Page 1: 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 ... · 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 19:34 Page 1 This guide to Starbreaker consumer units is

StarbreakerAmendment 3Metal Cased

Skeleton Consumerunits for use inMeter Cabinets

211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 19:34 Page 1

Page 2: 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 ... · 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 19:34 Page 1 This guide to Starbreaker consumer units is

This guide to Starbreaker consumer units is not intended as a substitute for the standards and regulations that should always be used for all types of electrical installation design & installation work.

SKELETON CONSUMER UNITS FORUSE IN METER CABINETS

17th Edition Wiring Regulations IncorporatingAmendment No. 3: 2015

REGULATION 421.1.201

Amendment No. 3 to BS 7671 IET Wiring Regulations prescribes that within domestic(household) premises, consumer units and similar switchgear assemblies shall have theirenclosures manufactured from non combustible material, or be enclosed in a cabinet orenclosure constructed of non combustible materialand comply with product standard BS EN 61439-3.

What are Domestic Household Premises ? Typical Domestic household premises would include singleand multiple occupancy homes such as Houses, Bungalows,High Rise & Low Rise Flats, Apartments, Student lets,Sheltered Accommodation, Farmhouses, Houseboats, StaticHomes, Home Office, attached Garages, Workshops andDetached Summerhouses etc.

What is Non Combustible Material ?There are many types of non combustible material however,amendment 3 of the 17th Edition regulations provides anacceptable example as ferrous metal i.e. Steel ConsumerUnits.

What is an Enclosure ?The consumer unit enclosure must be manufactured from anon combustible material so as to limit the spread of fire. An enclosure means the box, cover, door, hinges, handle andany components required to maintain the integrity of the unit.

What is Similar Switchgear ?Similar switchgear is switchgear that is used for the samefundamental application ie. a circuit protection assembly withtwo pole isolator and one or more circuit protection devices,e.g. Skeleton consumer units, MCB distribution board, garageunit or PV switchgear etc.

What are Cabinets ?Typical cabinets are meter cabinets that are normally built into the fabric of the building that may or may not includeconsumer units within. Starbreaker all metal cased metercabinet consumer units are designed specifically for use inmeter cabinets that are unable to minimise flames escaping ormanufactured from combustible materials.

What about Cable Entry ?As usual good workmanship and proper materials should beapplied to all installation work, consumer units must beinstalled to achieve IP4X on the top elevation (regulation416.2.2) and IP2XC on all other elevations. This can beachieved by use of cable entry accessories or other meanssuch as glanding.

211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 19:34 Page 2

Page 3: 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 ... · 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 19:34 Page 1 This guide to Starbreaker consumer units is

SKELETON CONSUMER UNITS FORUSE IN METER CABINETS

17th Edition Wiring Regulations IncorporatingAmendment No. 3: 2015

l Low Smoke & Fume paint

l Top hinged self closing, stay shut door &metal hinges

l Cable entry on 3 sides & large squareknockouts on the rear

l Mains tails cable entry gland forsupplementary insulation similar to ClassII level of protection to tails

l Non combustible cover blanks forunused ways

l Flame retardant cable entry grommets

l RoHS compliant in excess of UKstandards

l Finger safe, insulated busbar assembly -provides greater personal protection

l Permanent factory fitted, non removablebusbar shield - can’t be lost or left out

l Plug in MCB & RCBO 25% fewer screwterminals to make - significantly reducingrisk of loose connections

l Add or upgrade circuits withoutremoving busbar - no need to disturbadjacent devices - reducing risk of looseconnections

l Extra height for added wiring space withsingle module RCBOs

l DIN control devices can be fitted in anyposition along the DIN rail - withoutaffecting any other devices or busbarconnections

l Factory fitted incoming devices forreduced installation time

543 MTCG32 CRCE1 or CRCE2

l Complies with requirements of BS 7671Amenendment 3

l UKAS certified to BS EN 61439-3

l Full metal enclosure, no exposed plastic parts

SPACE FORCUT OUT FUSE

AND REC METER

211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 19:34 Page 3

Page 4: 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 ... · 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 19:34 Page 1 This guide to Starbreaker consumer units is

SKELETON CONSUMER UNITS FOR USE IN DOMESTIC HOUSEHOLD PREMISES17th Edition Wiring Regulations Including Amendment No. 3

REGULATIONS RELATING TO: EXAMPLES

Upstairs Sockets Downstairs Sockets Kitchen Sockets Cooker outlet with integral 13A socket Garage Sockets Plus any other sockets up to 20A rated

Shower circuit Lighting circuit Heating circuit Ventilation circuit Shaver Socket Plus Other circuits

Downstairs Lighting Upstairs Lighting Immersion heater Smoke Alarms Burglar Alarm (Safety service) Plus any other circuits

Mains tails should be protected at the point of entry into the metal enclosure by use of a mains tails gland to protect against the possibility ofmechanical damage and or disturbance that could lead to tails becoming loose and making contact with the metal enclosure.

