Post on 23-Aug-2020
UP UP
SW
EE
T A
VE
.
WELLS ST.
WELLS ST.
WIL
LIA
MS
A
VE
.
LO
CU
ST
ST
.
LO
CU
ST
ST
.
RE
SE
AR
CH
RD
.
STANDLEY DR.W
OOTEN
DR.
STANDLEY D
R.
SWEET AVE.
MCARTHU
R DR.
ST
AN
DL
EY
DR
.
MC
AR
TH
UR
DR
.
FIT
E D
R.
CLY
DE
TO
MBA
UG
H A
VE.
UN
IVERSIT
Y AVE
.
SAM STEELE W
AY
UNIVERSITY AVE.
WELLS ST.
WELLS ST.
UNIVERSITY AVE.
ES
PIN
A
ST
.
ES
PIN
A
ST
.
UNIVERSITY AVE.
GREGG ST.
WE
DD
EL
S
T.
STEWART ST.
GREGG ST.
COLLEGE AVE.
STEWART ST.
STEWART ST.
STEWART ST.
COLLEGE AVE.
CO
LL
EG
E A
VE
.
WIL
LIA
MS
A
VE
.
WIL
LIA
MS A
VE.
BR
EL
AN
D D
R.
SW
EE
T
AV
E.
SW
EE
T
AV
E.
SAM STEELE W
AY
SAM STEELE W
AY
SAM STEELE W
AY
INTERSTATE 10
INTERSTATE 10
INTERSTATE 10
I NT
ER
ST
AT
E 2
5
KN
OX
ST
.
KN
OX
ST
.
AR
RO
WH
EA
D D
R.
AR
RO
WH
EA
D D
R.
AR
RO
WH
EA
D D
R.
ARRO
WH
EA
D D
R.
LO
CU
ST
ST
.
RE
SE
AR
CH
RD
.STANDLEY DR.
CE
NT
ER
DR
.
PO
E D
R.
WO
OT
EN
DR
.
WIMBERLY ST.
EL
PA
SE
O R
D.
EL
PA
SE
O R
D.
TR
IVIZ
DR
.
TR
IVIZ
DR
.
TR
IVIZ
DR
.
CHOLLA RD.
RESEA
RCH
PARK
CIR.
LO
WE
RY
DAV
IS A
VE
.
JAC
K W
AR
D A
VE
.
BA
RB
AR
A L
EE M
YE
RS
AVE
.
UNION AVE.
UNIVERSITY A
VE.
COLLEGE AVE.
CONWAY A
VE.
HA
RR
EL
SO
N S
T.
MA
IN S
T.
BO
WM
AN
ST
.
BO
WM
AN
ST
.
HA
RR
EL
SO
N S
T.
ES
PIN
A
ST
.
WIL
LIA
MS
A
VE
.
ES
PIN
A
ST
.
STEWART ST.
UNIVERSITY AVE.
UNIVERSITY AVE.
AR
RO
WH
EA
D D
R.
LO
CU
ST
ST
.
JOR
DA
N R
D.
TRIVIZ DR.
GEOTHERMAL DR.
KN
OX
ST
.
NORTH HORSE SHOE ST.
SOUTH HORSE SHOE ST.
SEE A-203 FORENTRY FEATURES
1
ALT 3: RESIDENTIAL WING UPGRADES - DURABILITY
ALT 1: S WING
ALT 2: N TOWER (SEE ROOF)
ALT 4: RESIDENTIAL WING UPGRADES
ALT 6: SITE - PRIORITY 1 LANDSCAPE
ALT 5: S WINGUPGRADE
ALT 8: SITE - PRIORITY 2 LANDSCAPE
ALT 7: S WINGTECHNOLOGY
SEE SPECIFICATION SECTION 01 20 00 "PRICE AND PAYMENTPROCEDURES" FOR ALTERNATE PROCEDURES.
SOUTH WING - CLASSROOMS, SOUTH LOBBY & OFFICESINCLUDE CREDIT FOR EAST/WEST ARCADE (BASE BID WORK NOTBUILT IF ALT IS INCL IN CONSTR AWARD.
RESIDENTIAL WING - NORTH TOWER
RESIDENTIAL WING UPGRADES - EXTERIOR DESIGN & LEED EIFS ACCENT @ WINDOWS BICYCLE STORAGE SYSTEMS RECYCLING AREA, TYP OF (4) FOUR CORNER GUARDS
RESIDENTIAL WING UPGRADES - INTERIOR DURABILITY SOUND MAT AT RESIDENTIAL ROOM BATH AREA SHOWER DOOR IN LIEU OF SHOWER ROD 7 CURTAIN KNOCK-DOWN METAL FRAME & SOLID CORE DOOR @ BATH AREAS (IN LIEU OF WOOD FRAME/HOLLOW CORE DOOR)
RESIDENTIAL WING UPGRADES - INTERIOR CORRIDOR & LOUNGE CEILING UPGRADES GYP BD ACCENTS @ CORRIDORS & LOUNGES ACCENT LIGHTING CUSTOM RECESSED ACRYLIC BOX @ SHOWERS RECESSED CASEWORK AT BATH AREA REMOVEABLE CASEWORK AT VANITY INCREASED SOUND ATTENUATION AT FLOOR/CEILING
SOUTH WING UPGRADE LVT AT CORRIDOR AND LOUNGE IN LIEU OF SEALED CONCRETE CLASSROOM GLAZING AT COORIDOR
SITE - PRIORITY 1 LANDSCAPE - TREES
SOUTH WING TECHNOLOGY RECESSED IT STATION W/ VEINTILATED RACK & COUNTER
SITE - PRIORITY 2 LANDSCAPE - PLANTING
2
ALTERNATE SCHEDULE:
3
4
5
6
7
8
9
ISSUING OFFICE: PROJECT NO:
KEY PLAN
654321
654321
A
B
C
D
E
NO DATE DESCRIPTION
12/13/17 75% CD0
12/1
2/2
017 4
:30:1
3 P
M
COVER SHEET & INDEX
G-001
NEW RESIDENCE
HALL
75% CONSTRUCTION
DOCUMENTS
LAS CRUCES, NEW MEXICO 88003
LAS CRUCES 8919.17
NEW RESIDENCE HALLLAS CRUCES CAMPUS
NEW MEXICO STATE UNIVERSITY
RE
VIT
_v16
LAS CRUCES, NEW MEXICO 88003
THIS DOCUMENT IS RELEASED ON12-13-2017 FOR THE PURPOSE OFINTERIM REVIEW UNDER THEAUTHORITY OF KIM M HOOKER,R.A., NEW MEXICO LICENSE #2828.IT IS NOT TO BE USED FORREGULATORY APPROVAL,CONSTRUCTION, BIDDING ORPERMIT PURPOSES.PARKHILL, SMITH & COOPER, INC.
115 W. GriggsLas Cruces, New Mexico 88001
575.523.0915
PARKHILL SMITH & COOPER
A-101 FLOOR PLAN OVERALL - FIRST FLOOR
A-102 FLOOR PLAN OVERALL - SECOND FLOOR
A-103 FLOOR PLAN OVERALL - THIRD FLOOR
A-111A DIMENSIONED PLAN - BASEMENT & FIRST FLOOR - AREA A
A-111B DIMENSIONED PLAN - FIRST FLOOR - AREA B
A-112A DIMENSIONED PLAN - SECOND FLOOR - AREA A
A-112B DIMENSIONED PLAN - SECOND FLOOR - AREA B
A-113A DIMENSIONED PLAN - THIRD FLOOR - AREA A
A-113B DIMENSIONED PLAN - THIRD FLOOR - AREA B
A-121A ANNOTATED PLAN - BASEMENT & FIRST FLOOR - AREA A
A-121B ANNOTATED PLAN - FIRST FLOOR - AREA B
A-122A ANNOTATED PLAN - SECOND FLOOR - AREA A
A-122B ANNOTATED PLAN - SECOND FLOOR - AREA B
A-123A ANNOTATED PLAN - THIRD FLOOR - AREA A
A-123B ANNOTATED PLAN - THIRD FLOOR - AREA B
A-131A REFLECTED CEILING PLAN - FIRST FLOOR - AREA A
A-131AA REFLECTED CEILING PLAN - FIRST FLOOR - AREA A - ALTERNATE
A-131B REFLECTED CEILING PLAN - FIRST FLOOR - AREA B
A-131BA REFLECTED CEILING PLAN - FIRST FLOOR - AREA B - ALTERNATE
A-132A REFLECTED CEILING PLAN - SECOND FLOOR - AREA A
A-132AA REFLECTED CEILING PLAN - SECOND FLOOR - AREA A - ALTERNATE
A-132B REFLECTED CEILING PLAN - SECOND FLOOR - AREA B
A-132BA REFLECTED CEILING PLAN - SECOND FLOOR - AREA B - ALTERNATE
A-133A REFLECTED CEILING PLAN - THIRD FLOOR - AREA A
A-133AA REFLECTED CEILING PLAN - THIRD FLOOR - AREA A - ALTERNATE
A-133B REFLECTED CEILING PLAN - THIRD FLOOR - AREA B
A-133BA REFLECTED CEILING PLAN - THIRD FLOOR - AREA B - ALTERNATE
A-141 ROOF PLAN
A-201 EXTERIOR ELEVATIONS
A-202 EXTERIOR ELEVATIONS
A-203 EXTERIOR ELEVATIONS - SOUTH ENTRY FEATURES
A-212 RESIDENTIAL ROOM INTERIOR ELEVATIONS
A-213 RESIDENTIAL ROOM INTERIOR ELEVATIONS
A-301 BUILDING SECTIONS
A-302 BUILDING SECTIONS
A-303 BUILDING SECTIONS
A-312 WALL SECTIONS
A-401 ENLARGED PLANS
A-402 VERTICAL CIRCULATION SECTIONS
A-403 VERTICAL CIRCULATION SECTIONS - NORTH STAIR
A-404 VERTICAL CIRCULATION SECTIONS - ELEVATOR
A-405 MILLWORK DETAILS
A-501 DETAILS
A-503 DECORATIVE EIFS DETAILS
A-504 ROOF DETAILS
A-601 DOOR SCHEDULE - PART 1
A-602 DOOR SCHEDULE - PART 2
SET NUMBER:
FIRE PROTECTION
PLUMBING
MECHANICAL
F-001 GENERAL FIRE CONCEPT & ENLARGED FIRE SPRINKLER CONCEPT PLAN -BASEMENT MECH. ROOM
F-111 FIRE SPRINKLER CONCEPT PLAN - FIRST FLOOR
F-112 FIRE SPRINKLER CONCEPT PLAN - SECOND FLOOR
F-113 FIRE SPRINKLER CONCEPT PLAN - THIRD FLOOR
ARCHITECTURAL
ELECTRICAL
AREA MAP SITE MAP
STRUCTURALStubbs Engineering, Inc.277 E. Amador Ave., Suite 200Las Cruces, NM 88001575.993.5228
MECHANICALRBM Engineering, Inc.1065 S. Main, Building D, Suite ALas Cruces, NM 88005575.647.1554
ELECTRICALRBM Engineering, Inc.1065 S. Main, Building D, Suite ALas Cruces, NM 88005575.647.1554
SUSTAINABILITYHalcom Consulting, LLC2917 Carlisle NE, Suite 109Albuquerque, NM 87110505.872.0990
BASE BID - RESIDENTIAL BUILDING ALTERNATES
*
PROJECT LOCATION CONTRACTORLAYOUT AREA
STRUCTURAL
S-100 STRUCTURAL NOTES
S-101 WIND & SNOW DIAGRAM
S-102 STRUCTURAL DETAILS
S-200 BASEMENT FOUNDATION PLAN - NORTH AREA "A"
S-210 OVERALL FOUNDATION PLAN
S-211 FOUNDATION PLAN - WEST AREA "A"
S-212 FOUNDATION PLAN - NORTH WEST AREA "A"
S-213 FOUNDATION PLAN - NORTH AREA "A" & "B"
S-214 FOUNDATION PLAN - NORTH EAST AREA "B"
S-215 FOUNDATION PLAN - SOUTH EAST AREA "B"
S-216 FOUNDATION PLAN - SOUTH AREA "B"
S-300 OVERALL 2ND FLOOR FRAMING PLAN
S-301 2ND FLOOR FRAMING PLAN - WEST AREA "A"
S-302 2ND FLOOR FRAMING PLAN - NORTH WEST AREA "A"
S-303 2ND FLOOR FRAMING PLAN - NORTH AREA "A" & "B"
S-304 2ND FLOOR FRAMING PLAN - NORTH EAST AREA "B"
S-305 2ND FLOOR FRAMING PLAN - SOUTH EAST AREA "B"
S-306 2ND FLOOR FRAMING PLAN - SOUTH AREA "B"
S-310 OVERALL 3RD FLOOR FRAMING PLAN
S-311 3RD FLOOR FRAMING PLAN - WEST AREA "A"
S-312 3RD FLOOR FRAMING PLAN - NORTH WEST AREA "A"
S-313 3RD FLOOR FRAMING PLAN - NORTH AREA "A" & "B"
S-314 3RD FLOOR FRAMING PLAN - NORTH EAST AREA "B"
S-315 3RD FLOOR FRAMING PLAN - SOUTH EAST AREA "B"
S-400 OVERALL ROOF FRAMING PLAN
S-401 ROOF FRAMING PLAN - WEST AREA "A"
S-402 ROOF FRAMING PLAN - NORTH WEST AREA "A"
S-403 ROOF FRAMING PLAN - NORTH AREA "A" & "B"
S-404 ROOF FRAMING PLAN - NORTH EAST AREA "B"
