© Copyright Atkar Au.diVent data sheet Product Description Durable fibre cement sheet panel with modular slot style perforations. Suitable for use as a ventilation panel or as an acoustic panel when supplied with our optional Integrated Acoustic Backing (IAB) or when installed with an appropriate absorbent backing material. Au.diVent is available with a choice of panel joint details to suit specific requirements and is ideally suited to high humidity or corrosive applications. Au.diVent helps to reduce ceiling space heat build-up and condensation by allowing natural ventilation of the roof space through the Au.diVent eaves. Product Features – Unaffected by steam, moisture, sunlight or vermin – Excellent water resistant properties – Ideal for harsh environments – Variety of jointing options – Suitable for curved surfaces Variations – Slotting module can be customised to suit special width sheets (consult Atkar Technical Staff) – Square or recessed edge Jointing Options – Vee or Expressed Joint – Recessed edge for Flush Jointing – PVC H-Mould – Cover Mould Material Sizes Standard panel size availability as shown below. Width (mm) 900 1200 2400 3000 1800 2400 2700 3000 Sheet Sizes (6mm Thick) For non-standard panel or module sizes, consult Atkar Technical Staff. Lengths (mm) Perforation Patterns Illustrated on the right is the standard perforation pattern available for full sheets. This pattern provides an open area of approximately 15%. Note: Drawing only displays section of 1200mm wide panel. Product Type AV205-216 2.1

Transcript of Au.diVent data sheet - Atkar NA · General fixing guide only, consult Atkar Technical Staff for...

Page 1: Au.diVent data sheet - Atkar NA · General fixing guide only, consult Atkar Technical Staff for full details. Installation Details The table to the left provides a fixing guide for

© Copyright Atkar

Au.diVent data sheet Product Description

Durable fibre cement sheet panel with modular slot style perforations. Suitable for use as a ventilation panel or as an acoustic panel when supplied with our optional Integrated Acoustic Backing (IAB) or when installed with an appropriate absorbent backing material. Au.diVent is available with a choice of panel joint details to suit specific requirements and is ideally suited to high humidity or corrosive applications. Au.diVent helps to reduce ceiling space heat build-up and condensation by allowing natural ventilation of the roof space through the Au.diVent eaves.

Product Features– Unaffected by steam, moisture, sunlight or vermin– Excellent water resistant properties– Ideal for harsh environments– Variety of jointing options– Suitable for curved surfaces

Variations– Slotting module can be customised to suit special

width sheets (consult Atkar Technical Staff )– Square or recessed edge

Jointing Options– Vee or Expressed Joint– Recessed edge for Flush Jointing– PVC H-Mould– Cover Mould

Material Sizes Standard panel size availability as shown below.

Width (mm)

900

1200

2400 3000

1800 2400 2700 3000

Sheet Sizes (6mm Thick)

For non-standard panel or module sizes, consult Atkar Technical Staff.

Lengths (mm)

Perforation Patterns Illustrated on the right is the standard perforation pattern available for full sheets. This pattern provides an open area of approximately 15%.

Note: Drawing only displays section of 1200mm wide panel.

Product Type AV205-216

2.1

Page 2: Au.diVent data sheet - Atkar NA · General fixing guide only, consult Atkar Technical Staff for full details. Installation Details The table to the left provides a fixing guide for

Attention – The method of fixing indicated for this product is of a general nature only and does not allow for specific design criteria such as wind loads, expansion joints or any other special design requirements which should be separately provided for by the specifier.

Due to continual product improvement the information in this publication is subject to alteration without notice.

Cover Mould

Cover Mould

Furring Channelor Timber Batten

PVC H-Mould

PVC H-Mould

Furring Channelor Timber Batten

Expressed JointVee Joint*

Furring Channelor Timber Batten

Furring Channelor Timber Batten

Acoustic Insulation(optional)

Integrated AcousticBacking or selectedscrim shown dotted Au•diVent panel

Acoustic Insulation(optional)

Integrated AcousticBacking or selectedscrim shown dotted Au•diVent panel

Acoustic Insulation(optional)

Integrated AcousticBacking or selectedscrim shown dotted Au•diVent panel

BackingStrip

Acoustic Insulation(optional)

Integrated AcousticBacking or selectedscrim shown dotted Au•diVent panel

*Vee jointing may create difficulties with panel and perforation alignment

Walls

6.0 600 200 300

200 250

Ceilings

Yes flush jointed applications only

Yes flush jointed applications only

Fastener Centres Perimeter (mm)

Fastener Centres Intermediate(mm)

Fastener TypeExpansion Joints Required

Maximum Framing Centres (mm)

Material Thickness (mm)

Locate fasteners not less than 12mm from sheet edges and 50mm from sheet corners. General fixing guide only, consult Atkar Technical Staff for full details.

