4
Job Name: Location: Date: Purchaser: Engineer: Submitted to: For Reference Approval Construction Unit Designation: Schedule No.: Cooling* Rated Capacity ............................... 24,000 Btu/h Minimum Capacity ............................ 12,000 Btu/h SEER ......................................13.6 Btu/h/W Total Input .......................................2,500 W Power Supply .................... 208 / 230V, 1-Phase, 60 Hz Breaker Size ........................................25 A * Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB, 67ºF (19ºC) WB. Outdoor: 95ºF (35ºC) DB, 75ºF (24ºC) WB. Voltage Indoor - Outdoor S1-S2 ...................... AC 208 / 230V Indoor - Outdoor S2-S3 ............................DC 24V Indoor - Remote Controller ..........................DC 12V OPERATING RANGE Indoor Intake Air Temp. Outdoor Intake Air Temp. Cooling Maximum 95ºF (35ºC) DB, 71ºF (22ºC) WB 115ºF (46ºC) DB Minimum 67ºF (19ºC) DB, 57ºF (14ºC) WB 0ºF** (-18ºC) DB ** With optional wind baffle accessory installed. If not installed, the minimum temperature will be 23ºF (-5ºC) DB. Indoor Unit: PLA-A24BA Outdoor Unit: PUY-A24NHA Indoor Unit MCA .............................................. 1 A Fan Motor ................................... 0.51 F.L.A. Fan Motor Output ................................... 50 W Airflow (Lo - M1 - M2 - Hi) ....... 420 - 490 - 570 - 640 Dry CFM 390 - 460 - 530 - 600 Wet CFM Sound Level (Lo - M1 - M2 - Hi) .......... 28 - 29 - 31 - 32 dB(A) DIMENSIONS UNIT INCHES / MM PANEL INCHES / MM W 33-1/16 / 840 37-3/8 / 950 D 33-1/16 / 840 37-3/8 / 950 H 10-3/16 / 258 1-3/8 / 35 Weight (Unit/Grille) lbs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 / 13 kg .............................................. 23 / 6 Field Drainpipe Size O.D...................... 1-1/4" / 32 mm Wall-mounted Remote Controller ................. PAR-21MAA (See Data Submittal Sheet) Outdoor Unit Compressor ...................... DC Inverter-driven Rotary MCA ............................................…18 A Fan Motor .................................... 0.75 F.L.A. Sound Pressure Level ............................ 48 dB(A) DIMENSIONS INCHES / MM W 37-3/8 / 950 D 13 + 1-3/16 / 330 + 30 H 37-1/8 / 943 Weight ................................... 163 lbs. / 74 kg Refrigerant Type .................................. R410A Refrigerant Pipe Size O.D. Gas Side ................................ 5/8" / 15.88 mm Liquid Side................................ 3/8" / 9.52 mm Max. Refrigerant Pipe Length..................... 165' / 50 m Max. Refrigerant Pipe Height Difference ............ 100' / 30 m Connection Method ................................ Flared SUBMITTAL DATA: PLA-A24BA & PUY-A24NHA 24,000 BTU/H CEILING CASSETTE AIR-CONDITIONING SYSTEM Remote Controller: PAR-21MAA OPTIONAL ACCESSORIES Indoor Unit • Multi-function Casement (PAC-SH53TM-E) • Air Outlet Shutter Plates (PAC-SH51SP-E) • Wireless Signal Receiver (PAR-SA9FA-E) • Wireless Remote Controller (PAR-FL32MA) • i-see Sensor Corner Panel (PAC-SA1ME-E) • High-efficiency (MERV 10) Filter (PAC-SH59KF-E) Outdoor Unit • M-NET Adapter (PAC-SF80MA-E) • Air Outlet Guide (PAC-SG59SG-E) • Wind Baffle (WB-PA2) GENERAL FEATURES • Compact side-discharge outdoor unit • Quiet operation—indoor and outdoor units • Built-in drain lift mechanism for condensate removal; lifts to 33-7/16 in. • Wide air flow pattern for better air distribution • Auto wave airflow in heating mode—unit independently cycles through horizontal and vertical positions for more even heat distribution • Independent vane adjustment • Automatic fan speed control • Self-check function—integrated diagnostics • Advanced microprocessor control • Hard-wired, wall-mounted, remote controller (PAR-21MAA) • Limited warranty: one year on parts and defects and six years on compressor

Transcript of SUbMittaL Data: pLa-a24ba & pUY-a24nHa 24,000 btU/H ... · Air intake grille Air outlet hole Air...

