G E P / G E P S Expander Plate

S E R I E S

Product Listings

• ANSI/UL1638Listed• CSFM:7300-0569:147

Product Compliance• NFPA72• IBC/IFC/IRC• City&StateOrdinances/Laws/ Regulations• QualityManagementSystemis certifiedto:ISO9001:2008

Standard Features• NominalVoltage24VDC• Lenscolorsavailable:amber,blue,greenandred• Amberlensmodelshavefieldselectablecandelaoptions:15,30,60,75,110• Blue,greenandredlensmodelsarefixed15/75candela• GEPdimension:10.8”(27.5cm)highx6.6”(16.8cm)widex2.8”(7.15cm)deep• GEPSdimension:11.5”(29.3cm)highx7.26”(18.45cm)widex 5.04”(12.8cm)deep• ALERTtextonallunits• Wallmounttoastandard4”(10.16cm)squarex2.125”(5.4cm)deepbackbox• GEPScanaccommodate1/2and3/4conduit• Screwterminals,separatein/outwiring(12-18gauge)• UseinconjunctionwithGentexspeakerorwallmountspeaker/strobe(SOLD SEPARATELY)• TosynchronizeusetheGentexAVSMControlModule• Wirestripguide• Faceplateavailableinoff-white• Xenonstrobemaintainsconstantflashrateoforat1Hz

Colored Lens Expander Plate Strobe SeriesApplicationsTheGentexGEPandGEPSSeriesisawallmountexpanderplatewithaqualitycoloredlensstrobetobeusedinconjunctionwithaGentexspeakerorwallmountspeaker/strobeallowingtheabilitytomountmultiplestrobesonasingleelectricalbox.Applicationsincludeemergencycommunication,severeweather,evacuation,emergencyresponseandmanymore.

TheGEPSeriesistobeusedinflushmountapplicationsandtheGEPSSeriesistobeusedinsurfacemountapplications.TheGEPandGEPSSeriesstrobesaredesignedtobeusedona24VDCsystemandareavailableinamber,blue,greenandredlenscolors.Theamberlensunitsareprovidedwithaturndialforfieldselectablecandelaoptions.Theblue,greenandredlensunitsareavailableinafixed15/75candelaoption.ThestrobescanbesynchronizedbyusingtheGentexAVSMControlModule,aswellasFACP’sorpowersuppliesthatincludetheGentexSynchronizationProtocol.AllunitsfeatureALERTtextonthelens.

TheGEPandGEPSSeriesareconstructedofhighimpacttexturedplastic.TheSeriesiswarrantedfor3yearsfromthedateofpurchaseandareANSI/UL1638listed.TheamberlensunitsadditionallycomplywiththelightoutputdispersionrequirementsofANSI/UL1971forwallmountapplicationswithameasuredcandelaratingthatisequaltothecandelalistedontheproduct.Noderatingwasrequired.

Lens available in Amber,Blue, Green and Red Colors

GEPGEPS

Model Number

Part Number

Lens Color

Nominal Voltage Candela(s)

GEPA 904-0510-002 Amber 24VDC 15,30,60,75,110

GEPB 904-0511-002 Blue 24VDC Fixed15/75

GEPG 904-0512-002 Green 24VDC Fixed15/75

GEPR 904-0513-002 Red 24VDC Fixed15/75

GEP/GEPS Blue, Green and Red Lens Strobe Current Ratings

Fixed 15/75* Candela Strobe

Lens Color UL Max.1 Operating Current (mA)

Blue 280

Green 360

Red 397

Amber Lens Strobe Candela Ratings

Use with GEPA and GEPAS

CandelaANSI/UL 1638

On-Axis Candela Rating

ANSI/UL 1971 Measured Candela Rating, Wall Mount

15 15 15

30 30 30

60 60 60

75 75 75

110 110 110

GEP/GEPS Amber Lens Strobe Current Ratings

Candela UL Max.1 Operating Current (mA)

15 78

30 96

60 137

75 180

110 224

NOtICE:PerNFPA72,coloredstrobesaretobelistedtoANSI/UL1638.ANSI/UL1971isnotapplicabletocoloredlensdevicesusedinemergencycommunicationinstallations.However,thelistedreadingswereobtainedusingthelightoutputdispersionmeasurementrequirementsunderANSI/UL1971.

GEP Series Flush Mount Expander Plate

GEPS Series Surface Mount Expander Plate Model

NumberPart

NumberLens Color

Nominal Voltage Candela(s)

GEPAS 904-0514-002 Amber 24VDC 15,30,60,75,110

GEPBS 904-0515-002 Blue 24VDC Fixed15/75

GEPGS 904-0516-002 Green 24VDC Fixed15/75

GEPRS 904-0517-002 Red 24VDC Fixed15/75

Model Designations:• Allmodelsaredesignedforwallmountapplications• Allmodelsavailableinwhitefaceplate• AllmodelsincludeALERTtext LensColors: A=Amber B=Blue G=Green R=Red

NOtES:• Operatingtemperature32oto120oF(0oto49oC). TheGEP/GEPSSeriesisnotlistedforoutdoor use.• FornominalandpeakcurrentacrossANSI/UL regulatedvoltagerangeforfilteredDCpowerand unfiltered(FWR(FullWaveRectified))power,see installationmanual.• Gentexdoesnotrecommendusingacoded orpulsingsignalingcircuitwithanyofourstrobe products(seeTechnicalBulletin014).• TheGEP/GEPSSeriesisnottobeusedasa visualpublicmodealarmnotificationappliance.1 RMScurrentratingsareperANSI/ULaverage RMSmethod.ANSI/ULmaxcurrentrating isthemaximumRMScurrentwithinthelisted voltagerange(16-33VDCfor24VDCunits). ForstrobestheULmaxcurrentisusuallyat theminimumlistedvoltage(16VDCfor24VDC units).ForunfilteredFWRratings,see installationmanual.

