Version 009 Issued: 8/01/2014 Page 1 of 19 500 Montgomery St. Suite 625Alexandria, VA 22314703-836-0025 www.aclasscorp.com SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & CERTIFIED COMPLIANCE TO ANSI/NCSL Z540-1-1994 Departamento de Metrología, Avianca S.A. Calle 26 No. 103-08 Terminal Simón Bolívar Bogotá, Colombia Ing. Marco A. Brugés www.avianca.com [email protected] Phone: 5714578700 x 139, 263 CALIBRATION Valid to: August 1, 2016 Certificate Number: AC-1327 I. Electromagnetic - DC/Low Frequency PARAMETER/ EQUIPMENT RANGE CALIBRATION & MEASUREMENT CAPABILITY [EXPRESSED AS UNCERTAINTY(+)] REFERENCE STANDARD OR EQUIPMENT METHOD(S) DC Voltage - Source 5 Up to 330 mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V 330 V to 1 kV 20 μV/V + 1.8 μV 11 μV/V + 9.6 μV 12 μV/V + 0.11 mV 18 μV/V + 1.1 mV 18 μV/V + 3.9 mV Fluke 5520A SC600 OEM*,CEM,IEC, EURAMET,EA or Internal Procedures DC Voltage - Measure 5 Up to 200 mV 200 mV to 2 V (2 to 20) V (20 to 200) V 200 V to 1 kV Up to 6 kV 2.7 μV/V + 0.65 μV 2.7 μV/V + 1.8 μV 2.7 μV/V + 18 μV 4.0 μV/V + 0.18 mV 4.0 μV/V + 1.3 mV 1.6 mV/V Fluke 8508A Option 01 with VRS-100-5-1G-10kV DC Current - Source 5 with Current Clamp Up to 330 μA 330 μA to 3.3 mA (3.3 to 33) mA (33 to 330) mA 330 mA to 1.1 A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (20.5 to 1 025) A 0.15 mA/A + 20 nA 0.10 mA/A + 60 nA 0.10 mA/A + 0.50 μA 0.10 mA/A + 8 μA 0.20 mA/A + 50 μA 0.38 mA/A + 0.20 mA 0.50 mA/A + 0.80 mA 1 mA/A + 2 mA 3.4 mA/A Fluke 5520A SC600 Fluke 5520A with 5500A Coil ANSI-ASQ National Accreditation Board/ACLASS

Transcript of ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts)...

Page 1: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 1 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

& CERTIFIED COMPLIANCE TO ANSI/NCSL Z540-1-1994

Departamento de Metrología, Avianca S.A. Calle 26 No. 103-08 Terminal Simón Bolívar Bogotá, Colombia

Ing. Marco A. Brugés www.avianca.com

[email protected] Phone: 5714578700 x 139, 263

CALIBRATION

Valid to: August 1, 2016 Certificate Number: AC-1327

I. Electromagnetic - DC/Low Frequency

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

DC Voltage - Source5

Up to 330 mV

330 mV to 3.3 V

(3.3 to 33) V

(33 to 330) V

330 V to 1 kV

20 µV/V + 1.8 µV

11 µV/V + 9.6 µV

12 µV/V + 0.11 mV

18 µV/V + 1.1 mV

18 µV/V + 3.9 mV

Fluke 5520A SC600

OEM*,CEM,IEC,

EURAMET,EA or

Internal Procedures

DC Voltage - Measure5

Up to 200 mV

200 mV to 2 V

(2 to 20) V

(20 to 200) V

200 V to 1 kV

Up to 6 kV

2.7 µV/V + 0.65 µV

2.7 µV/V + 1.8 µV

2.7 µV/V + 18 µV

4.0 µV/V + 0.18 mV

4.0 µV/V + 1.3 mV

1.6 mV/V

Fluke 8508A Option 01

with

VRS-100-5-1G-10kV

DC Current - Source5

with Current Clamp

Up to 330 µA

330 µA to 3.3 mA

(3.3 to 33) mA

(33 to 330) mA

330 mA to 1.1 A

(1.1 to 3) A

(3 to 11) A

(11 to 20.5) A

(20.5 to 1 025) A

0.15 mA/A + 20 nA

0.10 mA/A + 60 nA

0.10 mA/A + 0.50 µA

0.10 mA/A + 8 µA

0.20 mA/A + 50 µA

0.38 mA/A + 0.20 mA

0.50 mA/A + 0.80 mA

1 mA/A + 2 mA

3.4 mA/A

Fluke 5520A SC600

Fluke 5520A

with 5500A Coil

ANSI-ASQ National Accreditation Board/ACLASS

Page 2: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 2 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

