Challenges of implementing a reliable and accurate non ...

Post on 15-May-2022

3 views 0 download

Transcript of Challenges of implementing a reliable and accurate non ...

1

Challenges of implementing a reliable and accurate non-intrusive ultrasonic

flow measurement on penstocks at large-scale hydroelectric power

plants

Denis Funk

FLEXIM GmbH

2

3

4

1 Introduction of ultrasonic clamp-on (USCO) flow measurement: Transit-time technology

Challenges and experiences of a manufacturer implementing USCO flowmeters on penstocks of hydroelectric plants

Selection of transducers

Agenda

2

2.1

5

2.2 Mounting and coupling

Ambient temperature fluctuations

Verification of the correctness and checkup of the long-term stability of the measurement

2.3

3

6

Flow

Cross section of the pipe

Fluidmechanic Calibration factor

Acoustic Calibration factor

time difference

transit time in the fluid

Re

2a

fl

tV A K K

t

∆= ⋅ ⋅ ⋅&

t∆

lv

UFM

Re

a

fl

V

A

K

K

t

t

&

flt

1. Introduction of ultrasonic clamp-on (USCO) flow measurement: Transit-time technology

7

1. Introduction of ultrasonic clamp-on (USCO) flow measurement: Transit-time technology

8

2.1 Selection of transducers

9

Lambwave

2.1 Selection of transducers

Shearwave

10

2.2 Mounting & coupling

11

• Welded

transducer

mounting

• Robust

• Tamper proof mounting

• Long-term stable

2.2 Mounting & coupling

12

2.3 Ambient temperature fluctuations

13

ASME MFC-5.1-2011:

• 4. Uncertainty sources and

uncertainty reduction

“…the flow velocity is calculated

from the transit times; the

sound speed and the angle in

the coupling wedge. A

temperature influence from

temperature dependency of the

sound speed, c, may be

compensated for.”

2.3 Ambient temperature fluctuations

Piezo sensor

Piezo sensorTemperature sensor

Temperature sensor

14

3. Verification of the correctness and checkup of the long-term stability of the measurement

Self-diagnostics

15

Thank you for your attention!

Denis FunkHead of Market Management Power Generation

FLEXIM GmbH dfunk@flexim.de

16

Backup

17

Pipe wall penetrationMulti reflection

2.1 Selection of transducers

Pipe wall resonance

2.1 Selection of transducers