring channel Bleeding: 3 make contacts Additional measurement: 1 make contact Default setting analog outputs: 4 - 20 mA
Display of the Versatronic bleeding device
1 Name of measuring channel
2 Reading
3 Switch point bleeding ON
4 Switching point pre-bleeding on
5 Switch point bleeding OFF
6 Temperature of cooling water
7 Current status of cooling water treatment
8 Calibration timer expired (perform calibration!)
9 Not approved (control output disabled)
10 Biocide dosing flag
11 Circulation flag
12 Nominal value controller additional measurement
13 Additional temperature measurement
14 Switching state output additional measurement (output active)
Versatronic
Cooling Water Treatment
11/2019 Versatronic-Kuehlwasser_e.doc 3
Dimensions:
495
720
Versatronic
Cooling Water Treatment
11/2019 Versatronic-Kuehlwasser_e.doc 4
11, 12, 13
Complete device:
Article/name Material No.
Versatronic Cooling Water basic device auf Anfrage
Bleeding device Versatronic Cooling Water with pre-circulation control pre-assembled on a mounting plate (500 x 720 mm)
Extent of supply: Versatronic Cooling Water conductivity measuring unit (1)
Manual diaphragm valve (2)
Conductivity measuring probe (3)
Motor driven ball cock 230 V (4)
Test portion cock (5)
on request
Versatronic Cooling Water options
on request
Option 1 Metering valve 1 for biocide metering, ready-assembled
Option 2 Metering valve 2 for metering of a 2nd biocide or a anticorrosive, ready-assembled
Option 3 Manual diaphragm valve on inlet side
Option 4 Manometer 0-10 bar
Option 5 Orifice (-30 %), on outlet side
Option 6 Filter in front of drain valve, DN 20, PVC, 0.5 mm
Option 7 Contact water meter with pulse output 1 pulse/litre
Option 8 Unit in a GFK cabinet with heating
Option 9 Motor diaphragm valve instead of motor driven ball cock
Option 10 additional pH measuring incl. probe, ready-assembled
Option 11 Profibus interface
Option 12 Ethernet interface
Option 13 Screen recorder
1
5
4
3
2
3
1
4
2
1009
5
8 75
9
6
Versatronic Cooling Water Treatment
Spare parts measuring and control device
11/2019 Versatronic-Kuehlwasser_e.doc 5
Ordering data single components:
Article Article no.
Basic unit
Versatronic basic unit 155201
incl. operating instructions
Measuring module
Measuring module Plug-in card Ci (inductive conductivity) 255250
Measuring module Plug-in card Cr (conductive conductivity)
255251
Measuring module Plug-in card pH/Redox 255252
Input Plug-in card
Plug-in card, universal input 255253
Plug-in card, binary input (3 make contacts) 255254
Output Plug-in card
Plug-in card, analog output (0/4 - 20 mA) 255255
Plug-in card, binary output (1 change-over contact) 255256
Plug-in card, binary output (2 make contacts) 255257
Plug-in card, binary output (2 x PhotoMOS) 255258
Plug-in card, binary output (1 x TRIAC) 255259
Plug-in card, power supply +/-5 V, 24 V 255260
Interface Plug-in card
Plug-in card, Profibus-DP interface 255261
Plug-in card, Ethernet interface 255262
Versatronic Cooling Water Treatment
Spare parts measuring and control device
11/2019 Versatronic-Kuehlwasser_e.doc 6
Article Article no. USB host socket 255263
Ethernet RJ-45 plug for self-assembly 255266
Panel mounting set 255267
Cable gland set Versatronic 255268
Resistor box for Ci basic adjustment/calibration adapter 255269
USB cable with plug USB/A - USB/B, length: 3 m 255273
Software
Setup software Versatronic (CD) 255264
Software PCA 3000 255270
Software PCC 255271
Function extension
Unlock code for registration function 255265
Versatronic Cooling Water Treatment Spare parts / accessories
Inductive Conductivity Measurement
11/2019 Versatronic-Kuehlwasser_e.doc 7
Inductive conductivity measurement probes with integrated temperature sensor Construction: Oval spherical cap, streamline-shaped with 8 mm meter flume
diameter Material: PVDF
Dimensions: 39 x 50 (Ø h) Pressure resistance: PN = 10 bar at 20 °C Temperature resistance: max. 120 °C Temperature sensor: PT100 Time of response of temperature sensor in measurement cell: approx. 30 s (90 % value) with stainless steel sensor Material sensor's protecting tube: Stainless steel, 1.4571 Sealing element: O-ring, EPDM 281 Length connection cable: 10 m Type of lead: 7-pin special measurement lead Measuring lead connection: prefabricated for terminal connection
Article
Material No.
