AccuLase Introduction Rapid Return-On-Investment · • Tunable Diode Laser (TDL) Technology •...

2
AccuLase Introduction Tunable Diode Laser (TDL) Technology Galvanic’s 6th Platform to Accurately Measure H 2 S Manufactured In & Supported From Calgary, AB Backed by 40 Years of Experience in Natural Gas Rapid Return-On-Investment Never Miss Unexpected Sour Event Spikes Guaranteed H 2 S Contractual Compliance Automate Custody Transfer Validation Avoid Pipeline “Lock-Out” From H 2 S Contamination Measurement Certainty 0.15 ppm LDL Rivals Tape Sensitivity Fast 30 Second Response Including SCS Multi-Stream Up to 4 Pipelines No Scrubber, No Consumables, No Interferences Minimal Hands-On Maintenance CSA Div. 1 & Div. 2 Applications Natural Gas Pipeline Custody Transfer Product Quality Monitoring Underground Storage Natural Gas Processing Plant Outlet Amine Absorber / Scavenger Outlet Refinery Fuel Gas (EPA) AccuLase-GPA™ 0.15 - 500 ppm H 2 S in Natural Gas [email protected] | +1 (403) 252-8470 | www.galvanic.com Rev. July 2019 | Specifications Subject to Change Without Notice AccuLase-GPA™

Transcript of AccuLase Introduction Rapid Return-On-Investment · • Tunable Diode Laser (TDL) Technology •...

Page 1: AccuLase Introduction Rapid Return-On-Investment · • Tunable Diode Laser (TDL) Technology • Galvanic’s 6th Platform to Accurately Measure H 2 S • Manufactured In & Supported

AccuLase Introduction• Tunable Diode Laser (TDL) Technology• Galvanic’s 6th Platform to Accurately Measure H2S• Manufactured In & Supported From Calgary, AB• Backed by 40 Years of Experience in Natural Gas

Rapid Return-On-Investment• Never Miss Unexpected Sour Event Spikes• Guaranteed H2S Contractual Compliance• Automate Custody Transfer Validation• Avoid Pipeline “Lock-Out” From H2S Contamination

Measurement Certainty• 0.15 ppm LDL Rivals Tape Sensitivity• Fast 30 Second Response Including SCS• Multi-Stream Up to 4 Pipelines• No Scrubber, No Consumables, No Interferences• Minimal Hands-On Maintenance

CSA Div. 1 & Div. 2 ApplicationsNatural Gas Pipeline• Custody Transfer • Product Quality Monitoring• Underground Storage

Natural Gas Processing• Plant Outlet• Amine Absorber / Scavenger Outlet

Refinery• Fuel Gas (EPA)

AccuLase-GPA™0.15 - 500 ppm H2S in Natural Gas

[email protected] | +1 (403) 252-8470 | www.galvanic.com Rev. July 2019 | Specifications Subject to Change Without Notice

AccuLase-GPA™

Page 2: AccuLase Introduction Rapid Return-On-Investment · • Tunable Diode Laser (TDL) Technology • Galvanic’s 6th Platform to Accurately Measure H 2 S • Manufactured In & Supported

AccuLase-GPA™ Processing, Pipeline, Custody Transfer

[email protected] | +1 (403) 252-8470 | www.galvanic.com Rev. July 2019 | Specifications Subject to Change Without Notice

No Scrubber No Purge or Instrument Air Utility

No Contamination Issues Secure Remote Analyzer AccessLarge Local Display

Multi-Stream

No Interference From Benzene, Methane, or CO2

No Temperature Drift