Au.diVent data sheet Product Description
Durable fibre cement sheet panel with modular slot style perforations. Suitable for use as a ventilation panel or as an acoustic panel when supplied with our optional Integrated Acoustic Backing (IAB) or when installed with an appropriate absorbent backing material. Au.diVent is available with a choice of panel joint details to suit specific requirements and is ideally suited to high humidity or corrosive applications. Au.diVent helps to reduce ceiling space heat build-up and condensation by allowing natural ventilation of the roof space through the Au.diVent eaves.
Product Features– Unaffected by steam, moisture, sunlight or vermin– Excellent water resistant properties– Ideal for harsh environments– Variety of jointing options– Suitable for curved surfaces
Variations– Slotting module can be customised to suit special
width sheets (consult Atkar Technical Staff )– Square or recessed edge
Jointing Options– Vee or Expressed Joint– Recessed edge for Flush Jointing– PVC H-Mould– Cover Mould
Material Sizes Standard panel size availability as shown below.
Width (mm)
900
1200
2400 3000
1800 2400 2700 3000
Sheet Sizes (6mm Thick)
For non-standard panel or module sizes, consult Atkar Technical Staff.
Lengths (mm)
Perforation Patterns Illustrated on the right is the standard perforation pattern available for full sheets. This pattern provides an open area of approximately 15%.
Note: Drawing only displays section of 1200mm wide panel.
Product Type AV205-216
2.1
Attention – The method of fixing indicated for this product is of a general nature only and does not allow for specific design criteria such as wind loads, expansion joints or any other special design requirements which should be separately provided for by the specifier.
Due to continual product improvement the information in this publication is subject to alteration without notice.
Cover Mould
Cover Mould
Furring Channelor Timber Batten
PVC H-Mould
PVC H-Mould
Furring Channelor Timber Batten
Expressed JointVee Joint*
Furring Channelor Timber Batten
Furring Channelor Timber Batten
Acoustic Insulation(optional)
Integrated AcousticBacking or selectedscrim shown dotted Au•diVent panel
Acoustic Insulation(optional)
Integrated AcousticBacking or selectedscrim shown dotted Au•diVent panel
Acoustic Insulation(optional)
Integrated AcousticBacking or selectedscrim shown dotted Au•diVent panel
BackingStrip
Acoustic Insulation(optional)
Integrated AcousticBacking or selectedscrim shown dotted Au•diVent panel
*Vee jointing may create difficulties with panel and perforation alignment
Walls
6.0 600 200 300
200 250
Ceilings
Yes flush jointed applications only
Yes flush jointed applications only
Fastener Centres Perimeter (mm)
Fastener Centres Intermediate(mm)
Fastener TypeExpansion Joints Required
Maximum Framing Centres (mm)
Material Thickness (mm)
Locate fasteners not less than 12mm from sheet edges and 50mm from sheet corners. General fixing guide only, consult Atkar Technical Staff for full details.
Installation Details The table to the left provides a fixing guide for general commercial applications.
Au.diVent sheets should be fixed at right angles to framing where possible with sheet ends coinciding with framing members. Do not fix sheets directly to the underside of roof framing or structural members. Battens or furring channels must be used. Closer framing centres are required for high wind applications and where sheets are to be curved. For these applications or where flush jointing is to be incorporated, contact Atkar Technical Staff for details.
Jointing Details Please note. Acoustic insulation and selected scrim are only applicable in acoustic applications.
Au.diVent data sheet
© Copyright Atkar
Timber 3.0 x 2.8 fibre cement nail
Steel Light gauge steel SEH 8/20 S pt screw
Steel 0.75-1.2mm thick HD 8/22 screw
2.2
The following Draft Specification contains sections of italicised text where the specifiers input is required.
Text identified with an asterisk* requires the non-applicable wording to be struck out or deleted. Text containing ‘……’ requires the specified information to be inserted.
1.0 General
1.1 Scope Materials listed below to be supplied and installed to all areas detailed on drawings, or otherwise quantified.
1.2 Qualifications Installation shall comply with the relevant building codes using approved fixings and the work executed by competent tradesmen.
1.3 Storage of Materials All materials delivered to site shall be stored flat in an enclosed shelter, providing protection from damage and exposure to the elements. Damaged or deteriorated material shall be immediately removed from site.
2.0 Product
2.1 Panels Ceilings/walls* shall be Au.diVent/Au.diVent IAB* multi-slotted fibre cement sheeting by Atkar, telephone 03 9796 3333. Panels shall be Atkar Product Type …… and ……mm thick with *.segde dessecer/erauqs
2.2 Insulation Alternative 1 Panels shall be supplied with Atkar Integrated Acoustic backing (IAB).
2.2 Alternative 2 Panels shall be installed with .……type and thickness backing insulation at the rear of each panel. Insulating materials to be laid across ……mm battens with fabric facing tensioned over battens to create a ……mm deep air gap/installed with insulation fitted between support members and fabric facing fitted over entire surface area* carefully installed to avoid creasing.
2.3 Execution Wall studs ceiling battens or furring channels shall be spaced at ……mm centres and panels laid at right angles to these members. Double furring channels or battens to be provided at sheet end joints for ceiling applications. Panels to be fixed with ……type of fastener at ……mm fixing centres around perimeter of panel and at ……mm fixing centres within the body of the panel. Panels shall be butted together and installed to create ……mm expressed joint / joints covered with a ……x……mm size ……type timber cover strip/ fitted into appropriately sized H-mould sheet holders/joints taped, and flush jointed in accordance with manufacturer’s published specifications.*
2.4 Completion Upon completion of the installation, check that all panels and cover moulds (if applicable) are securely fastened to their framing members and all fixings are properly stopped with an approved filler. Surface to be prepared to an approved standard in readiness to receive surface treatment applied by others.
