Easy, reliable, accurate: Dose Area Product meters by...

8
Easy, reliable, accurate: Dose Area Product meters by PTW DIAMENTOR ® Systems by PTW PTW is setting a worldwide standard with the DIAMENTOR systems for patient dosimetry in diagnostic radiology. PTW-France PTW-France PTW-New York PTW-New York Australia Australia and New Zealand Europe Austria Belarus Belgium Bulgaria Cyprus Czech Republic Denmark Finland France Germany Greece Hungary Iceland Italy Malta Netherlands Norway Poland Portugal Romania Russia Slovakia Spain Sweden Switzerland Turkey Ukraine United Kingdom Asia Bahrain Bangladesh China Hong Kong India Indonesia Iran Israel Japan Jordan Korea Lebanon Malaysia Pakistan Philippines Saudi Arabia Singapore Syria Taiwan Thailand Vietnam Colombia Costa Rica Ecuador Mexico Panama Uruguay USA Venezuela Africa Egypt Morocco South Africa America Argentina Brazil Canada Chile PTW-Freiburg PTW-Freiburg PTW-Latin America PTW-Latin America PTW-China PTW-China Physikalisch-Technische Werkstätten Dr. Pychlau GmbH PTW-Freiburg Lörracher Strasse 7 79115 Freiburg · Germany Phone +49 761 49055-0 Fax +49 761 49055-70 [email protected] www.ptw.de PTW-New York Corporation 201 Park Avenue Hicksville · New York 11801 Phone (1-516) 827 3181 Fax (1-516) 827 3184 [email protected] www.ptwny.com PTW-France SARL 41 Chemin de la Cerisaie 91620 La Ville du Bois · France Phone +33 1 64 49 98 58 Fax +33 1 69 01 59 32 [email protected] www.ptw-france.com PTW reserves the right to modify the design and specifications contained herein without prior notice. Please contact PTW or your local representative for the most current information. D150.139.0/0 200602-3B Printed on cellulose bleached by a non-polluting method. PTW-Latin America Av. Evandro Lins e Silva 840 Sala 2018 · Barra da Tijuca 22631-470 Rio de Janeiro-RJ · Brazil Phone +55 21 2178 2188 Fax +55 21 2429 6234 [email protected] www.ptw.com.br PTW-China Unit 2018, 20/F., Shatin Galleria 18-24 Shan Mei Street, Fotan, N.T. Hong Kong Phone +852 3156 4991 Fax +852 3156 4992 [email protected] www.ptw-china.com

Transcript of Easy, reliable, accurate: Dose Area Product meters by...

Page 1: Easy, reliable, accurate: Dose Area Product meters by PTWscanrad.no/radiologi/kvalitetssikring/.../300/Diamentor_brochure.pdf · Easy, reliable, accurate: Dose Area Product meters

Easy, reliable, accurate:Dose Area Product meters by PTW

DIAMENTOR® Systems by PTWPTW is setting a worldwide standard with the DIAMENTOR systems for patientdosimetry in diagnostic radiology.

PTW-FrancePTW-France

PTW-New YorkPTW-New York

AustraliaAustralia andNew Zealand

EuropeAustriaBelarus BelgiumBulgariaCyprusCzech Republic

DenmarkFinlandFranceGermanyGreeceHungaryIcelandItalyMaltaNetherlandsNorway

Poland PortugalRomaniaRussiaSlovakiaSpainSwedenSwitzerlandTurkeyUkraineUnited Kingdom

AsiaBahrainBangladeshChinaHong KongIndiaIndonesiaIranIsraelJapanJordan

KoreaLebanonMalaysiaPakistanPhilippinesSaudi ArabiaSingaporeSyriaTaiwanThailandVietnam

ColombiaCosta RicaEcuadorMexicoPanamaUruguayUSAVenezuela

AfricaEgyptMoroccoSouth Africa

AmericaArgentinaBrazilCanadaChile

PTW-FreiburgPTW-Freiburg

PTW-Latin AmericaPTW-Latin America

PTW-ChinaPTW-China

Physikalisch-Technische WerkstättenDr. Pychlau GmbH

PTW-FreiburgLörracher Strasse 779115 Freiburg · GermanyPhone +49 761 49055-0Fax +49 761 [email protected] www.ptw.de

PTW-New York Corporation201 Park AvenueHicksville · New York 11801Phone (1-516) 827 3181 Fax (1-516) 827 [email protected]

PTW-France SARL41 Chemin de la Cerisaie91620 La Ville du Bois · France Phone +33 1 64 49 98 58Fax +33 1 69 01 59 [email protected]

PTW reserves the right to modify the design and specifications contained herein without prior notice. Please contact PTW or your local representative for themost current information.

