2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

141
2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077 LARRY LEHMAN, KEVIN KALAKAY DAN O’DONNELL, AND BOB KONYNDYK INSTRUCTOR NO.’s 300, 1378, 1681, 008 EFFECTIVE DATE: March 9, 2011

description

2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077 LARRY LEHMAN, KEVIN KALAKAY DAN O’DONNELL, AND BOB KONYNDYK INSTRUCTOR NO.’s 300, 1378, 1681, 008 EFFECTIVE DATE: March 9, 2011. R101.2 Scope. Detached 1 & 2 Family Dwellings - PowerPoint PPT Presentation

Transcript of 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

Page 1: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

2009 RESIDENTIAL CODE COMPLETE UPDATE4 HOURS TECHNICAL

ALL CLASSIFICATIONSCOURSE NUMBER 16077

LARRY LEHMAN, KEVIN KALAKAYDAN O’DONNELL, AND BOB KONYNDYKINSTRUCTOR NO.’s 300, 1378, 1681, 008

EFFECTIVE DATE: March 9, 2011

Page 2: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

2

R101.2 Scope

• Detached 1 & 2 Family Dwellings

• Townhouses not more than 3 stories above grade plane with a separate means of egress

• Their accessory structures

• Live/ work units complying with sec. 419 of MBC

Page 3: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

3

80.1 Scope Michigan Electrical Code Rules Part 8

• The code regulates the design, installation, maintenance, alteration, and inspection of electrical systems including all wiring, fixtures, appliances, and appurtenances in connection with the utilization of electrical energy, within or on a building, structure, or properties, and including service entrance wiring as defined by the code.

• Exception: Electrical wiring and equipment within 1- and 2-family dwellings shall be constructed, installed, and maintained in accordance with the Michigan residential code.

Page 4: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

4

Electrical Code Advisory

• Evaluate every code section and compare the intent with the National Electrical Code

• Include sections from the NEC that are not in the Michigan Residential Code

• Appendix Q

• Proposals

Page 5: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

5

E3401.3 Not Covered

Not covered. Chapters 34 to 43 do not cover the following:

(1) Installations including associated lighting under the exclusive control of communications utilities and electric utilities.(2) Services over 400 amperes.

Page 6: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

6

E3402.2 Penetration of Rated Walls

Penetrations of fire-resistance-rated assemblies. Electrical installations in hollow spaces, vertical shafts, and ventilation or air-handling ducts shall be made so that the possible spread of fire or products of combustion will not be substantially increased. Electrical penetrations through fire-resistance-rated walls, partitions, floors, or ceilings shall be protected by approved methods to maintain the fire-resistance-rating of the element penetrated. Penetrations of fire-resistance-rated walls shall be limited as specified in Section 317.3 R302.4.

Page 7: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

7

E3403.3 Listing and Labeling

• Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

• (Deleted IRC wording replaced with NEC wording)

• Electrical materials, components, devices, fixtures and equipment shall be listed for the application, shall bear the label of an approved agency and shall be installed, and used, or both, in accordance with the manufacturer's installation instructions.

Page 8: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

8

E3405.4 Working Space

Location of working spaces and equipment. Required working space shall not be designated used for storage. Panelboards and overcurrent protection devices shall not be located in clothes closets, in bathrooms, or over steps of a stairway.

Page 9: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

9

E3406.7 Conductors of Same Circuit

Conductors of the same circuit. All conductors of the same circuit and, where used, the grounded conductor and all equipment grounding conductors and bonding conductors shall be contained within the same raceway, trench, cable, or cord.

Page 10: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

10

E3407.5 Polarity

Polarity of connections. No grounded conductor shall be attached to any terminal or lead so as to reverse the designated polarity.

(Added this section from NEC 200.11)

Page 11: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

11

E3601.6.3 Space Conditioning Equipment

Separate outdoor electric space conditioning equipment. A service disconnect for separately metered outdoor electric space conditioning equipment may be located immediately adjacent to the outdoor meter cabinet. A permanent plaque or directory shall be installed at each service disconnect location denoting the other services, feeders, and branch circuits supplying a building or structure and area served by each service, feeder, and branch circuit.

Page 12: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

12

Electric Vehicle Charging

Page 13: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

13

E3601.6.4 Electric Vehicle Charging

Electric vehicle charging system service disconnect. A separate disconnect for electric vehicle charging systems shall be permitted. The disconnect shall be located immediately adjacent to the outdoor meter cabinet. A permanent plaque or directory shall be installed at each service disconnect location identifying the other services, feeders, and branch circuits supplying a building or structure and area served by each service, feeder, and branch circuit. The disconnect shall not be required to be grouped with the service disconnects for the structure.

Page 14: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

14

E3601.6.4 Electric Vehicle Charging (con’t)

Page 15: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

15

E3601.6.4 Electric Vehicle Charging (con’t)

Option 1

Page 16: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

16

E3601.6.4 Electric Vehicle Charging (con’t)

Option 2

Page 17: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

17

E3601.6.4 Electric Vehicle Charging (con’t)

Option 3

Page 18: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

18

E3601.6.4 Electric Vehicle Charging (con’t)

Option 4

Page 19: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

19

E3607.3 Grounding for Buildings Supplied by Feeders

For other than existing wiring systems, the code no longer permits feeders or branch circuits without an equipment grounding conductor to serve separate buildings.

• E3607.3 Buildings or Structures Supplied by Feeder(s) or Branch Circuit(s).