* Regulation 411.3.3 socket outlets with a rated current not exceeding 20A. ** Regulation 701.411.3.3 Additional protection shall be provided for all circuits of the location by use of one or more 30mA RCD.*** Regulations in the 522.6.200 series cables concealed in a wall or partition at less than 50mm depth and without earthed mechanical protection

e.g. conduit.**** Regulation 314.1 Every installation shall be divided into circuits as necessary to avoid danger and inconvenience in the event of a fault, take

account of danger that may arise from the failure of a single circuit such as a lighting circuit, reduce the possibility of unwanted tripping of RCDsetc.

**** Regulation 314.2 Separate circuits to be provided for parts of the installation that need to be separately controlled in such a way that thosecircuits are not affected by the failure of other circuits.

***** Regulation 560.7.1 Chapter 56 circuits for safety services shall be independent of other circuits. In addition Chapter 51 requires designers/ installers to take account of all relevant British Standards and manufacturers instructions. For example

BS5839 Part 6 is the British Standard for fire detection and alarm systems in dwellings. It states that power supplies to Grade D smoke alarmsshould be an independent circuit at the consumer unit, or a separately electrically protected local lighting circuit.

****** Regulation 416.2.2 requires that the installed consumer unit achieves IP4X (1mm probe) on the top elevation. All other elevations should beto IP2XC (2.5mm probe).

ADDITIONAL PROTECTION

30mA RCD

30mA RCDs

30mA RCD

411.3.3*

701.411.3.3**

522.6.200 series***and

560.7.1*****

Sockets up to20A rating

Taking into account314.1 ****314.2 ****

Taking into account314.1 ****314.2 ****

Taking into account314.1 ****314.2 ****

All Circuits serving orpassing through a roomwith a fixed bath orshower

All circuits buried ina wall or partition atless than 50mm andwithout mechanicalprotection

A typical domestic household application with meter cabinets

Amendment No3 has brought about the requirement for ‘all metal’ non combustible enclosures for consumer units and similar switchgear.

This is in addition to the requirements for Additional Protection (30mA RCD) as summarised below.

lAll socket outlets should be protected by 30mA RCDl All circuits serving or passing through a room with a fixed bath orshower should be protected by one or more 30mA RCDs**

l All cables buried beneath the plaster surface of the wall or partition(at less than 50mm) should be protected by 30mA RCDs***

l All cables concealed in metal stud partitions (common in newbuilds) should be protected by 30mA RCDs***

l Installations should be divided up into circuits so as to take accountof danger and inconvenience caused by a single fault - e.g. such as alighting circuit***

l Installations should be designed and arranged so as to preventunwanted tripping of RCDs***

l Safety services such as smoke alarms should be on independentcircuits****

l Installed units must be to IP4X on top elevation & IP2XCelsewhere******

A

17

thE

DIT

ION

WIR

ING

RE

GU

LAT

ION

S I

NC

LUD

ING

AM

EN

DM

EN

T N

o.3

211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 19:35 Page 4

Page 5: 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 ... · 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 19:34 Page 1 This guide to Starbreaker consumer units is

SKELETON CONSUMER UNITS FOR USE IN DOMESTIC HOUSEHOLD PREMISES17th Edition Wiring Regulations Including Amendment No. 3

ALL INDEPENDENT CIRCUITSFull metal Main Switch unit with RCBOs

30mA Earth leakage protection

Illustrations are of 320mm wide units (up to 10 ways) 430mm wide units (up to 13 ways) and 273mm units (7 ways) are also available

A

SOME INDEPENDENT CIRCUITSFull metal High Integrity unit with RCBOs and MCBs

A

HALF INDEPENDENT CIRCUITSFull metal Split Load unit with RCBOs and MCBs

A

NO INDEPENDENT CIRCUITSFull metal Dual RCD unit with MCBs

A

211574 Crabtree Starbreaker skel 8pp (Q10).qxp 04/02/2016 14:20 Page 5

Page 6: 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 ... · 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 19:34 Page 1 This guide to Starbreaker consumer units is