D150.139.0/0 200602-3BPrinted on cellulose bleached by a non-polluting method.

PTW-Latin AmericaAv. Evandro Lins e Silva840 Sala 2018 · Barra da Tijuca22631-470 Rio de Janeiro-RJ · BrazilPhone +55 21 2178 2188 Fax +55 21 2429 [email protected]

PTW-ChinaUnit 2018, 20/F., Shatin Galleria18-24 Shan Mei Street, Fotan, N.T.Hong KongPhone +852 3156 4991Fax +852 3156 [email protected]

Page 2: Easy, reliable, accurate: Dose Area Product meters by PTWscanrad.no/radiologi/kvalitetssikring/.../300/Diamentor_brochure.pdf · Easy, reliable, accurate: Dose Area Product meters

Easy to use: The user friendly design of the DIAMENTOR devices byPTW-Freiburg ensures easy handling. Optimally coordinatedcomponents enable the user to install the systmes convenientlyand fast.

Knowing what responsibility means:

Accurate: PTW-Freiburg is the pioneer of the DAP meter. DIAMENTOR measuring systems are top-rate German products for radiation protection,which have been supplied in quantities of many thousands to satisfiedcustomers.

Reliable: PTW-Freiburg DAP meters are the most reliable DAP meters onthe market. The fact that DIAMENTOR systems installed 30 years ago arestill working accurately documents the unique reliability of productsfrom PTW-Freiburg.

DIAMENTOR® is a registered trademark of PTW-Freiburg

What is the dose area product (DAP)?

The DAP is the result of the multiplication of the entrance dose (air kerma)and the area of the beam. It can be measured by a flat ionization chamberwhich is mounted directly to the light beam housing between the X-rayfocus and the patient surface. Following the inverse square law, the DAPis independent of this distance between focus and patient.This relationship indicates that doubling the distance between a radiationsource and a measuring chamber increases the radiation area by a factorof four, while the dose (air kerma) decreases simultaneously by a factor offour. Both effects cancel out each other. Therefore the dose area productis independent of the distance and it determines in an elegant way allvariable parameters like tube voltage, tube current, filtration, irradiationtime and field size during an examination.

Page 3: Easy, reliable, accurate: Dose Area Product meters by PTWscanrad.no/radiologi/kvalitetssikring/.../300/Diamentor_brochure.pdf · Easy, reliable, accurate: Dose Area Product meters

PTW DIAMENTOR systems are setting a worldwide standard

4 5

There is no interference with routine work, since the ionization chambers are firmly mounted to the collimator.

The highly transparent ionization chambers ensure proper operation of the light system.

Optimally coordinated components enable convenient and fast installations.

Fast calibration and constancy checks can be performed by means of a built-in test function.

Easy and uncomplicated RIS or HIS connection can be realized straightforward via the RS232 interface.

The user friendly design of the devices ensures easy handling.

Uncomplicated and easy evaluation of the total amount of radiation applied to patients.

For more than 40 years, PTW-Freiburg has worked success-fully in developing and manufacturing DAP meters for dia-gnostic radiology, which are manufactured in line with thestrictest quality standards and completely fulfill therequirements of IEC 60580 and FDA 21 CFR Part 1020.

Application areas:

radiography

fluoroscopy

angiography, DSA, cardiological series

interventional radiography

What are the advantages of a DIAMENTOR system?

[1] Council Directive 97/43/EURATOM of 30 June 1997 on health protection of indi-viduals against the danger of ionizing radiation in relation to medical exposure[2] USA Food and Drug Administration (FDA), Federal Register Part III, Departmentof Health and Human Services – 21 CFR Part 1020 (Electronic Products; Performan-ce Standard for Diagnostic X-Ray Systems and Their Major Components; Final Rule)[3] IEC 60580 Medical electrical equipment – Dose area product meters

The use of radiation in medicine is of great value,but it contributes by far the greatest part of the man-maderadiation dose. Especially diagnostic radiology delivers thehighest share of radiation exposure to the population.