S-405 ROOF FRAMING PLAN - EAST AREA "B" & TRUSS ELEVATION
S-406 HIGH ROOF FRAMING PLAN
S-408 ALTERNATE NORTH TOWER HIGH ROOF FRAMING PLANS
S-500 FOUNDATION DETAILS
S-600 TYPICAL FRAMING DETAILS
S-601 FLOOR FRAMING DETAILS
S-700 ROOF FRAMING DETAILS
S-800 STAIR PLANS
G-001 COVER SHEET & INDEX
G-002 SYMBOLS, LEGENDS & ABBREVIATIONS
G-003 ACCESSIBILITY STANDARDS
G-004 ACCESSIBILITY STANDARDS
G-005 CODE INFORMATION - 1ST FLR CODE PLAN
G-006 2ND-3RD FLR CODE PLAN
SHEET INDEX
GENERAL
LANDSCAPE
CIVIL
I-001 FINISH LEGEND & FINISH ABBREVIATIONS
I-111A FIRST FLOOR - FINISH FLOOR PLAN AREA A
I-111B FIRST FLOOR - FINISH FLOOR PLAN AREA B
I-112A SECOND FLOOR - FINISH FLOOR PLAN AREA A
I-112B SECOND FLOOR - FINISH FLOOR PLAN AREA B
I-113A THIRD FLOOR - FINISH FLOOR PLAN AREA A
I-113B THIRD FLOOR - FINISH FLOOR PLAN AREA B
I-121A FIRST FLOOR - FINISH WALL PLAN AREA A
I-121B FIRST FLOOR - FINISH WALL PLAN AREA B
I-122A SECOND FLOOR - FINISH WALL PLAN AREA A
I-122B SECOND FLOOR - FINISH WALL PLAN AREA B
I-123A THIRD FLOOR - FINISH WALL PLAN AREA A
I-123B THIRD FLOOR - FINISH WALL PLAN AREA B
I-131A FIRST FLOOR - FURNITURE PLAN AREA A
I-131B FIRST FLOOR - FURNITURE PLAN AREA B
I-132 SECOND FLOOR - FURNITURE PLAN
I-133 THIRD FLOOR - FURNITURE PLAN
INTERIOR
PROJECT LOCATION
E-001 ELECTRICAL SYMBOL LEGEND
E-002 ELECTRICAL GENERAL NOTES
E-100 ELECTRICAL DEMOLITION AND NEW WORK SITE PLAN
E-101 ELECTRICAL NEW WORK SITE PLAN
E-111A ELECTRICAL LIGHTING PLAN - BASEMENT & FIRST FLOOR - AREA A (SCALE 1/8")
E-111AE ELECTRICAL EXIT/EMERGENCY LIGHTING PLAN - BASEMENT & FIRST FLOOR -AREA A (SCALE 1/8")
E-111B ELECTRICAL LIGHTING PLAN - FIRST FLOOR - AREA B (SCALE 1/8")
E-111BE ELECTRICAL EXIT/EMERGENCY LIGHTING PLAN - FIRST FLOOR - AREA B (SCALE1/8")
E-112A ELECTRICAL LIGHTING PLAN - SECOND FLOOR - AREA A (SCALE 1/8")
E-112AE ELECTRICAL EXIT/EMERGENCY LIGHTING PLAN - SECOND FLOOR - AREA A (SCALE1/8")
E-112B ELECTRICAL LIGHTING PLAN - SECOND FLOOR - AREA B (SCALE 1/8")
E-112BE ELECTRICAL EXIT/EMERGENCY LIGHTING PLAN - SECOND FLOOR - AREA B (SCALE1/8")
E-113A ELECTRICAL LIGHTING PLAN - THIRD FLOOR - AREA A (SCALE 1/8")
E-113AE ELECTRICAL EXIT/EMERGENCY LIGHTING PLAN - THIRD FLOOR - AREA A (SCALE1/8")
E-113B ELECTRICAL LIGHTING PLAN - THIRD FLOOR - AREA B (SCALE 1/8")
E-113BE ELECTRICAL EXIT/EMERGENCY LIGHTING PLAN - THIRD FLOOR - AREA B (SCALE1/8")
E-121A ELECTRICAL POWER PLAN - BASEMENT & FIRST FLOOR - AREA A (SCALE 1/8")
E-121B ELECTRICAL POWER PLAN - FIRST FLOOR - AREA B (SCALE 1/8")
E-122A ELECTRICAL POWER PLAN - SECOND FLOOR - AREA A (SCALE 1/8")
E-122B ELECTRICAL POWER PLAN - SECOND FLOOR - AREA B (SCALE 1/8")
E-123A ELECTRICAL POWER PLAN - THIRD FLOOR - AREA A (SCALE 1/8")
E-123B ELECTRICAL POWER PLAN - THIRD FLOOR - AREA B (SCALE 1/8")
E-131A ELECTRICAL HVAC POWER PLAN - BASEMENT & FIRST FLOOR - AREA A (SCALE1/8")
E-131B ELECTRICAL HVAC POWER PLAN - FIRST FLOOR - AREA B (SCALE 1/8")
E-132A ELECTRICAL HVAC POWER PLAN - SECOND FLOOR - AREA A (SCALE 1/8")
E-132B ELECTRICAL HVAC POWER PLAN - SECOND FLOOR - AREA B (SCALE 1/8")
E-133A ELECTRICAL HVAC POWER PLAN - THIRD FLOOR - AREA A (SCALE 1/8")
E-133B ELECTRICAL HVAC POWER PLAN - THIRD FLOOR - AREA B (SCALE 1/8")
E-141A ELECTRICAL SPECIAL SYSTEMS PLAN - BASEMENT & FIRST FLOOR - AREA A(SCALE 1/8")
E-141B ELECTRICAL SPECIAL SYSTEMS PLAN - FIRST FLOOR - AREA B (SCALE 1/8")
E-142A ELECTRICAL SPECIAL SYSTEMS PLAN - SECOND FLOOR - AREA A (SCALE 1/8")
E-142B ELECTRICAL SPECIAL SYSTEMS PLAN - SECOND FLOOR - AREA B (SCALE 1/8")
E-143A ELECTRICAL SPECIAL SYSTEMS PLAN - THIRD FLOOR - AREA A (SCALE 1/8")
E-143B ELECTRICAL SPECIAL SYSTEMS PLAN - THIRD FLOOR - AREA B (SCALE 1/8")
E-151A ELECTRICAL FIRE ALARM SYSTEMS PLAN - BASEMENT & FIRST FLOOR - AREA A(SCALE 1/8")
E-151B ELECTRICAL FIRE ALARM SYSTEMS PLAN - FIRST FLOOR - AREA B (SCALE 1/8")
E-152A ELECTRICAL FIRE ALARM SYSTEMS PLAN - SECOND FLOOR - AREA A (SCALE 1/8")
E-152B ELECTRICAL FIRE ALARM SYSTEMS PLAN - SECOND FLOOR - AREA B (SCALE 1/8")
E-153A ELECTRICAL FIRE ALARM SYSTEMS PLAN - THIRD FLOOR - AREA A (SCALE 1/8")
E-153B ELECTRICAL FIRE ALARM SYSTEMS PLAN - THIRD FLOOR - AREA B (SCALE 1/8")
E-401 ELECTRICAL ENLARGED LIGHTING PLANS
E-402 ELECTRICAL ENLARGED POWER & SPECIAL SYSTEMS
E-501 ELECTRICAL DETAILS
E-601 ELECTRICAL RISER DIAGRAMS
E-602 ELECTRICAL PANEL SCHEDULES
E-603 ELECTRICAL SCHEDULES
L-101 LANDSCAPE SITE PLAN
L-101A LANDSCAPE SITE PLAN ALTERNATE
L-103 LANDSCAPE PLANTING PLAN
L-103A LANDSCAPE PLANTING PLAN ALTERNATE
L-501 LANDSCAPE DETAILS
L-502 LANDSCAPE DETAILS
C-100 CIVIL SITE DEMOLITION PLAN
C-101 CIVIL SITE PLAN
C-102 CIVIL GRADING PLAN
C-103A DRAINAGE PLAN
C-103B STORM SEWER PLAN
C-200 EROSION CONTROL PLAN
C-201 EROSION CONTROL DETAILS
C-501 SITE DETAILS
C-502 UTILITY DETAILS
M-001 HVAC GENERAL NOTES AND LEGEND
M-111 HVAC PLAN - FIRST FLOOR & HVAC SITE
M-111A PARTIAL HVAC PLAN - FIRST FLOOR - AREA A
M-111B PARTIAL HVAC PLAN - FIRST FLOOR - AREA B
M-112 HVAC PLAN - SECOND FLOOR
M-112A PARTIAL HVAC PLAN - SECOND FLOOR - AREA A
M-112B PARTIAL HVAC PLAN - SECOND FLOOR - AREA B
M-113 HVAC PLAN - THIRD FLOOR
M-113A PARTIAL HVAC PLAN - THIRD FLOOR - AREA A
M-113B PARTIAL HVAC PLAN - THIRD FLOOR - AREA B
M-114 HVAC PLAN - ROOF
M-211 HVAC PIPING PLAN - FIRST FLOOR
M-212 HVAC PIPING PLAN - SECOND FLOOR
M-213 HVAC PIPING PLAN - THIRD FLOOR
M-311 ENLARGED HVAC PLANS - FIRST FLOOR
M-312 ENLARGED HVAC PLANS - SECOND FLOOR
M-313 ENLARGED HVAC PLANS - THIRD FLOOR & BASEMENT MECH. ROOM
M-401 MECHANICAL CONTROL DIAGRAM SCHEMATICS
M-402 MECHANICAL CONTROL DIAGRAM SCHEMATICS
M-403 MECHANICAL CONTROL DIAGRAM SCHEMATICS
M-501 MECHANICAL SCHEMATICS
M-502 MECHANICAL SCHEMATICS
M-601 MECHANICAL SCHEDULES
P-001 PLUMBING GENERAL NOTES & LEGEND
P-111 PLUMBING PLAN - FIRST FLOOR
P-111A PARTIAL PLUMBING PLAN - FIRST FLOOR - AREA A
P-111B PARTIAL PLUMBING PLAN - FIRST FLOOR - AREA B
P-112 PLUMBING PLAN - SECOND FLOOR
P-112A PARTIAL PLUMBING PLAN - SECOND FLOOR - AREA A
P-112B PARTIAL PLUMBING PLAN - SECOND FLOOR - AREA B
P-113 PLUMBING PLAN - THIRD FLOOR
P-113A PARTIAL PLUMBING PLAN - THIRD FLOOR - AREA A
P-113B PARTIAL PLUMBING PLAN - THIRD FLOOR - AREA B
P-114 PLUMBING PLAN - ROOF
P-311 ENLARGED PLUMBING PLANS - FIRST FLOOR
P-312 ENLARGED PLUMBING PLANS - SECOND FLOOR
P-313 ENLARGED PLUMBING PLANS - THIRD FLOOR & BASEMENT MECH. ROOM
P-501 PLUMBING SCHEMATICS
P-502 PLUMBING SCHEMATICS
P-503 PLUMBING SCHEMATICS
P-601 PLUMBING SCHEDULES
405 - 455
16" - 18"
CL
405 - 455
16" - 18"
CL
1420
58 M
IN
1220
48 MIN
WC @ TYPE B UNIT1525
60 MIN
1420
56 M
IN
WC @ RES APT
CL
(36")
3' - 0"
(66" )
5' -
6"
> 2
4"
EQ EQ
1
NOTES1. FINISH WALLS UNDER COUNTER2. FLOORING CONTINUOUS UNDER COUNTER3. SEE MILLWORK FOR REMOVABLE CABINET UNDER COUNTER4. SEE MILLWORK & PLUMBING FOR LAVATORY
[REF: ANSI A117.1, 1004.11.3.1.1, EXCEPTION a) & b)]
2
3 4
LAV CLEARANCE @ TYPE B UNITKITCHEN WORK AREA
NOTES1. ADJACENT COUNTER ON CABINETS @ 36" AFF2. ACCESSIBLE WORK AREA @ 34" AFF3. CLEAR FLOOR SPACE REQUIRED WITH FRONT APPROACH4. OPEN COUNTER W/ KNEE SPACE/ SEE MILLWORK
[REF: ANSI A117.1, 1004.11.3.1.1, EXCEPTION a) & b)]
2' - 0"
2' -
8"
1
2
4
3
ISSUING OFFICE: PROJECT NO:
KEY PLAN
654321
654321
A
B
C
D
E
NO DATE DESCRIPTION
12/13/17 75% CD0
12/1
2/2
017 2
:57:1
6 P
M
SYMBOLS, LEGENDS &
ABBREVIATIONS
G-002
NEW RESIDENCE
HALL
75% CONSTRUCTION
DOCUMENTS
LAS CRUCES, NEW MEXICO 88003
LAS CRUCES 8919.17
RE
VIT
_v16
THIS DOCUMENT IS RELEASED ON12-13-2017 FOR THE PURPOSE OFINTERIM REVIEW UNDER THEAUTHORITY OF KIM M HOOKER,R.A., NEW MEXICO LICENSE #2828.IT IS NOT TO BE USED FORREGULATORY APPROVAL,CONSTRUCTION, BIDDING ORPERMIT PURPOSES.PARKHILL, SMITH & COOPER, INC.