• E3607.3.1 Equipment Grounding Conductor.• E3607.3.2 Grounded Conductor, Existing Premises.

Previously, the code permitted the common practice of installing a three-wire feeder to a detached accessory building without an equipment grounding conductor. In effect, the grounded conductor also served as the grounding conductor. Except for existing wiring systems, this practice is no longer allowed.

Page 20: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

20

E3607.3 Grounding for Buildings Supplied by Feeders (con’t)

Page 21: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

21

E3608.1 Grounding Electrodes

For concrete-encased electrodes, the code clarifies the location of horizontal and vertical installations and stipulates that only one such electrode needs to be connected to the grounding electrode system. The provisions for rod and pipe electrodes have been revised to clarify the material, dimensions, and listing requirements. A new section recognizes other listed grounding electrodes.

• E3608.1.2 Concrete-Encased Electrode

Page 22: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

22

E3608.1 Grounding Electrodes (con’t)

• E3608.1.4 Rod and Pipe Electrodes. Rod and pipe electrodes not less than 8 feet in length and consisting of the following materials shall be considered as a grounding electrode.

• E3608.1.6 Other Electrodes. In addition to the grounding electrodes specified in Sections E3608.1.1 through E3608.1.5 other listed grounding electrodes shall be permitted.

Page 23: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

23

E3609.3 Intersystem Bonding Termination

Bonding terminations for communications, satellite, and cable television grounding conductors are now required in one of three prescribed and accessible locations.

Page 24: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

24

E3609.7 Bonding Metal Piping

Bonding other metal piping. Where installed in or attached to a building or structure, a metal piping system, including gas piping, capable of becoming energized shall be bonded to the service equipment enclosure, the grounded conductor at the service, the grounding electrode conductor where of sufficient size, or to the 1 or more grounding electrodes used.

Page 25: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

25

E3609.7.1 Bonding Metal Piping (con’t)

Other than corrugated stainless steel tubing (CSST). The bonding jumper shall be sized in accordance with table 3908.12 using the rating of the circuit capable of energizing the piping. The equipment grounding conductor for the circuit that is capable of energizing the piping may serve as the bonding means.

Page 26: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

26

• CSST • Corrugated Stainless• Steel Tubing• Bonding Concerns with

Flexible Metal Gas Piping• There have been lawsuits

due to fires with CSST gas piping systems and the major concern is the proper bonding of these systems and lightning. Gastite has issued a Technical Bulletin and requires bonding in excess of current NEC requirements.

E3609.7.1 Bonding Metal Piping (con’t)

Page 27: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

27

E3609.7.1 Bonding Metal Piping (con’t)

Page 28: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

28

E3609.7.1 Bonding Metal Piping (con’t)

Page 29: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

29

E3609.7.2 Bonding Metal Piping (con’t)

Corrugated stainless steel tubing (CSST). Corrugated stainless steel tubing gas piping systems shall be bonded by connection to a metallic piping segment or fitting, either outside or inside the building, between the individual gas meter and the first CSST fitting. The bonding jumper shall be sized in accordance with Table E3603.1 based on the size of the service-entrance conductor or feeder supplying each occupancy and as permitted in Table E3603.1 note (d) but not smaller than 6 American Wire Gauge (AWG) copper (or equivalent).

Page 30: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

30

E3705.7 Location of Overcurrent Devices

• E3705.7 Location of Overcurrent Devices in or on Premises.

5. Not be located over steps of a stairway.

Page 31: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

31

E3803.6 Raceway Seals

• Raceway seals. Conduits or raceways shall be sealed or plugged at either or both ends where moisture will enter and contact live parts. Sealants shall be identified for use with the cable insulation, shield, or other components.

• (300.5 (G) Raceway Seals)

Page 32: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

32

Raceway Seals (con’t)

Page 33: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

33

E2803.9 Earth Movement

Where direct buried conductors, raceways, or cables are subject to movement by settlement or frost, direct buried conductors, raceways, or cables shall be arranged to prevent damage to the enclosed conductors or to equipment connected to the raceways.

Page 34: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

34

300.5(J) Ground Movement

Page 35: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

35

E3901 Required Receptacle Outlets

Receptacle outlets that are controlled by a wall switch are no longer counted as contributing to the required receptacle distribution in the specified rooms or areas.

• E3901.1. General.

3. Controlled by a wall switch in accordance with Section E3903.2, Exception 1

Page 36: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

36

E3901.7 Outdoor Outlets

A receptacle outlet is now required for each balcony, deck, or porch 20 square feet or greater in area.

Page 37: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

37

E3902.11 Arc-Fault Protection

• E3902.11 Arc-Fault Circuit-Interrupter Protection.

• Additional provisions for AFCI protection have been removed from the 2009 MRC.

Page 38: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

38

E3902.11 Arc-Fault Protection (con’t)

Arc-fault protection of bedroom outlets.  All branch circuits that supply 120-volt, single-phase, 15- and 20-ampere outlets installed in bedrooms shall be protected by a combination type arc-fault circuit interrupter installed to provide protection of the entire branch circuit.

Page 39: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

39

E3902.11 Arc-Fault Protection (con’t)

• Exception:  The location of the arc-fault circuit interrupter shall be permitted to be at other than the origination of the branch circuit provided that:

• 1.  The arc-fault circuit interrupter is installed within 6 feet (1.8 m) of the branch circuit overcurrent device as measured along the branch circuit conductors and

• 2.  The circuit conductors between the branch circuit overcurrent device and the arc-fault circuit interrupter are installed in a metal raceway or a cable with a metallic sheath.