  • Job Name: Location: Date:

    Purchaser: Engineer:

    Submitted to: For Reference Approval Construction

    Unit Designation: Schedule No.:

    Cooling*Rated Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24,000 Btu/hMinimum Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . .12,000 Btu/hSEER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13.6 Btu/h/WTotal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..2,500 WPower Supply . . . . . . . . . . . . . . . . . . . . 208 / 230V, 1-Phase, 60 HzBreaker Size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 A* Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB, 67ºF (19ºC) WB.Outdoor: 95ºF (35ºC) DB, 75ºF (24ºC) WB.

    VoltageIndoor - Outdoor S1-S2 . . . . . . . . . . . . . . . . . . . . . . AC 208 / 230VIndoor - Outdoor S2-S3 . . . . . . . . . . . . . . . . . . . . . . . . . . . .DC 24VIndoor - Remote Controller . . . . . . . . . . . . . . . . . . . . . . . . . .DC 12V

    Operating range

    Indoor Intake Air Temp. Outdoor Intake Air Temp.

    Cooling Maximum 95ºF (35ºC) DB, 71ºF (22ºC) WB

    115ºF (46ºC) DB

    Minimum 67ºF (19ºC) DB, 57ºF (14ºC) WB

    0ºF** (-18ºC) DB

    ** With optional wind baffle accessory installed. If not installed, the minimum temperature will be 23ºF (-5ºC) DB.

    Indoor Unit: PLA-A24BA

    Outdoor Unit: PUY-A24NHAindoor UnitMCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 A Fan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.51 F.L.A.Fan Motor Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 WAirflow (Lo - M1 - M2 - Hi) . . . . . . . 420 - 490 - 570 - 640 Dry CFM 390 - 460 - 530 - 600 Wet CFMSound Level (Lo - M1 - M2 - Hi) . . . . . . . . . . 28 - 29 - 31 - 32 dB(A)

    DiMenSiOnS Unit inCHeS / MM paneL inCHeS / MMW 33-1/16 / 840 37-3/8 / 950D 33-1/16 / 840 37-3/8 / 950H 10-3/16 / 258 1-3/8 / 35

    Weight (Unit/Grille)lbs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 / 13kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 / 6Field Drainpipe Size O.D. . . . . . . . . . . . . . . . . . . . . . 1-1/4" / 32 mmWall-mounted Remote Controller . . . . . . . . . . . . . . . . . PAR-21MAA

    (See Data Submittal Sheet)

    Outdoor UnitCompressor . . . . . . . . . . . . . . . . . . . . . . DC Inverter-driven RotaryMCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .…18 AFan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.75 F.L.A.Sound Pressure Level . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 dB(A)

    DiMenSiOnS inCHeS / MMW 37-3/8 / 950D 13 + 1-3/16 / 330 + 30H 37-1/8 / 943

    Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163 lbs. / 74 kgRefrigerant Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R410ARefrigerant Pipe Size O.D. Gas Side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5/8" / 15.88 mm Liquid Side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/8" / 9.52 mmMax. Refrigerant Pipe Length. . . . . . . . . . . . . . . . . . . . . 165' / 50 mMax. Refrigerant Pipe Height Difference . . . . . . . . . . . . 100' / 30 mConnection Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flared

    SUbMittaL Data: pLa-a24ba & pUY-a24nHa 24,000 btU/H CeiLing CaSSette air-COnDitiOning SYSteM