GENERAL DRAWING LEGEND FLOOR PLAN LEGENDSITE PLAN LEGEND ROOF PLAN LEGEND RCP LEGEND DETAIL LEGEND
F
E
D
C
B
A
ABBREVIATIONS
G
H
J
I
AANNN
SHEET IDENTIFICATION FORMAT
SHEET TYPE DESIGNATORS
0 GENERAL (COVER SHEETS, INDEX, SYMBOLS LEGEND, NOTES, ETC.)1 PLANS (HORIZONTAL VIEWS)2 ELEVATIONS (VERTICAL VIEWS)3 SECTIONS (SECTIONAL VIEWS)4 LARGE SCALE VIEWS (ENLARGED PLANS, ELEVATIONS, OR SECTIONS THAT
ARE NOT DETAILS)5 DETAILS6 SCHEDULES AND DIAGRAMS7 USER DEFINED (FOR TYPES THAT DO NOT FALL IN OTHER CATEGORIES)8 USER DEFINED (FOR TYPES THAT DO NOT FALL IN OTHER CATEGORIES)9 3D REPRESENTATIONS (ISOMETRICS, PERSPECTIVES, PHOTOGRAPHS)
DISCIPLINEDESIGNATOR
SHEET TYPEDESIGNATOR(SEE BELOW)
SHEET SEQUENCENUMBER
ACCABACIADADAADDLADJADDMAFFAHUAIAAISCALTALUMANODANSIAPAAPPROXARCHASCEASTMAUTOAVGAWGAWSA/C
ACCESSIBLEANCHOR BOLTAMERICAN CONCRETE INSTITUTEAREA DRAINAMERICANS WITH DISABILITIES ACTADDITIONALADJUSTABLEADDENDUMABOVE FINISH FLOORAIR HANDLING UNITAMERICAN INSTITUTE OF ARCHITECTSAMERICAN INSTITUTE OF STEEL CONSTRUCTIONALTERNATEALUMINUMANODIZEDAMERICAN NATIONAL STANDARDS INSTITUTEAMERICAN PLYWOOD ASSOCIATIONAPPROXIMATEARCHITECTAMERICAN SOCIETY OF CIVIL ENGINEERSAMERICAN SOCIETY OF TESTING MATERIALSAUTOMATICAVERAGEAMERICAN WIRE GAGEAMERICAN WELDING SOCIETYAIR CONDITIONING
BALBCBIABITUMBLBLDGBMBOCA
BOXBOTB PLBRDGBRGBTWNBUR
BALANCEBACK OF CURBBRICK INSTITUTE OF AMERICABITUMINOUSBUILDING LINEBUILDINGBENCH MARKBUILDING OFFICIALS AND CODE ADMINISTRATORSINTERNATIONAL, INCBOTTOM OF STEELBOTTOM (BOTTOM FACE, LAYER, SIDE)BASE PLATEBRIDGINGBEARINGBETWEENBUILT-UP ROOFING
CCU FTCF/CICF/OICGCICIRCIRCCJCLCLGCLRcmCMUCOLCONCCONNCONSTRCONTCONTRCRCMFCSKCSICTRCU YD
AMERICAN STANDARD CHANNEL (STRUCTURAL SHAPE)CUBIC FOOTCONTRACTOR FURNISHED/CONTRACTOR INSTALLEDCONTRACTOR FURNISHED/OWNER INSTALLEDCORNER GUARDCAST IRONCIRCLECIRCULARCONTROL JOINTCENTER LINECEILINGCLEARCENTIMETERCONCRETE MASONRY UNITCOLUMNCONCRETECONNECTCONSTRUCTIONCONTINUECONTRACTORCIRCUMFERENCECOUNTER SUNKCONSTRUCTION SPECIFICATIONS INSTITUTECENTERCUBIC YARD
DDATDBLDDSDEGDEMODETDFDIADIAGDIMDIVDLDSDWG
DEPTHDATUMDOUBLEDOUBLE DISPLAY STRIPDEGREEDEMOLISHDETAILDRINKING FOUNTAINDIAMETERDIAGONALDIMENSIONDIVIDEDEAD LOADDOWNSPOUTDRAWING
EEAEFEIFSEJELELECELEVENGREQEQUIPEWEWCEXISTEXPEXP BTEXT
EAST, MODULUS OF ELASTICITYEACHEACH FACE, EXTERIOR FINISHEXTERIOR INSULATION FINISH SYSTEMEXPANSION JOINTELEVATIONELECTRIC, ELECTRICALELEVATORENGINEEREQUALEQUIPMENTEACH WAYELECTRIC WATER COOLEREXISTINGEXPANSIONEXPANSION BOLTEXTERIOR
FDFDTNFEBFECFF ELFIN FLRFINFOCFOFFOMFOSFOWFSFTFTGFURG
FLOOR DRAINFOUNDATIONFIRE EXTINGUISHER & BRACKETFIRE EXTINGUISHER & CABINETFINISH FLOOR ELEVATIONFINISH FLOORFINISH(ED)FACE OF CONCRETE, FACE OF CURBFACE OF FINISHFACE OF MASONRYFACE OF STUDFACE OF WALLFAR SIDE (FACE, LAYER)FOOTFOOTINGFURRING
GAGALVGCGFCIGOVTGYP BDGYP
GAGEGALVANIZEDGENERAL CONTRACTORGROUND FAULT CIRCUIT INTERRUPTERGOVERNMENTGYPSUM BOARDGYPSUM
HDBDHDWDHDWHEXHMHORIZHPHSHTHVAC
HARDBOARDHARDWOODHARDWAREHEXAGON(AL)HOLLOW METALHORIZONTALHEAT PUMPHIGH STRENGTHHEIGHTHEATING VENTILATION AND AIR CONDITIONING
IIBCIDIFINCLINSINTINV
MOMENT OF INERTIAINTERNATIONAL BUILDING CODEINSIDE DIAMETERINSIDE FACEINCLUDE(D)(ING)(SIVE)INSULATIONINTERIORINVERT(ED)
JAN JANITOR
LlLLBLHLLLLHLLVLTLT WT
LITERANGLE (STRUCTURAL SHAPE)POUNDLEFT HANDLIVE LOADLONG LEG HORIZONTALLONG LEG VERTICALLIGHTLIGHT WEIGHT
MMAUmMATLMAXMBMCJMECHMFGMFRMIL STDMINMISCmmMOMODMTMTLMLWK
MAKE UP AIR UNIT(S)METER(S)MATERIALMAXIMUMMACHINE BOLTMASONRY CONTROL JOINTMECHANIC(AL)MANUFACTURINGMANUFACTURERMILITARY STANDARDMINIMUMMISCELLANEOUSMILLIMETERMASONRY OPENINGMODIFYMETAL THRESHOLDMETALMILLWORK
NNNANATNBSNFPANICNOMNRCNSNTS
NORTHNOT APPLICABLENATURALNATIONAL BUREAU OF STANDARDSNATIONAL FIRE PROTECTION ASSOCIATIONNOT IN CONTRACTNOMINALNOISE REDUCTION COEFFICIENTNEAR SIDE (FACE)NOT TO SCALE
OOCODOFOFDOF/CIOF/OIOH DROPNGOPHOSHAOz
ON CENTEROUTSIDE DIAMETEROUTSIDE FACEOVER FLOW DRAINOWNER FURNISHED/CONTRACTOR INSTALLEDOWNER FURNISHED/OWNER INSTALLEDOVERHEAD DOOROPENINGOPPOSITE HANDOCCUPATIONAL SAFETY AND HEALTH ADMINISTRATIONOUNCE
PPARPCAPCFPCIPERFPERPPLPLAMPLFPRPREFABPREFINPRELIMPROJPSFPSIPBDPTDPTDWRPVCPLYWDPVG
PARALLELPORTLAND CEMENT ASSOCIATIONPOUNDS PER CUBIC FOOTPRESTRESSED CONCRETE INSTITUTEPERFORATE(D)PERPENDICULARPROPERTY LINEPLASTIC LAMINATEPOUNDS PER LINEAL FOOTPAIRPREFABRICATEPREFINISHPRELIMINARYPROJECTPOUNDS PER SQUARE FOOTPOUNDS PER SQUARE INCHPARTICLE BOARDPAPER TOWEL DISPENSERPAPER TOWEL DISPENSER & WASTE RECEPTACLEPOLYVINYL CHLORIDEPLYWOODPAVING
QQCQTY
QUALITY CONTROLQUANTITY
RRRCPRDREFREFLREINFREQDREVRHROROWRTU
RADIUSREFLECTED CEILING PLANROOF DRAINREFERENCEREFLECTREINFORCEREQUIREDREVISIONRIGHT HAND(ED)ROUGH OPENINGRIGHT OF WAYROOF TOP UNIT
SSSBCCISCHEDSDSDISECTSHTSIMSJISPECSPSSTSTDSTLSTRUCTSUSPSYMM
SOUTHSOUTHERN BUILDING CODE CONGRESS INTERNATIONALSCHEDULESOAP DISPENSERSTEEL DOOR INSTITUTESECTIONSHEETSIMILARSTEEL JOIST INSTITUTESPECIFICATIONSOLID PLASTICSTAINLESS STEELSTANDARDSTEELSTRUCTURALSUSPENDEDSYMMETRICAL
TTHDTANTEMPTFFTHKTLTTMHTOBTOCTOFTOGTOJTOLTOMTOSTOWTTDTRANSTRTDTSTYPT&G
TREADTANGENTTEMPORARYTOP OF FINISH FLOORTHICKNESSTOILETTOP OF MANHOLETOP OF BEAMTOP OF CURBTOP OF FOOTINGTOP OF GRADETOP OF JOISTTOLLERANCETOP OF MASONRYTOP OF STEELTOP OF WALLTOILET TISSUE DISPENSERTRANSPARENTTREATEDTUBE STEELTYPICALTONGUE AND GROOVE
UUBCULULTUNOUON
UNIFORM BUILDING CODEUNDERWRITERS LABORATORIES, INCULTIMATEUNLESS NOTED OTHERWISEUNLESS OTHERWISE NOTED
VVARVERT
VARIESVERTICAL
WWWLDWPWWFW/W/OW/W
WESTWELDEDWORK POINTWELDED WIRE FABRICWITHWITHOUTWALL TO WALL
XXFMR TRANSFORMER
CL
HM00
10
0
00
00
LV00
00
AL00
00
000
0000
ROOM NAME
A A
TITLE1/8" = 1'-0"
CENTER LINE
BREAK LINE
SECTION CUTASSOCIATED W/ SAMESHEET OR DETAIL
DATUM ELEVATION(NEW)
DATUM ELEVATION(EXISTING)
STRUCTURAL COLUMNLINE
REVISION
DRAWING TITLE
ELEVATION MARK
SECTION MARK
PLAN DETAIL MARK
PARTITION TYPE
KEY DEMOLITIONNOTE
KEY NOTE
ALUMINUM FRAMEMARK
HOLLOW METALFRAME MARK
LOUVER MARK
FURNISHINGS/EQUIPMENT
WINDOW MARK
DOOR NUMBER
ROOM NAMEROOM NUMBER
NEW DOOR
PLAN NORTH ARROW
NORTH ARROW
EXISTING DOOR
REFERENCE NUMBER
XX/XXXX
NORTH
A1
#
/
XX/XXXX
XXXX
XX
PROPERTY LINE
MATCH/DIVIDE LINE
NORTH ARROWFOR SITE PLANSN
TRUE NORTH