Page 40: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

40

E4002.14 Tamper-Resistant Receptacles

The code now requires listed tamper-resistant receptacles for all 125-volt 15- and 20-ampere receptacles installed in dwelling units, on the outside of dwelling units, and in attached and detached garages.

• E4002.14 Tamper-Resistant Receptacles.

Page 41: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

41

E4002.15 Replacement of Receptacles

• Replacement of receptacles shall comply with the following as applicable.

• This change coordinates with the Michigan Electrical Code.

Page 42: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

42

E4003.12 Luminaires in Clothes Closets

Recessed or surface-mounted LED luminaires are now permitted in locations approved for incandescent luminaires. Surface-mounted LED and fluorescent luminaires may be installed within the defined storage area when the luminaire is specifically identified as suitable for such use.

Page 43: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

43

E4203.3 Disconnecting Means for Pools, Spas, and Hot Tubs

The required disconnecting means for pools, spas, and hot tubs must simultaneously disconnect all ungrounded conductors and be located not less than 5 feet from the water’s edge.

• E4203.3 Disconnecting Means.

Page 44: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

44

E4206.5.1 Servicing of Wet-Niche Luminaires

Revisions to Section E4206.5.1 clarify that wet-niche luminaires must be installed such that all maintenance can be performed on the pool deck.

• E4206.5.1 Servicing.

Page 45: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

45

E4209.1 Hydromassage Bathtubs

Hydromassage bathtubs are now required to be on an individual branch circuit. The required ground-fault circuit-interrupter (GFCI) device must be readily accessible.

• E4209.1 Ground-Fault Circuit Interrupters.

Page 46: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

46

M1305.1.4.1 Ground Clearance

Equipment and appliances supported from the ground shall be level and firmly supported on a concrete slab or other approved material extending not less than 3 inches above the adjoining ground. Such support shall be in accordance with the manufacturer’s installation instructions. Appliances suspended from the floor shall have a clearance of not less than 6 inches from the ground.

Page 47: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

47

M1307.3.1 Protection from Impact

Appliances shall not be installed in a location subject to vehicle damage except where protected by approved barriers.

Page 48: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

48

M1502 Clothes Dryer Exhaust

Dryer exhaust duct installation under the 2009 IRC focuses primarily on the dryer manufacturer’s installation instructions. The code clarifies the provisions for duct materials and installation to reflect current industry practices. Equivalent lengths for fittings appear in a new table and are based on the radius and type of fitting. When a concealed exhaust system with a length greater than 25 feet is installed in accordance with the dryer manufacturer’s installation instructions, the developed length must be identified with a permanent marker. New provisions require protection of the dryer duct against penetration by drywall fasteners.

Page 49: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

49

M1502 Clothes Dryer Exhaust (con’t)

• M1502.1 General. Clothes dryers shall be exhausted in accordance with the manufacturer’s instructions.

Page 50: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

50

M1503.4 Makeup Air for Kitchen Exhaust Hoods

A new Section M1503.4 requires makeup air for kitchen exhaust hoods with a rating greater than 400 cfm. The makeup air system must be synchronized with the operation of the exhaust hood.

• M1503.4 Makeup Air Required.

Page 51: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

51

M1601.3 & M1601.4 Duct Insulation Materials and Duct Installation

The code adds an alternative testing method for determining flame spread and smoke-developed indices of duct insulation materials. Spray-applied polyurethane foam insulation is now recognized for the insulation and sealing of ducts in specific attic and crawl space applications. Changes to the provisions for connecting and sealing ducts clarify their application.

Page 52: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

52

M1601.6 Independent Garage HVAC Systems

New language clarifies that an HVAC system is not permitted to serve both the dwelling unit and the garage.

Page 53: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

53

M1602.2 Prohibited Sources of Outdoor and Return Air

Unconditioned attics and crawl spaces are now specifically prohibited as sources of outdoor or return air for HVAC systems.

Page 54: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

54

M1701 Combustion Air

• Chapter 17, “Combustion Air”, Sections M1701.1.1 through M1703.5, Figures M1702.2 through M1703.3, and three associated definitions of Section R202 have been deleted without substitution. The remaining Section M1701.1 references the combustion air requirements of the manufacturer for solid-fuel-burning appliances and of NFPA 1 for oil-fired appliances. Prescriptive methods for providing combustion air to gas-fired appliances are found in IRC Chapter 24.

Page 55: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

55

M1905 General

• Solid fuel burning equipment shall be listed and labeled in accordance with section M1302.1, installed in accordance with the manufacturers installation instructions and NFPA 211-2006

• R-408.30541

Page 56: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

56

M2103.2 Hydronic Floor Heating Systems

Hydronic radiant floor heating systems now require thermal insulation installed below the piping or tubing. The R-value marking on the insulation must be visible before finish materials are installed. A thermal break is required between a heated slab and the foundation.

Page 57: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

57

M2104 Hydronic Piping Materials

The 2009 IRC recognizes two new polyethylene materials and their associated fittings for hydronic piping.

• M2104.3 Raised Temperature Polyethylene (PE-RT) Plastic Tubing. Joints between raised temperature polyethylene tubing and fittings shall conform to Sections M2104.3.1 and M2104.3.2. Mechanical joints shall be installed in accordance with the manufacturer’s instructions.