    Remote Controller: PAR-21MAA

    OptiOnaL aCCeSSOrieSIndoor Unit•Multi-functionCasement(PAC-SH53TM-E)•AirOutletShutterPlates(PAC-SH51SP-E)•WirelessSignalReceiver(PAR-SA9FA-E)•WirelessRemoteController(PAR-FL32MA)•i-seeSensorCornerPanel(PAC-SA1ME-E)•High-efficiency(MERV10)Filter(PAC-SH59KF-E)Outdoor Unit•M-NETAdapter(PAC-SF80MA-E)•AirOutletGuide(PAC-SG59SG-E)•WindBaffle(WB-PA2)

    generaL FeatUreS•Compactside-dischargeoutdoorunit•Quietoperation—indoorandoutdoorunits•Built-indrainliftmechanismforcondensateremoval;liftsto33-7/16in.•Wideairflowpatternforbetterairdistribution•Autowaveairflowinheatingmode—unitindependentlycyclesthroughhorizontalandverticalpositionsformoreevenheatdistribution•Independentvaneadjustment•Automaticfanspeedcontrol•Self-checkfunction—integrateddiagnostics•Advancedmicroprocessorcontrol•Hard-wired,wall-mounted,remotecontroller(PAR-21MAA)•Limitedwarranty:oneyearonpartsanddefectsandsixyearson

    compressor

  • Dimensions: PLA-A24BA

    14-27/3211-3/162-3/8

    +5 0

    (7.5

    )

    +35

    -5

    (160)

    (500

    )

    (950

    )

    Floor

    Min.94-1/2(2400)from floor

    Entireperiphery

    (36)(83)

    (83)

    (36) (500)

    (950)

    (597

    )

    (597)

    ( 1

    58)

    (ø175)(350)

    (ø150)

    (14-ø2.8)

    (167

    )(1

    55)

    (130

    )(1

    00)(90) (90)

    (100) (100)

    (35)

    (17

    )

    +3/1

    60

    (190

    )

    (156

    )(1

    05)

    (50~

    70)

    (140

    )

    (170

    )

    (377)(284)(60)

    (24)

    (187.5)(840)

    (160)(1

    60)

    (20~

    45)

    to 1

    -25/

    32(8

    60~

    910)

    (620

    )

    (605

    )-3

    /16

    +1-

    3/8

    (90)

    (150

    )(1

    60)

    (7.5

    )

    (20 ~

    45)

    1-25

    /32

    Corner pocket

    In case of wireless remote controllerIn case of standard grilleDrain lift mechanism cleanhole and Drain emergency drainage hole

    For MA-Remote controllerterminal block

    Emergency operation switch

    Emergency operation switch

    Indoor unit

    Ceiling

    Cut out hole

    Burring hole pitch3-ø1/8(3-ø2.8)Burring hole

    Detail drawing of ventilation air intake connection

    Burring hole14-ø1/8

    Cut out hole

    Burring hole pitch

    Cut out hole

    Detail connecting of branch duct (nominal 6"round or nominal 4 x 14" rectangular)

    (77)3-1/32

    (85)3-11/32

    (298)11-3/411-1/16

    (281)

    (74)(80)(258)(241)2-29/323-5/3210-3/16

    PLA-A36BAPLA-A42BA

    PLA-A24BAPLA-A30BA

    9-1/2

    DCBA2

    Refrigerant pipe ····ø15.88mmFlared connection····5/8

    Refrigerant pipe ····ø12.7mmFlared connection····1/2

    1

    Refrigerant pipe ····ø6.35mmFlared connection····1/4

    Refrigerant pipe ····ø9.52mmFlared connection····3/8

    ModelsPLA-A12BAPLA-A18BA

    Min.19-11/16(500)

    Grille

    Ceiling

    Suspension bolt lower edge

    Vane motor

    Air intake grille

    Air outlet hole

    Air

    outle

    t hol

    e

    Auto vane(Air outlet)

    Air

    inta

    ke h

    ole

    Air intake hole

    GrilleCeiling

    Keep 25/64(10)to 19/32(15)between unit ceiling and ceiling slab.