Radiation protection procedures are therefore mandatory in many countries such as the countries of the European Community and the USA. A European Directive requires the“assessment and evaluation of patient doses” [1]. Accordingto a publication of the Food and Drug Administration (FDA)[2], fluoroscopic equipment manufactured on or after June10, 2006, must display at the fluoroscopist’s working positionthe air kerma rate (AKR) and the cumulative air kerma.According to clause 1020.32(k) of this publication, a fluoro-scopic air kerma display device signifies a device that providesthe display of AKR and the cumulative air kerma – such asthe DIADEM patient dosemeter from PTW-Freiburg.

Diagnostic The use of radiation in medicine is of great value,but it contributes by far the greatest part of the man-maderadiation dose. Especially diagnostic radiology delivers thehighest share of radiation exposure to the population.

Radiation protection procedures are therefore mandatory in many countries such as the countries of the European Community and the USA. A European Directive requires the“assessment and evaluation of patient doses” [1]. Accordingto a publication of the Food and Drug Administration (FDA)[2], fluoroscopic equipment manufactured on or after June10, 2006, must display at the fluoroscopist’s working positionthe air kerma rate (AKR) and the cumulative air kerma.According to clause 1020.32(k) of this publication, a fluoro-scopic air kerma display device signifies a device that providesthe display of AKR and the cumulative air kerma – such asthe DIADEM patient dosemeter from PTW-Freiburg.

Dose area product (DAP) meters and dosemeters, firmlyinstalled to the X-ray unit, make it possible to determine theradiation load to which patients are exposed during X-rayexaminations. The exposures can be reduced by a measuringdevice informing the practitioner of the total amount ofradiation applied to the patient. Especially high dose andhigh risk X-ray examinations such as fluoroscopy require adevice to determine the radiation exposure to patients.

Measuring devices of the DIAMENTOR series and the DIADEMpatient dosemeter provide for patient dosimetry solutionscovering every application and budget and help to protectpatients against the risk of radiation exposure in medicaldiagnostic radiology.

Page 4: Easy, reliable, accurate: Dose Area Product meters by PTWscanrad.no/radiologi/kvalitetssikring/.../300/Diamentor_brochure.pdf · Easy, reliable, accurate: Dose Area Product meters

DIAMENTOR® E2 DIAMENTOR® C2 DIAMENTOR® M4

DIAMENTOR systems

specially suitable for mobile and stationaryinstallations

perfect for C arms

perfect for stationary installations

simultaneous DAP measurement on twodifferent X-ray installations are possible(perfect if the control desk is the same)

prized for biplane angiography

suitable for stationary installations

prized for biplane angiography

T11033 consists of:

DIAMENTOR E2

T11038AP consists of:

DIAMENTOR C2 with a printer

T11038A consists of:

DIAMENTOR C2 without printer

T11024 consists of:

DIAMENTOR M4

Wall fixation parts

bright LED display

easy connection to a RIS or HIS via theinternal RS232 interface

well-priced system

multifunctional dual channel DAP meter

separate channels; separate value printingand separate resetting is possible

easy connection to a RIS or HIS via theinternal RS232 interface

with or without internal printer available

multifunctional dual channel DAP meter

easy connection to a RIS or HIS via the internal RS232 interface

secondary display can be connected on demand

... have a DIAMENTOR solution with an internal printer and with theopportunity to connect two ionizationchambers?

... have a DIAMENTOR solution wheretwo ionization chambers can be connected?

... have a well-priced and flexibleDIAMENTOR solution with integratedelectronics and display unit for connecting one ionization chamber?