Page 58: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

58

M2104 Hydronic Piping Materials (con’t)

Page 59: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

59

G2408.2.1 & G2408.6 Appliance Installation in Garages

Elevation of the ignition source is not required for gas-fired appliances installed in an enclosed space that does not open into the garage. A new provision requires appliances to be installed and connected in a way that does not strain the gas piping connections.

• G2408.2.1 (305.3.1) Installation in Residential Garages.

• G2408.6 (305.12) Avoid Strain on Gas Piping.

Page 60: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

60

G2415.4 Underground Penetrations Prohibited

Gas piping is no longer permitted to penetrate the foundation wall below ground.

Page 61: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

61

G2415.6 Piping in Solid Floors

When both ends of a protective conduit installed in a slab terminate inside the building, the code now prohibits the ends from being sealed. For installations where one end of the conduit terminates outside the building, the interior end must be sealed and the exterior end must prevent entry of water and insects and be vented to the outdoors.

• G2415.6 (404.6) Piping in Solid Floors.

Page 62: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

62

G2415.6 Piping in Solid Floors (con’t)

Page 63: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

63

G2415.12 Piping Underground Beneath Buildings

This change expands the installation requirements for gas piping encased by a conduit and installed beneath buildings. Where both ends of the protective conduit occur inside the building, the code now prohibits sealing of the conduit.

• G2415.12 (404.12) Piping Underground Beneath Buildings.

• G2415.12.1 (404.12.1) Conduit with One End Terminating Outdoors.

• G2415.12.2 (404.12.2) Conduit with Both Ends Terminating Indoors.

Page 64: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

64

G2420.5 Appliance Shutoff Valve

Section G2420.5 has been reorganized to clarify the shutoff valve location requirements.

• G2420.5 (409.5) Appliance Shutoff Valve.• G2420.5.1 (409.5.1) Located Within Same Room.• G2420.5.2 (409.5.2) Vented Decorative Appliances

and Room Heaters.• G2420.5.3 (409.5.3) Located at Manifold.

The fuel gas provisions of the IRC requires shutoff valves to permit the servicing and replacement of appliances without the need to shut down the entire gas supply system. These valves are not considered emergency shutoff valves.

Page 65: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

65

G2420.5 Appliance Shutoff Valve (con’t)

Page 66: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

66

G2422.1.2.1 Maximum Length of Connectors

The maximum length of connectors has increased from 3 feet to 6 feet.

• G2422.1.2.1 (411.1.3.1) Maximum Length.

Page 67: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

67

G2439.5 Clothes Dryer Ducts

The reorganization of this section clarifies the code provisions for clothes dryer ducts. Except where determined by the manufacturer’s installation instructions, the maximum prescribed length for gas dryer exhaust ducts has increased from 25 feet to 35 feet.

• G2439.5 (614.6) Domestic Clothes Dryer Exhaust Ducts.

Page 68: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

68

G2439.5 Clothes Dryer Ducts (con’t)

Page 69: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

69

G2447.5 Vertical Clearance Above Cooking Top

Clearance requirements for household cooking appliances have been added to the fuel gas provisions of the 2009 IRC. In general, kitchen wall cabinets must be positioned at least 30 inches above the surface of the range or cook top.

Page 70: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

70

R202 Definitions

Story above Grade Plane. Any story having its finished floor surface entirely above grade plane, except that a basement shall be considered as a story above grade plane.

Page 71: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

71

• Exception: Live/work units

• Nonresidential less than 50%

• Maximum 5 workers

• Storage area 10% or less

• Maximum 3,000 sq. feet

2009 Code: R101.2 Scope

Page 72: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

72

R106.3.1 Approval of Construction Documents

REVIEWED FOR CODE COMPLIANCE

Page 73: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

73

• The definitions of agricultural or agricultural purposes and building inspector are added to the code and the definitions of building, building officials, registered design professional.

• Attic, Habitable. A finished or unfinished area, not considered a story, complying with all of the following requirements:

1. The occupiable floor area is a least 70 square feet,

2. The occupiable floor area has a ceiling height in accordance with Section R305,

3. The occupiable space is enclosed by the roof assembly above, knee walls (if applicable) on the sides, and the floor-ceiling assembly below.

2009 Code: Definitions, Attic and Habitable Attic

Page 74: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

74

• 2009 Code: Labeled. Equipment, materials or products to label, seal, symbol or other identifying mark of a nationally recognized testing laboratory.

2009 Code: Definitions, Labeled and Listed

Page 75: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

75

2009 Code: Definitions, Structural Insulated Panel (SIP)

A structural sandwich panel that consists of a light-weight foam plastic core securely laminated between two thin, rigid wood structural panel facings.

Page 76: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

76

R301.1.1 Alternative Provisions

As an alternative to the requirements in Section R301.1 the following standards are permitted.

1. American Forest and Paper Association (AF&PA) Wood Frame Construction Manual (WFCM).

2. American Iron and Steel Institute (AISI) Standard for Cold Formed Steel Framing-Prescriptive Method for One- and Two-Family Dwellings, (updated standard, and applies to 3 stories).

