Sdr Gulmt Commitioning

Post on 23-Oct-2015

31 views 2 download

Tags:

description

ZTE 8890 commitioning

Transcript of Sdr Gulmt Commitioning

Commissioning Of SDR BTS

8800 & 8900

1) Turn OFF WINDOWS FIREWALL2) Turn OFF ANTIVIRUS

• If you wish to logging in the CC1 (Bottom)Set LAPTOP IP :192.254.1.18 (For CC1)Subnet Mask :255.255.255.0 (For CC1)

If you wish to logging in the CC2 (Upper) Set LAPTOP IP : 192.254.2.18 ( For CC2)Subnet Mask :255.255.255.0 ( For CC2)

If you are logging in the CC1 (Bottom)Set IP(LMT) :192.254.1.16 (For CC1)

Logging into CC2 (Upper)Set IP(LMT): 192.254.2.16 ( For CC2)

After Set IP in Local Area Connection,connect LAN cable to CC

card in ETH 1 port. After connecting cable you just check LED status at

extreme leftside of card in which eth1 is continuously blinking.

Go to LMT Software ,click on LMT START

Select Version :4.00.210eP01(Use DEFAULT Version)

Select Station:For CC1 :192.254.1.16

CC2: 192.254.2.16

click on online configuration >>> RUN Version

For 8800: As you select model 8800 it shows rack now you need to create card ( if cards not

created )

Create Card In respective slot

Create Card :Right Click on slotthen add board

select boardok

commissioning procedure is same for all BTS Right Click on Base Station

Click on Configure basic attribution

Node B Id: Put Site ID

SNTP Server Address : 139. BSC No. .1 .200

Transmission Mode : Select IP

Radio Mode : Select GSM

GSM Station No. : Site IDE1/T1 Medium : E1

Time Zone : Select GMT +5:30

Click On E1/T1 Link : Right Click And Add Link ID : Select 0 (here no need to use 1,2,3)

Link Type: Select BSC

For HDLC Parameter : Right Click and add

Click On PPP Parameter :Right Click and add and

PPP encapsulation : Select ML-PPP

HDLC Link Id: Select Link 0 Base Station IP: Put Base Station IP

(118.BSC ID. HDLC No. 200 )

Click On Global Parameter :Right Click and add

Working Mode : Change to IP Over PPP

Click On IP parameter : Right Click and Add and OK

SCTP Parameter Management :Right click and add Local Port ID : It should be site id

Remote port ID :14592+Module no.Remote IP address: RPU IP ( 118. BSC ID. 1. 1 )

Click On OMC-B parameter: Right Click and add Operation and maintenace Gateway ip: Put RPU

IP ( 118. BSC ID. 1. 1 )

For Export Config file