Swing Door Operator
DORMA ED 200
Door parameters DORMA ED 200
2
Swing Door Operator DORMA ED 200
As a powerful fully automaticelectro-hydraulic swing dooroperator, the DORMA ED 200is suitable both for standarddoors and also for large and heavy doors. It can beadapted to a wide range ofdifferent applications andinstallation conditions, andoffers numerous adjustablefeatures.With the integrated perma-nent-open mode activated,the door is held open by asolenoid valve in a mannerwhich ensures absolutestability and operatingsilence.The sound-insulated Softlinecover can be extended tothe full width of the dooropening for maximum visualattractiveness.
The DORMA ED 200 –available up to size EN 7 –is also suitable for fire andsmoke rated doors, evenwith its permanent openfunction. It can also beinstalled in emergency exitsand escape routes providedthat it is controlled by anappropriate emergency exitsecurity control system. It can likewise be combinedwith access control systems.
Universal operator – easy to install, reliable in operation
– Two models (EN 4-6,EN 7)to suit all applications
– One model for both doordirections and fixing positions (pull side/pushside)
– Quick and easy to fixthanks to two auxiliaryscrews and plug-connected cabling
– Reliable function even inthe case of heavy-use doorsand entrances exposed tovarious weather conditions
– Optimum adaptability toindividual requirements –e.g. in hospitals, homesfor the elderly, facilitiesfor the disabled,restaurants, security areas and laboratories
– Numerous control options
– Also available with enhanced control systemfor additional functions
DIN18263/T4
Standard doors– Single-leaf x– Double-leaf x
Fire and smoke rated doors– Single-leaf x– Double-leaf x
Door leaf width (including fire and smoke rated doors), max. 1400 mm
Door leaf weight (including fire and smoke rated doors), max. 250 kg
Opening angle, max. 115°
Lintel depth (standard arm) – 40 to 360 mm
Features and benefits
7
2
6
1
5
3
4
115° 75°
25°
3
1 Adjustable opening speed2 Adjustable backcheck1 + 2 Adjustable opening time3 Adjustable closing speed4 Adjustable delayed closing action3 + 4 Adjustable closing time5 Easy manual operation with bypass valve6 Backcheck range for manual operation7 Adjustable door opening angle,
adjustable hold-open time
Functions and adjustment possibilities
Technical data
Adjustable closing force Size EN 4 – 6
Fixed closing force setting Size EN 7
DIN left/DIN right x
Width (standard) 665 mm
Height 106 mm
Overall depth 133 mm
Weight 18 kg
Standard arm y
Slide channel arm*– sound-insulated y– slimline design y
Power consumption, max. 250 W
Power supply data 230 V,50/60 Hz
External power supply 12 V AC,12 – 24 V DC
– 800 mA (AC), 400 mA (DC) x– 1500 mA (AC), 800 mA (DC) v
Degree of protection IP 20
Type approved by the German Technical Inspectorate (TÜV) x
Tested and approved in accordance with the low voltage directives (CE) x
Quality-assured manufacture to ISO 9000 x
* Not approved for use with fire and smoke check doors
Drive unit and control
Microprocessor control x
Function programs– Off x– Automatic x– Permanent open x– Exit only v– Night-bank facility v– Push-and-Go X
De-energised or switched off = Door closer function x
Adjustable opening time ≥ 1.5 sAdjustable closing time ≥ 3 sAdjustable hold-open time 0 – 30 s
Adjustable backcheck x
Adjustable delayed closing action x