DC Current - Measure5

Up to 100 nA

100 nA to 1 µA

1 µA to 10 µA

10 µA to 100 µA

Up to 200 µA

200 µA to 2 mA

(2 to 20) mA

(20 to 200) mA

200 mA to 2 A

(2 to 20) A

(20 to 50) A

30 µA/A + 40 pA

20 µA/A + 50 pA

20 µA/A + 0.20 nA

20 µA/A + 0.90 nA

6.6 µA/A + 5 nA

6.6 µA/A + 20 nA

8 µA/A + 90 nA

34 µA/A + 3 µA

0.17 mA/A + 40 µA

0.38 mA/A + 2 mA

18 mA/A

Agilent 3488A

Fluke 8508A Opt 001

with Current Shunt

1651 Keithley

OEM*,CEM,IEC,

EURAMET,EA or

Internal Procedures

Resistance - Source5

Up to 11 Ω

(11 to 33) Ω

(33 to 110) Ω

(110 to 330) Ω

330 Ω to 1.1 kΩ

(1.1 to 3.3) kΩ

(3.3 to 11) kΩ

(11 to 33) kΩ

(33 to 110) kΩ

(110 to 330) kΩ

330 kΩ to 1.1 MΩ

(1.1 to 3.3) MΩ

(3.3 to 11) MΩ

(11 to 33) MΩ

(33 to 110) MΩ

(110 to 330) MΩ

330 MΩ to 1.1 GΩ

50 µΩ

100 µΩ

500 µΩ

(0.001 to 0.01) Ω

(0.01 to 1) Ω

(1 to 10) Ω

10 Ω to 10 kΩ

40 µΩ/Ω + 1.1 mΩ

30 µΩ/Ω + 1.6 mΩ

28 µΩ/Ω + 1.6 mΩ

28 µΩ/Ω + 2.7 mΩ

28 µΩ/Ω + 6 mΩ

28 µΩ/Ω + 33 mΩ

28 µΩ/Ω + 84 mΩ

28 µΩ/Ω + 0.33 Ω

28 µΩ/Ω + 0.90 Ω

32 µΩ/Ω + 3 Ω

32 µΩ/Ω + 6.9 Ω

60 µΩ/Ω + 47 Ω

0.13 mΩ/Ω + 0.21 kΩ

0.25 mΩ/Ω + 3.2 kΩ

0.50 mΩ/Ω + 9.6 kΩ

3 mΩ/Ω + 0.13 MΩ

15 mΩ/Ω + 1.4 MΩ

3 µΩ

3 µΩ

20 µΩ

0.10 mΩ/Ω + 0.2 mΩ

70 µΩ/Ω + 0.2 mΩ

70 µΩ/Ω

45 µΩ/Ω

Fluke 5520A SC600

Avtron

Shunts C2047

High Accuracy

Resistance Substituter

HARS-X-11-0.001

OEM*,CEM,

EURAMET,EA or

Internal Procedures

Page 3: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 3 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

Resistance - Source5

(cont.)

(10 to 100) kΩ

100 kΩ to 1 MΩ

(1 to 10) MΩ

(10 to 100) MΩ

100 MΩ to 1 GΩ

(1 to 10) GΩ

(10 to 301) GΩ

1 TΩ

10 TΩ

35 µΩ/Ω

0.13 mΩ/Ω

50 µΩ/Ω

225 µΩ/Ω

0.75 mΩ/Ω

0.75 mΩ/Ω

1 mΩ/Ω

24 GΩ

0.58 TΩ

High Accuracy

Resistance Substituter

HRRS-B-5-100K

HARS-X-11-0.001

High Resistance

VICTOREEN

VRS-100-5-1G-10kV

High-Resistance

High Voltage Decade

Substituter

OEM*,CEM,

EURAMET,EA or

Internal Procedures

Resistance - Measure5

Up to 2 Ω

(2 to 20) Ω

(2 to 200) Ω

200 Ω to 2 kΩ

(2 to 20) kΩ

(20 to 200) kΩ

200 kΩ to 2 MΩ

(2 to 20) MΩ

(20 to 200) MΩ

200 MΩ to 2 GΩ

(2 to 20) GΩ

(20 to 190) GΩ

10 µΩ/Ω + 19 µΩ

7 µΩ/Ω + 63 µΩ

7 µΩ/Ω + 5 mΩ

7 µΩ/Ω + 3 mΩ

7 µΩ/Ω + 31 mΩ

7 µΩ/Ω + 0.52 Ω

7 µΩ/Ω + 8.8 Ω

9 µΩ/Ω + 0.21 kΩ

30 µΩ/Ω + 14 kΩ

0.50 mΩ/Ω + 1.1 MΩ

0.50 mΩ/Ω + 13 MΩ

8.95 mΩ/Ω

Fluke 8508A Opt 01

Fluke 5520A and Agilent

3458A (Amp) and

Fluke 8508A (Volts)

Defibrillator5 -

Energy Source (10 to 360) J 1.4 J Fluke

Impulse 7000 DP

OEM*, CEM

EURAMET,EA

ABNT or Internal

Procedures

Inductance - Measure

at 1 kHz 0.00001 mH to 99 999 H 0.20 mH/H

RLC 1689 Digibridge

Quadtech OEM*, CEM,EA

ABNT or Internal

Procedures Inductance - Source

at 1 kHz 100 µH to 10 H 23 mH/H

Decade Inductor

1491

Page 4: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 4 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