    )(Connected the attachedflexible pipe or socket.Drainpipe connected to1-1/4 in. O.D. PVC tube

    Suspension bolt M10 or 3/8

    Branch duct hole

    Ventilation air intake hole

    Branch ducthole

    Cei

    ling

    hole

    Sus

    pens

    ion

    bolt

    pitc

    h

    Suspension bolt pitch

    Ceiling hole

    (5/1

    6)(5

    /16)

    23-1

    3/16

    24-1

    3/32

    DEFROST/STAND BY lampReceiverOperation lamp

    For wiring replacement kit terminal block

    6-5/16

    6-5/16

    1

    2

    3-15

    /16

    5-1/

    8

    13-25/32

    3-17/32

    3-15/16 3-15/16

    3-17/32

    * 6-9

    /16

    * 6-3

    /32

    ø5-29/32

    ø6-7/8

    19-11/16

    19-1

    1/16

    23-1/2

    M

    M

    M

    M

    3-17/641-27/64

    37-3/8

    3-17

    /64

    1-27

    /64

    37-3

    /8

    23-1

    /2

    1-15

    /16~

    2-3/

    4

    * 5-

    1/2

    * 6-

    11/16

    1-3/

    8

    11/1

    6

    * 4-

    1/8

    * 6-

    9/64

    * 7-

    15/3

    2 A

    * B

    6-5/

    16

    33-1

    /16(

    840)

    5-29

    /32

    3-17

    /32

    C D

    33-1/16

    7-3/8

    25/32 to 1-25/32(20~45)25/32 to 1-25/32(20~45) 33-27/32 to 35-13/16(860~910)

    31-7/8(810)

    25/3

    2 to

    33-2

    7/32

    to 3

    5-13

    /16

    25/3

    2

    15/1

    66-

    5/16

    Indoor unit/Outdoor unit connecting terminal block

    ø4-29/32(ø125)

    ø3-15/16(ø100)

    6-7/

    32 120

    ˚

    120˚

    **

    Note1. Use 1-1/4 in. O.D. (32) PVC TUBE.Drain lift mechanism is included.

    2. Suspension bolt, use M10 or W3/8. (Field supplied)

    3. Electrical box may be removed for service purposes.Make sure to slack the electrical wire little bit for control/power wires connection.

    4. The height of the indoor unit is adjustable with the grilleattached.

    5. For the installation of the optional high efficiency filter,the optional multi-functional casement is required.1) Add 5-5/16 (135mm) to the dimensions marked with an * in the figures 2) The optional high efficiency filter required optional

    multi-functional casement.6. When installing the branch ducts, be sure to insulate adequately.

    Otherwise condensation may occur.7. As for necessary installation/service space, please refer to the

    bottom left figure.

  • Min.

    10m

    m

    <3/

    8>M

    in. 1

    0mm

    Min.

    100

    mm

    M

    in. 5

    00m

    m

    Max.

    100mmMin.

    500mmMin.

    500m

    mM

    in.

    10m

    mM

    in.

    Ser

    vice

    spa

    ce

    30mm

    FOUN

    DATIO

    N

    FREE

    31

    74

    40

    Whe

    n in

    stal

    ling

    the

    cond

    uit,

    Set t

    he a

    ttach

    men

    t to

    the

    inne

    r sid

    e of

    eac

    h pa

    nel.

    1/2 C

    ondu

    it atta

    chme

    nt2-ø

    22.2<

    7/8>

    330

    175

    600

    175

    53

    28 370 19

    56

    45

    42 <

    1-21

    /32>

    66 <

    2-5/

    8>

    417

    2-U S

    hape

    d notc

    hed h

    ole(F

    ound

    fation

    Bolt

    M10

    )

    Side

    Air

    Inta

    ke

    Rear

    Air

    Inta

    ke

    Air D

    ischa

    rge

    2-12*

    36 ov

    al ho

    le(F

    ound

    ation

    Bolt

    M10

    )

    30

    Side A

    ir Inta

    ke

    Hand

    le

    Rear

    pipi

    ng co

    ver

    Fron

    t pipi

    ng co

    ver

    81219

    145

    22

    0 <

    8-21

    /32>

    30 <

    1-3/

    16>

    145

    71

    71 <

    2-13

    /16>

    145

    Botto

    m p

    iping

    hole

    (Kno

    ckou

    t)