Conductivity measuring probe as above, with adapter for PP flow fitting or PVC flow fitting
255202
Measuring probe material: PVDF Adapter material: PVDF
Calibration adaptor for conductivity basic adjustment with simulation resistances for five measuring ranges
2551269
Flow fitting Material: PVC Temperature resistance: up to 50 °C Connections: d40 adhesive muffs
287514
Versatronic Cooling Water Treatment Spare parts / accessories
Conductive Conductivity Measurement
11/2019 Versatronic-Kuehlwasser_e.doc 8
Article
Material No.
Conductive conductivity measurement probe as described above installed in PVC flow fitting seat Temperature: max. 55 °C Connections: d 32 adhesive muffs
255143
Calibration box for bleeding (conductive) with simulation resistances for the measurement ranges 0 ... 5, 0 ... 50, 0 ... 500 µS/cm
255199
Versatronic Cooling Water Treatment Spare parts / accessories
pH / Redox / Temperature Measurement
11/2019 Versatronic-Kuehlwasser_e.doc 9
Article
Material No.
pH-Combination Electrode with screw-in thread PG 13.5 and plug-in screw connection, glass shaft = 120 mm, Ø = 12 mm, collector Ag/AgCI, sintered.
pH-Combination Electrode with dirt-repelling PTFE-circular diaphragm pH range: 0 - 12 Temperature range: -15 °C ...+80 °C Pressure: up to 6 bar Minimum conductivity: 100 µS/cm
418853008
Redox Combination Electrode with screw-in thread PG 13.5 and plug-in screw connection, glass shaft Ø = 12 mm, L = 120 mm, platinum electrode, Ag/AgCI sintered collector, in KCI gel, ceramic diaphragm Temperature up to approx. 80 °C
418853010
Temperature sensor Pt 100 with PG 13.5 screw-in thread and screw connection glass shaft Ø = 12 mm, L = 120 mm Temperature up to 100 °C
418853004
Versatronic Cooling Water Treatment Spare parts / accessories
pH / Redox / Temperature Measurement
11/2019 Versatronic-Kuehlwasser_e.doc 10
Article
Material No.
Impedance converter We recommend the installation of the impedance converter in order to prevent negative influences on the measurement signal of pH-measurement due to electrical fields of near live wires, dirt or moistures. The impedance converter is also used to short-out higher distances (more than 10 m) between measurement chain and measurement unit. The impedance converter is screwed onto the measurement chain directly. The delivery performance includes also a battery (live approx. 5 years).
Internal resistance: Ri 5 Permitted surrounding temp.: -10...+50 °C Permitted storing temp..: -10...+60 °C Housing: PVC Length: 108 mm Weight: 0.09 kg
418853005
Connection cable with rotating matching plug for Redox measurement Length 2 m Length 5 m Length 10 m Length 20 m
418853101 418853102 418853103 418853104
Connection cable (doubly shielded) with rotating matching plug for pH-measurement
Length 5 m 418853106 Length 10 m 418853107 Length 15 m 418853108 Length 20 m
418853109
Connection cable (3-conductor connection) with rotating matching plug for temperature-measurement Length 10 m
255197
Connection cable (doubly shielded) with rotating matching plug for pH electrode with integrated temperature sensor Pt 100 Length 10 m
on request
Versatronic Cooling Water Treatment Spare parts / accessories
pH / Redox / Temperature Measurement
11/2019 Versatronic-Kuehlwasser_e.doc 11
Article
Material No.