AC Voltage – Source5

(1 to 33) mV

(10 to 45) Hz

45 Hz to 10 kHz

(10 to 20) kHz

(20 to 50) kHz

(50 to 100) kHz

(100 to 500) kHz

(33 to 330) mV

(10 to 45) Hz

45 Hz to 10 kHz

(10 to 20) kHz

(20 to 50) kHz

(50 to 100) kHz

(100 to 500) kHz

330 mV to 3.3 V

(10 to 45) Hz

45 Hz to 10 kHz

(10 to 20) kHz

(20 to 50) kHz

(50 to 100) kHz

(100 to 500) kHz

(3.3 to 33) V

(10 to 45) Hz

45 Hz to 10 kHz

(10 to 20) kHz

(20 to 50) kHz

(50 to 100) kHz

(33 to 330) V

45 Hz to 1 kHz

(1 to 10) kHz

(10 to 20) kHz

(20 to 50) kHz

(50 to 100) kHz

330 V to 1.02 kV

45 Hz to 1 kHz

(1 to 5) kHz

(5 to 10) kHz

0.80 mV/V + 6.8 µV

0.15 mV/V + 6.8 µV

0.20 mV/V + 6.8 µV

1 mV/V + 10 µV

3.5 mV/V + 25 µV

8 mV/V + 55 µV

0.30 mV/V + 13 µV

0.15 mV/V + 13 µV

0.16 mV/V + 13 µV

0.35 mV/V + 17 µV

0.80 mV/V + 40 µV

2 mV/V + 1.1 mV

0.30 mV/V + 0.11 mV

0.15 mV/V + 0.11 mV

0.19 mV/V + 0.11 mV

0.30 mV/V + 0.13 mV

0.70 mV/V + 0.23 mV

2.4 mV/V + 1.2 mV

0.30 mV/V + 1.2 mV

0.15 mV/V + 1.1 mV

0.24 mV/V + 1.1 mV

0.35 mV/V + 1.5 mV

0.90 mV/V + 2.8 mV

0.19 mV/V + 13 mV

0.20 mV/V + 14 mV

0.25 mV/V + 14 mV

0.30 mV/V + 14 mV

2 mV/V + 59 mV

0.30 mV/V + 33 mV

0.25 mV/V + 36 mV

0.30 mV/V + 36 mV

Fluke 5520A SC600

OEM*, CEM,

EURAMET, EA or

Internal

Procedures

AC Voltage - Measure5

Up to 200 mV

(1 to 10) Hz

(10 to 40) Hz

(40 to 100) Hz

100 Hz to 2 kHz

(2 to 10) kHz

(10 to 30) kHz

(30 to 100) kHz

0.12 mV/V + 16 µV

0.12 mV/V + 7.4 µV

0.10 mV/V + 9.3 µV

0.10 mV/V + 7.4 µV

0.10 mV/V + 8.1 µV

0.30 mV/V + 8.0 µV

0.70 mV/V + 31 µV

Fluke 8508A Opt 001

Page 5: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 5 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

AC Voltage – Measure5

(cont.)

200 mV to 2 V

(1 to 10) Hz

(10 to 40) Hz

(40 to 100) Hz

100 Hz to 2 kHz

(2 to 10) kHz

(10 to 30) kHz

(30 to 100) kHz

(100 to 300) kHz

300 kHz to 1 MHz

(2 to 20) V

(1 to 10) Hz

(10 to 40) Hz

(40 to 100) Hz

100 Hz to 2 kHz

(2 to 10) kHz

(10 to 30) kHz

(30 to 100) kHz

(100 to 300) kHz

300 kHz to 1 MHz

(20 to 200) V

(1 to 10) Hz

(10 to 40) Hz

(40 to 100) Hz

100 Hz to 2 kHz

(2 to 10) kHz

(10 to 30) kHz

(30 to 100) kHz

(100 to 300) kHz

300 kHz to 1 MHz

200 V to 1.05 kV

(1 to 10) Hz

(10 to 40) Hz

40 Hz to 10 kHz

(10 to 30) kHz

(30 to 100) kHz

Up to 6 kV 60 Hz

0.10 mV/V + 0.15 mV

0.10 mV/V + 83 µV

80 µV/V + 46 µV

60 µV/V + 50 µV

80 µV/V + 57 µV

0.20 mV/V + 0.12 mV

0.50 mV/V + 0.34 mV

3 mV/V + 2.3 mV

10 mV/V + 21 mV

0.10 mV/V + 1.5 mV

0.10 mV/V + 5.8 mV

80 µV/V + 0.54 mV

60 µV/V + 0.54 mV

80 µV/V + 0.53 mV

0.20 mV/V + 0.58 mV

0.50 mV/V + 2.6 mV

3 mV/V + 22 mV

10 mV/V + 0.21 V

0.10 mV/V + 14 mV

0.10 mV/V + 6.6 mV

80 µV/V + 4.5 mV

60 µV/V + 4.5 mV

80 µV/V + 4.5 mV

0.20 mV/V + 6.4 mV

0.50 mV/V + 27 mV

3 mV/V + 0.20 V

10 mV/V + 2 V

0.10 mV/V + 80 mV

0.10 mV/V + 37 mV

80 µV/V + 0.12 V

0.20 mV/V + 29 mV

0.50 mV/V + 36 mV

15 mV/V

Fluke 8508A Opt 001

High Voltage Probe

80K-6 together with

Fluke 289

OEM*,CEM,

EURAMET,EA or

Internal

Procedures

Page 6: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 6 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