Au.diVent draft specification
© Copyright Atkar
2.3
© Copyright Atkar
Au.diVent data sheet Product Description
Au.diVent slotted eaves lining allows eaves to be simultaneously lined and vented, admitting fresh air to the roof space and enabling detrimental moist air to flow out through its continuous slotting pattern. With the durability inherent to fibre cement sheet, Au.diVent provides cost-effective long-term benefits.
Refer to Au.diVent, Slotted Fibre Cement, Data Sheet 2.1.1 – 2.1.3 for fully slotted panel details.
Product Features– Summer – reduces building heat load during the
day by removing hot roof space air, which in addition prevents condensation forming at night
– Winter – helps prevent the accumulation of warm moist air in the roof space, from heaters, cookers etc allowing insulation to work most efficiently and also helping to prevent condensation
– Enhances the appearance of eaves– Will not burn or rot and is immune to
permanent water damage– No operating costs or moving parts
Product Type AV/NSR Product Type AV/NTS
One row, slots start 80mmfrom long edge of the sheet
Two rows, slots start 80mmfrom long edges of the sheet
Corner SquaresTo suit Product Type AV/NSR
Other designs areavailable to architectsor builders specifications
© Copyright Atkar
Slot size 150 x 6mmat 50mm centres
Product Type AV/NCR Product Type AV/NTR
One row centred on sheetslots evenly spaced
Two rowsslots evenly spaced
Perforation Patterns Variations– Range of sheet sizes in 4.5mm or 6.0mm thickness– Selection of patterns to suit most designs
or applications– Available in recessed edge sheets to suit
flush jointing (6.0mm only) special manufacture
Jointing Options– Vee Joint– PVC H-Mould– Cover Mould
Material Sizes Standard panel size availability as shown below. For non-standard panels, consult Atkar Technical Staff.
1800mm
2100mm
2400mm
2700mm
3000mm
450m
m
600 m
m
750 m
m
900 m
m
1200
mm
• ••
• • • ••• •• •
• 4.5mm thick 6mm thick
2.4
Attention – The method of fixing indicated for this product is of a general nature only and does not allow for specific design criteria such as wind loads, expansion joints or any other special design requirements which should be separately provided for by the specifier.
Due to continual product improvement the information in this publication is subject to alteration without notice.
© Copyright. No part of this publication may be reproduced without the written consent of Atkar.
Vee Joint Timber or Metal Batten PVC H-Mould Timber or Metal Batten Cover Mould Timber or Metal Batten
Cover Mould Au•diVent EavesAu•diVent EavesAu•diVent Eaves
Jointing Details
Timber 3.0 x 2.0 fibre cement nail
4.5 450 200 300
6.0 600 200 300
No
No
Steel Light gauge steel SEH 8/20 ‘S’ pt screw*
Fastener Centres Perimeter (mm)
Fastener Centres Intermediate(mm)
Fastener TypeExpansion Joints Required
Maximum Framing Centres (mm)
Type (mm)
Timber 3.0 x 2.0 fibre cement nail
Steel 0.75 – 1.2mm thick HD 8/22 screw*
Installation Details The table to the right is relevant to 900 and 1200mm wide sheets laid at right angles to the supporting framework. When narrower width sheets are to be installed in a standard eave configuration with both long sides supported, maximum trimmer centres are:
Do not fix sheets directly to the underside of roof framing or structural members. Battens or furring channels must be used.
Closer framing centres are required for high wind applications and where sheets are to be curved. For these applications or where flush jointing is to be incorporated, consult Atkar Technical Staff for details.
Eave Width (mm)
450 1200 1200
600 900 1200
750 – 1200 Max 800 1000
Within 1200mm of external building corners
Elsewhere
Trimmer Centres (mm)
Locate fasteners not less than 12mm from sheet edges and 50mm from sheet corners. General fixing guide only, consult Atkar Technical Staff for full details.
* Not suitable for 4.5mm sheets
Au.diVent data sheet
© Copyright Atkar
2.5
The following Draft Specification contains sections of italicised text where the specifiers input is required.
Text identified with an asterisk* requires the non-applicable wording to be struck out or deleted. Text containing ‘……’ requires the specified information to be inserted.
1.0 General
1.1 Scope Materials listed below to be supplied and installed to all areas detailed on drawings, or otherwise quantified.
1.2 Qualifications Installation shall comply with the relevant building codes using approved fixings and the work executed by competent tradesmen.
1.3 Storage of Materials All materials delivered to site shall be stored flat in an enclosed shelter, providing protection from damage. Damaged or deteriorated material shall be immediately removed from site.
2.0 Product
2.1 Panels Eaves/soffits* shall be lined with a continuous run of Au.diVent Slotted Eaves Lining by Atkar, telephone 03 9796 3333. Sheets shall be Atkar Product Type …… and ……mm thick.
2.2 Execution Trimmers, ceiling battens or furring channels shall be spaced at ……mm centres and panels laid at right angles to these members. Panels to be fixed with ……type of fastener at ……mm fixing centres around perimeter of panel and at ……mm fixing centres within the body of the panel. Panels shall be butted together and joints covered with a ……x……size……type timber cover strip/fitted into appropriately sized H-mould sheetholders.*
2.3 Completion Upon completion of the installation, check that all panels and cover moulds (if applicable) are securely fastened to their framing members and all fixings are properly installed. Surface to be prepared to an approved standard in readiness to receive surface treatment applied by others.
Au.diVent draft specification