Buffer solutions pH 4,01 20 ml 418853125 pH 7,00 20 ml 418853126 pH 9,21 20 ml 418853127 pH 4,01 1 l 418853121 pH 7,00 1 l 418853122 pH 9,21 1 l 418853123
Redox-buffer solution 468 mV 250 ml 418853124
Detergent for Combination pH and ORP/Redox Electrodes
418853128
Pepsin-hydrochloric acid solution 250 ml
Angle seat flow fitting for Combination pH or ORP/Redox Electrodes Material: transparent PVC Operational temperature: max. 60 °C Pressure resistance: 10 bar (at 20 °C) 5 bar (at 40 °C) 1 bar (at 60 °C) Nominal diameter: DN 25, 1" (d = 32) Connections: d32 adhesive muffs
418853202
Flow fitting for 3 measuring probes Material: PP Angle support: stainless steel Operational temperature: max. 80 °C Pressure resistance: 10 bar (at 20 °C) Connection thread: G1/2 Hose connection: 6/12 mm (int. Ø/ext. Ø)
418853213
Versatronic Cooling Water Treatment Spare parts / accessories
General
11/2019 Versatronic-Kuehlwasser_e.doc 12
Article
Material No.
Motor driven ball cock Type: closed when currentless Nominal voltage: 230 V AC 50/60 Hz Nominal width DN20 Material Armature: brass nickel-plated Closing body and spindle: stainless steel Spindle seal: O-ring, EPDM Ball seat: PTFE, O-ring Viton
on request
Metering Unit with
Batch Tank
11/2019 Dosierstationen-mA-Eco_e.doc 1
Batch tank from 40 - 200 l with sophisticated design for easy installation of the components
On request with space-saving sump
Metering pumps with stepper motor technology in different electronic versions from 5 l/h to 120 l/h
Easy to configure and adapt to operational requirements thanks to modular design
Wide range of accessories
User-friendly, low-maintenance and cost-effective
The metering unit with batch tank was developed specifically for industrial water treatment and chemical plant construction for the safe storage and dispensing of liquid chemicals. Particular emphasis was placed on plant safety and ease of use for the operating personnel. Faced with the increasingly stringent provisions of the German Water Resources Act (WHG) and stricter safety guidelines for employee protection, these metering stations offer an economic solution for supplying chemicals that must be metered.
The individual components are easy to combine, which enables the system to be optimally adjusted to meet operational requirements with metering performance levels of up to 120 l/h. Complete metering stations can be assembled quickly and cost-effectively either in advance at the manufacturing plant or, thanks to the system’s modular design, on site using individual components.
Metering Unit with
Batch Tank
11/2019 Dosierstationen-mA-Eco_e.doc 2
Overview:
Metering valve (9) Oval gear meter (8) Multifunction valve (7) Metering pump (1) Level monitoring (4) Installation (11)
Metering line (10)
Stirring tool (6)
Container (2)
Suction pipe (3)
Sump (5)
Metering Unit with
Batch Tank
11/2019 Dosierstationen-mA-Eco_e.doc 3
Pos. 1) Diaphragm metering pump Article Pump code* Material No. EcoPro PP/FKM EcoPro-ES-00510X-PFC-00S-1S-S0 15201000 EcoPro-ES-01110S-PFC-00S-1S-S0 15202000 EcoPro-ES-03003S-PFC-00S-1S-S0 15203000 EcoPro-ES-05010M-PFC-00S-1S-S0 15205000 EcoPro-ES-12003M-PFC-00S-1S-S0 15206000