AC Current - Source5

Clamp-On Current

(29 to 200) µA

(1 to 10) Hz

10 Hz to 10 kHz

(10 to 30) kHz

200 µA to 2 mA

(1 to 10) Hz

10 Hz to 10 kHz

(10 to 30) kHz

(2 to 20) mA

(1 to 10) Hz

10 Hz to 10 kHz

(10 to 30) kHz

(20 to 200) mA

(1 to 10) Hz

10 Hz to 10 kHz

(10 to 30) kHz

200 mA to 2 A

(1 to 10) Hz

10 Hz to 2 kHz

(2 to 10) kHz

(2 to 20) A

45 Hz to 2 kHz

(2 to 5) kHz

(20 to 1 025) A

(45 to 65) Hz

(65 to 400) Hz

0.25 mA/A + 24 nA

0.25 mA/A + 46 nA

0.60 mA/A + 46 nA

0.25 mA/A + 0.29 µA

0.25 mA/A + 0.27 µA

0.60 mA/A + 0.27 µA

0.25 mA/A + 2.9 µA

0.25 mA/A + 3.2 µA

0.60 mA/A + 3.2 µA

0.25 mA/A + 29 µA

0.25 mA/A + 29 µA

0.60 mA/A + 29 µA

0.60 mA/A + 0.29 mA

0.70 mA/A + 0.45 mA

3 mA/A + 1.1 mA

0.80 mA/A + 3.6 mA

2.5 mA/A + 11 mA

3.9 mA/A

8.9 mA/A

Fluke 5520A SC 600,

Fluke 8508A Opt 01

with 5500A Coil

OEM*, CEM

EURAMET or

Internal

Procedures

AC Current - Measure5

Up to 200 µA

(1 to 10) Hz

10 Hz to 10 kHz

(10 to 30) kHz

(30 to 100) kHz

200 µA to 2 mA

(1 to 10) Hz

10 Hz to 10 kHz

(10 to 30) kHz

(30 to 100) kHz

(2 to 20) mA

(1 to 10) Hz

10 Hz to 10 kHz

(10 to 30) kHz

(30 to 100) kHz

(20 to 200) mA

(1 to 10) Hz

10 Hz to 10 kHz

(10 to 30) kHz

0.25 mA/A + 29 nA

0.25 mA/A + 45 nA

0.60 mA/A + 45 nA

4 mA/A + 45 nA

0.25 mA/A + 0.29 µA

0.25 mA/A + 0.27 µA

0.60 mA/A + 0.27 µA

4 mA/A + 0.27 µA

0.25 mA/A + 2.9 µA

0.25 mA/A + 3.2 µA

0.60 mA/A + 3.2 µA

4 mA/A + 3.2 µA

0.25 mA/A + 29 µA

0.25 mA/A + 29 µA

0.60 mA/A + 29 µA

Fluke 8508A Opt 01

Page 7: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 7 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

AC Current - Measure5

(cont.)

200 mA to 2 A

10 Hz to 2 kHz

(2 to 10) kHz

(10 to 30) kHz

(2 to 20) A

10 Hz to 2 kHz

(2 to 10) kHz

(20 to 50) A

60 Hz

0.60 mA/A + 0.29 mA

0.70 mA/A + 1.1 mA

3 mA/A + 1.1 mA

0.80 mA/A + 3.6 mA

2.5 mA/A + 3.6 mA

18 mA/A

Fluke 8508A Opt 01

with Current Shunt

1651 Keithley

OEM*, CEM

EURAMET,EA

ABNT or Internal

Procedures

Electrical Simulation of

Thermocouples5

Type B

Type C

Type E

Type J

Type K

(600 to 800) °C

(800 to 1 000) °C

(1 000 to 1 550) °C

(1 550 to 1 820) °C

(0 to 150) °C

(150 to 650) °C

(650 to 1 000) °C

(1 000 to 1 800) °C

(1 800 to 2 316) °C

(-250 to -100) °C

(-100 to -25) °C

(-25 to 350) °C

(350 to 650) °C

(650 to 1 000) °C

(-210 to -100) °C

(-100 to -30) °C

(-30 to 150) °C

(150 to 760) °C

(760 to 1 200) °C

(-200 to -100) °C

(-100 to -25) °C

(-25 to 120) °C

(120 to 1 000) °C

(1 000 to 1 372) °C

0.44 °C

0.34 °C

0.3 °C

0.33 °C

0.3 °C

0.26 °C

0.31 °C

0.5 °C

0.84 °C

0.5 °C

0.16 °C

0.14 °C

0.16 °C

0.21 °C

0.27 °C

0.16 °C

0.14 °C

0.17 °C

0.23 °C

0.33 °C

0.18 °C

0.16 °C

0.26 °C

0.4 °C

Fluke 5520A SC600

Page 8: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 8 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

Electrical Simulation of

Thermocouples5 (cont.)

Type L

Type N

Type R

Type S

Type T

Type U

(-200 to -100) °C

(-100 to 800) °C

(800 to 900) °C

(-200 to -100) °C

(-100 to -25) °C

(-25 to 120) °C

(120 to 410) °C

(410 to 1 300) °C

(0 to 250) °C

(250 to 400) °C

(400 to 1 000) °C

(1 000 to 1 767) °C

(0 to 250) °C

(250 to 1 000) °C

(1 000 to 1 400) °C

(1 400 to 1 767) °C

(-250 to -150) °C

(-150 to 0) °C

(0 to 120) °C

(120 to 400) °C

(-200 to 0) °C

(0 to 600) °C

0.37 °C

0.26 °C

0.17 °C

0.4 °C

0.22 °C

0.19 °C

0.18 °C

0.27 °C

0.57 °C

0.35 °C

0.33 °C

0.4 °C

0.47 °C

0.36 °C

0.37 °C

0.46 °C

0.63 °C

0.24 °C

0.16 °C

0.14 °C

0.56 °C

0.27 °C

Fluke 5520A SC600

OEM*, CEM,EA

ABNT or Internal

Procedures

Electrical Simulation of

RTDs5

Pt 395, 100 Ω

(-200 to -80) °C

(-80 to 0) °C

(0 to 100) °C

(100 to 300) °C

(300 to 400) °C

(400 to 630) °C

(630 to 800) °C

0.05 °C

0.05 °C

0.07 °C

0.09 °C

0.10 °C

0.12 °C

0.23 °C

Page 9: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 9 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

Electrical Simulation of

RTDs5 (cont.)

Pt 385, 200 Ω

Pt 385, 1000 Ω

Cu 427, 10 Ω

(-200 to -80) °C

(-80 to 0) °C

(0 to 100) °C

(100 to 260) °C

(260 to 300) °C

(300 to 400) °C

(400 to 600) °C

(600 to 630) °C

(-200 to -80) °C

(-80 to 0) °C

(0 to 100) °C

(100 to 260) °C

(260 to 300) °C

(300 to 400) °C

(400 to 600) °C

(600 to 630) °C

(-100 to 260) °C

0.04 °C

0.04 °C

0.04 °C

0.05 °C

0.12 °C

0.13 °C

0.14 °C

0.16 °C

0.03 °C

0.03 °C

0.04 °C

0.05 °C

0.06 °C

0.07 °C

0.07 °C

0.23 °C

0.3 °C

Fluke 5520A SC600

OEM*, CEM,EA

ABNT or

Internal

Procedures

Capacitance - Source

(1 kHz)