3. ICC-400 Standard on the Design and Construction of Log Structures.

Page 77: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

77

Table 301.2(5) Snow Loads

BAY 35 All except:

40 CITY OF PINCONNING

TOWNSHIP OF FRASER

TOWNSHIP OF GARFIELD

TOWNSHIP OF GIBSON

TOWNSHIP OF MT. FOREST

TOWNSHIP OF PINCONNING

BENZIE 60 All

BERRIEN 50 All

Page 78: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

78

Table R301.5 Minimum Uniformly Distributed Live Loads

The definitions for deck and balcony have been revised, and the minimum live load for balconies has been lowered from 60 psf to 40 psf to be consistent with decks.

Page 79: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

79

Table R301.5 Minimum Uniformly Distributed Live Loads (con’t)

Page 80: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

80

Exterior Walls. Construction, projections, openings and penetrations of exterior walls of dwellings and accessory buildings shall comply with Table R302.1

Exceptions:1. Walls, projections, openings, or penetrations in walls perpendicular to the line used to determine the fire separation.2. Walls of dwellings and accessory structures located on the same lot.

Section R302 Fire-resistant Construction

Page 81: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

81

R302.1 thru R302.3 Dwelling Unit Separation

Separate building in accordance with R302.1 for exterior walls.

Townhouses; A common two hour fire-resistance rated wall is required. State Amendment

Page 82: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

82

R302.5 Garage Openings and Penetrations

• R302.5 Dwelling/Garage Opening/Penetration Protection. Openings and penetrations through the walls or ceilings separating the dwelling from the garage shall be in accordance with Sections R302.5.1 through R302.5.3

• R302.5.1 Opening Protections.• R302.5.2 Duct Penetration

• R302.5.3 Other Penetrations. Penetrations through the separation required in Section R302.6 shall be protected as required by Section R302.11, Item 4.

Page 83: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

83

R302.6 Dwelling/Garage Fire Separation

The garage shall be separated as required by Table R302.6. Openings in garage walls shall comply with Section R302.5. This provision does not apply to garage walls that are perpendicular to the adjacent dwelling unit wall.

Page 84: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

84

R305.1 Minimum Ceiling Height

• R305.1 Minimum Height. Habitable space, hallways, bathrooms, toilet rooms, laundry rooms and portions of basements containing these spaces shall have a ceiling height of not less than 7 feet.Exceptions: 1. For rooms with sloped ceilings, at least 50 percent of the required floor area of the room must have a ceiling height of at least 7 feet (2134 mm) and no portion of the required floor area may have a ceiling height of less than 5 feet (1524 mm).

2. Bathrooms shall have a minimum ceiling height of 6 feet 8 inches (2036 mm) at the center of the front clearance area for fixtures as shown in Figure R307.1. The ceiling height above fixtures shall be such that the fixture is capable of being used for its intended purpose. A shower or tub equipped with a showerhead shall have a minimum ceiling height of 6 feet 8 inches (2036 mm) above a minimum area 30 inches (762 mm) by 30 inches (762 mm) at the showerhead.

Page 85: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

85

R305.1 Minimum Ceiling Height (con’t)

Page 86: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

86

R305.1.1 Basements

• Portions of basements that do not contain habitable space, hallways, bathrooms, toilet rooms, and laundry rooms shall have a ceiling height of not less than 6 feet 8 inches (2032 mm).Exception: Beams, girders, ducts, or other obstructions may project to within 6 feet, 4 inches (1931 mm) of the finished floor.

• R306.1 Sanitary facilities. Every dwelling unit shall be provided with a water closet, lavatory, bathtub or shower, and automatic clothes washer connection.

Page 87: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

87

• R308.1.1 Identification of Multiple Assemblies. “CPSC 16 CFR 1201” or “ANSI Z97.1” as appropriate.

• R308.3 Human Impact Loads. Exceptions:2. Mirrors and other glass panels mounted or hung on a surface that provides a continuous backing support.3. Glass unit masonry complying with Section R610.

R308.1.1 & R308.3 Identification of Glazing and Human Impact Loads

Page 88: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

88

R308.1.1 & R308.3 Identification of Glazing and Human Impact Loads (con’t)

Page 89: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

89

R308.4 Hazardous Locations

The following shall be considered specific hazardous locations for the purpose of glazing:

1. Glazing in all fixed and operable panels of swinging, sliding, and bifold doors.

Exceptions:

1. Glazed openings of a size through which a 3-inch diameter sphere is unable to pass.

2. Decorative glazing.

6. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical edge is within a 24-inch arc of the door in a closed position and whose bottom edge is less than 60 inches above the floor or walking surface.

Page 90: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

90

R308.1.1 & R308.3 Identification of Glazing and Human Impact Loads (con’t)

Page 91: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

91

R310.1 Emergency Escape and Rescue Required

Basements, habitable attics and every sleeping room shall have at least one operable emergency escape and rescue opening.

Page 92: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

92

R311.1 Means of Egress

• R311.1 Means of Egress. All dwellings shall be provided with a means of egress as provided in this section. The means of egress shall provide a continuous and unobstructed path of vertical and horizontal egress travel from all portions of the dwelling to the exterior of the dwelling at the required egress door without requiring travel through a garage.

• R311.2 Egress Door. At least one egress door shall be provided for each dwelling unit. The egress door shall be side-hinged and shall provide a minimum clear width of 32 inches when measured between the face of the door and the stop, with the door open 90 degrees (1.57 rad). The minimum clear height of the door opening shall not be less than 78 inches in height measured from the top of the threshold to the bottom of the stop. Other doors shall not be required to comply with these minimum dimensions.

