SUbMittaL Data: pLa-a24ba & pUY-a24nHa 24,000 btU/H ... · Air intake grille Air outlet hole Air...

Post on 20-Oct-2020

0 views 0 download

Transcript of SUbMittaL Data: pLa-a24ba & pUY-a24nHa 24,000 btU/H ... · Air intake grille Air outlet hole Air...

  • Job Name: Location: Date:

    Purchaser: Engineer:

    Submitted to: For Reference Approval Construction

    Unit Designation: Schedule No.:

    Cooling*Rated Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24,000 Btu/hMinimum Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . .12,000 Btu/hSEER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13.6 Btu/h/WTotal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..2,500 WPower Supply . . . . . . . . . . . . . . . . . . . . 208 / 230V, 1-Phase, 60 HzBreaker Size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 A* Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB, 67ºF (19ºC) WB.Outdoor: 95ºF (35ºC) DB, 75ºF (24ºC) WB.

    VoltageIndoor - Outdoor S1-S2 . . . . . . . . . . . . . . . . . . . . . . AC 208 / 230VIndoor - Outdoor S2-S3 . . . . . . . . . . . . . . . . . . . . . . . . . . . .DC 24VIndoor - Remote Controller . . . . . . . . . . . . . . . . . . . . . . . . . .DC 12V

    Operating range

    Indoor Intake Air Temp. Outdoor Intake Air Temp.

    Cooling Maximum 95ºF (35ºC) DB, 71ºF (22ºC) WB

    115ºF (46ºC) DB

    Minimum 67ºF (19ºC) DB, 57ºF (14ºC) WB

    0ºF** (-18ºC) DB

    ** With optional wind baffle accessory installed. If not installed, the minimum temperature will be 23ºF (-5ºC) DB.

    Indoor Unit: PLA-A24BA

    Outdoor Unit: PUY-A24NHAindoor UnitMCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 A Fan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.51 F.L.A.Fan Motor Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 WAirflow (Lo - M1 - M2 - Hi) . . . . . . . 420 - 490 - 570 - 640 Dry CFM 390 - 460 - 530 - 600 Wet CFMSound Level (Lo - M1 - M2 - Hi) . . . . . . . . . . 28 - 29 - 31 - 32 dB(A)

    DiMenSiOnS Unit inCHeS / MM paneL inCHeS / MMW 33-1/16 / 840 37-3/8 / 950D 33-1/16 / 840 37-3/8 / 950H 10-3/16 / 258 1-3/8 / 35

    Weight (Unit/Grille)lbs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 / 13kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 / 6Field Drainpipe Size O.D. . . . . . . . . . . . . . . . . . . . . . 1-1/4" / 32 mmWall-mounted Remote Controller . . . . . . . . . . . . . . . . . PAR-21MAA

    (See Data Submittal Sheet)

    Outdoor UnitCompressor . . . . . . . . . . . . . . . . . . . . . . DC Inverter-driven RotaryMCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .…18 AFan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.75 F.L.A.Sound Pressure Level . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 dB(A)

    DiMenSiOnS inCHeS / MMW 37-3/8 / 950D 13 + 1-3/16 / 330 + 30H 37-1/8 / 943

    Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163 lbs. / 74 kgRefrigerant Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R410ARefrigerant Pipe Size O.D. Gas Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5/8" / 15.88 mm Liquid Side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/8" / 9.52 mmMax. Refrigerant Pipe Length. . . . . . . . . . . . . . . . . . . . . 165' / 50 mMax. Refrigerant Pipe Height Difference . . . . . . . . . . . . 100' / 30 mConnection Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flared

    SUbMittaL Data: pLa-a24ba & pUY-a24nHa 24,000 btU/H CeiLing CaSSette air-COnDitiOning SYSteM