Connection for infra-red safety sensors for pull and push side x
Connection for electro-mechanical door lock x
Connection for electric strike plate x
Connection for access control system x
Prepared for double doors x
Module for connection to EIB building control system X
Control options
Connections for two different activators v
Connection for smoke detector x
Power supply for smoke detector, 24 V DC, 100 mA, stabilised v
Connection for DORMA SVP emergency escape motor lock with automatic locking action v
Activation via radio remote control X
Shutdown of the push-side infra-red sensors when door closed v
Additional power supply unit, SM 201 for 12/24 V, 1.5 A X
Accessories
Continuous or extended cover X
Infra-red safety sensor DORMA IRS 70, 90 or 120, on the pull side X
Infra-red safety sensor DORMA IRS 35 on the push side X
Smoke detector DORMA RMZ 2 X
Smoke detector DORMA RM X
Door co-ordinator DORMA G 93 GSR X
Electric strike plate (fail-secure principle) X
x standard X accessory y optionv only in conjunction with comfort control system
6462.5
508.564
15
280
315 50
38
5.5
10
6
665
36
4
DORMA ED 200 for single doors
Fixing on the push side (not approved for fire and smoke check doors)
30
17
12 4
7 23
175280
586
10
6
64
36
62.5508.5
64
15
665
Fixing on the pull side (not approved for fire and smoke check doors)
20
10
6
64
36
57.5503.5
64
665
250
350
30
17 12 4
7
586
600
Push-side fixing
for LH and RH doors(Example shows RH door)
for LH and RH doors(Example shows LH door)
for LH and RH doors(Example shows RH door)
X
133
10 A
5 6 8 9 4 10
3
2
1
ED 200
2 x
0.8
4 x
0.8
4 x
0.1
4
4 x
0.1
4
2 x
0.8
2 x
0.8
3 x 1.5
L1 NPE
2 x 0.8
11
7
5
Lintel depth X Standardarm
–40 to 120 mm 0180 to 240 mm 02
240 to 360 mm 031) Optional spindle extension
133
133
Connections
01 Power supply line: 230 V, 50/60 Hz
02 Emergency stop pushbuttonto DIN VDE, mounted close
to the door
03 Two-pole-and-earth socket,by others; if no socket to be
used, lockable main switch
to be fitted by others
04 External program switch,optional with standard
control (3-position),
necessary with comfort
control unit (4-position);
cable length max. 100 m
05 Pushbutton/switch, internal06 Pushbutton/switch, external07 Electric strike plate08 Activator, internal09 Activator, external10 Key switch11 DORMA ED 200 Lintel depth Slide channel,
push actionOn request Sound-
insulatedSlimline
Connections
1)
1)
1) Optional spindle extension
1)
Lintel depth Slide channel,pull action
On request Sound-insulatedSlimline
1) Optional spindle extension
Push-side fixing
36
64
62.5
508.5
64
15
280
315 50
38
5.5
36
Pull-side fixing (not approved for fire and smoke rated doors)
64
36
57.5503.5
64
20
250
350
30
17 12 4
7
586
600
6
DORMA ED 200 for double doors
ED 200
5 6 8 9 4 10
3
2
1
ED 200
2 x
0.8
4 x
0.8
4 x
0.1
4
4 x
0.1
4
2 x
0.8
2 x
0.8
3 x 1.5
L1 NPE
2 x 0.8Interconnecting cableMaster/slave control
7
Active leafInactive leaf
1112
10 A
ConnectionsThe two swing door operatorsfunction on the master-slaveprinciple: The controlsystem for the active leafoperator controls all theparameters of the door suchas the opening, closing and hold-open times, andalso the functions triggeredby the safety sensors.The power supply to theinactive leaf operator is provided by the standardcontrol unit. The mechanicalsettings are individuallyadjusted for each operator.