PP/EPDM EcoPro-ES-00510X-PEC-00S-1S-S0 15201100 EcoPro-ES-01110S-PEC-00S-1S-S0 15202100 EcoPro-ES-03003S-PEC-00S-1S-S0 15203100 EcoPro-ES-05010M-PEC-00S-1S-S0 15205100 EcoPro-ES-12003M-PEC-00S-1S-S0 15206100
PVDF/FKM EcoPro-ES-00510X-DFC-00S-1S-S0 15201300 EcoPro-ES-01110S-DFC-00S-1S-S0 15202300 EcoPro-ES-03003S-DFC-00S-1S-S0 15203300 EcoPro-ES-05010M-DFC-00S-1S-S0 15205300 EcoPro-ES-12003M-DFC-00S-1S-S0 15206300
PVDF/EPDM EcoPro-ES-00510X-DEC-00S-1S-S0 15201400 EcoPro-ES-01110S-DEC-00S-1S-S0 15202400 EcoPro-ES-03003S-DEC-00S-1S-S0 15203400 EcoPro-ES-05010M-DEC-00S-1S-S0 15205400 EcoPro-ES-12003M-DEC-00S-1S-S0 15206400 EcoAdd PP/FKM EcoAdd-ES-00510X-PFC-00S-1S-S0 15221000 EcoAdd-ES-01110S-PFC-00S-1S-S0 15222000 EcoAdd-ES-03003S-PFC-00S-1S-S0 15223000 EcoAdd-ES-05010M-PFC-00S-1S-S0 15225000 EcoAdd-ES-12003M-PFC-00S-1S-S0 15226000
PP/EPDM EcoAdd-ES-00510X-PEC-00S-1S-S0 15221100 EcoAdd-ES-01110S-PEC-00S-1S-S0 15222100 EcoAdd-ES-03003S-PEC-00S-1S-S0 15223100 EcoAdd-ES-05010M-PEC-00S-1S-S0 15225100 EcoAdd-ES-12003M-PEC-00S-1S-S0 15226100
PVDF/FKM EcoAdd-ES-00510X-DFC-00S-1S-S0 15221300 EcoAdd-ES-01110S-DFC-00S-1S-S0 15222300 EcoAdd-ES-03003S-DFC-00S-1S-S0 15223300 EcoAdd-ES-05010M-DFC-00S-1S-S0 15225300 EcoAdd-ES-12003M-DFC-00S-1S-S0 15226300
PVDF/EPDM EcoAdd-ES-00510X-DEC-00S-1S-S0 15221400 EcoAdd-ES-01110S-DEC-00S-1S-S0 15222400 EcoAdd-ES-03003S-DEC-00S-1S-S0 15223400 EcoAdd-ES-05010M-DEC-00S-1S-S0 15225400 EcoAdd-ES-12003M-DEC-00S-1S-S0 15226400 * Pump code legend see chapter Metering / EcoPro/EcoAdd.
Metering Unit with
Batch Tank
11/2019 Dosierstationen-mA-Eco_e.doc 4
Article
Material No.
Pos. 2) Metering container
Metering container 40 l, LLDPE 460 mm x height: 490 mm 34124001
Metering container 75 l, LLDPE 460 mm x height: 630 mm 34124002
Metering container 140 l, LLDPE 600 mm x height: 660 mm 34124003
Metering container 200 l, LLDPE 600 mm x height: 880 mm 34124004
Pos. 3) Suction pipe
Suction pipe ECO, G3/8 NW8, length: 560 mm, 40 l (for ECO metering pump 5 and 11 l/h)
241251
Suction pipe ECO, G3/8 NW8 length: 700 mm, 75/140 l (for ECO metering pump 30 and 50 l/h)
241252
Suction pipe ECO, G3/8 NW8 length: 950 mm, 120 l (for ECO metering pump 120 l/h)
241253
Pos. 4) Level monitoring
for 40 l container, 16 mm, length: 435 mm 418264039
for 75/140 l container, 16 mm, length: 605 mm 418264040
for 200 l container, 16 mm, length: 805 mm 418264041
Metering Unit with
Batch Tank
11/2019 Dosierstationen-mA-Eco_e.doc 5
Article
Material No.
Pos. 5) Sumps, PE
500 mm, height: 540 mm for 40/75 l container
419800427
650 mm, height: 540 mm for 120 l container
419800428
655 mm, height: 730 mm for 200 l container
419800429
Pos. 6) Mixer / stirring tool
Hand mixer PVC length: 1200 mm (can be cut to length on request)
419800023
Hand mixer for 40/75/140 l container on request
Hand mixer for 200 l container on request
Stirring tool motor 230 V, 0.12 kW, 750 1/min 415708767
Stirring tool motor 3/PE 400/230 V, 0.06 kW, 750 1/min 415708768
Stirring tool shaft, V4A, d = 11 mm, l = 400 mm 415708763
Stirring tool shaft, V4A, d = 11 mm, l = 550 mm 415708765
Stirring tool shaft, V4A, d = 11 mm, l = 600 mm 415708764
Stirring tool shaft, V4A, d = 11 mm, l = 800 mm 415708766
Mixing propeller 100 PVDF 415708761
Metering Unit with
Batch Tank
11/2019 Dosierstationen-mA-Eco_e.doc 6
Article
Material No.