10 Hz to 10 kHz

10 Hz to 3 kHz

10 Hz to 1 kHz

10 Hz to 1 kHz

10 Hz to 1 kHz

(10 to 600) Hz

(10 to 300) Hz

(10 to 150) Hz

(10 to 120) Hz

(10 to 80) Hz

(0 to 50) Hz

(0 to 20) Hz

(0 to 6) Hz

(0 to 2) Hz

(0 to 0.6) Hz

(0 to 0.2) Hz

1 pF to 100 nF

(0.19 to 1.1) nF

(1.1 to 3.3) nF

(3.3 to 11) nF

(11 to 110) nF

(110 to 330) nF

330 nF to 1.1 µF

(1.1 to 3.3) µF

(3.3 to 11) µF

(11 to 33) µF

(33 to 110) µF

(110 to 330) µF

330 µF to 1.1 mF

(1.1 to 3.3) mF

(3.3 to 11) mF

(11 to 33) mF

(33 to 110) mF

0.50 F/F + 0.5 pF

5 mF/F + 10 pF

5 mF/F + 10 pF

2.5 mF/F + 10 pF

2.5 mF/F + 0.1 nF

2.5 mF/F + 0.3 nF

2.5 mF/F + 1 nF

2.5 mF/F + 3 nF

2.5 mF/F + 10 nF

4 mF/F + 30 nF

4.5 mF/F + 0.1 µF

4.5 mF/F + 0.3 µF

4.5 mF/F + 1 µF

4.5 mF/F + 3 µF

4.5 mF/F + 10 µF

7.5 mF/F + 30 µF

11 mF/F + 0.1 mF

Decade Capacitor 1413

Fluke 5520A SC600

Capacitance - Measure

at 1 kHz 0.00001 pF to 1 F 0.20 mF/F

RLC 1689 Digibridge

Quadtech

Page 10: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 10 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

Oscilloscopes

Amplitude - DC Signal

into 50 Ω Load

into 1 MΩ Load

Amplitude - Square wave

into 50 Ω Load

into 1 MΩ Load

Rise Time

Leveled Sine Wave

Relative to 50 kHz

Time Marker3

into 50 Ω Load

Wave Generator -

Amplitude

10 Hz to 10 kHz

Square, Sine, Triangle

into 1 MΩ Load

into 50 Ω Load

Frequency

0 V to ± 6.6 V

0 V to ± 130 V

±1 mV to ± 6.6 V p-p

(10 Hz to 10 kHz)

±1 mV to ± 130 V p-p

10 Hz to 1 kHz

(1 to 10) kHz

300 ps

5 mV to 5.5 V

50 kHz Reference

50 kHz to 100 MHz

(100 to 300) MHz

(300 to 600) MHz

5 s to 50 ms

20 ms to 100 ns

(50 to 20) ns

10 ns

(5 to 1) ns

1.8 mV to 55 V pp

1.8 mV to 2.5 V pp

10 Hz to 100 kHz

2,5 mV/V + 40 µV

0.50 mV/V + 40 µV

2.5 mV/V + 40 µV

1 mV/V + 40 µV

2.5 mV/V + 40 µV

+ 0 ps / -100 ps

20 mV/V + 0.30 mV

35 mV/V + 0.30 mV

40 mV/V + 0.30 mV

60 mV/V + 0.30 mV

(25 + 1 000t) µs/s

2.5 µs/s

2.5 µs/s

2.5 µs/s

2.5 µs/s

30 mV/V + 0.10 mV

30 mV/V + 0.10 mV

25 µHz/Hz + 15 mHz

Fluke 5520A SC600

OEM*, CEM,

EURAMET, IEE or

Internal

Procedures

DC Power - Source5

(33 mV to 1.02 kV)

(10.8 µW to 20.9 kW)

330 µA to 330 mA

330 mA to 3 A

(3 to 20.5) A

0.23 mW/W

0.22 mW/W

0.70 mW/W

AC Power - Source5

(10 to 65) Hz

1 mW to 99 W

100 W to 20 kW

(65 to 500) Hz

1 mW to 20 kW

500 Hz to 1 kHz

1 mW to 20 kW

(1 to 5) kHz

1 mW to 1.5 kW

0.15 mW/W

19 µW/W

19 µW/W

19 µW/W

8 mW/W

Page 11: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 11 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

DC Power - Measure

Up to 7.5 W

(7.5 to 30) W

(30 to 120) W

(120 to 750) W

750 W to 3 kW

(3 to 12) kW

3 mW/W + 23 mW

3 mW/W + 9 mW

3 mW/W + 0.36 W

3 mW/W + 2.3 W

3 mW/W + 9 W

3 mW/W + 36 W Yokogawa WT110

Digital Power Meter

OEM* ,CEM, IEE

or Internal

Procedures

AC Power - Measure

10 Hz to 5 kHz

Up to 7.5 W

(7.5 to 30) W

(30 to 120) W

(120 to 750) W

750 W to 3 kW

(3 to 12) kW

5 mW/W + 23 mW

5 mW/W + 9 mW

5 mW/W + 0.36 W

5 mW/W + 2.3 W

5 mW/W + 9 W

5 mW/W + 36 W

II. Electromagnetic - RF / Microwave6

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

RF Power - Source

into 50 Ω load

100 kHz to 3.2 GHz

(-120 to 13) dBm

(3.2 to 20) GHz

(-60 to 20) dBm

9 kHz to 3.2 GHz

-55 dBm

(-50 to -40) dBm

(-39 to 20) dBm

0.18 dB

0.18 dB

1.7 dB

0.6 dB

0.3 dB

Rohde & Schwarz

SMB 100A

RF Signal Generator

E8257D and

Agilent E4418B with

Power Sensors,

E9300A, E4412A

and E9304A H18

OEM*,CEM, IEE or

Internal

Procedures

RF Power - Measure

into 50 Ω load

10 MHz to 18 GHz

-55 dBm

-50 dBm to -40 dBm

(-40 dBm to + 20 dBm)