SHEET NUMBER WHERE REFERENCED
PLAN NORTH
X X
A
WP
99.6
x 31
9.60
320.10 TC319.60 G
319.60
+TC
+G
+FL
PROPERTY LINE
EXISTING CONSTRUCTIONTO REMAIN
EXISTING CONSTRUCTIONTO BE REMOVED
NEW ASPHALT PAVING
NEW CONCRETEWALK/PAVING
NEW CONTROL JOINT
NEW EXPANSION JOINT
NEW CONTOUR LINES
EXISTING CONTOUR LINESTO REMAIN
FENCE
NEW SPOT ELEVATION
EXISTING SPOT ELEVATION
TOP OF CURB
GUTTER
FLOW LINE
WORKING POINT
ACCESSIBLE PARKING SIGN
PARKING SIGN
LIGHT POLE
TREE
SLOPE
99.6
FEC
FEB
DS
FD
MCJ
CONCRETE WALL
FACE BRICK
CMU WALL
EXISTING CONSTRUCTIONTO REMAIN
EXISTING CONSTRUCTIONTO BE REMOVED
NEW METAL STUD WALLS
NEW PARTIAL HEIGHT WALLS
GLAZING SYSTEM
WIRE MESH OR FABRICPARTITION
CORNER GUARD
END WALL GUARD
WALL GUARD
HANDRAIL
FIRE EXTINGUISHER ANDCABINET
FIRE EXTINGUISHER ANDBRACKET
FURNITURE/EQUIPMENT NIC
MASONRY CONTROL JOINT
DOWN SPOUT
FLOOR DRAIN
RD
OD
ROOF DRAIN
OVERFLOW DRAIN
SLOPE
MECHANICAL EQUIPMENT
VENT THROUGH ROOF (VTR)
SKYLIGHT
ROOF HATCH
CJ
S
SD
GYP BD CEILING
SUSPENDED METAL LATHAND PLASTER CEILING
LAY-IN CEILING PANEL
LAY-IN CEILING PANEL
SUPPLY AIR GRILLE
RETURN AIR OREXHAUST GRILLE
EXIT LIGHTS
LIGHT FIXTURES
SKYLIGHT
CEILING TRACK
CONTROL JOINT
SPEAKER
ACCESS PANEL
SMOKE DETECTOR
COMPACTED SOIL
UNDISTURBED SOIL
STONE/MARBLE
PLASTER OR STUCCOON METAL LATH
STEEL
CONCRETE IN SECTION
BRICK
CMU
BATT INSULATION
ACOUSTICAL TILE
RIGID INSULATION
WOOD DISCONTINUOUS
WOOD CONTINUOUS
PLASTER, SAND ORCEMENT GROUT
POUROUS FILL, GRAVEL(CAPILLARY WATERBARRIER PAVEMENT BASE)
TERRAZZO (IN SECTION)
ACCESSIBLITY GUIDELINE SHEETS ARE BASED ON CHAPTER 11,ACCESSIBILTY OF THE NEW MEXICO BUILDING CODE, AND SUPERCEDECHAPTER 11 ACCESSIBILITY OF THE INTERNATIONAL BUILDING CODE. THEADOPTED STANDARD OF QUALITY FOR ACCESSIBLE DESIGN IS THEICC/ANSI A117.1-2009 "ACCESSIBLE AND USABLE BUILDINGS ANDFACILITIES.'ACCESSIBILITY GUIDELINE SHEETS ARE FOR INFORMATIONAL PURPOSESONLY AND INTENDED TO SERVE AS A GUIDE FOR CONSTRUCTIONPROFESSIONALS AND OWNERS.SOME OF THE INFORMATION AND PICTOGRPAHS SHOWN MAY NOT BEAPPLICABLE TO THIS PROJECT.REFER TO PLUMBING SHEETS FOR PLUMBING FIXTURE MOUNTINGHEIGHTS.GRAPHICS SHOWN ARE FOR ADULTSSEE SHEET G-003 & G-004 ACCESSIBILITY GUIDELINE SHEETS.
GENERAL NOTES
SUPPLEMENTARY ACCESSIBILITY NOTES
ACCESSIBLITY GUIDELINE SHEETS (SEE G-003 & G-004) ARE BASED ONCHAPTER 11, ACCESSIBILTY OF THE NEW MEXICO BUILDING CODE, ANDSUPERCEDE CHAPTER 11 ACCESSIBILITY OF THE INTERNATIONAL BUILDINGCODE. THE ADOPTED STANDARD OF QUALITY FOR ACCESSIBLE DESIGN ISTHE ICC/ANSI A117.1-2009 "ACCESSIBLE AND USABLE BUILDINGS ANDFACILITIES.'ACCESSIBILITY GUIDELINE SHEETS ARE FOR INFORMATIONAL PURPOSESONLY AND INTENDED TO SERVE AS A GUIDE FOR CONSTRUCTIONPROFESSIONALS AND OWNERS.ADDITIONAL INFORMATION SHOWN ON THIS SHEET ARE SPECIFIC TO THETYPE B HOUSING UNIT REQUIREMENTS [CH. 10 DWELLING & SLEEPINGUNITS, ICC/ANSI A117.1-2009, AS REF BY IBC CH. 11].WATER CLOSETS AT "TYPE B" UNITS SHALL HAVE THE FOLLOWINGCLEARANCE:A) THE CENTERLINE OF THE WATER CLOSET SHALL BE 16 INCHES MINIMUMAND 18 INCHES MAXIMUM FROM ONE SID EOF THE REQUIRED CLEARANCE.B)CLEARANCE AROUND THE WATER CLOSET SHALL BE 48 INCHES MINIMUMIN WIDTH, MEASURED PERPENDICULAR FROM THE SIDE OF THECLEARANCE THAT IS 16 INCHES MINIMUM AND 18 INCHES MAXIMUM FROMTHE WATER CLOSET CENTERLINE.C) CLEARANCE AROUND THE WATER CLOSET SHALL BE 56 INCHESMINIMUM IN DEPTH, MEASURED PERPENDICULAR FROM THE REAR WALL.SEE C1, D1 & E1/G-005 FOR ACCESSIBILITY FEATURES.GRAPHICS SHOWN ARE FOR ADULTS.SEE SHEET G-003 FOR SHOWER & TUB REQUIREMENTS.SEE SHEET G-OO3 "TYPICAL DOOR CLEARANCES" FOR PRIMARYENTRANCE DOOR TO ROOMS.USER PASSAGE DOORWAYS WITHIN RESIDENTIAL SUITES SHALL HAVE AMINIMUM CLEAR OPENING OF 31 3/4".SEE SHEET G-003 "MOUNTING HEIGHTS" FOR ACCESS TO LAUNDRYEQUIPMENT.REINFORCEMENT SHALL BE PROVIDED FOR THE FUTURE INSTALLATION OFGRAB BARS AND SHOWER SEATS AT WATER CLOSETS, BATHTUBS, ANDSHOWER COMPARTMENTS. SEE SHEET G-003 "SHOWERS" & "WATERCLOSETS" FOR LOCATIONS OF REINFORCEMENT.CLEAR FLOOR SPACE PROVIDED FOR LAVATORY AT "TYPE B" RESIDENTIALSUITES TO COMPLY WITH [REF1004.11.3.1.1, EXCEPTION] 30" W X 48" DEEPFORWARD APPROACH WITH THE FOLLOWING CRITERIA: A) CABINETRY CANBE REMOVED WITHOUT REMOVAL OF LAVATORY; AND B) FLOOR FINISHEXTENDS UNDER CABINETRY, AND C) WALLS BEHIND AND SURROUNDINGTHE CABINETRY ARE FINISHED.KITCHENS: CLEAR FLOOR SPACE FOR PARALLEL APPROACH ATAPPLIANCES AS FOLLOWS:A) SINK - 30"X48", CENTERED ON THE SINK BOWL.B) DISHWASHER - 30"X48". THE DISHWASHER IN THE OPEN POSITION SHALLNOT OBSTRUCT THE CLEAR FLOOR SPACE FOR THE DISHWASHER.C) COOKTOP - 30"X48". THE CLEAR FLOOR SPACE FOR COOKTOP SHALLBE CENTERED ON THE APPLIANCE.D) OVEN - 30"X48". THE OVEN DOOR IN THE OPEN POSITION SHALL NOTOBSTRUCT THE CLEAR FLOOR SPACE FOR THE OVEN.E) REFRIGERATOR/FREEZER - 30"X48". THE CENTERLINE OF THE CLEARFLOOR SPACE SHALL BE OFFSET 24 INCHES MAXIMUM FROM THECENTERLINE OF THE APPLIANCE.SEE G-005 FOR QTY & LOCATION OF ROOMS WITH ACCESSIBLECOMMUNICATION FEATURES. SEE ELECTRICAL FOR DETAILEDCOMPONENTS.
1.
2.
3.
4.
5.6.7.
8.
9.
10.
11.
12.
ISSUING OFFICE: PROJECT NO:
KEY PLAN
654321
654321
A
B
C
D
E
NO DATE DESCRIPTION
12/13/17 75% CD0
12/1
2/2
017 2
:57:1
7 P
M
ACCESSIBILITY
STANDARDS
G-003
NEW RESIDENCE
HALL
75% CONSTRUCTION
DOCUMENTS
LAS CRUCES, NEW MEXICO 88003
LAS CRUCES 8919.17
RE
VIT
_v16
THIS DOCUMENT IS RELEASED ON12-13-2017 FOR THE PURPOSE OFINTERIM REVIEW UNDER THEAUTHORITY OF KIM M HOOKER,R.A., NEW MEXICO LICENSE #2828.IT IS NOT TO BE USED FORREGULATORY APPROVAL,CONSTRUCTION, BIDDING ORPERMIT PURPOSES.PARKHILL, SMITH & COOPER, INC.
CL CL CL CL CL CL
CL
CL CL
CL
CL
CHILDREN'S MOUNTING
HEIGHTS & REACH RANGES
REACH RANGES
RAMPS AND STAIRS
WATER CLOSETS
READING AND STUDY AREAS, AND
FIXED OR BUILT-IN SEATING AND TABLES,
WORK STATIONS
ACCESSIBILITY GUIDELINE SHEETS ARE BASED ON
THE 2012 TEXAS ACCESSIBILITY STANDARDS (TAS).
ACCESSIBILITY GUIDELINE SHEETS ARE FOR
INFORMATIONAL PURPOSES ONLY. AND INTENDED
TO SERVE AS A GUIDE FOR CONSTRUCTION
PROFESSIONALS AND OWNERS.
SOME OF THE INFORMATION AND PICTOGRAPHS
SHOWN MAY NOT BE APPLICABLE TO THIS PROJECT.
REFER TO PLUMBING SHEETS FOR PLUMBING
FIXTURE MOUNTING HEIGHTS.
GRAPHICS SHOWN ARE FOR ADULTS.