Pos. 7) Multifunction valve
for pumps up to 11 l/h:
MFV PV FP 050 G 3/8 – G 5/8 – 21* 249240
MFV PV EP 050 G 3/8 – G 5/8 – 21* 249260
MFV PV FP 100 G 3/8 – G 5/8 – 21* 249241
MFV PV EP 100 G 3/8 – G 5/8 – 21* 249261
for pumps up to 30 l/h:
MFV PV FP 050 G 5/8 – G 5/8 – 06* 249242
MFV PV EP 050 G 5/8 – G 5/8 – 06* 249262
MFV PV FP 100 G 5/8 – G 5/8 – 06* 249243
MFV PV EP 100 G 5/8 – G 5/8 – 06* 249263
for pumps up to 50 l/h:
MFV PV FP 050 G 1¼ – G 5/8 – 07* 249244
MFV PV EP 050 G 1¼ – G 5/8 – 07* 249264
MFV PV FP 100 G 1¼ – G 5/8 – 07* 249245
MFV PV EP 100 G 1¼ – G 5/8 – 07* 249265
* Type key legend see chapter EcoPro/EcoAdd
Pos. 8) Oval gear meter
OGM PLUS 00112VCFPPKKE-G1/8i-99-0001 (for 11 l/h)
280041
OGM PLUS 00540VCFPPKKE-G1/4i-99-0005 (for 50 l/h)
280043
OGM PLUS 01200VCFPPKKE-G3/4i-99-0010 (for 120 l/h)
280044
Connecting adapter OGM 00112 1/8-3/8-PV FP-21 280080
Connecting adapter OGM 00540 1/4-5/8-PV FP-50 280081
Connecting adapter OGM 01200 3/4-5/4-PV FP-07 280082
Connection cable OGM PLUS - EcoAdd, 5 m 252084
Connection cable OGM PLUS - SPS, 5 m 418439006
Metering Unit with
Batch Tank
11/2019 Dosierstationen-mA-Eco_e.doc 7
Article
Material No.
Wall-mounting bracket for OGM type 00112/00540/01200 280084
Pos. 9) Metering valve*
for pumps up to 11 l/h:
DVP PFC-H03-G1/4-G3/8-045-99 252150
DVP PEC-H03-G1/4-G3/8-045-99 252151
DVP DFC-H03-G1/4-G3/8-045-99 252153
DVP DEC-H03-G1/4-G3/8-045-99 252154
DVP PFC-003-G1/2-G3/8-045-99 252155
DVP PEC-003-G1/2-G3/8-045-99 252156
DVP DFC-003-G1/2-G3/8-045-99 252157
DVP DEC-003-G1/2-G3/8-045-99 252158
for pumps up to 50 l/h:
DVP PFC-007-G1/2-G5/8-045-99 252177
DVP PEC-007-G1/2-G5/8-045-99 252178
DVP DFC-007-G1/2-G5/8-045-99 252179
DVP DEC-007-G1/2-G5/8-045-99 252180
Note: Please order connection material for hose and pipe connection separately (see chapter EcoPro/EcoAdd in section metering).
* Type key legend see chapter EcoPro/EcoAdd
Metering Unit with
Batch Tank
11/2019 Dosierstationen-mA-Eco_e.doc 8
Article
Material No.
for pumps up to 120 l/h:
DVP PFC-008-G3/4-G11/4-150-99 252184
DVP PEC-008-G3/4-G11/4-150-99 252185
DVP DFC-008-G3/4-G11/4-150-99 252186
DVP DEC-008-G3/4-G11/4-150-99 252187
Note: Please order connection material for hose and pipe connection separately (see chapter EcoPro/EcoAdd in section metering).
Pos. 10) Metering lines
for pumps up to 11 l/h:
PE hose 4/6 mm 417400301
PE hose 6/8 mm 417400310
PTFE hose 4/6 mm 417400215
PTFE hose 6/8 mm 417400224
for pumps up to 50 l/h:
PVC-fabric 6/12 mm 417400123
PVC-fabric 10/16 mm 417400126
for pumps up to 120 l/h:
PVC-Gewebeschlauch 12/21 mm 417400127
PVC-Gewebeschlauch 19/27 mm 417400131
Note: We explicitly point out that PVC fabric tubes have a limited lifetime if alkaline chemicals will be used. To avoid damage for your staff and your company the tubes have to be exchanged at least every 6 months. In case of non-compliance we exclude all kinds of liability and responsibility.
