New rangesSystem proM compact® and Compact Home
ABB BA ATAP – BU 3118Enclosures & DIN-rail Products
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
2
To improve and modernize the well proven proM range, a new range,
proM compact has been introduced end of last year in some selected markets.
We are now introducing this range into all our markets - step by step, together with the economic
Compact Home
range, in markets where this is useful
New MCB and RCD product ranges
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
3
To differentiate between economical ranges for domestic /
residential installations and
high performance ranges for commercial / industrial applications
and to offer the customers the best possiblesolution, 2 distinctive different, but yetsimilar and combinable ranges, have beencreated System proM compact, the modular
installation system for all applications, but specifically for high performance demand in industries
Compact Home with limited features for easy and simple use in building installation
The right range for any application
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
4
System proM compact
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
5
The new complete range at a glance:
Miniature circuit breakers (MCB's) Residual current devices (RCD's) Surge protection devices MDRC's
Protection devices Command devices Load management devices Measuring devices Other devices
Busbars and accessories
System proM compact range
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
6
A PLUSin all areas of application
System proM compact, the modularinstallation system for DIN rails
Launched successfully and greetedenthusiastically by experts and users
A full range is now available, coveringall applications for electrical building installation
System proM compact is the logical next step of development after System proM
System pro M compact range
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
7
Better access Due to the new design:
Upper and lower shoulders reduced 50% more working space between the rows Outgoing and incoming connection points are
easily accessible Comfortable, precise installation of devices,
even where only very limited space in the consumer unit is available
MCB's and RCD's have an optimized design, providing for an even safer connection technology
System proM compact range: plus
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
8
A clear view, instead of feeling the way
Now rear-mounted busbars Wire connection point in front Result:
an unobstructed view on all connection points never fumble for the right connection point
again improved safety tangible time-savings
System proM compact range: plus
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
9
No possibility of mistakes New ABB terminal technology:
Bi-directional cylinder-lift terminals,foolproof and failsafe
Inaccurate - or even incorrect – fixing of wiresor cross wiring is impossible, due to the new design of the terminal
This also excludes the risk of a subsequent electrical accident, e.g. risk of fire caused by creepage current.
System proM compact range: plus
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
10
Easier to replace DIN-rail mounting system makes it easy to replace
devices (MCB's, RCD's) from the assembly No time-consuming extra work:
Busbar remains with the assembly.To remove the device, just loosen the screw, lift the device and pull it out.
If necessary, all devices of the series connected to the new proM compact busbars may be exchanged easily and quickly, e.g. to implement the adaptation to the standard VDE 0100, part 410
System proM compact range: plus
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
11
Individual, efficient labeling of devices
From now on, you will be able to use the self-adhesive labels that can be applied directly on the devices.
For a transitory period, you may just as well use for some devices the self-adhesive system in combination with the still commonly used plug-on technique.
System proM compact range: plus
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
12
New product line name The new type code system indicates the category
to which a device is allocated This facilitates your product selection
System proM compact range: plus
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
13
Outstanding, uniform design From MCB's and RCCB's to modular installation
devices, all components of the system are distinguished by a clear, functional appearance
Homogenous design that makes the technology's perfection and the precision with which the electrician made the installation visible also for the customer
System proM compact range: plus
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
14
Protection Devices MCB's (Miniature circuit breakers) RCCB's
(Residual current circuit breakers) Main RCCB’s RCBO's
(Residual current operatedcircuit breakers with overcurrent release)
RCD-blocks (Residual-current unit to be fitted on MCB's)
System proM compact range
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
15
Type code system for the new MCB's
S 200 L„L“ stands for 4,5 kA rupturing capacity
S 2006 kA rupturing capacity
S 200 M„M“ stands for 10 kA rupturing capacity
S200 P„P“ stands for up to 25 kA rupturing capacity
New ABB MCB range
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
16
Type code system for new proM compact MCB's