ROOM100
60" MIN
60 M
IN
30
MIN
24
MIN
12MIN
30MIN
12MIN
60 MIN
48 MIN
30
MIN 48 M
IN
30 MIN
30 M
IN
48 MIN
36 MIN
X >
24
60 MIN
X >
15
30 M
IN
6 MAX17-25
8 MIN
9"
MIN
11 MIN
27 M
IN
4 MAX
X ≥
80
X >
27
X <
80"
27"
MA
X
48 M
AX
15
MIN
20MAX
48 M
AX
44 M
AX
2O-25MAX
10 MAX
48 M
AX
15
MIN
34 M
AX
10 MAX
48 M
AX
34 M
AX
>10-24MAX
46 M
AX
24MAX 48 MIN
24MAX
32 M
IN
36 M
IN
32 M
IN
36 M
IN
Y48 M
IN
X42 MIN
X42 MIN
X<48
5 M
AX
15 M
IN
30 M
IN
30 M
IN
12 MIN
CO
NT
RO
LE
ND
WA
LL
24 M
IN
12 MAX 24 MAX24 MIN
12 M
IN
24 M
IN
12 MAX 15 MAX
12 MAX 15 MAX12 MAX 24 MAX24 MIN 36
36
36 M
IN
48 MIN 60 MIN
30 M
IN30 M
IN
36
36 MIN
60 MIN60 MIN
30 M
IN30 M
IN
6 M
AX
6 MAX6 MAX
6 M
AX
6 MAX 6 MAX
6 M
AX
6 M
AX
6 MAX
38 M
IN
48 M
AX
15 MAX
48 M
AX
27 MAX
48 M
AX
8-1
0
17-1
9
8-1
0
17-1
9
17-1
9
48 M
IN
33 MIN 33 MIN
60 M
IN
33 MIN 33 MIN
30 M
IN
24 M
IN
56 M
IN
59 M
IN
60 MIN60 MIN
4 MAX
42 M
IN
6 M
IN
6 MIN
42 M
IN
60 M
IN
35-37
ANY AMOUNT
X ≥
80
X <
27
36 MIN
33-3
6
15 MIN
48
48
36 M
AX
9
60 M
AX
15 M
IN
80-9
6
48 M
AX
2 FROM
DOOR FRAME
48 M
AX
48 M
AX
6
17 MIN
36 M
AX
28-3
4
38 M
AX
2 M
AX
48 M
IN
18 MIN
60 M
IN
X
Y
42 M
IN
X
Y
Y
42 M
IN
22 MIN
Y
48 M
IN
24 MIN 24 MIN
48 MIN
48 M
IN
32 MINCLEAR
43 M
AX
OR
66 M
IN
34-4
8
MA
X
60 M
IN
18 MIN
X>
8
48 M
IN
12 MIN
X>
8
48 M
IN
48 M
AX
27 MAX
17-19 16-18 16-18 16-18 16-18
60 MIN
16-18
56 M
IN
12
MIN
24 MIN
15 MIN
36
TO
SH
OU
LD
ER
36
TO
SH
OU
LD
ER
33-3
6
15-3
6
6 M
IN
6 M
IN
6 M
IN
6 M
IN
6 M
IN
6 M
IN
48 M
IN
60 M
AX
60 M
AX
48 M
IN
6 M
IN
60 M
AX
48 M
IN
60 M
AX
48 M
IN
CL
36 MAX
12
MAX
54 MIN
42 MIN
33-3
6
TO
P O
F G
RIP
PIN
GS
UR
FA
CE
7-9
48 M
AX
15 M
IN
48 M
IN
15
MIN
30
MIN
X
36
MINIF X>24
15
MIN
36
MINIF X>24
X
36
MINIF X>24
X
36 MIN
30
IF X ≤ 24
X
15
MIN
24 MIN
9"
MIN
15
MIN
1/4
1
2
1/2
FORWARD PARALLEL ELEVATION
TOE CLEARANCE
PLAN
CENTERED
ELEVATION
KNEE CLEARANCE
ALCOVE
FORWARD
ALCOVE
PARALLEL
180 DEG
TURN AROUND
NARROW
PASSAGE
SINGLE
WHEELCHAIR
T-SHAPE
TURN AROUND
CIRCLE
TURN AROUND
BEVELED TRANSITION
VERTICAL TRANSITION
PROTRUDING
OBJECT
UNDER STAIRS
FORWARD REACH RANGES SIDE REACH RANGES
BACK WALLBACK WALL
LENGTH
REMOVABLE SEAT CONTROLS LOCATION FIXED SEAT
REMOVABLE SEAT FIXED SEAT
CO
NT
RO
L
WA
LL
BACK
SE
AT
WA
LL
SE
AT
TRANSFER SHOWER ROLL-IN SHOWER ROLL-IN SHOWER
W/ SEAT ROLL-IN SHOWER
W/ SEAT
ALTERNATE
BACKWALL
CONTROL WALL
WITHOUT SEAT
CONTROL WALL
WITH SEAT
SHOWER SEAT
BENCH SEATINGTHEATER SEATING
BENCH SEATINGTHEATER SEATING
LINE OF SIGHT
LINE OF SIGHT
SPORTS ARENA
THEATER/PLAYHOUSE
AUDITORIUM/CONCERT HALL
LECTURE HALLS
MEETING ROOMS
OF TUB
CO
NT
RO
L E
ND
WA
LL
HE
AD
EN
D W
ALL
LENGTH
OF TUB
WA
LL/P
OS
T M
TD
CA
NT
ILE
VE
RE
D
UN
IT
FORWARD APPROACH
ACCESSIBLE UNIT
PROTRUDING
OBJECT
NOTE:
WIDE SIDE
LEVER ON
250 LBS AND BE CONTINUOUS
GRAB BARS MUST SUPPORT
DOWN TO 27" AFF MIN
APRON THAT EXTENDS
HIGH UNIT SHOULD HAVECL
BRACKET MOUNTED
FIRE EXTINGUISHER* CHALKBOARD MOUNTING
* MARKERBOARD MOUNTING
FIRE ALARM
AUDIBLE &
ACCESSIBLE
COAT HOOKS
VISUAL SIGNAL
OUTLET
* TACKBOARD MOUNTING
CABINET
FIRE EXTINGUISHER
TOWELS
MISC MOUNTING (DIMENSIONS SHOWN ARE TO THE HIGHEST OPERABLE PART)
TELEPHONE
THERMOSTAT
TOWELS
SWITCH
OUTLET
CUPS
SOAP
TO
P O
F E
XT
ING
UIS
HE
RIN
SID
E O
F C
AB
INE
T
TO
P O
F T
RA
Y
FIN CLGIF CEILING IS BELOW 90"
MOUNT TOP OF SIGNAL DEVICE
6" BELOW FINISHED CEILING
NOTE:
EQUIPMENT PERMITTED
IN OUTLINED AREA
WASHING MACHINE
TOP LOAD
CONVEYOR
GROCERY
SLIDE
TRAYACCESSIBLE
COAT HOOKSAMBULATORY ACCESSIBLE TOE CLEARANCE SIDE APPROACH WALL HUNG WATER CLOSET FLOOR MTD WATER CLOSET
CL
HE
AD
EN
D
(REQUIRED) (REQUIRED)
WA
LL
CL
PUSH SIDE
NOTE:
PULL SIDE
FRONT APPROACHES SWINGING DOORS
HAS BOTH A CLOSER AND A LATCH
X = 12" MIN (305mm) IF DOOR
PUSH SIDE
PUSH SIDE
NOTE:
A CLOSER
PULL SIDE
A CLOSER
Y = 54" MIN (1370mm) IF DOOR HAS
NOTE:
PULL SIDE
NOTE: X = 36" MIN IF Y = 60";
X = 42" MIN IF Y = 54"
HINGE SIDE APPROACHES SWINGING DOORS
LATCH SIDE APPROACHES SWINGING DOORS
Y = 48" MIN (1220mm) IF DOOR
HAS BOTH A CLOSER AND A LATCH
Y = 48" MIN IF DOOR HASNOTE:
VESTIBULE DOORS
TWO HINGED DOORS IN SERIES
NOTE:
THE CLEARANCES FOR FRONT APPROACHES
ALL DOORS IN ALCOVES SHALL COMPLY WITH
VESTIBULE DOORS
RECESSED DOOR
DOOR HARDWARE DOOR LITE
CLOSER & LATCH PROVIDED
WALL
CL
14-1720-25
18
40
LOW
HIGH
TOP OF HANDRAIL GRIPPING SURFACE
GRAB BARSDISPENSER HEIGHT
36
20
28 MAX
18-2014
KNEE CLEARANCE
HEIGHT OF TABLES OR COUNTERS
24 MIN
26-30 MAX
AGES: 3 AND 4 AGES: 5 THROUGH 8
17-1925-27
16
44
AGES: 9 THROUGH 12
WATER CLOSET CENTERLINE 12-1512 15-18
CLEARANCE AT WATER CLOSET
LAVATORY, URINALOR TOILET ACCESSORIES
NOT IN A STALL
CL
IF Y=60 MIN, X=36 MINLINE OF SIGHT OVER HEADS
FRONT LOAD
APPROACH ALLOWED
PARALLEL
AGES: 5 & YOUNGER AGES: 6-12
LETTERS & BRAILLE
GRAPHIC SYMBOLS
6x8 PICTOGRAM
MEN
6x8 PICTOGRAM
GRAPHIC SYMBOLS
LETTERS & BRAILLE
WOMEN
& BRAILLE
ROOM NUMBER
8x6 ROOM NAME
129SUPERVISOR
MAINTENANCE
& BRAILLE
10x3 ROOM NAME
ADMINISTRATION
6x6 DIRECTIONAL
GRAPHIC SYMBOL
ONLY ONLY
GRAPHIC SYMBOL
6x6 DIRECTIONAL
& BRAILLE
6x6 CHANGEABLE
MESSAGE W/ PERMANENT
ROOM NAME, NUMBER,
ITHJOHN S
OFFICE
169
REFER TO SIGNAGE PACKAGE OR DETAILS FOR ACTUAL SIGNAGE SPECIFIED
6x8 PICTOGRAM
GRAPHIC SYMBOLS
LETTERS & BRAILLE
STAIR 1
6x8 PICTOGRAM
GRAPHIC SYMBOLS
LETTERS & BRAILLE
STAIR 1
DISPENSERS
IF A WALL HUNG OR FLOOR
MOUNTED FLUSH VALVE
WATER CLOSET IS SPECIFIED,
ENSURE ALL DIMENSIONS
SHOWN ARE MET.
CL
REFER TO KNEE AND
TOE CLEARANCE GRAPHICS
CL
NOT ASSOCIATEDWITH A WATER CLOSET
ONLY TOILET
ASSOCIATED WITHWATER CLOSETS AREALLOWED WITHINFLOOR AREA
ACCESSORIES
28 MAX 28 MAX
NOTE: REFER TO "CHANGES IN LEVEL" DETAILS FOR SHOWER THRESHOLDS
THRESHOLD
SEAT
SEATTHRESHOLD THRESHOLD
12
1/4
VERTICAL/BEVELED
1/4
TRANSITION
CLEAR FLOOR AREA/ACCESSIBLE ROUTE
PROTRUDING OBJECT PROTECTION/REACH RANGES SHOWERS
ASSEMBLY SEATING
URINALSTYPICAL WATER CLOSETS
EWC/DRINKING FOUNTAINS
STANDARD ACCESSIBLE MOUNTING HEIGHTS TYPICAL TOILET STALLS
TUBS
TYPICAL DOOR CLEARANCES
GENERAL NOTES
EXAMPLE SIGNAGE - SEE STANDARD ACCESSIBLE MOUNTING HEIGHT
LAVATORIES
CHANGES IN LEVEL
ACCESSIBLITY GUIDELINE SHEETS ARE BASED ONCHAPTER 11, ACCESSIBILTY OF THE NEW MEXICOBUILDING CODE, AND SUPERCEDE CHAPTER 11ACCESSIBILITY OF THE INTERNATIONAL BUILDING CODE.THE ADOPTED STANDARD OF QUALITY FOR ACCESSIBLEDESIGN IS THE ICC/ANSI A117.1-2009 "ACCESSIBLE ANDUSABLE BUILDINGS AND FACILITIES.'ACCESSIBILITY GUIDELINE SHEETS ARE FORINFORMATIONAL PURPOSES ONLY AND INTENDED TOSERVE AS A GUIDE FOR CONSTRUCTION PROFESSIONALSAND OWNERS.SOME OF THE INFORMATION AND PICTOGRPAHS SHOWNMAY NOT BE APPLICABLE TO THIS PROJECT.REFER TO PLUMBING SHEETS FOR PLUMBING FIXTUREMOUNTING HEIGHTS.GRAPHICS SHOWN ARE FOR ADULTSSEE SHEET G-002 FOR TYPE B HOUSING REQUIREMENTS.