Pos. 11) Installation incl. small parts
Installation of pump, suction pipe, level monitoring incl. electrical connection
Hand mixer installation
Stirring tool installation
Metering Consoles
07/2013 Dosierkonsolen_e.doc 1
• Available as wall bracket or stand-alone version with drip tray • Minimum costs for installation and startup • Optimal adaption to process parameters thanks to modular system • Wide range of applications
Economic and environmentally responsible use of liquid chemicals demands defined, safe and functional metering. Thanks to a universal modular system the metering consoles provide multiple possibilities to meet the specific metering requirements.
By combining the comprehensive EMP pump range with the corresponding accessories and containers almost any metering task can be realized.
Metering Consoles
EMP KKS / EMP II / EMP III
07/2013 Dosierkonsolen_e.doc 2
Examples of wall brackets
2 EMP KKS pumps, 2 EMP II pumps, 1 EMP III pump 2 EMP III pumps 1 metering line 2 metering lines 1 metering line, OGM
Examples of stand-alone versions
2 EMP KKS pumps 2 EMP II pumps 2 EMP III pumps 2 metering lines 2 metering lines, 2 OGM 2 metering lines
Metering Consoles
EMP KKS / EMP II / EMP III
07/2013 Dosierkonsolen_e.doc 3
Technical data:
EMP KKS EMP II EMP III Metering capacity [l/h]
0,2 0,5 0,9 1,4 1,4 2,5 4,8 4,3 7,2 7,2 11,2 24 16 25 54 Metering back pressure[bar] 10 10 4 10 6 10 5 2 10
Metering accuracy: < +/- 3% Suction height [mWs]: 2 Ambient temperature [°C]: + 5 to + 40
Power supply [V / Hz]: 230 / 50 Safety type: IP 65 IP 55 Weight [kg] wall bracket with 2 pumps: approx. 10 approx. 10 approx. 12 approx. 21 Weight [kg] stand bracket with 2 pumps: approx. 20 approx. 20 approx. 22 approx. 31
Wall bracket consisting of:
Version with one pump Version with two pumps 1 wall bracket PP Dimensions with EMP KKS/II (h ∗ w ∗ d): 800 x 600 x 304 mm Dimensions with EMP III: 800 x 600 x 363 mm
1 wall bracket PP Dimensions with EMP KKS/II (h ∗ w ∗ d): 800 x 600 x 304 mm Dimensions with EMP III: 800 x 600 x 363 mm
1 diaphragm metering pump 2 diaphragm metering pumps 1 pump bracket 2 pump brackets 1 terminal box 1 terminal box 2 manual diaphragm non-return valves 3 manual diaphragm non-return valves (4 valves on
the version with 2 metering lines) Assembly of components, piping and wiring on the unit included
Assembly of components, piping and wiring on the unit included
Stand-alone version consisting of:
Version with one pump Version with two pumps 1 stand bracket with drip tray PP / VA Dimensions: 1750 x 660 x 550 mm (h ∗ w ∗ d)
1 stand bracket with drip tray PP / VA Dimensions: 1750 x 660 x 550 mm (h ∗ w ∗ d)
1 Wall bracket PP (mounted on stand bracket) Dimensions with EMP KKS/II (h ∗ w ∗ d): 800 x 600 x 304 mm Dimensions with EMP III: 800 x 600 x 363 mm
1 Wall bracket PP (mounted on stand bracket) Dimensions with EMP KKS/II (h ∗ w ∗ d): 800 x 600 x 304 mm Dimensions with EMP III: 800 x 600 x 363 mm
1 diaphragm metering pump 2 diaphragm metering pumps 1 pump bracket 2 pump brackets 1 terminal box 1 terminal box 2 manual diaphragm non-return valves 3 manual diaphragm non-return valves (4 valves on
the version with 2 metering lines) Assembly of components, piping and wiring on the unit included