* TheGEPB,GEPG,GEPR,GEPBS,GEPGS,GEPRS hasafixedcandelaratingof15/75perANSI/UL1638.

Candela Selection: GEPA and GEPAS Only

Adjustintensitybyinsertingsmallflatbladetoturndial.Displayednumberwillindicateselectedcandela.

Additional Mounting Notes:

• Attachspeakerorspeaker/strobeusing themountingring• Levellineistoaidinalignmentduring installation• Includeswirestripguide• Includesfourbaselocationsfor additionalscrewsupport,ifneeded.

Installation GEP Flush Mount Expander Plate Mounting Ring with Key Location

Installation GEPS Surface Mount Expander Plate

ImportantNotice:

ThesematerialshavebeenpreparedbyGentexCorporation(“Gentex”)forinformationalpurposesonly,arenecessarilysummary,andarenotpurportedtoserveaslegaladviceandshouldnotbeusedassuch.Gentexmakesnorepresentationsandwarranties,expressorimplied,thatthesematerialsarecompleteandaccurate,up-to-date,orincompliancewithallrelevantlocal,stateandfederallaws,regulationsandrules.Thematerialsdonotaddressalllegalconsiderationsasthereisinevitableuncertaintyregardinginterpretationoflaws,regulationsandrulesandtheapplicationofsuchlaws,regulationsandrulestoparticularfactpatterns.Eachperson’sactivitiescandifferentlyaffecttheobligationsthatexistunderapplicablelaws,regulationsorrules.Therefore,thesematerialsshouldbeusedonlyforinformationalpurposesandshouldnotbeusedasasubstituteforseekingprofessionallegaladvice.Gentexwillnotberesponsibleforanyactionorfailuretoactinrelianceupontheinformationcontainedinthismaterial.

GEP050113-AAA

G E P / G E P S Expander Plate

S E R I E S

END OF LINERESISTOR

+_

+_

END OF LINERESISTOR

+ _ + _

+_

END OF LINERESISTOR

+ _

TO NEXT APPLIANCE

TO NEXT APPLIANCE

TO NEXT APPLIANCE

FROM LAST APPLIANCE

FROM LAST APPLIANCE

FROM LAST APPLIANCE

SPEAKERSTROBE(OPTIONAL)

STROBE

SPEAKER25 OR 70.7 VRMs

SOURCE

SOURCE

STROBE24 VDC POWER

SOURCE

GENTEX GEP24 VDC POWER

Wiring Diagram

Architect & Engineering Specifications TheexpanderplateshallbeGentexGEPorGEPSColoredLensExpanderPlateorapprovedequivalentandshallbelistedbyUnderwritersLaboratories,Inc.perANSI/UL1638andtheamberlensproductshallhavecompliancewiththepolardispersionrequirementsofANSI/UL1971.TheGEPorGEPSshallalsobelistedwiththeCaliforniaStateFireMarshal(CSFM)andcomplywithalllocal,stateandfederalfirealarmcodes/standards.Thevisualsignalshallhaveaminimum1Hzflashrateregardlessofinputvoltage.Theunitshallhaveaninputvoltagerangeof16-33voltswitheitherdirectcurrentorfullwaverectifiedpowerfor24voltmodels.Allfieldwiringconnectionsshallbemadeviaseparatein-outterminalconnections.

• Allstrobesaredesignedtoflashasspecifiedwithcontinuousappliedvoltage.Strobesshouldnotbeusedoncodedorpulsing signalingcircuits.However,useoftheGentexAVSMcontrolmoduleorGentexsynchronizationprotocolispermittedto synchronizethestrobe,hornand/ormutethehorn.SeeTechnicalBulletin014foradditionalinformation.• FOR SYNCHRONIZAtION WIRING INFORMAtION, REFERENCE AVSM CONtROL MODULE DAtA SHEEt (551-0031) AND/OR AVSM CONtROL MODULE MANUAL (550-0284) FOR SYNCHRONIZAtION MODULE WIRING DIAGRAMS. AVSM CONtROL MODULE DAtA SHEEt AND MANUAL CAN BE OBtAINED At HttP://WWW.GENtEx.COM OR CALL GENtEx CORPORAtION At 1-800-436-8391.

*MAX.WIREDISTANCE(INFEET)= XWIRECONDUCTIVITY(STROBEONLY)PANELVOLTAGE-DEVICEMINIMUMVOLTAGETOTALCURRENTDRAW

* INCLUDESWIRETOANDFROMAPPLIANCE.ASSUMESALLAPPLIANCES AREATTHEENDOFWIRERUN(WORSTCASE).NOTICE:APPLIESONLY TOREGULATEDSUPPLIES.

WIRECONDUCTIVITY18AWG 6016AWG 9514AWG 15312AWG 244

NOTICE:SPEAKERORSPEAKER/STROBEUSEDWITHGEPORGEPSMUSTBEORDEREDSEPARATELY.

CAUTION:DONOTUSELOOPEDWIREUNDERTERMINALS.BREAKWIRERUNTOPROVIDESUPERVISIONOFCONNECTION.

GEPSeries12unitspercarton12poundspercarton