VERTICAL GRAB BAR 18"MIN IN LENGTH MOUNTEDW/ BOTTOM OF BAR @ 39INCHES MIN AND 41 INCHESMAX ABOVE FLOOR, & WITHCENTER LINE OF BARLOCATED 39 INCHES MINAND 41 INCHES MAX FROM THEREAR WALL [REF:ANSI 604.5.1]
ISSUING OFFICE: PROJECT NO:
KEY PLAN
654321
654321
A
B
C
D
E
NO DATE DESCRIPTION
12/13/17 75% CD0
12/1
2/2
017 2
:57:1
7 P
M
ACCESSIBILITY
STANDARDS
G-004
NEW RESIDENCE
HALL
75% CONSTRUCTION
DOCUMENTS
LAS CRUCES, NEW MEXICO 88003
LAS CRUCES 8919.17
RE
VIT
_v16
THIS DOCUMENT IS RELEASED ON12-13-2017 FOR THE PURPOSE OFINTERIM REVIEW UNDER THEAUTHORITY OF KIM M HOOKER,R.A., NEW MEXICO LICENSE #2828.IT IS NOT TO BE USED FORREGULATORY APPROVAL,CONSTRUCTION, BIDDING ORPERMIT PURPOSES.PARKHILL, SMITH & COOPER, INC.
PUSH FOR HELP
EMERGENCY
PHONE
1«
ACCESSIBLE RAMP
ELEVATORS
ELEVATORS
ACCESSIBLE PARKING SIGNAGE PARKING SPACESPASSENGER LOADING ZONE
ACCESSIBLE ROUTE FROM PARKING
CURB RAMPS AT MARKED CROSSINGSCURB RAMPS
PROTRUDING OBJECTS/TELEPHONES
ACCESSIBLE ROUTES
ACCESSIBLE SEATING
BUS STOPS
LULA LIFTS
60 MINSLOPE 1:12 MAX60 MIN
42 MIN
54 M
IN
32 MIN
32 MIN
42 M
IN
60 MIN
36 MIN
60 M
IN
80 MIN
51 M
IN
54 M
IN
42 MIN
80 M
IN
36 MIN 36 MIN
54 M
IN
51 M
IN
68 MIN
54 MIN
48 M
AX
72
29
5
48 M
AX
60
2
35 M
IN
3/4 MIN
2 1
/2 M
IN
2 1
/2 M
IN
60 MIN 60 MIN 60 MIN
60 M
IN
36 MINBETWEEN
HANDRAILS
36 M
INB
ET
WE
EN
HA
ND
RA
ILS
12 MIN12 MIN
X<
4
27 M
AX
34-3
8
34-3
8
36 MIN
TOP & BOTTOMOF RAMP
12 MIN
CL
CL
80 M
INX>12
X>12
27 M
AX
12MAX
27-8
0 12 MAX
36 MIN
48 M
IN
36 MIN
96 MIN(8'-0")
5'-0"
MIN
FULL LENGTH OFVEHICLE PULL-UP SPACE
20'-0" MIN
60 MIN(5'-0")
132 MIN(11'-0")
X
48M
IN
X
X
48M
IN
36M
IN
60 M
IN
36 M
IN
12 MAX
27-8
0
30 MIN
48
MIN
48
30
36
36
36
MIN
36
MIN
36
MIN
36
MIN
36MIN
48
MIN
12
MAX
12
MAX
2 1/2MAX
4M
AX
4MAX
4MAX
36MIN
1:1
2 S
LO
PE
MA
X
18
MIN
51 M
IN
36 MIN
51 MIN
24
MIN
8'-0"
MIN
DIRECTION
HANDRAILS
LANDING
RAMPLANDING
EDGE PROTECTION CURB/BARRIER OR 12" EXTENDED
HANDRAILS REQUIRED ON BOTH SIDES OF RAMP
RAMP WIDTH TO BE NO LESS THAN 36" BETWEEN
RAMP CROSS SLOPE NOT TO EXCEED 2% MAX
LANDING SLOPE NOT TO EXCEED 2% IN ANY
SURFACE REQUIRED ON BOTH SIDES OF
RAMP RUN LANDINGLANDING
LANDING
RAMP RUN
RAMP RUN
EXTENDED
SURFACE
CURB OR
BARRIER
OFF-CENTERED DOOR
RAISED OR FLUSH
ENTRY LEVEL
DOOR OPEN
ALARM
DOOR CLOSE
EMERGENCY
CAR FLOOR
HE
IGH
T W
ITH
IN
RE
AC
H R
AN
GE
PLATFORM
LIF
T M
EC
HA
NIS
M
(NEW CONSTRUCTION)
DOOR SAFETY BEAMS HALL LANTERNS HALL CONTROLS
INSIDE CABFLOOR DESIGNATION
BESIDE DOOR ABOVE DOOR EMERGENCY
COMMUNICATION
DEVICEOUTSIDE CAB CAR CONTROL DETAILS
SECTION
MAIN
CENTERED DOOR
STOP
1/2 MAX
201 1
12
60 MIN
96 M
IN
PERPENDICULAR SIDEWALK PARALLEL SIDEWALKW/ IN-LINE CURB RAMP W/ PARALLEL CURB RAMP
PERPENDICULAR SIDEWALKW/ FLARED CURB RAMP
BUILT-UP CURB RAMPPERPENDICULAR SIDEWALKW/ LONGITUDINAL CURB RAMP
17-1
9
20-24
42 M
IN2 M
AX
10 M
AX
20 M
AX
FIN GRADE
5'-0" ABOVE
CAR
24MIN
24MIN
60 MIN
96 M
IN
WHEEL STOP36
MIN
36M
IN36MIN
36MIN
60 MIN60 MIN
ACCESSIBLE ROUTE
CURB RAMP WITHIN
MARKED CROSSINGSTRAIGHT
SEGMENT
WITHIN
CROSS WALK
CURB RAMP WITHIN
MARKED CROSSING
CURB RAMP
MARKED
CROSSING
CURB RAMP
MARKED
CROSSING
1:12 MAX IF
X IS < 36
STRAIGHT
SEGMENT WITHIN
CROSS WALK
ISLAND CUT THROUGH
LEVEL WITH STREET
WELL DEFINED
EDGE
NON-WALKING
SURFACE
NON-WALKING
SURFACE
ISLAND CUT THROUGH
LEVEL WITH STREET
TYPICAL
LONG DIRECTION
PERPENDICULAR TO
DOMINANT DIRECTION
OF TRAVEL
GRATING PASSING SINGLE
2.35
2.3
5
0.9
0.2
DETECTABLE WARNING
DEVICES SHALL COMPLY
WITH THE TEXAS
ACCESSIBILITY STANDARDS
AND BE ALIGNED IN THE
DIRECTION OF
PEDESTRIAN TRAVEL
THE SURFACE OF THE
DETECTABLE WARNING
DEVICES SHALL BE A
CONTRASTING COLOR
THAT PROVIDES A LIGHT
REFLECTIVE VALUE
SIGNIFICANTLY
CONTRASTING WITH THE
ADJACENT SURFACES
FLARED SIDES
24
MIN
1:10
MAX
SLOPE
EACH SIDE
CHANGE IN DIRECTION
SLOPED SURFACE WHERE VERT EDGE IS > 8"
AT
LE
AS
T A
S
WID
E A
S T
HE
WID
ES
T R
AM
P R
UN
STRAIGHT
OR
NON-WALKING
SURFACE
NON-WALKING
SURFACE
BOTTOM OF RAMP SURFACE
DETAIL
FLARED SIDES
1:12 MAX IF
X IS < 36"
ENLARGED PLAN
ENLARGED PLAN
ENLARGED PLAN
ENLARGED PLAN
2% MAX SLOPE
CURB RAMP CONFIGURATION MAY VARY
CURB RAMP
ACCESSIBLE
ROUTE
BUS
STOP
PAD
CURB OR
ROADWAY
EDGE
ACCESSIBLE PATH
OF TRAVEL
TELEPHONES
OVERHANG
POST
FORWARD
APPROACH
ACCESSIBLE PATH WIDTH
PROTRUDING OBJECTS
CURB RAMP AND ADJOINING SURFACE SLOPES
(D)(C)
(B)(A)
WITHIN CURB RAMP AND FLARES, THERE SHALL BE NO LIGHT OR SIGNAL
POLES, SIGNAL BOXES, VALVE BOX COVERS, OR THE LIKE
ISLAND
ISLAND
FLARED SIDES
1:12 MAX IF
X IS < 36"
ISLAND
PARALLEL
APPROACH
PLAN
NON-WALKING SURFACE
NON-WALKING
SURFACE
ACCESSIBLE
ROUTE
SHELTER
BUS
STOP
PAD
CURB OR
ROADWAY
EDGE
OVERHANG
SIGNS
OVERHANG
POST
CUT THROUGH AT ISLAND CURB RAMP AT ISLAND
CURB RAMP
MAX SLOPE
ADJOINING
SURFACE
MAX SLOPE
DOMINANT DIRECTION
OF TRAVEL
DOOR FRAME
(ABOVE CAR CONTROL PANEL)
VAN
PARKING SPACES AND ACCESS AISLESLOPE NOT TO EXCEED 2% IN ANY DIRECTION
8
3
1
4
2
7
5
8
6
1
3
2
4
5
7
6
8
8 1
1 2
VAN ACCESSIBLE
VAN ACCESSIBLE
BLUE PLACARD ONLY
PARKINGRESERVED
BLUE PLACARD ONLY
PARKINGRESERVED
PARKINGRESERVED
PARKINGRESERVED
BLUE PLACARD ONLY
1«
1« 2
1« 2
43
5 6
7 8
UP
WW1578TSLWW2572DSTF3L
WW
2460R
ST
FR
L
WW
2318P
UB
BF
LW
W1572T
SL
UP
WW1578TSLWW2572DSTF3L
WW
2460R
ST
FR
L
WW
2318P
UB
BF
L
WW
1572T
SL
GENERAL CONSTRUCTION INFORMATION
BUILDING
PLUMBING
MECHANICAL
ELECTRICAL
FIRE
ACCESSIBILITY
IBC 2015
UPC 2012
UMC 2012
NEC 2014
NFPA by Reference
2009 IECC
IBC 2015, CH. 11; ICC/ANSI A117.1-2009
ENERGY
APPLICABLE CODES:
LEED Certification Req. LEED v4 for BD+C: New Construction & Major Renovation
FRONTAGE AND AREA INCREASES
DESIGN CONDITIONS
PERIMETER ALLOWED (FT) (F)
PERIMETER TOTAL (FT) OF ENTIREBUILDING (P)
WIDTH OF PUBLIC WAY OR OPEN SPACE (W)
INCREASE (PERCENT) DUE TO FRONTAGE (LF)
CONSTRUCTION TYPE
OCCUPANCY CLASSIFICATION
BUILDING: *ENTIRE -OR- AREA*
FLOOR AREA - FIRST FLOOR
TOTAL FLOOR AREA-INCLUDING ALLFLOORS
STORIES
BUILDING HEIGHT
SPRINKLER SYSTEM PROVIDED
SPRINKLER SYSTEM TYPE
805
PROVIDED ALLOWED
(BEFORE INCREASE)
925
30'
GROUP
H
GROUP
R
ALL
OTHERS
SINGLE & MULTI STORY NON-SPRINKLED
AREA PER FLOOR (SQUARE FEET)
STORIES
HEIGHT
MAX. TOTAL BLDG. AREA (INCLUDING ALLSTORIES)
PROVIDED ALLOWED +/- COMPLIES
SINGLE STORY - SPRINKLED
INCREASE DUE TO SPRINKLER PROTECTION(PERCENT) (I )
FLOOR AREA (SQ FT)
HEIGHT (REF. 504.2, EXCEPTION #1)
PROVIDED ALLOWED +/- COMPLIES
NOTES
1. R-2 RESIDENTIAL WING + A-3 SOUTH WING = EXCEED ALLOWABLE SF (PERFLOOR, PER AREA INCREASE CALCULATION). FIRE WALL USED TO SEPARATETWO OCCUPANCIES AND TO REDUCE FLOOR AREA SO THAT R-2 RESIDENTIALWING IS WITHIN ALLOWABLE SF.