Assembly of components, piping and wiring on the unit included
Metering Consoles
EMP KKS / EMP II / EMP III
07/2013 Dosierkonsolen_e.doc 4
Available as an option: - Container PE (40, 75, 140, 200 l/h) and accessories (e.g. sump, stirring tool,…) - Suction pipe with level control (evaluation in the pump) - Multifunction valve (overflow, pressure maintenance, venting and drainage) - Degassing valve (only for EMP II) - Oval gear meter for volumetric measurement of the rate of flow (evaluation in the pump) - Metering hose - Metering valve - Drip tray PP für wall bracket See also chapter EMP KKS, EMP II, EMP III, metering container of “Metering Technology“ or chapter oval gear meter of “Measuring and Controlling”. Hydraulic connections:
EMP KKS EMP II EMP III Pump (inlet): 6/8, 6/10, 6/12 mm 4/6, 6/8, 6/12 mm 6/12, 10/16 mm Pump (outlet): 2/4 bzw. 4/6 mm 4/6, 6/8, 6/12 mm 6/12, 10/16 mm Hand valve outlet: 6/8 mm 6/8 mm 6/12 mm Multifunction valve: 4/6, 6/8, 6/12 mm 4/6, 6/8, 6/12 mm 6/12, 10/16 mm
Material:
Console with EMP KKS / EMP II Console with EMP III Console: PP Console: PP Support frame for stand- alone console:
1.4301 Support frame for stand- alone console:
1.4301
Pump: Pump: Pump head / suction and pressure
valves: PVDF Pump head / suction and pressure
valves: PP or PVDF*
Diaphragm: PTFE coated Diaphragm: PTFE coated Seals: FPM or EPDM* Seals: FPM or EPDM* Valve balls: Ceramics Valve balls: Ceramics
Diaphragm valves: PVC / PTFE Diaphragm valves: PVC / PTFE Container: PE Container: PE Suction pipe: PVC Suction pipe: PVC Multifunction valve: PVDF Multifunction valve: PP or PVDF* Degassing valve: PVDF -- -- Oval gear meter OGMPLUS: PVC / PVDF Oval gear meter OGMPLUS: PVC / PEEK Hose: PE or PTFE* Hose: PVC Metering valves: PVC / PVDF Metering valves: PP or PVDF*
* The material compatibilities on the product data sheet are to be observed.
Metering Consoles
EMP KKS / EMP II / EMP III
07/2013 Dosierkonsolen_e.doc 5
Ordering key:
Other versions on request.
1. Description DOK = metering console
2. Version WK = wall bracket SK = stand-alone
3. Electrical metering pump version E00 = E00 (only for EMP III) E10 = E10 E60 = E60
4. Pump capacity 50 Hz [60 Hz] pump type 00002 = 0.2 l/h [0.24 l/h] EMP KKS 00005 = 0.5 l/h [0.6l/h] EMP KKS 00009 = 0.9 l/h [1.1l/h] EMP KKS 00014 = 1.4 l/h [1.7l/h] EMP KKS V3014 = 1.4 l/h [1.7l/h] EMP II V3025 = 2.5 l/h [3.0l/h] EMP II 00043 = 4.3 l/h [5.2 l/h] EMP II 00048 = 4.8 l/h [5.8 l/h] EMP II 00072 = 7.2 l/h [8.6 l/h] EMP II 00112 = 11.2 l/h [13 l/h] EMP II 00240 = 11.2 l/h [29 l/h] EMP II 00160 = 16 l/h [19 l/h] EMP III 00250 = 25 l/h [30 l/h] EMP III 00540 = 54 l/h [64 l/h] EMP III
5. Pump head / suction and pressure valve material PP = PP PV = PVDF
6. Seal material EP = EPDM FP = Viton B
7. Number of pumps 1P1 = 1 pump, 1 metering line 2P1 = 2 pumps redundant on 1 metering line 2P2 = 2 pumps, 2 metering lines
8. Accessories MFV = multifunction valve (not for EMP KKS) EGV = degassing valve (for EMP II)
99 = without 9. Flow measurement
OGM = oval gear meter (OGM Plus) 99 = without
10. Console version
EC = Ecolab 99 = neutral
DOK WK E60 V3025 PV FP 2P1 MFV OGM EC
Example of a configured metering console.