9 kHz to 6 GHz

(-60 dBm to +20 dBm)

1.7 dB

0.5 dB

0.19 dB

0.18 dB

Agilent E4418B

w/E9300A/E4412A

Sensor

Agilent E4418B

with E9304A H18

Page 12: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 12 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

RF Power - Source

into 50 Ω load

(0 to 100) W

(20 MHz to 1 GHz) 0.9 dB

RF Signal Generator

E8257D

RF Power Amplifier

Ophir 5300796 &

Ophir 5303031

Power Attenuator

PE7019-X, 40-3-43,

60-1-43

Power Meter E4418B with

Power Sensors, E9300A,

E4412A And E9304A H18

USB Power Sensor

NRP-Z91

OEM*,CEM, IEE or

Internal Procedures

RF Power - Measure

into 50 Ω load

(0 to 200) W

(20 MHz to 1 GHz) 0.9 dB

Power Attenuator

PE7019-X, 40-3-43,

60-1-43

Power Meter E4418B with

Power Sensors, E9300A,

E4412A And E9304A H18

USB Power Sensor

NRP-Z91

Page 13: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 13 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

III. Time and Frequency

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

Frequency - Source

Time Base @ 10 MHz

10 µHz to 1.64 GHz

(1.64 to 20) GHz

10 MHz

100 ns to 10 000 s

9 x 10-11

Hz/Hz

5 x 10-8

Hz/Hz

4 x 10-11

Hz/Hz

9 x 10-11

s/s

PTS-SG 1640

GPS Disciplined

Fluke 910 GPS Frequency

Standard

OEM* or

Internal Procedures

Frequency - Measure5

Time Base @ 10 MHz

1 Hz to 100 kHz

100 kHz to 225 MHz

225 MHz to 12.5 GHz

5.8 x 10-9

Hz/Hz

2.6 x 10-10

Hz/Hz

5.9 x 10-9

Hz/Hz

Agilent 53132A

enhanced with

Fluke 910A GPS (100 seconds gate time)

Agilent 53131A,

enhanced with

Fluke 910A GPS

OEM*CEM or

Internal Procedures

IV. Thermodynamic

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

Temperature -

Measure5

(-200 to 650) ºC

(650 to 1 000) ºC

(1 000 to 1 450) ºC

0.02 ºC

0.36 ºC

0.81 ºC

Fluke 8508A

and Hart 5626 PRT

Fluke 8508A and

5650 Type S

Thermocouple

OEM*,CEM, NPL

ISBN, ASME,

ASTM or Internal

Procedures

Temperature - Source5

0 ºC

(-30 to 650) ºC

(650 to 1 000) ºC

(1 000 to 1 450) ºC

0.01° C

0.13 ºC

2.7 ºC

2.2 ºC

Fluke 8508A with 5626

PRT, Dry Block Venus,

Water Triple Point Cell

Isotech B8/30/130

Fluke 8508A with 5626

PRT, Dry Block Venus,

Dry Block 9144

Fluke 8508A with

5650 Type S

Thermocouple,

Fluke 9150-A-156

Furnace 47900

Page 14: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 14 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

Relative Humidity

Humidity Chamber -

Measure

(11 to 80) % RH 1.1 %RH Vaisala HMI41/46

Humidity Chamber OEM*, CEM, ASME

NPL ISBN, ASTM

or Internal

Procedures Relative Humidity

Saturated Salts -

Source5

LiCl salt (11.3 %RH)

MgCl2 salt (32.8 %RH)

NaCl salt (75.4 %RH)

K2SO4 (97.4 %RH)

1.3 %RH

1.3 %RH

1.5 %RH

2.0 % RH

Vaisala Humidity

Calibrator HMK15 with

Saturated Salt Solutions

V. Mechanical

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

Balances/Scales5

(Resolution in

Parentheses)

Up to 300 g (0.0001 g)

300 g to 1 kg (0.001 g)

(1 to 6.5) kg (0.01 g)

(6.5 to 33) kg (0.1 g)

(33 to 50) kg (5 g)

(50 to 100) kg (10 g)

(100 to 200) kg (20 g)

(200 to 500) kg (50 g)

(500 to 1 000) kg (100 g)

(1 000 to 4 000) kg (200 g)

(4 000 to 5 000) kg (500 g)

0.24 mg

0.8 mg

9 mg

84 mg

4 g

8 g

20 g

40 g

80 g

0.2 kg

0.4 kg

Mass OIML Class E2,

F1 & M1

Mass ASTM E617

Class 1

ASTM E617-91 Class 6

& NIST 105-1

Class F Weights

OEM*, NIST

Handbook 44, OIML R

76-2, NTC 2031, SIM

Guidelines, CEM or

Internal Procedures

Mass - Measure

(1 to 500) mg

(1 to 20) g

50 g

100 g

200 g

300 g

500 g

1 kg

2 kg

5 kg

6 kg

10 kg

20 kg

50 lb

0.06 mg

0.07 mg

0.08 mg

0.1 mg

0.16 mg

0.24 mg

0.7 mg

1 mg

6 mg

14 mg

14 mg

63 mg

71 mg

71 mg

Electronic Comparators

Radwag XA310, Mettler

XS1003S,

A&D GX-6100 and

Vibra HJ-33KSE

with Mass ASTM

E617Class 1 and

OIML Class E2 & F1

OEM*,

NIST Handbook 44,

OIML-R111-2, NTC

1848, CEM, ASTM,

NTC or Internal

Procedures

Page 15: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 15 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

