DRAWING NO. TITLE CUSTOMER LOCATION JOB #
Page 1. of 3.
Air Heaters
B-12225 24" NDAH ( NAO Duct Air Heater ) Altair Filters International Altron, England 41941
Flow 500 SCFM Temp 1,652F 900C (1989)
Digital Temperature Control, Nema 12 Control
Panel, Piping Train, UV Flame Scanner,
Sightport, Direct Spark Ignition of Burner --
Low Fire Start then Temperature Modulation
B-9172 Hot Gas Generator ( Induced Draft ) Catalytic / FMC Lawrence, KS 18249
Horizontal Air Heater -- 3 Units (1979)Flow 700 SCFM Temp 1,155F 630C
Temperature Control with Thermocouple,
Nema 3 Control Panel, IRI Piping Train,
UV Flame Scanner, Sightport, Spark Ignited
Pilot, Pneumatic Temperature Modulation
C-7502 High Pressure Inline Heater -- 2 Units Industrial Electric-Automation Albuquerque, NM 49818Flow 5,250 SCFM Temp 550F 290C (1998 - 1983) 24354
Temperature / flame safeguard control and
pressure housing by customer.
BURNER / PILOT / IGNITOR by NAO.
High Energy Capacitor Discharge Ignition of
Pilot NOTE: High voltage transformer will
NOT spark above 30 psig (3 Atmospheres).
A-11635 Rev. 5 Direct Fired Air Heater - Horizontal Geosafe Los Alamos, NM 50669
Flow 3,600 SCFM Temp 160F 70C (1999)
Nema 4 Control Panel, Piping Train,
UV Flame Scanner, High Energy Capacitor
Discharge Spark Ignited Pilot, Low Fire Burner
Modulation
7/25/2019 NAO Air Heater Collection
9/15
DRAWING NO. TITLE CUSTOMER LOCATION JOB #
Page 2. of 3.
B-8336 Rev. 3 NAH-5CH12 ( NAO Horizontal Air Heater ) US Industrial Chemical Deerpark, TX 14631
Flow 2,000 SCFM Temp 1,900F 1,040C National Petrochemical Corp.
Temperature Control with Thermocouple, (1976)
Nema 7 (Explosionproof) Control Panel,
Burner/Pilot Gas Piping Trains, Air Blower,UV Flame Scanner, Sightport, Spark Ignited
Pilot, Pneumatic Air/Temperature Modulation
A-9180 Rev. 4 NHAH ( NAO Horizontal Air Heater ) Jacobs Engineering Compton, CA 42618
Flow 13,450 SCFM Temp 715F 380C (1989)
Skid Mounted Unit with Nema 4 (Weatherproof)
Control Panel, Temperature Control with TC,
Burner/Pilot Gas Piping Trains (Double Block &
Bleed per NFPA Code), Air Blower & Ducting,
UV Flame Scanner, Sightport, Spark Ignited
Pilot, Pneumatic Air/Temperature Modulation
A-8852 NHAH-23.2C10-HI (High Temp) Valero Refinery Corpus Christi, TX 41106
( NAO Horizontal Air Heater ) (1988)
Flow 29,800 Lb/Hr Temp 2,700F 1482C
Retractable Gas Burner/High Pressure Spark
Ignited Gas Pilot with Packing Glands &
Isolation Valves, Sightport. CONTROLS and
GAS TRAINS by customer.
A-9061 Rev. 4 NHDFAH-25C32 International Paper Georgetown, SC 42099
( NAO Horizontal Direct Fired Air Heater ) (1989)
Flow 13,000 SCFM Temp 1,400F 760C
High Turndown JET MIX Burner, Retractable
High Pressure Spark Ignited Gas Pilot with
Packing Gland & Isolation Valve, Self-Checking
UV Scanner, Sightport. OTHER CONTROLSand GAS TRAINS by customer.
7/25/2019 NAO Air Heater Collection
10/15
DRAWING NO. TITLE CUSTOMER LOCATION JOB #
Page 3. of 3.
A-11543 Rev. 3 NHDFAH-8C20 Preheater / Reheater Paramount Petroleum Georgetown, SC 50250
( NAO Horizontal Direct Fired Air Heater ) (1999)
Flow 77,266 Lb/Hr Flue Gas Temp 466F 230C
Combustion Air Blower with Flue Gas DilutionDuct (NOx Reduction), High Turndown JET
MIX Burner with Secondary Staged Fuel Tips
for NOx Reduction, High Pressure Spark Ignited
Gas Pilot , UV Scanner, Sightport.
OTHER CONTROLS and GAS TRAINS by customer.
A-9959 Rev. 5 NHDFAH-5.2C12 Celanese Mexicana Cangrejera, Mexico45068Sheets 1 & 2 of 2 ( NAO Horizontal Direct Fired Air Heater ) (1992)
Flow 54,091 Lb/Hr Waste Gas
Temp 800F 430C
Retractable Gas Burner/High Pressure Spark
Ignited Gas Pilot with Packing Glands &
Isolation Valves, Sightport, Air Purged Self-Checking
UV Scanner in Nema 7 (Explosionproof) Housing,Separate Control Skid with Nema 4 (Weatherproof)
Control Panel, Temperature Control with TC,
Burner/Pilot Gas Piping Trains (Double Block &
Bleed per NFPA Code), and Pilot Air Train
A-9200 Rev. 6 NHDFAH-5.2C12 ASME CODE Foster Wheeler / Fina Oil Port Arthur, TX 42659
Sheet 1 of 2 ( NAO Horizontal Direct Fired Air Heater ) (1989)Flow 545,936 Lb/Hr Temp 1,400F 760C
Cat Cracker Start-up Heater with High Turndown
JET MIX Burner, Retractable High Pressure
Spark Ignited Gas Pilot with Packing Gland &
Isolation Valve, Air Purged Sightports & Self-Checking
UV Scanner, Blast Connections for Removal of
Catalyst, Trunnion for Free Floating Support toAllow Thermal Expansion