    Remote Controller: PAR-21MAA

    OptiOnaL aCCeSSOrieSIndoor Unit•Multi-functionCasement(PAC-SH53TM-E)•AirOutletShutterPlates(PAC-SH51SP-E)•WirelessSignalReceiver(PAR-SA9FA-E)•WirelessRemoteController(PAR-FL32MA)•i-seeSensorCornerPanel(PAC-SA1ME-E)•High-efficiency(MERV10)Filter(PAC-SH59KF-E)Outdoor Unit•M-NETAdapter(PAC-SF80MA-E)•AirOutletGuide(PAC-SG59SG-E)•WindBaffle(WB-PA2)

    generaL FeatUreS•Compactside-dischargeoutdoorunit•Quietoperation—indoorandoutdoorunits•Built-indrainliftmechanismforcondensateremoval;liftsto33-7/16in.•Wideairflowpatternforbetterairdistribution•Autowaveairflowinheatingmode—unitindependentlycyclesthroughhorizontalandverticalpositionsformoreevenheatdistribution•Independentvaneadjustment•Automaticfanspeedcontrol•Self-checkfunction—integrateddiagnostics•Advancedmicroprocessorcontrol•Hard-wired,wall-mounted,remotecontroller(PAR-21MAA)•Limitedwarranty:oneyearonpartsanddefectsandsixyearson

    compressor

  • Dimensions: PLA-A24BA

    14-27/3211-3/162-3/8

    +5 0

    (7.5

    )

    +35

    -5

    (160)

    (500

    )

    (950

    )

    Floor

    Min.94-1/2(2400)from floor

    Entireperiphery

    (36)(83)

    (83)

    (36) (500)

    (950)

    (597

    )

    (597)

    ( 1

    58)

    (ø175)(350)

    (ø150)

    (14-ø2.8)

    (167

    )(1

    55)

    (130

    )(1

    00)(90) (90)

    (100) (100)

    (35)

    (17

    )

    +3/1

    60

    (190

    )

    (156

    )(1

    05)

    (50~

    70)

    (140

    )

    (170

    )

    (377)(284)(60)

    (24)

    (187.5)(840)

    (160)(1

    60)

    (20~

    45)

    to 1

    -25/

    32(8

    60~

    910)

    (620

    )

    (605

    )-3

    /16

    +1-

    3/8

    (90)

    (150

    )(1

    60)

    (7.5

    )

    (20 ~

    45)

    1-25

    /32

    Corner pocket

    In case of wireless remote controllerIn case of standard grilleDrain lift mechanism cleanhole and Drain emergency drainage hole

    For MA-Remote controllerterminal block

    Emergency operation switch

    Emergency operation switch

    Indoor unit

    Ceiling

    Cut out hole

    Burring hole pitch3-ø1/8(3-ø2.8)Burring hole

    Detail drawing of ventilation air intake connection

    Burring hole14-ø1/8

    Cut out hole

    Burring hole pitch

    Cut out hole

    Detail connecting of branch duct (nominal 6"round or nominal 4 x 14" rectangular)

    (77)3-1/32

    (85)3-11/32

    (298)11-3/411-1/16

    (281)

    (74)(80)(258)(241)2-29/323-5/3210-3/16

    PLA-A36BAPLA-A42BA

    PLA-A24BAPLA-A30BA

    9-1/2

    DCBA2

    Refrigerant pipe ····ø15.88mmFlared connection····5/8

    Refrigerant pipe ····ø12.7mmFlared connection····1/2

    1

    Refrigerant pipe ····ø6.35mmFlared connection····1/4

    Refrigerant pipe ····ø9.52mmFlared connection····3/8

    ModelsPLA-A12BAPLA-A18BA

    Min.19-11/16(500)

    Grille

    Ceiling

    Suspension bolt lower edge

    Vane motor

    Air intake grille

    Air outlet hole

    Air

    outle

    t hol

    e

    Auto vane(Air outlet)

    Air

    inta

    ke h

    ole

    Air intake hole

    GrilleCeiling

    Keep 25/64(10)to 19/32(15)between unit ceiling and ceiling slab.