N° of poles: 1 - 1+N - 2 - 3 - 3+N - 4
Family: S200 = MCB's
S202 M C10
Rated currents: 0.2…63A
Tripping characteristics: B, C, D, K, Z
Breaking cap.: 4,5 - 6 - 10 up to 25 kA
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
17
Compatibility old series vs. new series
Overlapping and mixing of old and new series is possible without problems, thanks to:
Same terminal height on DIN-rail of old and new series for both MCB's and RCD's on the bottom side
Same profile and same dimensions – same frontal looks
New MCB Old MCB New RCCB/RCBO
busbar
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
18
New RCD's: 3 families
DDA
T
RCCB’s RCBO’s Blocks
Earth leakage Indirect contact
Overload Short circuit Earth leakage Indirect contact
(with MCB’s) Overload Short circuit Earth leakage Indirect contact
Provides protection against:
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
19
ABB SACE
ABB STOTZ
Actual ABB RCD offer
F274 / F284
F362 / F372 / F392
F364 / F374 / F394
F272 / F282
DDA
F362 / F372 / F392
F364 / F374 / F394
DS652 / DS672
DS654 / DS674
DS951 / DS651
F271
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
20
RCCB’s F 200 AC / F 200 A
RCCBs type AC/A (ex F360/F370)
RCBO's DS 200 AC / DS 200 A
RCBO's type AC/A 6kA (ex DS650/DS750) DS 200 M AC / DS 200 M A
RCBO's type AC/A 10kA (ex DS670/F270)
RCD-blocks DDA 200 AC / DDA 200 A
RCD blocks type AC/A (ex DDA60/DDA70)
New ABB RCD’s – one common range
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
21
F204 A S - 63/0,03
N° of poles: 2 - 4
Family: F200 = RCCB's
Types: AC - A
Tripping time: S for selective
Current: 16 - 25 – 40 – 63 – 80 – 100 A
Sensitivity: 10 - 30 - 100 - 300 - 500 mA
New proM compact RCCB's type code system
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
22
N° of poles: 1+N - 2 - 3 - 4
Family: DS200 = RCBO's
DS202 L A S - C10/0,03
Types: AC - A
Tripping time: S for selective
Rated currents: 6A…63A
Sensitivity: 10 - 30 - 100 - 300 - 500 mA
Tripping characteristics: B - C - D - K - ZBreaking cap.: 4,5 - 6 -10 - 25 kA
New proM compact RCBO's type code system
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
23
N° of poles: 2 - 3 - 4
Family: DDA200 = RCD blocks
DDA202 A S - 25/0,03
Type: AC - A
Tripping time: S for selective
Current: 25 - 40 - 63 A
Sensitivity: 30 – 100 – 300 – 500 mA
New proM compact RCD block type codes
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
24
Actual F3
Im = 1500 A
Inc= 6000 A with 63 A gLfuse SCPD
RCCB's: improved short circuit performance -Short circuit performances combination
Im = short-circuit breaking capacity
Inc= conditional short-circuit breaking capacity
New F200
Im = 1000 A
Inc= 10000 A with 100A gLfuse SCPD
600063
10000100
RCCB's: improved performance…
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
25
The Product Range Accessories
Universal signal / auxiliary contact Retrofittable to the right hand side of MCB's
and RCCB's Can be switched with a setscrew to either
function "signal contact“ or "auxiliary contact"
Up to 3 units could be mounted to1 base device
Busbar facility Separate positions for outgoing / incoming
terminals. Terminals can be re-tightened Test and reset functions No parts can be lost
MCB's: auxiliary element innovation
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
26
Accessories
Auxiliary switch S2C-H 6R only as add-on to circuit-breaker without test function
Shunt trip:2 models for different voltage levels
Undervoltage trip:6 models for different voltage levels
MCB's: auxiliary elements
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
27
Same auxiliary devices for MCB's and RCD’s
DDA200 blocks are fitted on the left side of S200 MCB's, by that allowing a complete accessoriability for the MCB – the same auxiliary devices can now also be fitted to RCCB’s
MCB’s 1 to 4PRCCB’s 2P or 4P
ST + H + H
UR + H + H
S/H + H + H
MOD
RCD-block 2P, 3P or 4P
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
28
RCCB 2P or 4P H RCCB 2P or 4P
ST + H + H
UR + H + H
S/H + H + H
H = Auxiliary contactS/H = Auxiliary/signal contactUR = Undervoltage releaseST = Shunt tripAR = Automatic resclosing unit
Actual F3 New F200
AR
RCCB's: auxiliary elements
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
29
RCD-blocks: an auxiliary release for MCB's
DDA200 blocks will be fitted on the left side of the S200 MCB's, by that allowing a complete accessoriability for the MCB
MCB 2P, 3P or 4P
ST + H + H
UR + H + H
S/H + H + H
MOD
RCD-block 2P, 3P or 4P
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
30
RCD-blocks: easier installation
...assure an easy wiring of MCB's fitted with RCD-blocks with standard busbars
…allow the possibility to fit MCB's fitted with RCD-blocks on the ways of Type B distribution boards
Housing with holes in the upper side…
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
31
Surge protection devices class B arrester class C arrester class D arrester
System proM compact range
MDRC's: protection devices Residual current relays Toroidal transformer for RCD’s Fuse holders Fuse switches
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
32
MDRC's: command devices Universal signal / auxiliary contact Auxiliary contact for MCB's Shunt trips Undervoltage trips Installation contactors Alarm indicators Pushbuttons, switches, indicator lights Isolators Remote switches Latching relays Latching relays electronic Installation relays
System proM compact range