Page 93: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

93

R311 Means of Egress

Page 94: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

94

R311.7.2 Headroom

The minimum headroom in all parts of the stairway shall not be less than 6 feet 8 inches measured vertically from the sloped line adjoining the tread nosing or from the floor surface of the landing or platform on the portion of the stairway.

Exception: Where the nosings of treads at the side of a flight extend under the edge of a floor opening through which the stair passes, the floor opening shall be allowed to project horizontally into the required headroom a maximum of 4 ¾ inches.

Page 95: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

95

R311.7.3 & R311.7.4 Stair Treads and Risers

New provisions defining walk line intend to clarify the tread depth requirement for winders. Measurement of stair treads and risers exclusive of carpet will result in more consistent application of the code. A new exception to uniform tread depth provides that winders are permitted for a turn in a stairway of otherwise rectangular treads.• R3111.7.3 Walk line.• R311.7.4 Stair Treads and Risers.• R311.7.4.1 Riser Height• R311.7.4.2 Tread Depth.

Page 96: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

96

R311.7.3 & R311.7.4 Stair Treads and Risers (con’t)

Page 97: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

97

R311.7.7 Handrails

Exceptions:

1. The use of a volute, turnout, or starting easing shall be allowed over the lowest tread.

2. When handrail fittings or bendings are used to provide continuous transition between flights, handrail height shall be permitted to exceed the maximum height.

Page 98: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

98

• R312.1 Where required. Guards shall be located along open-sided walking surfaces, including stairs, ramps and landings, that are located more than 30 inches measured vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side. Insect screening shall not be considered as a guard.

• R312.2 Height. Required guards at open-sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than 36 inches… adjacent fixed seating….

Exceptions:

1. Guards on the open sides of stairs shall have a height not less than 34 inches.

2. Where the top of the guard also serves as a handrail shall not be not less than 34 inches and not more than 38 inches.

• R312.3 Opening Limitations.

R312 Guards

Page 99: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

99

R312.1 Guards (con’t)

Page 100: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

100

• R313.1 Design and installation. Where installed, automatic residential fire sprinkler systems shall conform to the design and installation requirements of the National Fire Protection Association (NFPA) standard 13D.

• P2902.5.4 Connections to automatic fire sprinkler systems. The potable water supply to automatic fire sprinkler systems shall be protected against backflow by a double check valve assembly or a reduced pressure principle backflow preventer.Exception: Isolation of the water distribution system is not required for deluge, preaction, or dry pipe system.

• R2904.1 General Where installed, residential fire sprinkler systems, or portions thereof, shall be in accordance with NFPA 13D.

R 408.30539a Automatic Fire Sprinkler Systems-MRC- Not Required

Page 101: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

101

• R314.1 Smoke Detection and Notification.• R314.2 Smoke Detection Systems. Where a household fire

warning system is installed using a combination of smoke detector and audible notification device(s), it shall become a permanent fixture of the occupancy and owned by the homeowner. The system shall be monitored by an approved supervising station and be maintained in accordance with NFPA 72.

Exception: Where smoke alarms are provided meeting the requirements of Section R314.4.

• R314.3 Location. Smoke alarms shall be installed in the following locations:1. In each sleeping room.2. Outside each separate sleeping area of the bedrooms.3. On each additional story of the dwelling, including basements and habitable attics.

R314 Smoke Alarms

Page 102: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

102

R314 Smoke Alarms (con’t)

• R314.3.1 Alterations, Repairs and Additions requiring a permit occur, or when one or more sleeping rooms are added or created in existing dwellings, the individual dwelling unit shall be equipped with smoke alarms located as required for new dwellings.Exceptions:1. Work involving the exterior surfaces of dwellings, such as the replacement of roofing or siding, or the addition or replacement of windows or doors, or the addition of a porch or deck, are exempt from the requirements of this section.2. Installation, alteration or repairs of plumbing or mechanical systems are exempt from the requirements of this section.

Page 103: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

103

R314 Smoke Alarms (con’t)

• R314.4 Power Source. Smoke alarms shall receive their primary power from the building wiring when such wiring is served from a commercial source, and when primary power is interrupted, shall receive power from a battery. Wiring shall be permanent and without a disconnecting switch other than those required for overcurrent protection. Smoke alarms shall be interconnected.

Exceptions:

1. Smoke alarms shall be permitted to be battery operated when installed in buildings without commercial power.

2. Interconnection and hard-wiring of smoke alarms in existing areas shall not be required where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space or basement available

which could provide access for hard-wiring and interconnection without the removal of interior finishes.

Page 104: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

104

R315 Carbon Monoxide Alarms

• R315.1 Carbon Monoxide Alarms. For new construction, an approved carbon monoxide alarm shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms in dwelling units within which fuel-fired appliances are installed and in dwelling units that have attached garages.

• R315.2 Where Required in Existing Dwellings. Where work requiring a permit occurs in existing dwellings that have attached garages or in existing dwellings within which fuel-fired appliances exist, carbon monoxide alarms shall be provided in accordance with Section R315.1.

• R315.3 Alarm Requirements. Single station carbon monoxide alarms shall be listed as complying with UL 2034 and shall be in stalled in accordance with this code and the manufacturer’s installation instructions.

Page 105: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

105

R317.1 Locations for Protection Against Decay

Protection from decay is now required for wood siding, sheathing, and wall framing less than 2 inches above a concrete slab exposed to weather.