    )(Connected the attachedflexible pipe or socket.Drainpipe connected to1-1/4 in. O.D. PVC tube

    Suspension bolt M10 or 3/8

    Branch duct hole

    Ventilation air intake hole

    Branch ducthole

    Cei

    ling

    hole

    Sus

    pens

    ion

    bolt

    pitc

    h

    Suspension bolt pitch

    Ceiling hole

    (5/1

    6)(5

    /16)

    23-1

    3/16

    24-1

    3/32

    DEFROST/STAND BY lampReceiverOperation lamp

    For wiring replacement kit terminal block

    6-5/16

    6-5/16

    1

    2

    3-15

    /16

    5-1/

    8

    13-25/32

    3-17/32

    3-15/16 3-15/16

    3-17/32

    * 6-9

    /16

    * 6-3

    /32

    ø5-29/32

    ø6-7/8

    19-11/16

    19-1

    1/16

    23-1/2

    M

    M

    M

    M

    3-17/641-27/64

    37-3/8

    3-17

    /64

    1-27

    /64

    37-3

    /8

    23-1

    /2

    1-15

    /16~

    2-3/

    4

    * 5-

    1/2

    * 6-

    11/16

    1-3/

    8

    11/1

    6

    * 4-

    1/8

    * 6-

    9/64

    * 7-

    15/3

    2 A

    * B

    6-5/

    16

    33-1

    /16(

    840)

    5-29

    /32

    3-17

    /32

    C D

    33-1/16

    7-3/8

    25/32 to 1-25/32(20~45)25/32 to 1-25/32(20~45) 33-27/32 to 35-13/16(860~910)

    31-7/8(810)

    25/3

    2 to

    33-2

    7/32

    to 3

    5-13

    /16

    25/3

    2

    15/1

    66-

    5/16

    Indoor unit/Outdoor unit connecting terminal block

    ø4-29/32(ø125)

    ø3-15/16(ø100)

    6-7/

    32 120

    ˚

    120˚

    **

    Note1. Use 1-1/4 in. O.D. (32) PVC TUBE.Drain lift mechanism is included.

    2. Suspension bolt, use M10 or W3/8. (Field supplied)

    3. Electrical box may be removed for service purposes.Make sure to slack the electrical wire little bit for control/power wires connection.

    4. The height of the indoor unit is adjustable with the grilleattached.

    5. For the installation of the optional high efficiency filter,the optional multi-functional casement is required.1) Add 5-5/16 (135mm) to the dimensions marked with an * in the figures 2) The optional high efficiency filter required optional

    multi-functional casement.6. When installing the branch ducts, be sure to insulate adequately.

    Otherwise condensation may occur.7. As for necessary installation/service space, please refer to the

    bottom left figure.

  • Min.

    10m

    m

    <3/

    8>M

    in. 1

    0mm

    Min.

    100

    mm

    M

    in. 5

    00m

    m

    Max.

    100mmMin.

    500mmMin.

    500m

    mM

    in.

    10m

    mM

    in.

    Ser

    vice

    spa

    ce

    30mm

    FOUN

    DATIO

    N

    FREE

    31

    74

    40

    Whe

    n in

    stal

    ling

    the

    cond

    uit,

    Set t

    he a

    ttach

    men

    t to

    the

    inne

    r sid

    e of

    eac

    h pa

    nel.

    1/2 C

    ondu

    it atta

    chme

    nt2-ø

    22.2<

    7/8>

    330

    175

    600

    175

    53

    28 370 19

    56

    45

    42 <

    1-21

    /32>

    66 <

    2-5/

    8>

    417

    2-U S

    hape

    d notc

    hed h

    ole(F

    ound

    fation

    Bolt

    M10

    )

    Side

    Air

    Inta

    ke

    Rear

    Air

    Inta

    ke

    Air D

    ischa

    rge

    2-12*

    36 ov

    al ho

    le(F

    ound

    ation

    Bolt

    M10

    )

    30

    Side A

    ir Inta

    ke

    Hand

    le

    Rear

    pipi

    ng co

    ver

    Fron

    t pipi

    ng co

    ver

    81219

    145

    22

    0 <

    8-21

    /32>

    30 <

    1-3/

    16>

    145

    71

    71 <

    2-13

    /16>

    145

    Botto

    m p

    iping

    hole

    (Kno

    ckou

    t)

    Drain

    hole

    (5-ø

    33

    )