Air Flow (2.5 to 15) m/s

(492 to 2 953) FPM

0.12 m/s

24 FPM

Wind Tunnel

WTM-1000

Standard Anemometer

PAMB11

PRT with Readout 1522

OEM*,

IEC 61400-12-1 Annex

F, CEM, ASME,IEC or

Internal Procedures

Pressure5,

Absolute and Gauge

Mode

(0 to 6.9) kPa

(6.9 to 1 723) kPa

(1 723 to 6 894) kPa

(6 894 to 68 948) kPa

1 mPa/Pa + 3 Pa

172 Pa

80 µPa/Pa

0.2 mPa/Pa

Module 700P00 with

Fluke 754

ADT681-10-DP5-H2O

ADT681-05-DP20-H20

PAMB11

FLUKE RPM4

DHI RPM3

OEM*, OIML, ASME,

DKD R6-1,CEM,

OIML or Internal

Procedures

Vacuum5,

Absolute and Gauge

Mode

(-103 to 0) kPa

(-30 to 0) in·Hg

0,2 mPa/Pa

0,005 in·Hg

RPM4 A Mode

RPM3 A Mode,

Crystal IS33-

16/300PSI/SPSS

PAMB11

Force5 -

Source

Certified Mass

Up to 2 224 N 0.00026 N/N

Weight Classes

ASTM E617-91 Class 6

& NIST 105-1 Class F

OEM*,ASTM,

NIST Handbook 44,

NTC- ISO 7500-1,

CEM, OIML or Internal

Procedures

Force - Compression

and Weighing System

Source and Measure5

100 N to 100 kN

(100 to 445) kN

0.00034 N/N

0.00066 N/N

MGC plus ML38/AP03i

with Load Cells U9B

HBM, Z30A HBM, Z4A

HBM and C2P1 BLH OEM*, ASTM E74,

NTC/ISO 7500-1,

CEM, OIML or Internal

Procedures Force - Tension

Source and Measure5

100 N to100 kN

0.00034 N/N

MGC plus ML38/AP03i

with Load Cells U9B

HBM, Z30A HBM, Z4A

HBM

Page 16: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 16 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

Torque Transducer (0,014 to 2 712) N.m

2 oz·in to 2 000 lbf·ft 0.11 % of reading

NIST Class F Weights

with

2.5 in Radius Wheel,

5 in Radius Wheel,

10 in Radius Butterfly,

and 40 in Radius Arm OEM*, ASME

B107.300, DIN EN, ISO 6789, EURAMET/cg-14

CEM, OIML or Internal

Procedures

Torque Wrenches5

2 oz·in to 2 000 lbf·ft

(0.014 to 2 712) N.m

0.25 % of reading TTC2000 Torque

Calibrator Snap-On

Rotary Torque Tools5 (15 to 300) lbf·ft

(20 to 407) N.m 0.13 % of reading

Torque Tool Tester and

Impulse Rotary

Transducer

Norbar 43228

VI. Dimensional

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

Length (Source) 2,5

Calipers Outside.

Up to 24 in

(24 to 60) in

(Up to 609) mm

(320 + 7.0L) µin

(330 + 8.5L) µin

(8.1 + 0.0072L) µm

Gage Blocks Grade 0

OEM*, NTC, JIS,BS,

CEM, OIML,ASME

or Internal

Procedures

Length (Source) 2,5

Calipers Depth

Up to 12 in

(Up to 304) mm

(320 + 8.3L) µin

(8.1 + 0.0083L) µm

Gage Blocks Grade 0

Flatness Surface

Length (Source) 2,5

Calipers Inside

Up to 16 in

(Up to 609) mm

(320 + 7.0L) µin

(8.1 + 0,008L) µm

Gage Blocks Grade 0

Ceramic Micro Checker

515-586

Page 17: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 17 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

Length (Source) 2,5

Micrometers

Outside

Up to 1 in

(1 to 24) in

(24 to 40) in

Up to 25 mm

(25 to 609) mm

(5.7 + 7.0L) µin

(35 + 7.0L) µin

(190 + 7.0L) µin

(0.18 + 0.0071L) µm

(0.89 + 0.0071L) µm

Gage Blocks Grade 0

Optical Flat

OEM*, JIS,

BS, ASME B89, CEM,

OIML, BS or Internal

Procedures

Length (Source) 2,5

Micrometers

Inside.

Up to 16 in

Up to 600 mm

(42 + 7.0 L) µin

(1.4 + 0.007L) µm

Gage Blocks Grade 0

Ceramic Micro Checker

515-586

Hite Icator

OEM*, JIS,

BS, ASME B89, CEM,

OIML or Internal

Procedures

Length (Source) 2,5

Micrometers Depth,

Height, Dial Indicators

Up to 12 in

Up to 750 mm

(35 + 9.9 L) µin

(6.4 + 0.012 L) µm

Gage Blocks Grade 0

Depth Micro Checker

515-575

Granite Surface Plate

517-164

OEM*,

BS, ASME, CEM,

OIML or Internal

Procedures

Length (Source) 2,5

Dial Gage Tester

Up to 1 in

Up to 25 mm

(19 + 7.0 L) µin

(0.45 + 0.007 L) µm Gage Blocks Grade 0

OEM* ASME,

CEM, OIML or

Internal Procedures

Length (Source)5

Dial Indicators

Up to 1 in

Up to 25 mm

120 µin

3.0 µm

Dial Gage Tester

170-102M-2 and

170-101E

OEM*, NTC,ASME

BS , CEM, OIML or

Internal Procedures

Length - Measure5

Up to 1 in

(1 to 12) in

(12 to 48) in

Up to 25 mm

(25 to 101) mm

26 µin

1 200 µin

1 800 µin

1.2 µm

37 µm

Digimatic Micrometer

293-130

Digimatic Caliper

500 Series

OEM*, CEM,

OIML,ASME or

Internal Procedures

Length - Ruler Up to 36 in

Up to 1 000 mm

2 700 µin

160 µm

Standard Steel Ruler

Magnifying Glass

183-304

Granite Surface Plate

517-164

OEM*, CEM, OIML

or Internal Procedures

Length -

Flexometer

Up to 4 000 mm

(4 000 to 8 000) mm

(8 000 to 10 000) mm

0.95 mm

1.9 mm

2.9 mm

Standard Flexometer

CM182

Magnifying Glass

183-304

OEM*,CEM, ASME,

OIML, NOM-046

SCFI or Internal

Procedures

Page 18: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 18 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