Metering Consoles
Accessories
07/2013 Dosierkonsolen_e.doc 6
Metering pumps
EMP KKS Motor-driven diaphragm piston pump with self-venting function. Metering capacities: 0.2 / 0.5 / 0.9 / 1.4 l/h
Description / Order
Please see chapter Metering Technology / EMP KKS
EMP II Motor-driven diaphragm metering pump Metering capacities: 1.4 / 2.5 / 4.3 / 4.8 / 7.2 / 11.2 / 24 l/h
Description / Order
Please see chapter Metering Technology / EMP II
EMP III Motor-driven diaphragm metering pump Metering capacities: 16 / 25 / 54 l/h
Description / Order
Please see chapter Metering Technology / EMP III (a)
Metering Consoles
Accessories
07/2013 Dosierkonsolen_e.doc 7
Metering container
Technical data: Material: LLD-PE nature (low level density PE) Level scale: on the container Equipment: Supporting for stiring tool or hand mixer Aperture for sampling probe and level monitoring Screw cap with EPDM seal Outlet screw connection R 3/4"
Dimensions: Volume [L] Height [mm] External ∅ [mm] Cap ∅ [mm] 40 490 460 220 75 630 460 220 140 660 600 220 200 880 600 220
Description / Order
Please see chapter Metering Technology / Metering container
Suction pipes
Suction pipes EMP KKS
Suction pipe ∅ 32 with reserve and empty signal report incl. connecting cable 5 m with plug, return connection Lengths: 475 / 725 / 975 / 1125 mm Description / Order Please see chapter Metering Technology / EMP KKS
Suction pipes EMP II Suction pipe ∅ 16 with reserve and empty signal report incl. connecting cable 5 m with plug, Lengths: 540 / 750 / 970 / 1125 mm
Suction pipes EMP II / EMP III Suction pipe ∅ 32 with reserve and empty signal report incl. connecting cable 5 m with plug, Lengths: 475, 725, 975, 1125 mm Description / Order Please see chapter Metering Technology / EMP II/III
Metering Consoles
Accessories
07/2013 Dosierkonsolen_e.doc 8
Multifunction valve This safety-relevant component serves the purpose of protecting the piping system and the metering pump and permits safe and reliable commissioning and maintenance of the system.
The multiple function valve combines all of the following functions: overflow, pressure maintenance, venting and drainage
Description / Order
Please see chapter Metering Technology / EMP II/III
Degassing Control DegasPLUS The DegasPLUS is a combination of a degassing valve (EGV) and a connection cable with plug. Directly mountable on the pump metering valve, DegasPLUS in combination with a pump of the EMPII E60 series ensures an automatic degassing when metering an aerogenic medium. It is controlled by the pump software.
Description / Order Please see chapter Metering Technology / EMP II
Pos. Designation 1 Degassing Valve 2 Connection cable
Oval gear meter The OGMPLUS is used for volumetric measurement of the rate of flow of pure and cleaned liquids (max. 1000 mPas). The fact that this is a volumetric meter means that surging and discontinuous ("intermittent") flows can also be measured. This meter is therefore also extremely suitable for measurement of the volumetric flow of EMP diaphragm pumps.
Description / Order
Please see chapter Measuring and Controlling
1 2
Metering Consoles
Accessories
07/2013 Dosierkonsolen_e.doc 9
Suction and pressure lines
Suction line EMP KKS
PVC-Duo-hose 6/10 mm (suction and return line EMP-KKS)
See chapter Metering Technology / EMP KKS
Metering line EMP KKS
Hose PE 2/4 mm Hose PE 4/6 mm Hose PTFE 2/4 mm Hose PTFE 4/6 mm
See chapter Metering Technology / EMP KKS
Suction and pressure lines EMP II
Hose PE 4/6 mm Hose PE 6/8 m Hose PTFE 4/6 mm Hose PTFE 6/8 mm
See chapter Metering Technology / EMP II
PVC- fabric 6/12 mm
Suction and pressure lines EMP III
Hose PE 6/8 mm Hose PTFE 6/8 mm
See chapt. Metering Technology / EMP III (a)
PVC-fabric 6/12 mm
Metering valve
Metering valve EMP KKS / EMP II Spring-loaded ball valve with Elastomer ring on the outlet (prevents crystallisation, applicable for chloric products ) connection thread G3/8“, screw-in thread G1/4“ or G1/2“ Spring-loaded ball valve with metering pipe, connection thread G3/8“, screw-in thread G1/4“ or G1/2“ Description / Order See chapter Metering Technology / EMP KKS/II
Metering valve EMP III (a) Federbelastetes Kugelventil mit Dosierrohr, connection thread G5/8“, screw-in thread G1/2“ Description / Order See chapter Metering Technology / EMP III (a)
L 45
,5