2.EXTERIOR WALL PROTECTION @ FIRE WALL- HORIZONTAL: EXTEND FIRE BARRIERHORIZONTALLY, A DISTANCE NOT LESS THAN 4 FEET AT EXTERIOR WALL AND WITH AFIRE RESISTANCE OF NOT LESS THAN ONE HOUR. SEE DETAIL FOR EIFS ON FRSHEATHING AT NOTED AREA. [REF 706.5]
3. EXTERIOR WALL PROTECTION @ FIRE WALL- VERTICAL: VERTICALCONTINUITY - TWO-HOUR FIRE-RESISTANCE-RATED WALLS SHALL BEPERMITTED TO TERMINATE AT THE UNDERSIDE OF THE ROOF SHEATINGPROVIDED (1) THE LOWER ROOF ASSEMBLY WITHIN 4 FEET OF THE WALL HASNOT LESS THAN 10HOUR FIRE-RESISTANCE RATING AND THE SUPPORTINGELEMENTS FO RTHE ROOF ASSEMBLY HAS A FIRE-RESISTANCE RATING OF NOTLESS THAN 1 HOUR; (2) NO OPENINGS IN ROOF WITHIN 4 FEET OF THE FIREWALL; (3) EACH BUILDING SHALL BE PROVIDED WITH NOT LESS THAN A CLASS BROOF COVERING. [REF 706.6]
4. EXTERIOR WALL PROTECTION @ FIRE WALL - EXTERIOR WALL TO HIGHER ROOF:EXTERIOR WALL FRO A HEIGHT OF 15 FEET ABOVE THE LOWER ROOF ...NOT LESSTHAN 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION AND OPENING PROTECTIONRATING OF NOT LESS THAN 3/4 HOUR. [REF 706.6.1]
R-2
V B
63,274
3
56'
YES
NFPA 13R
- - -
- - -
- 7000 -
- - -
- - -
56 70 -14 YES
20' 60' -40' YES
3 4 -1 YES
21,391 25,340 -3,949 YES
63,274 76,020 7,562 YES
5,184 - -18,816 YES
24,000
OCCUPANT LOAD (TAB 1004.1.1)
ASSEMBLY565 SF @ 5 SF PER PERSON1,645 NSF @ 7 SF PER PERSON3270 @ 15 SF PER PERSON
BUSINESS214 SF @ 100 SF PER PERSON
STORAGE/MECHANICAL2,500 SF @ 300 SF PER PERSON
TOTAL
113235218
3
9
1,756
# OF PEOPLEOCCUPANT LOAD
ACCESSORY STORAGE AREAS, MECHANICAL
OCCUPANT PER SFFUNCTION OF SPACE
EQUIPMENT ROOM 300 GROSS
AGRICULTURAL BUILDING 300 GROSS
AIRCRAFT HANGARS 500 GROSS
AIRPORT TERMINAL
BAGGAGE CLAIM 20 GROSS
BAGGAGE HANDLING 300 GROSS
CONCOURSE 100 GROSS
WAITING AREAS 15 GROSS
ASSEMBLY
GAMING FLOORS (KENO, SLOTS, ETC.) 11 GROSS
ASSEMBLY W/ FIXED SEATS SEE SECTION 1004.7
ASSEMBLY WITHOUT FIXED SEATS
CONCENTRATED (CHAIRS ONLY-NOT FIXED) 7 NET
STANDING SPACE 5 NET
UNCONCENTRATED (TABLES AND CHAIRS) 15 NET
7 NET
BUSINESS AREAS 100 GROSS
COURT ROOMS-OTHER THAN FIXED SEATING AREAS 40 NET
DAY CARE 35 NET
DORMITORIES 50 GROSS
EDUCATIONAL
CLASSROOM AREA 20 NET
SHOPS AND OTHER VOCATIONAL ROOM AREAS 50 NET
EXERCISE ROOMS 50 GROSS
H-5 FABRICATION AND MANUFACTURING AREAS 200 GROSS
INDUSTRIAL AREAS 100 GROSS
INSTITUTIONAL AREAS
INPATIENT TREATMENT AREAS 240 GROSS
OUTPATIENT AREAS 100 GROSS
SLEEPING AREAS 120 GROSS
KITCHENS, COMMERCIAL 200 GROSS
LIBRARY
READING ROOM 50 NET
STACK AREA 100 GROSS
LOCKER ROOMS 50 GROSS
MERCANTILE
AREAS ON OTHER FLOORS 60 GROSS
BASEMENT AND GRADE FLOOR LEVELS 30 GROSS
STORAGE, STOCK, SHIPPING AREAS 300 GROSS
PARKING GARAGES 200 GROSS
RESIDENTIAL 200 GROSS
SKATING RINKS, SWIMMING POOLS
RINK AND POOL 50 GROSS
DECKS 15 GROSS
STAGES AND PLATFORMS 15 NET
WAREHOUSES 500 GROSS
BOWLING CENTERS, ALLOW 5 PERSONS FOR EACHLANE INCLUDING 15 FEET OF RUNWAY, AND FORADDITIONAL AREAS
FIRE PROTECTION RQMTS (TABLE 601)
EGRESS
TOTAL OCCUPANT LOAD FOR THE BUILDING
TOTAL OCCUPANT LOAD EGRESS WILL ACCOMODATE 2560 PEOPLE
EGRESS WIDTH REQUIRED
1,756 X 0.15 (SEC 1005.3.2 Exception for Sprink) 264 INCHES
EGRESS PROVIDED
MAXIMUM ALLOWABLE TRAVEL DISTANCE(TABLE 1017.2)
LONGEST TRAVEL DISTANCE
250 FEET (SPRINKLED BLDG.)
MAXIMUM DEAD END LIMIT (SECTION 1018.4)
203 FEET (SPRINKLED BLDG.)
MAXIMUM DEAD END LIMIT PROVIDED
50 FEET
COMMON PATH OF EGRESS TRAVEL (1006)
COMMON PATH OF EGRESS TRAVEL PROVIDED
125 FEET
TWO EXITS REQUIRED WITH OCCUPANT LOAD OF 50PLUS (TABLE 1015.1)
52 FEET
MINIMUM NUMBER OF EXITS FOR OCCUPANT LOAD(TABLE 1021.1)
1-500 2 EXITS
501-1000 3 EXITS
MORE THAN 1000 4 EXITS
1756 PEOPLE
384 INCHES
12 FEET
STRUCTURAL FRAME
EXTERIOR BEARING WALLS
INTERIOR BEARING WALLS
FLOOR CONSTRUCTION
ROOF CONSTRUCTION
CORRIDORS (TABLE 1018.1)
0 HOUR(S), *
CONSTRUCTION TYPE - TYPE V-B
0 HOUR(S)., *
0 HOUR(S)
1/2 HOUR(S)
0 HOUR(S) - CLASS C
0 HOUR(S)
1/2 HOUR(S) W/ SPRINKLER SYSTEM
EXTERIOR WALLS (TABLE 602)
PLUMBING FIXTURE RQMTS - IPC
DESCRIPTION:OCCUPANCY:
LAV'S DRINK
FOUNT.
REF.410.1
SE
RV
ICE
SIN
K
M FUR
INA
LS
WATER
CLOSETS
M F
OC
CU
PA
NT
LO
AD
(A
CT
UA
L)
US
EG
RO
UP
RESIDENTIAL
TOTAL REQUIRED:
TOTAL PROVIDED:
A-3 130
1
1
1
1
0
0
1
1
1
1
1 1
aboveabove
OTHER
DESCRIPTION:OCCUPANCY:
LAV'S DRINK
FOUNT.
REF.410.1
SE
RV
ICE
SIN
K
M FUR
INA
LS
WATER
CLOSETS
M F
OC
CU
PA
NT
LO
AD
(A
CT
UA
L)
US
EG
RO
UP
ASSEMBLY
TOTAL REQUIRED
TOTAL PROVIDED
A-3 348
1
1
3
3
1
1
1
1
1
2
1 1
22
OTHER
DESCRIPTION:OCCUPANCY:
LAV'S DRINK
FOUNT.
REF.410.1
SE
RV
ICE
SIN
K
M &FUR
INA
LS
WATER
CLOSETS
M & F
OC
CU
PA
NT
LO
AD
(A
CT
UA
L)
US
EG
RO
UP
RESIDENTIAL
TOTAL REQUIRED
TOTAL PROVIDED
R-2 1181
118
147
0
0
118
237
12 1
312
OTHER
PLUMBING FIXTURE RQMTS - IPC
TOILETS
LAVATORIES
TOILETS
LAVATORIES
DRINKING FOUNTAIN (ADA HI/LO)
SERVICE SINK
REQUIRED PROVIDED
REQUIRED PROVIDED
REQUIRED PROVIDED
4
2
4
3
3
2
3
2
13 MAX
2
13
4
FIXTURE COUNT FEMALE A-3 (103) TABLE 403.1
FIXTURE COUNT MALE A-2 (103) TABLE 403.1
FIXTURE COUNT DRINKING FOUNTAIN & SERVICE SINKTABLE 104.3
(3)
(2)
(2)
(4)
s
(2,3) (2,4)
NORTH TOWER LOBBY
CLASSROOMS/LOBBY
DORMITORY ROOMS
NMSU will adopt IFC 2018 in January 2018, and will adopt all IBC Codefamilies at that time (IBC etc.) [Ref 8/10/17 Meeting]
RESIDENTIAL59,050 SF @ 50 SF PER PERSON
1181
TOILETS
LAVATORIES
REQUIRED PROVIDED
118
118
147
236
FIXTURE COUNT MALE/FEMALE R-2 (103) TABLE 403.1
SHOWERS 147 147
C = ROOM WITH COMMUNICATION FEATURES PER ADA 2010, SECTION 224.4.
40' w/ accent tower + 16'
R-2 BLDG: RESIDENTIAL USE
A-3 BLDG: SOUTH WING
R-2 BLDG & A-3 BLDG SEPARATED BY 2-HOUR FIRE WALL
INCR. NOTUSED/NEEDED
SH
OW
ER
S
147
147
TABLE 706.4, FOOTNOTE (a).
ROOF CONSTRUCTION DUE TO FIRE WALL 0 HOUR(S) - CLASS B
* SEE NOTES AT BOTTOM OF SHEET FOR CONSTRUCTION IN THE VICINITY OF THE FIREWALL
PROVIDED =R-2 AREA ONLY
TOTAL BUILDING AREA: R-2 + A-3
R-2 AREA (BASEMENT + 3 STORIES)
A-3 (1 STORY)
TOTAL
PROVIDED
68,458
5,184
63,274
R-2 SEP FROM A-3 BY 2-HR FIRE WALL
EGRESS EXIT REQUIRED
EGRESS PATH AND TRAVEL DISTANCE
1/2 HOUR FIRE BARRIER W/ 20 MINUTE SMOKE &DRAFT CONTROL OPENING & DOOR ASSEMBLIES.