Angle - Source

Clinometer, Level,

Protractor

(0 to 180) °

0.036 °

Mitutoyo Angle Blocks

981-102

Granite Surface Plate

517-164

Precision level

960-616

OEM* CEM, OIML,

ASME, DIN, NTC or

Internal Procedures

Angle5 - Measure

(0 to 180) ° 0.063°

Rank Taylor Hobson

Clinometer 142/42

Flatness5 (9.3 to 120) in

236 mm to 3 m

140 µin

3.5 µm

Flatness Gage LAP5

Flatness Reference

G-81703

Precision Level

960-616

OEM*, OIML, ASME,

BS,

CEM or Internal

Procedures

Holes 5

(0.011 to 0.5) in 130 µin C10P Meyer Gage

Makers Set Class Z

OEM* CEM, OIML,

DIN or Internal

Procedures

VII. ANSI/NCSL Z540-1-1994 Only (ISO/IEC 17025 Traceability Requirements Not Verified)

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

AC Phase Angle

- Measure

(0 to 180)° 10 Hz

50 Hz to 5 kHz

20 kHz

32 kHz

54 kHz

100 kHz

0.1 °

0.05 °

0.2 °

0.32 °

0.54 °

1 °

North Atlantic 2250

OEM* ,CEM, IEE or

Internal

Procedures Synchro Resolver

- Angle Source

Phase Shift (0 to 180) °

(2 to 115) V rms 47 Hz to 2 kHz (2 to 20) kHz

0.5 °

5 °

North Atlantic 5300

Phase Meter

Radial Bearing (0 to 340) ° 0.03 °

478A-3 Zifor III

Collins

Page 19: ANSI-ASQ National Accreditation Board/ACLASS · 2015. 1. 9. · 3458A (Amp) and Fluke 8508A (Volts) Defibrillator5 - Energy Source (10 to 360) J 1.4 J Fluke Impulse 7000 DP OEM*,

Version 009 Issued: 8/01/2014 Page 19 of 19

500 Montgomery St. Suite 625│ Alexandria, VA 22314│703-836-0025 │ www.aclasscorp.com

VII (cont.). ANSI/NCSL Z540-1-1994 Only (ISO/IEC 17025 Traceability Requirements Not Verified)

PARAMETER/

EQUIPMENT RANGE

CALIBRATION &

MEASUREMENT

CAPABILITY

[EXPRESSED AS

UNCERTAINTY(+)]

REFERENCE

STANDARD OR

EQUIPMENT

METHOD(S)

Distortion - Measure

100 mV to 130 V

(0 to 0.1) % THD

10 Hz to 500 kHz

500 kHz to 1 MHz

(0.1 to 2 ) % THD

10 Hz to 500 kHz

500 kHz to 1 MHz

(2 to 20) % THD

10 Hz to 500 kHz

500 kHz to 1 MHz

0.02 %

0.03 %

0.08 %

0.01 %

0.08 %

0.13 %

Krohn - Hite 6900B

OEM* ,CEM, IEE or

Internal

Procedures

Temperature - Infrared

Non-Contact5

(50 to 500) ºC 0.88 ºC Hart 9132

Blackbody Source

OEM*,CEM, NPL

ISBN, ASME,

ASTM or Internal

Procedures

Altitude/

Static Pressure

(RVSM Compliant)

(Ps) Altitude

(Pt) Airspeed

(-1 500 to 80 000) ft

(31.58 to 0.815) in·Hg

(25 to 1 000) KTS

(29 951 to 103 467)

in·Hg

0,003 in·Hg @ 0 ft

0,003 in·Hg @ 0 Knots

PPCM

18905810002

TVCS-9100

Kollsman

Pressure Indicator Dual

Channel PAMB11

OEM* or Internal

Procedures

Sound Pressure Level

Source

1 kHz

@ 0 dBa = 20 µPa

114 dBa or 94 dBa

0.5 dB Simpson 887-2

Sound Level Calibrator

OEM* CEM, OIML,

IEC or Internal

Procedures

Crimping Tools5

(0.025 to 0.072) in 44 µin

Digital Micrometer, C10P

Meyer Gage Makers Set

Class Z and

Go-No Go Gages

OEM* CEM, OIML,

ASME, DIN, NTC or

Internal Procedures

Notes: 1. Calibration and Measurement Capabilities (CMC) (Expanded Uncertainties) are based on approximately a 95% confidence interval, using a

coverage of k=2.

2. The use of (L) signifies an expression of Length in inches or mm depending on the unit system. 3. The use of (t) refers to Time in seconds.

4. OEM* (Original Equipment Manufacturer Procedure), CEM (Spanish metrology center procedure), OIML (Organization International of

Legal Metrology, ASME(American Society of Mechanical Engineer procedure), BS ( British standard), NTC (Colombian technical standard),EURAMET, EA(European standard), other XXX (standard from national or international metrological institutes)

5. This laboratory also offers this calibration service on-site at customer-designated locations. Since on-site conditions are typically more

variable than those in the laboratory, larger measurement uncertainties may be anticipated. 6. Uncertainties listed for Electromagnetic - RF/Microwave do not include possible contributions from mismatch error.

7. This scope is part of and must be included with the Certificate of Accreditation No AC-1327.