New isolator range E200,similar range as E 270 / E 240
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
33
MDRC's: load management devices Time-delay relays (TDR) Time switches Timers Staircase timers Dimmers / high-performance dimmers Light level switches Twilight switches Electronic potentiometers
System proM compact range
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
34
MDRC's: measuring devices Elapsed time meters Energy consumption meters Analog and digital ammeters and
voltmeters
System proM compact range
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
35
MDRC's: Other devices Bells Bell transformers Emergency lights for consumer units Undervoltage monitoring relays Mains disconnection relays Socket-outlet (SCHUKO® /UNEL type)
Various accessories Special busbars Self-adhesive labeling system
System proM compact range
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
36
Compact Home
The perfect supplement to cover all
requirements
Compact Home the simple range for basic requirements which can be combined with the proM compact range
Compact home with a basic range of products: MCB’s and RCCB’s and limited features for easy and simple use in building installation
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
37
Compact Home…
…only one range all over the world, identified by the black toggle for both RCCB’s and MCB's
…compatible both with old System pro M series and new System pro M compact series
…mainly for residential and commercial applications
…all required functions are available
…in order to cover all market’s requirements: Compact Home range dedicated to low-end market, standard range for tertiary and industrial applications
… in addition to the standard range…
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
38
RCCB FH 200
MCB SH 200
A range dedicated to buildings applications, for both residential and commercial
Compact Home range offers the two essential types of protection for building applications: one against overcurrent and short-circuit
with the SH 200 and one against earth-leakage with the
FH 200 Compatibility with System proM compact
and System proM range permits to complete the Compact Home range with many other functions from the proM compact range
Compact Home
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
39
SH 200 range Compact Home offers a wide range of MCB's, suitable
for all applications and installation habits in buildings Available in:
Amp ratings: 6 - 40 A
Tripping characteristics: B and C
Poles: 1-, 2-, 3-, 4-pole, 1 + NA and 3 + NA
Breaking capacities: 3 kA, 4.5 kA and 6 kA
Compact Home
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
40
SH 201 L – C 8
SH 200 designation
Family S = MCB
H = Compact Home range
Number of poles (1-2-3)
Breakingcapacity in kA: 3 - T 4,5 - L 6 - no suffix Tripping characteristic (B, C)
Rating in A (6…40 A)
Compact Home
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
41
SH 200’s main technical features are marked in front of product:
Marking with a clear indication of family, number of poles, breaking capacity, tripping characteristic, rated current and rated voltage
Wiring diagram to prevent from a wrong connection
SH 200 is available in 3 different versions:3 - 4.5 - 6 kA to suit the individual market requirements.
SH 200 complies to IEC/EN 60898 and carries all the relevant approval marks for the foreseen markets
Compact Home
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
42
SH 200 terminals SH 200 shows a 25 mm2 cage terminal suitable for busbar and cable
connection The terminal position offers full compatibility to other Compact Home
components, all standard components of System proM compact as well as System proM.
Compact Home
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
43
FH 200 range Compact Home offers a wide range of RCCB's, suitable for
all applications and installation habits in buildings
Available in:
Sizes: 25, 40 and 63 A
Sensitivity thresholds: 0.03, 0.1 and 0.3 A
Poles: 2 and 4 poles
Types/classes: AC and A
Compact Home
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
44
FH 202 AC - 25/0.03
Family F = RCCB
H = Compact Home range
Number of poles(2 & 4)
Type
Current 25, 40 or 63 A
Sensitivity threshold 0.03, 0.1 or 0.3
SH 200 designation
Compact Home
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
45
Black toggle (the same colour of SH 200’s one)
Yellow snap on device
Test button – which must be tested monthly – with “TEST” indication in English in order to be international
FH 200 is easy recognizable, thanks to:
Laser-printed home in front of product
Compact Home
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
46
FH 200’s main technical features are marked in front of product:
Wiring diagram to prevent from a wrong connection
Part number in order to allow a quick identification of the device
FH 200 reaches a Inc value of 6000A in coordination with a fuse of 63A; Im=Im=1000A
Marking with a clear indication of family, range, number of poles, type, rated current, sensitivity threshold and rated voltage (see also slide 8)
Compact Home
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
47
FH 200 terminals FH 200 has the same terminals as the proM compact (failsafe bi-
directional cylinder lift terminals The front slot of the terminal can be wired with cables up to 25 mm2,
while the back one is suitable for wiring with busbars or cables up to 10 mm2.