1 HOUR FIRE BARRIER WITH 1 HOUR SMOKE &DRAFT CONTROL OPENING & DOOR ASSEMBLIES.
2 HOUR FIRE BARRIER WITH 90 MINUTE SMOKE &DRAFT CONTROL OPENING & DOOR ASSEMBLIES.
DISTANCE BETWEEN EXITS
EXIT WIDTH PROVIDED AT SPECIFIC EXIT
GROSS SQUARE FEET
NET SQUARE FEET
FIRE EXTINGUISHER CABINET / SEE D5/A-501
TRAVEL DISTANCE
COMMON PATH OF TRAVEL
(MINIMUM) DISTANCE BETWEEN EXITS
OCCUPANT LOAD
EXIT
EW=36"
GSF
NSF
FEC
TD
CPOT
(M)DBE
OL
200'
ASSEM 2080
15 NET 139
.2 27.8" 140"
FUNCTION OF SPACE (TABLE 1004.1.2)
TOTAL FLOOR AREA (SF)
CALCULATED OCCUPANT LOAD OFSPACE
EGRESS WIDTH PROVIDED (INCHES)
MINIMUM EGRESS WIDTH REQUIRED(INCHES)
EGRESS WIDTH FACTOR (SECTION1005.3.1 FOR STAIRS; 1005.3.2 FOROTHERS)
FLOOR AREA (SF) PER OCCUPANT(TABLE 1004.1.2)
200'
459 0.2
32" 36"
TOTAL OCCUPANT LOAD PER EXIT
EGRESS WIDTH FACTOR (SECTION 1005.3.1FOR STAIRS; 1005.3.2 FOR OTHERS)
EGRESS WIDTH PROVIDED (INCHES)
MINIMUM EGRESS WIDTH REQUIRED(INCHES)
LEGENDRoll-in Shower
Roll-inShower
Tub/Shower
C
C
C
C
C
Transfer Shower
TransferShower
TransferShower
C
C
C
C
C
Transfer Shower
Roll-inShower
C
C
C
C
815 SF117
ASSEM7 SF
64"0.15 32"
CLASSROOM B
185
821 SF118
ASSEM7 SF
64"0.15 32"
CLASSROOM A
184
73 SF2
BUS100 SF
32"0.15 32"
FRONT DESK
180B
?
?
BED
160
BIKE STORAGE
102
BED
104
BED
103
BED
105
BED
114
BED
116
BED
132
BED
138BED
142
BED
144
BED
143
BED
149
BED
154BED
158
STAIR
ST001
STAIR
ST002
BED
162
BED
164
BED
163
ELEV
E012
354 SF24
ASSEM15 SF
64"0.15 32"
LOUNGE
121A
BED
165
BED
166
BED
167
BED
168
M
M101D
M
R125
W
R124
HK
J109
ITC
T107
BED
136
BED
118
BED
120
BED
134
ELEC
T159
BED
152
BED
106
BED
161
195 SF1
STOR300 SF
64"0.2 32"
STORAGE
184A
N HALL
H157
BED
115
BED
119
BED
117
N HALL
H113A
BED
156
NORTH
LOBBY
H121
BED
146
BED
148
BED
150
BED
131
BED
137
BED
141BED
135
BED
133
BED
145
BED
147
BED
140
BED
139
M
R187
W
R188
BED
151
OUTDOOR E/W
PASSAGE
H100
VEST
H111
BED1
101A
BED2
101B
W/D
M
M112
M
M103
M
M114
M
M118
M
M117
VEST
H122
VEST
H123
VEST
H170
STAIR
ST004
E HALL
H169
M
M115
M
M131
M
M140
M
M139
M
M144
M
M143
M
M147
M
150D
M
M156
M
M161
M
M162
M
M152
M
M132
M
M135
M
M136
M
M165
M
M166
BED
110
M
M110
BED
108
M
M108
BED
112
W HALL
H113
M
M151
59
64"
0.15
32"
CLASSROOM A
184
60
64"
0.15
32"
CLASSROOM B
185
OCCUPANCY
SEPARATION
R-2
A-3
563 SF113
ASSEM5 SF
32"0.15 32"
LOUNGE
180C
141 SF2
BUS100 SF
32"0.15 32"
OFFICE
189
M
M160
RESIDENT
DIRECTOR APT
101
BATH
101C
178 SF25
ASSEM7 SF
64"0.15 32"
LOUNGE
121B
157 SF1
STOR300 SF
64"0.2 32"
STORAGE
185A
52'
FIRE WALL
168'
220'
EXIT
42/2
=21
' EXIT
EX
IT
EX
IT
>21' FROMOTHER EXIT
72'EXIT
4' - 0"1-HR WALL
4' -
0"
1-H
R W
ALL
1 3/8"
4' - 0"1-HR WALL
FEC
FEC
FEC
FEC
FEC
ISSUING OFFICE: PROJECT NO:
KEY PLAN
654321
654321
A
B
C
D
E
NO DATE DESCRIPTION
12/13/17 75% CD0
12/1
2/2
017 2
:58:2
1 P
M
CODE INFORMATION - 1ST
FLR CODE PLAN
G-005
NEW RESIDENCE
HALL
75% CONSTRUCTION
DOCUMENTS
LAS CRUCES, NEW MEXICO 88003
LAS CRUCES 8919.17
RE
VIT
_v16
THIS DOCUMENT IS RELEASED ON12-13-2017 FOR THE PURPOSE OFINTERIM REVIEW UNDER THEAUTHORITY OF KIM M HOOKER,R.A., NEW MEXICO LICENSE #2828.IT IS NOT TO BE USED FORREGULATORY APPROVAL,CONSTRUCTION, BIDDING ORPERMIT PURPOSES.PARKHILL, SMITH & COOPER, INC.
1. UL ASSEMBLIES INDICATED ESTABLISH A BASIS PERFORMANCE. OTHERASSEMBLIES MAY BE CONSIDERED AT THE DISCRETION OF ARCHITECT IFEQUIVALENT PERFORMANCE IS PROVIDED. SUBSTITUTION PROPOSALS SHALLINCLUDE CHANGES REQUIRED TO ALL COMPONENTS OF THE ASSEMBLY.
2. FIRE EXTINGUISHERS, (IFC SECTION 906 AND NFPA 10; CHAPTER 6 AND TABLE 6.2.1.1,CLASS-A LIGHT HAZARD OCCUPANCY) MAXIMUM FLOOR AREA FOR UNIT-11 - 250 SF;MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER - 75 FT.
3. AHJ DETERMINATION REQUESTED FOR STAIR 002. SHAFT SHOWN AS 2-HOUR &CONNECTING 4 STORIES (3 FLOORS + BASEMENT). ACCESS TO BASEMENTSEPARATED BY 1-HOUR CONSTRUCTION. DETERMINE IF 1-HOUR SHAFT ACCEPTABLE(& ASSOCIATED REDUCTION IN OPENING PROTECTION AT DOORS).
4. SOUND TRANSMISSION CLASS (STC) RATINGS REQUIRE ASSEMBLIESTHAT EXCEED THE REQUIRED FIRE-RESISTIVE ASSEMBLIES. SEE PARTITIONLEGEND.
AS INDICATED BY: #
KEY NOTES
GENERAL NOTES
1" = 40'-0"E11ST FLOOR - ACCESSIBILITY FEATURES
1" = 40'-0"D12ND FLOOR - ACCESSIBILITY FEATURES
1" = 40'-0"C13RD FLOOR - ACCESSIBILITY FEATURES
1/16" = 1'-0"A1FIRST FLOOR - CODE PLAN
SEE 2ND FLOOR PLAN FOREXIT INCHES REQUIREMENTAT DOOR TO STAIR & STAIR WIDTH
DW DDDDW W W W
DDW W W
LOUNGE
6491 GSF @ 50 GSF/OCCW WING + N WING W OF LOBBY = 130 OCC
FIRE WALL
OCCUPANT LOAD OF NORTH WING EAST OF LOBBY + LOBBY + EAST WING = 287 OCC. X 0.15 IN/OCC = 43" MIN CORR WIDTHMIN CORR REQ'D: 44"CORR PROVIDED: 49"
678 SF
43
ASSEM
15 SF
0"0.2 0"
LOUNGE
221A
292 SF
20
ASSEM
15 SF
32"0.15 32"
STUDY LOUNGE
222
287
46"
0.15
43"
STAIR
ST002a
72
32"
0.2
32"
N HALL
H213A
MIN STAIR WIDTH REQ'D: 44"STAIR WIDTH PROVIDED: 48"
OCC LD = 65 OCC.MIN DOOR WIDTH REQ'D: 32"DOOR WIDTH PROVIDED: 32"
STAIR
ST004a
STAIR
ST001a
BED
268
BED
238
BED
242
BED
236
BED
234
BED
237
BED
241
BED
235
BED
233
BED
240
BED
239
BED
249
BED
254
BED
252BED
246
BED
248
BED
250
BED
245
BED
247
BED
262
BED
264
BED
263
BED
265
BED
266
BED
261
ITC
T207
BED
204
BED
203
BED
205
BED
216
HK
J209
BED
218
BED
206
BED-3
215 BED
217
BED
260
ACCESS BED
258
ELEC
T259
LAUNDRY
LOUNGE
200
W HALL
H213
BED
220
BED
219
BED
232
BED
231
BED
244
BED
243
BED - 4
251
BED
256
BED
267
LOBBY 2
H221
N HALL
H257
ELEV
E012
M
M204
M
M203
M
M215
M
M214
M
M218
M
M217
M
M231
M
M256
M
M251
M
M261
M
M262
M
M265
M
M266
BED
210
M
M210
BED
208
M
M208
BED
214
BED
212
291 SF
20
ASSEM
15 SF
32"0.15 32"
LOUNGE
221B
38'
198'
94' 214'
BED
202
BED
201
M
M201
M
M232
M
M236
M
M240
M
M235
M
M239
M
M244
M
M243M
M247
M
M248
M
M252
M
M260
FEC
FEC
FEC
FEC
ALIGN1-HR WALL PERVERTICAL &HORIZONTALCONTINUITY
1-HR WALLABOVE 1STFLOORFIRE WALL
4' - 0"
4' -
1"
TY
PC
OR
RID
OR
WID
TH
STAIR WIDTH4'-7" MIN
ST
AIR
WID
TH
4' -
0"
65
32"
0.15
32"
STAIR
ST001a
139
32"
0.15
32"
STAIR
ST004a
ST
AIR
WID
TH
'4'-0"
444 SF
30
ASSEM
15 SF
32"0.15 32"
LOUNGE-N
321C
LOBBY
H321
BED
319
235 SF
16
ASSEM
15 SF
32"0.15 32"
KITCHEN
321A
STAIR
ST004b
BED
368
BED
338
BED
342
BED
336
BED
334
BED
337
BED
341BED
335
BED
333
BED
340
BED
339
BED
349
BED
354
BED
352
BED
346
BED
348
BED
350
BED
345
BED
347
BED
362
BED
364
BED
363
BED
365
BED
366
BED
361
BED
360
ACCESS BED
358
ELEC
T359
BED
318
BED
305
BED
316
HK
J309
ITC
T307
BED
306
E HALL
H369LAUNDRY
LOUNGE
300
BED-3
315
M
M315
BED
317
BED
320
N HALL
H357
299 SF
20
ASSEM
15 SF
32"0.15 32"
STUDY LOUNGE
322
BED
367
STAIR
ST001b
ELEV
E012
STAIR
ST002b
BED
304
BED
303
BED
356
BED-4
351
BED
343
BED
344
BED
332
BED
331
M
M304
M
M303
M
M318
M
M317
M
M365
M
M366
M
M361
M
M362
M
M356
M
M351
M
M352
M
M348
M
M347
M
M343
M
M348
M
M340
M
M339
M
M332
M
M331
M
M335
M
M336
N HALL
H313A
BED
310
M
M310
BED
308
M
M308
BED
312
BED
314
M
M314
W HALL
H313
294 SF
20
ASSEM
15 SF
32"0.15 32"
LOUNGE
321B
94'
FIRE WALL
FEC
FEC
FEC
FEC
4' -
0"
1-H
R W
ALL
1-HR WALL PERVERTICAL &HORIZONTALCONTINUITY
ALIGN 4' - 0"1-HR WALLABOVE 1STFLOORFIRE WALL
ISSUING OFFICE: PROJECT NO:
KEY PLAN
654321
654321
A
B
C
D
E
NO DATE DESCRIPTION
NORTH
WEST
EAST
SOUTH
AB
12/13/17 75% CD0
12/1
2/2
017 2
:59:1
9 P
M
2ND-3RD FLR CODE PLAN
G-006
NEW RESIDENCE
HALL
75% CONSTRUCTION
DOCUMENTS
LAS CRUCES, NEW MEXICO 88003
LAS CRUCES 8919.17
RE
VIT
_v16
THIS DOCUMENT IS RELEASED ON12-13-2017 FOR THE PURPOSE OFINTERIM REVIEW UNDER THEAUTHORITY OF KIM M HOOKER,R.A., NEW MEXICO LICENSE #2828.IT IS NOT TO BE USED FORREGULATORY APPROVAL,CONSTRUCTION, BIDDING ORPERMIT PURPOSES.PARKHILL, SMITH & COOPER, INC.
1/16" = 1'-0"C1SECOND FLOOR - CODE PLAN
1/16" = 1'-0"A1THIRD FLOOR - CODE PLAN