STARBREAKER METAL CASED SKELETON UNITS - 273mm WIDE FIXING CENTRES lDESCRIPTION LIST No

MAIN SWITCH METAL CASED SKELETON UNITS

7 Way Main Switch Unit 607/2B

● 100A DP Main Switch

18ME08

STARBREAKER METAL CASED SKELETON UNITS - 320mm WIDE FIXING CENTRES lDESCRIPTION LIST No

MAIN SWITCH METAL CASED SKELETON UNITS

10 Way Main Switch Unit 610/2B

SPLIT LOAD METAL CASED SKELETON UNITS

8 Way Split Load Unit, 4+4 608/2483B

HIGH INTEGRITY METAL CASED UNITS

6 Way High Inegrity Unit, 2+2+2 606/228282B

DUAL RCD METAL CASED SKELETON UNITS

6 Way Dual RCD Unit, 3+3 606/2833833B

● 100A DP Main Switch● All RCDs have an 80A 30mA rating

xxx

STARBREAKER METAL CASED SKELETON UNITS - 430mm WIDE FIXING CENTRES lDESCRIPTION LIST No

MAIN SWITCH METAL CASED SKELETON UNITS

13 Way Main Switch Unit 613/2B

SPLIT LOAD METAL CASED SKELETON UNITS

11 Way Split Load Unit, 5+6 611/2583B

HIGH INTEGRITY METAL CASED UNITS

9 Way High Integrity Unit, 1+4+4 609/218484B

DUAL RCD METAL CASED SKELETON UNITS

9 Way Dual RCD Unit, 5+4 609/2835834B

● 100A DP Main Switch● All RCDs have an 80A 30mA rating

xxx

STA

RB

RE

AK

ERAMENDMENT 3 SKELETON CONSUMER UNITS & O

UTGOING DEVICES

61/B06 61/B10 61/B16 61/B20 61/B32 61/B40 61/B50

MINIATURE CIRCUIT BREAKERS l LIST NoRATING MODULES Type B Type C6A 1 61/B06 61/C0610A 1 61/B10 61/C1016A 1 61/B16 61/C1620A 1 61/B20 61/C2032A 1 61/B32 61/C3240A 1 61/B40 61/C4050A 1 61/B50 61/C50

● BSEN 60898 6kA – 240V 50Hz.● Type B classification (3–5In). Type C classification (5–10In).● 25mm2 terminal capacity.

211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 19:36 Page 6

Page 7: 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 ... · 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 19:34 Page 1 This guide to Starbreaker consumer units is

STA

RB

REA

KEROUTGOING DEVICES, A

CCESSORIES & BELL T

RANSFO

RMERS TIM

E SWITCHES

RCBOs Type B and Type C

RESIDUAL CURRENT CIRCUIT BREAKERWITH OVERCURRENT PROTECTION (RCBOs) l LIST NoRATING MODULES 30mA Type B 30mA Type C6A 1 61/B10630 61/C1063010A 1 61/B11030 61/C1103016A 1 61/B11630 61/C1163020A 1 61/B12030 61/C1203032A 1 61/B13230 61/C1323040A 1 61/B14030 61/C1403050A 1 61/B15030 61/C15030

● EN 61009-1, IEC61009-1.● 230 (240)V AC 50/60 Hz.● 16mm2 terminal capacity.CAUTIONThese devices are electronic units and should be disconnected from the supply duringinsulation and earth fault loop impedance testing.

301/TD1 302/TD2

301/TQ24 303/TQ7

DIGITAL TIMESWITCHES lDESCRIPTION MOD LIST No1 Channel Digital Timeswitch 1 301/TD11 Channel Digital Timeswitch 2 302/TD12 Channel Digital Timeswitch 2 302/TD21 Channel Digital Timeswitch + data key facility 2 402/TD12 Channel Digital Timeswitch + data key facility 2 402/TD21 Channel Digital Astro Timeswitch + data key facility 2 502/TD12 Channel Digital Astro Timeswitch + data key facility 2 502/TD21-10 min Staircase Timeswitch 1 301/S10Software USB/SData Key 4/5DKData Key 6DK

ANALOGUE TIMERS lDESCRIPTION MODULES LIST No24hr Analogue Quartz 1 301/TQ2424hr Analogue Quartz 3 303/TQ247 Day Analogue Quartz 3 303/TQ724hr Analogue Synchronous 1 301/TS1124hr Analogue Synchronous 3 303/TS24

303/B12

BELL TRANSFORMER lDESCRIPTION MODULES LIST No12V bell transformer 2 303/B12

● With overload protection.

ACCESSORIES lMetal Blanking Plate 543MCB Padlocking Device MCBLDUniversal Adaptor* MTCG32

* As recommended in the IET On Site Guide

543 MCBLD MTCG32

MEMBRANE CABLE ENTRIES KIT (FLAME RETARDENT) l7 x 20mm & 3 x 32mm CRCE110 x 20mm CRCE2

CRCE1

211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 19:37 Page 7

Page 8: 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 ... · 211574 Crabtree Starbreaker skel 8pp (Q10).qxp 03/02/2016 19:34 Page 1 This guide to Starbreaker consumer units is

ELECTRIUM SALES LIMITED A SIEMENS COMPANYCommercial Centre, Lakeside Plaza, Walkmill Lane, Bridgtown, Cannock WS11 0XE.

eMail: [email protected] Web: www.electrium.co.uk Twitter: follow@ElectriumNews

UK SALESTelephone: 01543 455010 Facsimile: 01543 455011 eMail: [email protected]

TECHNICALTelephone: 01543 438310 Facsimile: 01543 438311 eMail: [email protected]

EXPORT SALESTelephone: +44 1543 455049 Facsimile: +44 1543 455048 eMail: [email protected]

Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication,specifications and performance data are constantly changing. Latest details can be obtained from Crabtree.

Publication No. A2278 1/16Printed in England.