6 7

DIAMENTOR® CX DIAMENTOR® Set CI DIAMENTOR® Set CMcompact DAP meter with a bright LEDdisplay

fast and simple installation

easy connection to a RIS or HIS via anoptional RS232 module

integrated electronics

flexible LED display positioning

easy connection to a RIS or HIS via an optional RS232 module

well-priced system

flexible positioning of the small electronics

flexible LED display positioning

easy connection to a RIS or HIS via an optional RS232 module

well-priced system

specially suitable for mobile andstationary installations

display can be fixed arbitrary electronics can be hidden behind the hou-sing of the X-ray installation

display can be fixed arbitrary e.g. next tothe control desk

L981961 consists of:

DIAMENTOR CX

Power supply

L981196 consists of:

DIAMENTOR CI

DIAMENTOR CD display

Power supply

Extension cable

L981197 consists of:

DIAMENTOR CM

DIAMENTOR CD display

Ionization chamber B

Power supply

Extension cable

Application

Ordering Information

„... have an "all-in-one" DIAMENTORsystem with integrated ionizationchamber, electronics and display unit?

... have a well-priced DIAMENTORsystem with a separate display unitbut integrated electronics and ionization chamber?

... have a well-priced DIAMENTORsystem with a separate ionizationchamber type B, a separate displayunit and separate electronics?

Find out which DIAMENTOR system is the right one. Would you like to ...

yes

no

yes yes yes yes yes

no no no no no

Page 5: Easy, reliable, accurate: Dose Area Product meters by PTWscanrad.no/radiologi/kvalitetssikring/.../300/Diamentor_brochure.pdf · Easy, reliable, accurate: Dose Area Product meters

DIAMENTOR® M4-KDK DIADEM® DIAMENTOR®

built-in solution

suitable for stationary installations

exquisite for applications where dose anddose rate values are also required

specially suitable for mobile and stationaryinstallations

circular ionization chambers for C arms areavailable

narrow ionization chambers for mobile application are available

well-priced, non-transparent ionizationchambers for under couch tubes are available

T11039 consists of:

DIADEM

Built-in DIAMENTOR DAP meters uponrequest!

Please contact us!

measures simultaneously DAP, DAP rate,dose and dose rate

special KDK chamber with two measuringareas

easy connection to a RIS or HIS via theinternal RS232 interface

secondary display can be connected ondemand

fulfills the requirements acc. to FDA 21 CFRPart 1020

measures simultaneously dose and doserate

fullfills the requirements acc. to FDA 21CFR Part 1020

different built-in DIAMENTOR DAP metersare available, which have been developed incooperation with well known manufacturersof X-ray installations

many different ionization chambers areavailable

“...have a device that measures theDAP, the DAP rate as well as the dose,the dose rate and the irradiation timevia an ionization chamber directlymounted to the collimator?

...have a device that measures only the dose and dose rate via an ionizationchamber directly mounted to the collimator?

...have a built-in solution?

8

yes yes yes

no no

overview

T11025 consists of:

DIAMENTOR M4-KDK

Wall fixation parts

Page 6: Easy, reliable, accurate: Dose Area Product meters by PTWscanrad.no/radiologi/kvalitetssikring/.../300/Diamentor_brochure.pdf · Easy, reliable, accurate: Dose Area Product meters

Technical dataDIAMENTOR in combination with a standard B chamber M4-KDK DIADEM with

CX CI CM E2 C2 M4 with KDK chamber DIADEM chamber

Product Channels one channel device dual channel device one channel device one channel device

Measuring unit DAP [µGym2] X X X X X X X

DAP rate [µGym2/s] X X X X X X X

Dose [mGy] X X

Dose rate [mGy/s] X X

Irradiation time [s] X X

Measuring range DAP (0.1 ... 99 999 999) µGym2 (0.1 ... 999 999) µGym2

DAP rate (0.1 ... 15 000) µGym2/s (0.1 ... 30 000) µGym2/s

Dose (0.01 ... 10 000) mGy (0.1 ... 99 999 999) mGy

Dose rate (0.01 ... 999 999) mGy/s (0.1 ... 15 000) mGy/s

Irradiation time 1s ... 999 min

Digital resolution DAP 0.01 µGym2

DAP rate 0.01 µGym2/s

Dose0.001 mGy for (0.01... 999 999) mGy

0.01 mGy1 mGy for (1000 ...10 000) mGy

Dose rate 0.001 mGy/s 0.01 mGy/s

Irradiation time600 ms (Dose rate > 2.4 µGy/s) 60 ms (Dose rate > 12 µGy/s)