Installation Details The table to the left provides a fixing guide for general commercial applications.

Au.diVent sheets should be fixed at right angles to framing where possible with sheet ends coinciding with framing members. Do not fix sheets directly to the underside of roof framing or structural members. Battens or furring channels must be used. Closer framing centres are required for high wind applications and where sheets are to be curved. For these applications or where flush jointing is to be incorporated, contact Atkar Technical Staff for details.

Jointing Details Please note. Acoustic insulation and selected scrim are only applicable in acoustic applications.

Au.diVent data sheet

© Copyright Atkar

Timber 3.0 x 2.8 fibre cement nail

Steel Light gauge steel SEH 8/20 S pt screw

Steel 0.75-1.2mm thick HD 8/22 screw

2.2

Page 3: Au.diVent data sheet - Atkar NA · General fixing guide only, consult Atkar Technical Staff for full details. Installation Details The table to the left provides a fixing guide for

The following Draft Specification contains sections of italicised text where the specifiers input is required.

Text identified with an asterisk* requires the non-applicable wording to be struck out or deleted. Text containing ‘……’ requires the specified information to be inserted.

1.0 General

1.1 Scope Materials listed below to be supplied and installed to all areas detailed on drawings, or otherwise quantified.

1.2 Qualifications Installation shall comply with the relevant building codes using approved fixings and the work executed by competent tradesmen.

1.3 Storage of Materials All materials delivered to site shall be stored flat in an enclosed shelter, providing protection from damage and exposure to the elements. Damaged or deteriorated material shall be immediately removed from site.

2.0 Product

2.1 Panels Ceilings/walls* shall be Au.diVent/Au.diVent IAB* multi-slotted fibre cement sheeting by Atkar, telephone 03 9796 3333. Panels shall be Atkar Product Type …… and ……mm thick with *.segde dessecer/erauqs

2.2 Insulation Alternative 1 Panels shall be supplied with Atkar Integrated Acoustic backing (IAB).

2.2 Alternative 2 Panels shall be installed with .……type and thickness backing insulation at the rear of each panel. Insulating materials to be laid across ……mm battens with fabric facing tensioned over battens to create a ……mm deep air gap/installed with insulation fitted between support members and fabric facing fitted over entire surface area* carefully installed to avoid creasing.

2.3 Execution Wall studs ceiling battens or furring channels shall be spaced at ……mm centres and panels laid at right angles to these members. Double furring channels or battens to be provided at sheet end joints for ceiling applications. Panels to be fixed with ……type of fastener at ……mm fixing centres around perimeter of panel and at ……mm fixing centres within the body of the panel. Panels shall be butted together and installed to create ……mm expressed joint / joints covered with a ……x……mm size ……type timber cover strip/ fitted into appropriately sized H-mould sheet holders/joints taped, and flush jointed in accordance with manufacturer’s published specifications.*

2.4 Completion Upon completion of the installation, check that all panels and cover moulds (if applicable) are securely fastened to their framing members and all fixings are properly stopped with an approved filler. Surface to be prepared to an approved standard in readiness to receive surface treatment applied by others.

Au.diVent draft specification

© Copyright Atkar

2.3

Page 4: Au.diVent data sheet - Atkar NA · General fixing guide only, consult Atkar Technical Staff for full details. Installation Details The table to the left provides a fixing guide for

© Copyright Atkar

Au.diVent data sheet Product Description

Au.diVent slotted eaves lining allows eaves to be simultaneously lined and vented, admitting fresh air to the roof space and enabling detrimental moist air to flow out through its continuous slotting pattern. With the durability inherent to fibre cement sheet, Au.diVent provides cost-effective long-term benefits.

Refer to Au.diVent, Slotted Fibre Cement, Data Sheet 2.1.1 – 2.1.3 for fully slotted panel details.

Product Features– Summer – reduces building heat load during the

day by removing hot roof space air, which in addition prevents condensation forming at night

– Winter – helps prevent the accumulation of warm moist air in the roof space, from heaters, cookers etc allowing insulation to work most efficiently and also helping to prevent condensation

– Enhances the appearance of eaves– Will not burn or rot and is immune to

permanent water damage– No operating costs or moving parts

Product Type AV/NSR Product Type AV/NTS

One row, slots start 80mmfrom long edge of the sheet

Two rows, slots start 80mmfrom long edges of the sheet

Corner SquaresTo suit Product Type AV/NSR

Other designs areavailable to architectsor builders specifications

© Copyright Atkar

Slot size 150 x 6mmat 50mm centres

Product Type AV/NCR Product Type AV/NTR

One row centred on sheetslots evenly spaced

Two rowsslots evenly spaced

Perforation Patterns Variations– Range of sheet sizes in 4.5mm or 6.0mm thickness– Selection of patterns to suit most designs

or applications– Available in recessed edge sheets to suit

flush jointing (6.0mm only) special manufacture

Jointing Options– Vee Joint– PVC H-Mould– Cover Mould

Material Sizes Standard panel size availability as shown below. For non-standard panels, consult Atkar Technical Staff.