• R317 Protection of Wood and Wood Based Products Against Decay.

• R317.1 Location Required. Protection of wood and wood based products from decay shall be provided in the following locations.5. Wood siding, sheathing and wall framing on the exterior of a building having a clearance of less than 6” from the ground or less than 2 inches measured vertically from concrete steps, porch slabs, patio slabs, and similar horizontal surfaces exposed to the weather.

Page 106: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

106

R317.1 Locations for Protection Against Decay (con’t)

Page 107: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

107

R317.3 Fasteners and Connectors in Contact with Treated Wood

• R317.3 Fasteners and Connectors in Contact with Preservative-treated and Fire-retardant-treated Wood.

• R317.3.1 Fasteners for Preservative-treated Wood.• R317.3.2 Fastenings for Wood Foundations.• R317.3.3 Fasteners for Fire-retardant-treated Wood

used in Exterior Applications or Wet or Damp Locations.

• R317.3.4 Fasteners for Fire-retardant-treated Wood used in Interior Applications.

• All fasteners shall be of the appropriate ASTM standard

Page 108: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

108

A definition and specific requirements for manufactured wood/plastic composites are introduced into the IRC.

• R317.4 Wood/Plastic Composites.

• R317.4.1 Wood/plastic composites shall be installed in accordance with the manufacturer’s instructions.

R317.4 Wood/Plastic Composites

Page 109: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

109

R202 Definitions-Wood/Plastic Composite

A composite material made primarily from wood or cellulose-based materials and plastic.

Page 110: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

110

R317.4 Wood/Plastic Composites (con’t)

• R311.7.4.4 Exterior Wood/plastic Composite Stair Treads. Wood/plastic composite stair treads shall comply with the provisions of Section R317.4.

• R311.7.7.4 Exterior Wood/plastic Composite Handrails. Wood/plastic composite handrails shall comply with the provisions of Section R317.4.

• R317.4=ASTM D7032

Page 111: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

111

R319.1 Site Address

The IRC now prescribes the minimum size of address numbers and requires a contrasting background for visibility.

• R319.1 Address Numbers. Numbers shall be a minimum of 4 inches high with a minimum stroke width of ½ inch.

Page 112: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

112

R323 Storm Shelters

Storm shelters, when built or installed, must be constructed in accordance with the new ICC/NSSA-500 “Standards on the Design and Construction of Storm Shelters.”

Page 113: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

113

R401.3 Surface Drainage

Where it is not feasible to provide the prescribed fall of 6 inches within the first 10 feet away from a foundation, the code includes new performance language requiring drainage away from the foundation without prescribing a slope.

• R401.3 Drainage.Exception: Where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, drains or swales shall be constructed to ensure drainage away from the structure.

Page 114: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

114

R401.4 Soil Tests

The revised text defines the necessary criteria for requiring a soil test in more objective terms based on available scientific data.

• R401.4 Soil Tests. Where quantifiable data created by accepted soil science methodologies indicate expansive, compressible, shifting or other questionable soil characteristics are likely to be present.

Page 115: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

115

R403.4 Footings for Precast Concrete Foundations

Page 116: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

116

R404.1 Concrete and Masonry Foundation Walls

The concrete foundation wall provisions have been substantially revised and are now separated from the masonry foundation wall provisions. There are no technical changes to the masonry provisions, there are a number of changes to the concrete provisions.

Page 117: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

117

R404.5 Precast Concrete Foundation Walls

• R404.5.1 Design. Precast concrete foundation walls shall be designed in accordance with accepted engineering practice. The design and manufacture of precast concrete foundation wall panels shall comply with the materials requirements of Section R402.3 or ACI 318.

• R404.5.2 Precast Concrete Foundation Design Drawings.1. Design loading as applicable2. Footing design and material3. Concentrated loads and their points of application4. Soil-bearing capacity5. Maximum allowable total uniform load6. Seismic Design Category7. Basic wind speed

Page 118: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

118

R405.1.1 Precast Concrete Foundation

Precast concrete walls that retain earth and enclose habitable or useable space located below grade that rest on crushed stone footings shall have a perforated drainage pipe installed below the base of the wall on either the interior or exterior side of the wall, at least one foot beyond the edge of the wall.

Page 119: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

119

R406.4 Precast Concrete Foundation System Dampproofing

• R406.4 Precast Concrete Foundation System Dampproofing. Except where required by Section R406.2 to be waterproofed shall be damproofed.

• R406.4.1 Panel Joints Sealed. Precast concrete foundation panel joints shall be sealed.

Page 120: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

120

R408.1 & R408.2 Underfloor Space Ventilation

This change reestablishes a provision found in the 2003 IRC for reducing the required net area of ventilation openings to 1/1500 of the underfloor area where the ground is covered with a vapor retarder.

• R408.1 Ventilation.• R408.2 Openings for Underfloor Ventilation.

Exception: The total area of ventilation openings shall be permitted to be reduced to 1/500.

The 2006 IRC deleted a provision for reduced ventilation of crawl spaces where a vapor retarder covered the ground of the crawl space. This exception from the 2003 IRC is reinstated in the 2009 edition.

Page 121: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

121

R408.1 & R408.2 Underfloor Space Ventilation (con’t)

Page 122: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

122

R502.2.2.1 & Table R502.2.2.1 Deck Ledger Connection

• R502.2.2.1 Deck Ledger Connection to Band Joist.• R502.2.2.1.1 Placement of Lag Screws or Bolts in

Deck Ledgers.• R502.2.2.2 Alternate Deck Ledger Connection.• R502.2.2.3 Deck Lateral Load Connection.