Compact Home
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
48
More information about the FH 200 FH 200 complies to IEC/EN 61008 and the range
has all the international marks and approvals of the countries in which it will be offered
FH 200 devices are also conforming to the EU standards 2002/95/CE regarding the restriction of dangerous substances used in electrical equipment. On the back of the product the corresponding symbol is shown and it means that the RCCB must be disposed off separately from general litter
Installation instructions are laser-printed on the side of the product
Compact Home
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
49
Name of the range clearly indicates also in the commercial designation H means “Home range”
On the RCCB, a little home will be marked in the front, too
Black switching toggle for both FH 200 and SH 200
Wiring diagrams marked in front of both SH 200 and FH 200 (in all pole versions), same as for MCB's and RCCB’s of the standard range
Compact Home range vs proM compact range
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
50
Compact Home range cannot be coupled
with auxiliary devices
versus
System proM compact range can be coupled with a wide range of
auxiliary devices
Compact Home range vs proM compact range
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
51
S 200 has got a black plastic fixing device with 3 positions, which allows the withdrawal without any tools in presence
of a busbar
versus
Metal fixing device with standard functionality only for SH 200
(withdrawal of the MCB without tools in presence of a busbar is not
possible)
SH 200 versus S 200
Possibility to withdraw S 200 in presence of a busbar without tools as indicated in the instruction sheet
S 200SH 200
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
52
SH 200 has 25 mm2 wide cage terminals and can
be wired with FH 200 with compact
busbars both from upper and lower side
versus
S 200 shows failsafe bidirectional cylinder-lift
terminals which permits a faster and safer connection
SH 200 versus S 200
Busbar connection between MCB‘s of the ranges proM, proM compact and Compact Home possible
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
53
No contact position indication (CPI) for
RCCB FH 200
versus
Presence of CPI to signal position of RCCB
F 200’s contact
Black switching toggle
versus
Blue switching toggle
FH 200 versus F 200
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
54
Yellow snap on device with only 2 positions
for RCCB FH 200
versus
Black snap on device with 3 positions for
RCCB F 200 (withdrawal without tools in presence
of busbar is possible)
FH 200 versus F 200
Possibility to withdraw FH 200 only in absence of a busbar, is also indicated on the side of the product
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
55
“TEST” marked on the side of the test button for FH 200, same as for standard F 200 (English marking is considered international)
In front of the FH 200 a Inc value of 6000 A, reached in coordination with a
63A fuse (and this is sufficient for residential applications), is marked
versus
F 200’s level of coordination is higher: Inc = 10000 A with a 100A back up fuse
FH 200 versus F 200
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
56
Compatibility old series vs. new series
Overlapping and mixing of old and new series up to 63 A is possible without problems, thanks to:
Same terminal height from DIN-rail of all series, for both MCB's and RCD's on the bottom side
Same profile and same dimensions – same frontal looks
proM compact MCB RCCB
busbar
Compact Home MCB RCCB
proM MCB RCCB
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
57
Availability of the new series
proM proM compactCompact Home
Availability proM proM compactCompact Home
Availability
S 230 SH 200 T 3 kA available F 360 F 200 AC availableS 240 SH 200 L 4,5 kA available F 370 F 200 A availableS 190 SH 200 6 kA available not available FH 200 AC availableS 240 EC S 200 L 4,5 kA available not available FH 200 A availableS 250 / S 260 S 200 6 kA available F 660-80/100 A F 200 AC-80/100 A June 2005S 270 S 200 M 10 kA available F 670-80/100 A F 200 A-80/100 A June 2005S 280 S 200 P 25 kA available P/F 270 FS 200 availableAccessories Access.compact available D 270 D 200 to be definedS 280 - 80/100 A S 200 to be defined DDA (RCD block) DDA 200 availableS 280 UC S 200 P-UC to be defined E 270 up to 125 A E 200 i availableS 290 no solution will be kept Busbars Busbars compact available
products used to form / complete the range
© A
BB
SA
CE
LP
D +
AB
B S
TO
TZ
-KO
NT
AK
T G
mbH
, 05
-200
4
58