1800mm

2100mm

2400mm

2700mm

3000mm

450m

m

600 m

m

750 m

m

900 m

m

1200

mm

• ••

• • • ••• •• •

• 4.5mm thick 6mm thick

2.4

Page 5: Au.diVent data sheet - Atkar NA · General fixing guide only, consult Atkar Technical Staff for full details. Installation Details The table to the left provides a fixing guide for

Attention – The method of fixing indicated for this product is of a general nature only and does not allow for specific design criteria such as wind loads, expansion joints or any other special design requirements which should be separately provided for by the specifier.

Due to continual product improvement the information in this publication is subject to alteration without notice.

© Copyright. No part of this publication may be reproduced without the written consent of Atkar.

Vee Joint Timber or Metal Batten PVC H-Mould Timber or Metal Batten Cover Mould Timber or Metal Batten

Cover Mould Au•diVent EavesAu•diVent EavesAu•diVent Eaves

Jointing Details

Timber 3.0 x 2.0 fibre cement nail

4.5 450 200 300

6.0 600 200 300

No

No

Steel Light gauge steel SEH 8/20 ‘S’ pt screw*

Fastener Centres Perimeter (mm)

Fastener Centres Intermediate(mm)

Fastener TypeExpansion Joints Required

Maximum Framing Centres (mm)

Type (mm)

Timber 3.0 x 2.0 fibre cement nail

Steel 0.75 – 1.2mm thick HD 8/22 screw*

Installation Details The table to the right is relevant to 900 and 1200mm wide sheets laid at right angles to the supporting framework. When narrower width sheets are to be installed in a standard eave configuration with both long sides supported, maximum trimmer centres are:

Do not fix sheets directly to the underside of roof framing or structural members. Battens or furring channels must be used.

Closer framing centres are required for high wind applications and where sheets are to be curved. For these applications or where flush jointing is to be incorporated, consult Atkar Technical Staff for details.

Eave Width (mm)

450 1200 1200

600 900 1200

750 – 1200 Max 800 1000

Within 1200mm of external building corners

Elsewhere

Trimmer Centres (mm)

Locate fasteners not less than 12mm from sheet edges and 50mm from sheet corners. General fixing guide only, consult Atkar Technical Staff for full details.

* Not suitable for 4.5mm sheets

Au.diVent data sheet

© Copyright Atkar

2.5

Page 6: Au.diVent data sheet - Atkar NA · General fixing guide only, consult Atkar Technical Staff for full details. Installation Details The table to the left provides a fixing guide for

The following Draft Specification contains sections of italicised text where the specifiers input is required.

Text identified with an asterisk* requires the non-applicable wording to be struck out or deleted. Text containing ‘……’ requires the specified information to be inserted.

1.0 General

1.1 Scope Materials listed below to be supplied and installed to all areas detailed on drawings, or otherwise quantified.

1.2 Qualifications Installation shall comply with the relevant building codes using approved fixings and the work executed by competent tradesmen.

1.3 Storage of Materials All materials delivered to site shall be stored flat in an enclosed shelter, providing protection from damage. Damaged or deteriorated material shall be immediately removed from site.

2.0 Product

2.1 Panels Eaves/soffits* shall be lined with a continuous run of Au.diVent Slotted Eaves Lining by Atkar, telephone 03 9796 3333. Sheets shall be Atkar Product Type …… and ……mm thick.

2.2 Execution Trimmers, ceiling battens or furring channels shall be spaced at ……mm centres and panels laid at right angles to these members. Panels to be fixed with ……type of fastener at ……mm fixing centres around perimeter of panel and at ……mm fixing centres within the body of the panel. Panels shall be butted together and joints covered with a ……x……size……type timber cover strip/fitted into appropriately sized H-mould sheetholders.*

2.3 Completion Upon completion of the installation, check that all panels and cover moulds (if applicable) are securely fastened to their framing members and all fixings are properly installed. Surface to be prepared to an approved standard in readiness to receive surface treatment applied by others.

Au.diVent draft specification

© Copyright Atkar1276 Osprey Drive, Ancaster, ON L9G 4V5 Canada 905.648.7580 [email protected] www.atkar-na.com