    Drain

    hole

    (5-ø

    33

    )

    Hand

    le

    Hand

    le

    Rear

    Air In

    take

    Air

    Inta

    ke

    670

    *1 443

    *1 447

    322

    950

    473

    943

    23

    21

    Hand

    le

    Hand

    le

    Serv

    ice p

    anel

    Earth

    term

    inal

    Left··

    ·Pow

    er su

    pply

    wirin

    gRe

    ight···

    Indoo

    r/Outd

    oor w

    iring

    Term

    inal B

    lock

    63 73

    75

    40 <

    1-9/

    16>

    92

    9227 23

    55

    19

    Cond

    uit ho

    le (2-

    ø27<

    1-1/16

    >Kno

    ckou

    t)Ri

    ght tr

    unkin

    g hole

    (Kno

    ckou

    t)Ri

    ght p

    iping

    hole

    (Kno

    ckou

    t)

    ø92

    45

    65

    92

    40 <

    1-9/

    16>

    63

    2373

    55 27

    Cond

    uit ho

    le (2-

    ø27<

    1-1/16

    >Kno

    ckou

    t)

    Fron

    t trun

    king h

    ole(K

    nock

    out)

    Fron

    t pipi

    ng ho

    le(K

    nock

    out)

    ø92

    40 <

    1-9/

    16>

    45

    6373 23

    55 27

    92

    65

    Cond

    uit ho

    le (2-

    ø27<

    1-1/16

    >Kno

    ckou

    t)Re

    ar tru

    nking

    hole

    (Kno

    ckou

    t)

    Rear

    piping

    hole

    (Kno

    ckou

    t)

    ø92

    Pipi

    ng a

    nd w

    iring

    con

    nect

    ions

    can

    be m

    ade

    from

    4 d

    irect

    ions

    :fro

    nt, r

    ight

    , rea

    r and

    bel

    ow.

    Dim

    ensio

    ns o

    f spa

    ce n

    eede

    dfo

    r ser

    vice

    acce

    ss a

    resh

    own

    in th

    e be

    low

    diag

    ram

    .

    Plea

    se s

    ecur

    e th

    e un

    it fir

    mly

    with

    4 fo

    unda

    tion

    (M10

    )

    bolts

    . (Bo

    lts a

    nd w

    ashe

    rs m

    ust

    be p

    urch

    ased

    loca

    lly.)

    The

    diag

    ram

    bel

    ow s

    hows

    aba

    sic e

    xam

    ple.

    Expl

    antio

    n of

    par

    ticul

    ar d

    etai

    ls ar

    egi

    ven

    in th

    e in

    stal

    latio

    n m

    anua

    ls et

    c.

    1···

    ·Ref

    riger

    ant G

    AS p

    ipe

    conn

    ctio

    n (F

    LAR

    E)[1

    5.88

    2

    ····R

    efrig

    eran

    t LIQ

    UID

    pip

    e co

    nnec

    tion

    (FLA

    RE)[

    9.52

    *1

    ····I

    ndic

    atio

    n of

    STO

    P VA

    LVE

    conn

    ectio

    n lo

    catio

    n.

    Exam

    ple

    of N

    otes

    Pipi

    ng K

    nock

    out H

    ole

    Deta

    ils

    1 FR

    EE S

    PACE

    (Aro

    und

    the

    unit)

    2 SE

    RVIC

    E SP

    ACE

    3 FO

    UNDA

    TION

    BOL

    TS4

    PIPI

    NG-W

    IRIN

    G DI

    RECT

    IONS

    Dimensions: PUY-A24nHA

  • 3400 Lawrenceville Suwanee RdSuwanee, GA 30024Tele: 678-376-2900 • Fax: 800-889-9904Toll Free: 800-433-4822 (#3)www.mehvac.comSpecifications are subject to change without notice.C SD - PLA-A24BA / PUY-A24NHA - 200710 © MITSUBISHI ELECTRIC / HVAC 2007