Page 123: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

123

R502.2.2.1 & Table R502.2.2.1 Deck Ledger Connection (con’t)

Page 124: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

124

R502.7 Lateral Restraint for Wood Joists

• R502.7 Lateral Restraint at Supports.Exceptions:1. Trusses, structural composite lumber, structural glued-laminated members and I-joists shall be supported laterally as required by the manufacturer’s recommendations.

Page 125: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

125

R602.6.1 Drilling and Notching of Top Plate

To reduce the possibility of splitting the wood plate, the length of the nails used to attach the metal tie has been reduced from 3 ½ inches to 1 ½ inches.

• R602.6.1 Drilling and Notching of Top Plate. Shall be fastened across and to the plate at each side of the opening with not less than eight 10d (0.148 inch diameter) nails having a minimum length of 1 ½ inches. The metal tie must extend a minimum of 6 inches past the opening.

Page 126: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

126

R602.6.1 Drilling and Notching of Top Plate (con’t)

Page 127: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

127

R611 Exterior Concrete Walls Construction

Section R611 has been completely revised to reflect the provisions of the new referenced Portland Cement Association standard PCA 100 “Prescriptive Design of Exterior Concrete Walls for One- and Two-Family Dwellings”.

• R611 Exterior Concrete Wall Construction• R611.1 General. Exterior Concrete walls shall be

designed and constructed in accordance with the provisions of this section or in accordance with the provisions of PCA 100 or ACI 318.

Page 128: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

128

R612.2 Window Sills

• R612.2 Window Sills. In dwelling units, where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor. Operable sections of windows shall not permit openings that allow passage of a 4-inch-diameter sphere where such openings are located within 24 inches of the finished floor.

• R612.3 Window Fall Prevention Devices.• R612.4 Window Opening Limiting Devices.• R612.4.1 General Requirements.• R612.4.2 Operation for Emergency Escape.

Page 129: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

129

R612.2 Window Sills (con’t)

Page 130: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

130

R703 Weather-Resistant Exterior Covering

Performance requirements for wind resistance have been added to the water resistance provisions of exterior wall covering systems in Section R703.1. Changes to Table R703.4 clarify the water-resistive barrier requirements.

Page 131: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

131

R703.7.3 Lintels

• R703.7.3 Lintels. Steel lintels shall be shop coated with a rust inhibitive paint, except for lintels made of corrosion-resistant steel or steel treated with coatings to provide corrosion resistance. Construction of openings shall comply with either Section R703.7.3.1 or 703.7.3.2.

Page 132: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

132

R703.7.4 Masonry Veneer Anchorage

• R703.7.4 Anchorage. Masonry veneer shall be anchored to the supporting wall with corrosion-resistant metal ties embedded in mortar or grout and extending into the veneer a minimum of 1 ½ in., with not less than 5/8 inch mortar or grout cover to outside face.

Page 133: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

133

R806 Attic Ventilation

The attic ventilation requirements now permit methods and materials other than wire mesh for protecting openings against the entry of insects. The minimum opening dimension has been reduced from 1/8 to 1/16 inch. Vapor retarders are broken into three classed based on properties associated with the rate of restricting the passage of water. The provisions for unvented attic spaces have been rewritten for accuracy and clarification.

Page 134: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

134

R806 Attic Ventilation (con’t)

Page 135: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

135

R807.1 Attic Access

• R807.1 Attic Access. Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that exceed 30 square feet and have a vertical height of 30 inches or greater. The vertical height shall be measured from the top of the ceiling framing members to the underside of the roof framing members.

The rough-framed opening shall not be less than 22 inches by 30 inches. When located in a wall, the opening shall be a minimum of 22 inches wide by 30 inches high. When the access is located in a ceiling, minimum unobstructed headroom in the attic space shall be 30 inches at some point above the access measured vertically from the bottom of ceiling framing members. See Section M1305.1.3 for access requirements where mechanical equipment is located in attics.

Page 136: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

136

R807.1 Attic Access (con’t)

Page 137: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

137

R1001.8 Smoke Chamber

Smoke chamber walls shall be constructed of solid masonry units, hollow masonry units grouted solid, stone or concrete. The total minimum thickness of front, back, and side walls shall be 8 inches of solid masonry. The inside surface shall be parged smooth with refractory mortar conforming to ASTM C 199.

Page 138: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

138

Energy Conservation

• Adopts by Reference 2009 IECC with Michigan Amendments

• Scoping includes MRC scoping

• Separate Michigan Code Book for Energy Conservation

• Adoption date March 9, 2011

Page 139: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

139

AG105.2 Outdoor Swimming Pool Barrier

For doors that provide access to an outdoor swimming pool, the prescriptive requirements for door alarm activation, deactivation, and reset have been deleted in favor of matching requirements in UL 2017.

• AG105.2 Outdoor Swimming Pool.

Page 140: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

140

Special Thanks to:

• Tracie Pack

• Shannon Matsumoto

Page 141: 2009 RESIDENTIAL CODE COMPLETE UPDATE 4 HOURS TECHNICAL ALL CLASSIFICATIONS COURSE NUMBER 16077

141

END

THANK YOU

Bureau of Construction Codes

(517) 241-9302

www.michigan.gov/bcc