Ranges of use DAP rate (0.01 ... 15 000) µGym2/s (0.005 ... 30 000) µGym2/s

Dose rate: (0.005 ... 15 000) mGy/s

Tube voltage (50 ... 150) kV

Temperature (10 ... 40) °C

Air density* (10 ... 80) %, max. 20 g/m3

Display LED LCD LED

Power supply 24 VDC ± 10%(100 ... 240) VAC, 230 V / 115 V

(50 ... 60) Hz AC voltage 24 VDC ± 10%

Dimension [H x W x D] 164 x 209 x 18 mm3 164 x 220 x 18 mm3 52 x 72 x 22 mm3 36 x 83 x 151 mm3 104 x 264 x 186 mm3 71 x 225 x 198 mm3 36 x 83 x 151 mm3

Weight 325 g 330 g 105 g 250 g 1180 g 2100 g 250 g

Do you have any other questions?Please contact us!

*without condensation

> 0.04 µGym2 / s: 600 ms> 0.2 µGym2 / s: 60 ms

Page 7: Easy, reliable, accurate: Dose Area Product meters by PTWscanrad.no/radiologi/kvalitetssikring/.../300/Diamentor_brochure.pdf · Easy, reliable, accurate: Dose Area Product meters

DIAMENTOR accessories installation

(Distance) adaptation rails(distance) adaptation rails can be screwed directly to the ionizationchamberdistance adaptation rails facilitate the use of fade out filtersUniversal holdereasy and flexible handlingadjustment of rail distances between 133 mm and 177 mm arepossibleoptional rails for the use of ovarian filters are availableallows the correct arrangement of any filter and the chamberwithout influencing the measurementPediatric filterstransparent filters for reducing the patient entrance dose duringpediatric X-ray examinationdifferent filter sizes with different beam hardening values are availabledo not influence the light fieldExternal printersused in combination with a DIAMENTOR M4-KDK, M4, E2 andDIADEMprinting is automatically controlled by the DIAMENTOR unitconnection via the RS232 interface

Secondary displayfor use with a DIAMENTOR M4-KDK or M4 flexible positioningbright LCD display

DiaSoft softwarefor use with a DIAMENTOR M4-KDK, M4 or C2calculates the effective dose and the organ doses from the DAPpresents the results as a function of time graphicallyPower limitationideal for mobile installations, which fulfill IEC 60601-1operation with 24 Vfor use with a DIAMENTOR CX, CI, CM or E2small and convenient solution

CE marked

Extension cabledifferent lengths are availablenormally a 15 m extension cable is sufficient

Installation

Run the extension cable

Connect the power supply

Put the chamber into the rails of the collimator

Connect the components

Make at least a test measurement

DAP installations: quick and easy with PTW DIAMENTORsystems, also on C-arms and mobile X-ray installations

10 11

secondary display

printer pediatric filters attach chamber

insert universal holder

connect components built-in solution

Make a test measurement

Page 8: Easy, reliable, accurate: Dose Area Product meters by PTWscanrad.no/radiologi/kvalitetssikring/.../300/Diamentor_brochure.pdf · Easy, reliable, accurate: Dose Area Product meters

Knowing what responsibility means:

12 13

In 1922, twenty-seven years after Röntgen discovered X-rays, Professor Hammer from the Physics Institute of Freiburg University founded PTW to produce and markethis development of an X-ray dosemeter based on an electrostatic relay, a revolutionary new electromechanicalcomponent for measuring very small electrical charges.

In 1927, Dr. Herbert Pychlau took over the company anddeveloped it during four decades into an internationallyrecognized manufacturer of quality dosemeters for medicalradiology.

During the second half of the 20th Century, the businessgrew into an acknowledged international company, acquiring a good reputation as a pioneer with both scientists and users.

PTW-Freiburg’s production area, which in the very beginning was located in Professor Hammer’s gardenshed, covers a total area of 4000 m2 today. PTW employs a staff of 200 all over the world. The company, which scores steady growth, is the recognized market leader in medical dosimetry today.

We at PTW constantly strive to be competent and reliablepartners for our customers all over the world, which includes maintaining demanding quality standards aswell as comprehensive service and support standards. We will continue our efforts to develop the most reliableand highest quality dosimetry products in the future aswe have in the past, products in which users and patientsput their trust.We are committed to upholding this trust, because weknow what responsibility means.

The Directors Dr. Christian Pychlau and Dr. Edmund Schületogether with Günter Hein, Director of Sales and Marketing(from left).