    Hand

    le

    Hand

    le

    Rear

    Air In

    take

    Air

    Inta

    ke

    670

    *1 443

    *1 447

    322

    950

    473

    943

    23

    21

    Hand

    le

    Hand

    le

    Serv

    ice p

    anel

    Earth

    term

    inal

    Left··

    ·Pow

    er su

    pply

    wirin

    gRe

    ight···

    Indoo

    r/Outd

    oor w

    iring

    Term

    inal B

    lock

    63 73

    75

    40 <

    1-9/

    16>

    92

    9227 23

    55

    19

    Cond

    uit ho

    le (2-

    ø27<

    1-1/16

    >Kno

    ckou

    t)Ri

    ght tr

    unkin

    g hole

    (Kno

    ckou

    t)Ri

    ght p

    iping

    hole

    (Kno

    ckou

    t)

    ø92

    45

    65

    92

    40 <

    1-9/

    16>

    63

    2373

    55 27

    Cond

    uit ho

    le (2-

    ø27<

    1-1/16

    >Kno

    ckou

    t)

    Fron

    t trun

    king h

    ole(K

    nock

    out)

    Fron

    t pipi

    ng ho

    le(K

    nock

    out)

    ø92

    40 <

    1-9/

    16>

    45

    6373 23

    55 27

    92

    65

    Cond

    uit ho

    le (2-

    ø27<

    1-1/16

    >Kno

    ckou

    t)Re

    ar tru

    nking

    hole

    (Kno

    ckou

    t)

    Rear

    piping

    hole

    (Kno

    ckou

    t)

    ø92

    Pipi

    ng a

    nd w

    iring

    con

    nect

    ions

    can

    be m

    ade

    from

    4 d

    irect

    ions

    :fro

    nt, r

    ight

    , rea

    r and

    bel

    ow.

    Dim

    ensio

    ns o

    f spa

    ce n

    eede

    dfo

    r ser

    vice

    acce

    ss a

    resh

    own

    in th

    e be

    low

    diag

    ram

    .

    Plea

    se s

    ecur

    e th

    e un

    it fir

    mly

    with

    4 fo

    unda

    tion

    (M10

    )

    bolts

    . (Bo

    lts a

    nd w

    ashe

    rs m

    ust

    be p

    urch

    ased

    loca

    lly.)

    The

    diag

    ram

    bel

    ow s

    hows

    aba

    sic e

    xam

    ple.

    Expl

    antio

    n of

    par

    ticul

    ar d

    etai

    ls ar

    egi

    ven

    in th

    e in

    stal

    latio

    n m

    anua

    ls et

    c.

    1···

    ·Ref

    riger

    ant G

    AS p

    ipe

    conn

    ctio

    n (F

    LAR

    E)[1

    5.88

    2

    ····R

    efrig

    eran

    t LIQ

    UID

    pip

    e co

    nnec

    tion

    (FLA

    RE)[

    9.52

    *1

    ····I

    ndic

    atio

    n of

    STO

    P VA

    LVE

    conn

    ectio

    n lo

    catio

    n.

    Exam

    ple

    of N

    otes

    Pipi

    ng K

    nock

    out H

    ole

    Deta

    ils

    1 FR

    EE S

    PACE

    (Aro

    und

    the

    unit)

    2 SE

    RVIC

    E SP

    ACE

    3 FO

    UNDA

    TION

    BOL

    TS4

    PIPI

    NG-W

    IRIN

    G DI

    RECT

    IONS

    Dimensions: PUY-A24nHA

  • 3400 Lawrenceville Suwanee RdSuwanee, GA 30024Tele: 678-376-2900 • Fax: 800-889-9904Toll Free: 800-433-4822 (#3)www.mehvac.comSpecifications are subject to change without notice.C SD - PLA-A24BA / PUY-A24NHA - 200710 © MITSUBISHI ELECTRIC / HVAC 2007

    noTes

    Reference: OffApproval: OffConstruction: OffJob Name: Location: Date: Purchaser: Engineer: Submitted to: Unit Designation: Schedule No: Notes: