Presentation… Hydronics Ltd. Family of Products. CAMUS Hydronics is a world renowned manufacturer...

Post on 31-Mar-2015

233 views 0 download

Tags:

Transcript of Presentation… Hydronics Ltd. Family of Products. CAMUS Hydronics is a world renowned manufacturer...

Presentation…

Hydronics Ltd.

Family of ProductsFamily of Products

CAMUS Hydronics is a world renowned manufacturer of Industrial,

Commercial and ResidentialBoilers and Water Heaters.

The CAMUS corporate head office,manufacturing plant and warehouse

are housed under one roof in amodern 68,000 square foot facility.

CAMUS products are constructedusing state of the art components

and high quality materials, engineeredto operate with maximum efficiency,

providing years of dependable service.

The CAMUS Product Development Teamis comprised of the very best engineersand hydronic specialists in the industry,

continually setting higher standardswith every new product release.

The CAMUS CERTIFIED Sealassures you that

RELIABILITYEFFICIENCY

andSERVICEABILITY

are built into every unit.

CAMUS Hydronics is also a manufacturerof replacement parts for

most copper finned water heatersand heating boilers as well as a

supplier of specialty HVAC products.

The CAMUS SERVICE LINEis open 24 hours a day

7 days a week!

Extremely Low NOx!

THE DYNAFLAME ISAVAILABLE IN CONDENSING,

NON-CONDENSING AND NEAR-CONDENSING MODELS WITH

CAPACITIES RANGING FROM500 UP TO 5,000 MBUTH!

Gas Fired Commercial Copper Tube Boilersfor Hydronic Heating and Hot Water Supply

Standard Features

85% Efficiency (non-condensing) & 95% (condensing)

Suitable for Category 1 Installation

All Bronze and Copper Water Surfaces

Range of Burner Modulation of 20 – 100% (condensing)

Range of Burner Modulation of 35 - 100% (non-condensing)

Single Point Input Adjustment for Controlling Air and Gas

1 to 1 Gas/Air Ratio for perfect modulation throughout

Extremely low NOx Emissions Exceeding Air Quality

Standards (less than 10 PPM)

Flow Switch

Standard Features(continued)

Very Small Footprint

Extremely Low Noise Level of Operation

Metal Fiber Knit Burner

Stainless Steel Outer Jacket & Combustion Chamber

Advanced Digital Control System with Pin Point Accuracy

Proven Hot Surface Ignition w/Soft Start for Rumble Free

Operation

Designed for Easy Access to Components for Maximum

Serviceability

Gasket-less Heat Exchanger Design

Standard Features(continued)

Maximum Allowable Working Pressure of 160 PSI

Maximum Operating Water temperature of 250°F

24 volt Circuit Breaker

Protective Air Filter

Very low Gas Pressure Operation (down to 2” pressure inlet)

Main Burner Test Firing Valve

Temperature and Pressure Gauge

Inspected and Tested to ASME Requirements

Pressure Relief Valve

Optional Equipment

Secondary Exchanger for Condensing

Operation at 95% Efficiency

High Gas Pressure Switch

Low Gas Pressure Switch

Normally Open Vent Valve

Low Water Cut-Off

Flame Failure Alarm

Pump Delay

Outdoor Installation

Cupro Nickel Heat Exchanger

(standard on models 3500 and up)

Cross Sectionals

Control Panel

Advanced digital display control w/pin point accuracy

Multi point diagnostic light package allowing forSimple troubleshooting

Three pre-set modes of operation: Mode 1 for heating,Mode 2 for domestic hot water heating and Mode 3 forOperation by a remote controller

Adjustable pump delay feature based on a Temp.,

difference between inlet and outlet temperatures.

Displays inlet temperature, outlet temperature,

temperature rise, error messages and run time

Flame failure signal

Optional tank mounted sensor used in conjunction

with inlet sensor for domestic hot water application

Many more built-in features

Venting

Venting

Specifications

DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE

Heat Exchanger Head Loss & Flow

Recovery Capacities

MBTU Input and Output

Dimensional Specifications

Shipping Weights

www.camus-hydronics.comwww.camus-hydronics.com

Gas Fired Residential / Light Commercial Copper Tube Boilersfor Hydronic Heating and Hot Water Supply

For Hydronic Heating – Models MFH60, 100, 150, 200, 250, 300, 400, 500, 600

For Hot Water Supply – Models MFW60, 100, 150, 200, 250, 300, 400, 500, 600

Performance Highlights

Low NOx

Up to 85% Efficiency – Non-Condensing Mode

Durable Ceramic Burner Unaffected by High Temperatures

Vents up to 60 Feet Horizontally with 50 Feet of Air Intake Duct

Suitable for Use in Negative Pressure Environments

Input Range From 60 to 600 MBTUH

Complete Diagnostic Light Package

Up to 95% Efficiency – Condensing Mode

Easy Access for Inspection and Cleaning of Heat Exchanger Tubes

Durable Ceramic Fiber Refractory

Simple to Service With Easy Access to Burner and Fan

Control Panel

Accurate Proportional ControlW/2-Stage Option

Incorporates Auto Reset High

Limit and Operator

Three Modes of Operation:

Heating, DHW & Remote

Port for Optional Tank Sensor

Displays Inlet/Outlet Temperatures and Delta Temperature

* The Smartflame 780007 Control Panel

is Optional

Optional Pump Delay

Flame Failure Feature

Displays Total Run HRS

Molex® Harness Connection for Ease of Service

Specifications

DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE

Heat Exchanger Head Loss & Flow

Recovery Capacities

MBTU Input and Output

Dimensional Specifications

Shipping Weights

www.camus-hydronics.comwww.camus-hydronics.com

For Hydronic Heating – Models MFH800, 1000, 1200, 1400, 1600, 1800, 2000

For Hot Water Supply – Models MFW800, 1000, 1200, 1400, 1600, 1800, 2000

Gas Fired Residential / Light Commercial Copper Tube Boilersfor Hydronic Heating and Hot Water Supply

Low NOx

Up to 85% Efficiency – Non-Condensing Mode

Durable Ceramic Burner Unaffected by High Temperatures

Vents up to 60 Feet Horizontally with 60 Feet of Air Intake Duct

Suitable for Use in Negative Pressure Environments

Input Range From 800 to 2000 MBTUH

Complete Diagnostic Light Package

Up to 95% Efficiency – Condensing Mode

Easy Access for Inspection and Cleaning of Heat Exchanger Tubes

Durable Ceramic Fiber Refractory

Simple to Service With Easy Access to Burner and Fan

Performance Highlights

Control Panel

Accurate Proportional Controlwith up to 4-Stage Option

Incorporates Auto Reset HighLimit and Operator

Port for Optional Tank Sensor

Displays Inlet/Outlet Temp’s

and Delta Temperature

Optional Pump Delay

Flame Failure Feature

Displays Total Run HRS

Molex® Harness Connection for Ease of Service

Weather Proof Enclosure

Fusible Link for Over-Voltage

Six Modes of Operation, forOutdoor Reset, Heating, DHWand Remote

Proven Field Performance

Firing Modes Available:

Models 800 - 1000 On / Off2-Stage

Models 1200 – 2000 On / Off2-Stage3-Stage

4-Stage

Specifications

DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE

Heat Exchanger Head Loss & Flow

Recovery Capacities

MBTU Input and Output

Dimensional Specifications

Shipping Weights

www.camus-hydronics.comwww.camus-hydronics.com

For Hydronic Heating – Models MFNH2000, 2500, 3000, 3500, 4000

For Hot Water Supply – Models MFNW2000, 2500, 3000, 3500, 4000

Gas Fired Commercial / Commercial Copper Tube Boilersfor Hydronic Heating and Hot Water Supply

Low NOx

Up to 85% Efficiency – Non-Condensing Mode

Durable Ceramic Burner Unaffected by High Temperatures

Vents up to 60 Feet Horizontally with 60 Feet of Air Intake Duct

Suitable for Use in Negative Pressure Environments

Input Range From 2000 to 4000 MBTUH

Complete Diagnostic Light Package

Up to 95% Efficiency – Condensing Mode

Easy Access for Inspection and Cleaning of Heat Exchanger Tubes

Durable Ceramic Fiber Refractory

Simple to Service With Easy Access to Burner and Fan

Accurate Proportional ControlWith Up To 4-Stage OptionIncorporates Auto Reset HighLimit and Operator

Port for Optional Tank Sensor

Displays Inlet/Outlet Temp’sAnd Delta Temperature

Optional Pump Delay

Flame Failure Feature

Displays Total Run HRS

Molex® Harness Connection for Ease of Service

Weather Proof Enclosure

Fusible Link for Over-Voltage

Six Modes of Operation, forOutdoor Reset, Heating, DHW, and Remote

Proven Field Performance

Firing Modes Available:Models 2000 - 4000 On / Off

2-Stage3-Stage4-Stage

Specifications

DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE

Heat Exchanger Head Loss & Flow

Recovery Capacities

MBTU Input and Output

Dimensional Specifications

Shipping Weights

www.camus-hydronics.comwww.camus-hydronics.com

Gas Fired Commercial / Commercial Copper Tube Boilersfor Hydronic Heating and Hot Water Supply

Gas Fired Commercial Copper Tube Boilers

For Hydronic Heating and Hot Water Supply

For Hydronic Heating – Models CFH450, 550, 650

For Hot Water Supply – Models CFW450, 550, 650

Low NOx

Up to 85% Efficiency

Minimum Standby Losses with EstimatedAverage AFUE Efficiencies of 82%

Durable Ceramic Burner not Affected by

Overheating

Vents up to 60 Feet Horizontally with 60 Feet ofIntake Air Duct

Suitable for Use in Negative Pressure Environments

Input Range From 450 to 650 MBTUH

Complete Diagnostic Light Package

Simple to Service With Easy Access to Burner

Performance Highlights

2-Stage Proportional Control

Incorporates Auto Reset High Limit & Operator

Three Modes of Operation – Heating, DHW and Remote

Port for Optional Tank Sensor

Flame Failure Feature

Displays Inlet/Outlet Temperatures and

Delta Temperature

Displays Total Run Hours

Snap on Molex Connection for Easy Service

Weather Proof Enclosure

Fusible Link for Over-Voltage

Specifications

DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE

Heat Exchanger Head Loss & Flow

Recovery Capacities

MBTU Input and Output

Dimensional Specifications

Shipping Weights

www.camus-hydronics.comwww.camus-hydronics.com

Gas Fired Commercial Copper Tube BoilersFor Hydronic Heating and Hot Water Supply

For Hydronic Heating – Models BFH480, 660, 840, 1020, 1200, 1380, 1560, 1740, 1950

For Hot Water Supply – Models BFW480, 660, 840, 1020, 1200, 1380, 1560, 1740, 1950

Diagnostic Lights Help Troubleshoot Over the Phone

Durable Stainless Steel Burners

Adaptable to Outdoor Use

Simple to Service

Slide Out Burner Tray

Easy Side Access for Inspection of Combustion Chamber

Optional Digital Temperature Control is Extremely Accurate to

Minimize Standby Losses From Temperature Overshoot

High Temperature Ceramic Fiber Tiles in Combustion Chamber

Very Smooth and Quiet Operation

Suitable for Venting in Low Ceiling Applications with Use of

Power Venter and Low Profile Hood

Efficiencies of up to 83%

Incorporates Auto Reset HighLimit & Operator

Three Modes of Operation:Heating, DHW and Remote

Port for Optional Tank Sensor

Flame Failure Feature

Displays Inlet/Outlet Temp’sAnd Delta Temperature

Displays Total Run Hours

Snap on Molex® ConnectionFor Easy Service

Fusible Link for Over-VoltageProtection

* The Smartflame 780007 Control PanelIs Optional

Venting

Specifications

DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE

Heat Exchanger Head Loss & Flow

Recovery Capacities

MBTU Input and Output

Dimensional Specifications

Shipping Weights

www.camus-hydronics.comwww.camus-hydronics.com

Gas Fired Commercial Copper Tube BoilersFor Hydronic Heating and Hot Water Supply

For Hydronic Heating – Models SFH420, 520, 600

For Hot Water Supply – Models SFW420, 520, 600

Temperature control is extremely accurate tominimize standby losses from temp. overshoot

Diagnostic lights help troubleshoot over the phone

Input Range From 420 to 600 MBTUH

Burner runs cool and requires minimum maintenance

Adaptable to outdoor use

Simple to service

Very smooth and quiet operation

Fully enclosed combustion chamber

Suitable for venting in low ceiling applicationsWith use of power venter and low profile hood

Efficiencies up to 83%

Incorporates Auto Reset High Limit & Operator

Three Modes of Operation – Heating, DHW and Remote

Port for Optional Tank Sensor

Flame Failure Feature

Displays Inlet/Outlet Temperatures and Delta Temperature

Displays Total Run Hours

Snap on Molex Connection for Easy Service

Weather Proof Enclosure

Fusible Link for Over-Voltage Protection

Venting

Specifications

DETAILED SPECIFICATIONS AVAILABLEONLINE AND IN PRINTED LITERATURE

Heat Exchanger Head Loss & Flow

Recovery Capacities

MBTU Input and Output

Dimensional Specifications

Shipping Weights

www.camus-hydronics.comwww.camus-hydronics.com

Standard Features

Constant or Outdoor Reset temperature control

Optional heating load matching software

Domestic target water temperature limit to prevent

boiler condensation or to maintain domestic hot water

heat exchanger temperature

Maximum target water temperature limit to prevent

individual boiler limit tripping

Warm weather shutdown of boilers and main pump(s)

Controls any type or combination of modulating & staging

boilers – 12 outputs per controller – each modulating boiler

uses 2 outputs, each staging boiler uses 1 output per stage;

each pump uses 1 output. Some possible controlconfigurations for a single controller application include:

- controls up to 6 modulating boilers- controls up to 5 modulating boilers + 2 main pumps- controls up to 4 modulating boilers

+ 2 single stage boilers + 2 main pumps- controls up to 3 modulating boilers + 3 two-stage boilers

Standard Features(CONTINUED)

Runtime based lead / lag control of boilers, regardless of type

Master – Slave arrangement allows for additional

controllers to be added to increase the boiler control

capability. In this manner, with 2 controllers, 24 outputs

are available (up to 12 mod boilers, or combination ofmod and staging boilers)

Totally custom firing sequences available to allow high

efficiency boilers to fire first followed by less efficient boilers

Runtime based lead / lag control of main system pumps,

comes with flow sensing & automatic lag pump switch-over

in case lead pump should fail

Standard Features(CONTINUED)

Lock & key(s) to prevent unauthorized editing of parameters

EMS (Energy Management System) interfaces:

- enable / disable of heating controller (EMS enables or

disables heating system

- remote set point control of heating system (EMS providesone control override (DO) and one 0-20ma signal (AO)to Stage-Mod to take full control of Stage-Mod target

temperature)

Web / LAN server interface allowing each controller tocommunicate to any PC web-browser application

Custom serial protocols available

Optional Features

Remote Set-point Option Allows EMS interfacing

to Stage-Mod

Web Server Option Web / LAN server module

for Stage-Mod

Customizing Options(s) Project specific customization

available on request

Add On Options

LCD Display

Power On

Outdoor Temperature

System Water Temperature

Target Water Temperature

Set Point

Ratio Setting

Throttling

Outdoor Start-up Temperature

System Water Temperature

Standard Features

Indoor / Outdoor Sensors are solid state and capable of maintaining accuracy at a maximum wire length of 4,000 feet of shielded cable

Power Relays are Socket - Mounted and replaceable on site

Control is equipped with Boiler Override and Boiler By-Pass Switches

Capable of Fully Modulating the Gas Input of the Boilers

Automatically shuts down the heating unts as a Preset Outdoor Temperature which is variable between 50 and 100° F

Can be mounted in an enclosure suitable for wall mounting

Has a Minimum Boiler Water Temperature Setting independent of and  capable of Overriding the Scheduled Function. This setting is variable  between 90 and 150°F

Standard Features (cont’d)

Allows for Automatic Switching of the Lead Boiler

LED liights on the front door panel to indicate a "Boiler in Fault" alarm

Control is equipped with Boiler Override and Boiler By-Pass Switches

All Boiler Status Information is accessible from a Remote Location via the  CM8 Central Control Panel

Boiler Control communicates through the "Camus Communication Interface"  to LonWorks, BACnet and other systems.

Thank-You!