Inactive leaf
Active leaf
X
36
133
133
7
Connections
01 Power supply line: 230 V,50/60 Hz
02 Emergency stop pushbuttonto DIN VDE, mounted close
to the door
03 Two-pole-and-earth socket,by others; if no socket to be
used, lockable main switch
to be fitted by others
04 External program switch, 4-position; cable length
max. 100 m
05 Pushbutton/switch, internal06 Pushbutton/switch, external
07 Electric strike plate08 Activator, internal09 Activator, external10 Key switch11 DORMA ED 200
with comfort control unit,
active leaf
12 DORMA ED 200 with standard control,
inactive leaf
Lintel depth X Standardarm,push action
–40 to 120 mm 0180 to 240 mm 02
240 to 360 mm 031) Optional spindle extension
Lintel depth Slide channel,pull action
On request Sound-insulatedSlimline
1) Optional spindle extension
1)
1)
Active leaf
Standard arm: B = min. 1284 mm
Slide channel, push action (not approved for fire and smoke check doors) –sound-insulated: B = min. 1561 mm; slimline: B = 1536 mm
Inactive leaf
Slide channel, pull action –
sound-insulated: B = min. 1690 mm; slimline: B = 1720 mm
Fixing on the pull and push side (not approved for fire and smoke check doors)
36
6457.5
503.5
64
20
250
350
47
17 12 64
586
600
8
DORMA ED 200 for “contraflow” traffic
Connections
01 Power supply line: 230 V, 50/60 Hz
02 Emergency stop pushbuttonto DIN VDE, mounted close
to the door
03 Two-pole-and-earth socket,by others; if no socket to be
used, lockable main switch
to be fitted by others
04 External program switch, 4-position; cable length
max. 100 m
05 Pushbutton/switch, internal
06 Pushbutton/switch, external
07 Electric strike plate
08 Activator, internal
09 Activator, external
10 Key switch
11 DORMA ED 200 withcomfort unit or standard
control unit
ED 200 ED 200
2 x
0.8
3 x 1.5
L1 NPE
2 x
0.8
2 x
0.8
2 x
0.8
2 x
0.8
2 x
0.8
2 x
0.8
2 x
0.8
Both 2 x 0.8
711
4 6 9 10
3
2
1
10 8 5 4
11
10 A
ConnectionsThe decisive advantage ofthe double door “contraflowtraffic” configuration lies inthe fact that each door leafcontrols just one direction,so separating the ingressand egress flows as usersenter or leave the buildingor area. There is also theadvantage that passagethrough the doors takesplace immediately becausethey always open in the walking direction.This solution is thereforeparticularly suitable fordoors in which there is aconstant or occasionallyheavy flow of users. Forexample, the entrances todepartment stores, leisurefacilities and administrationbuildings, and also the kitchen entrances of largerestaurants and hotels.The two swing door operatorsoperate individually: The control system of eachoperator governs all theparameters such as the opening, closing and hold-open times, and also thefunctions triggered by thesafety sensors.
64
36
62.5
508.5
64
15
B
34
12644
1
315
280
50
9
Push side Standardarm,
Lintel depth push action0 to 120 mm 01
80 to 240 mm 02240 to 360 mm 03
Pull side Slide channel,Lintel depth pull actionOn request Sound-
insulatedSlimline
1) Optional spindle extension
1) 1)
Push-side fixing
6462.5
508.564
15
280
315 50
38
5.5
10
6
665
36
10
DORMA ED 200 for single fire andsmoke check doors
DORMA RMZ 2 smoke detectors
DORMA RM smoke detectors
In the case of single fire andsmoke rated doors, theDORMA ED 200 automaticswing door operator isalways fixed on the pushside. In the event of a fire,it can be actuated to closeboth by the DORMA RMZ 2and the DORMA RM smokedetector. The power supplyof the DORMA RM smokedetectors is provided by theDORMA ED 200 swing dooroperator with comfort controlunit or the DORMA RMZ 2smoke detector.The DORMA ED 200 canalso be connected to smokedetector systems of otherapproved manufacturers.
As a rule, at least one smokedetector must be fixed tothe lintel or frame above thetop edge of the clear openingon one side of the door. Inaddition, ceiling-mountedsmoke detectors should alsobe appropriately positionedin accordance with localregulations and guidelinesfor hold-open systems.
Depending on requirements,individual or several electricstrike plates or electro-mechanical locks may alsobe connected. These mustoperate in accordance withthe fail-secure principle. Inaddition, it must be ensuredthat they are installed in the correct (approved) position.A manual release push-button/switch must also befitted.For all components, includingthe electric strike plates,approvals must be obtainedin accordance with local regulations.
for LH and RH doors (Example shows RH door)
DORMA RMZ 2 smoke detectorThe DORMA RMZ 2 smokedetector consists of an optical smoke sensor forframe mounting, and anintegrated stabilised powersupply unit. The equipmentincludes connections forother DORMA RM smokedetectors, a floating change-over contact, a connectionfor a manual release deviceand an operating status indicator. The RMZ 2 mustnot be mounted on the coverof the DORMA ED 200.
DORMA RM smoke detectorThe DORMA RM is a universal optical smokedetector designed for both frame and ceilinginstallation. It is connectedto a DORMA RMZ 2 smoke detector or a DORMAED 200 swing door operatorwith comfort control unit. The equipment includesconnections for otherDORMA RM smoke detectors,a connection for a manualrelease device and an operating status indicator.
325 52
53
∅ 4.5
32
29553
52195
170
32
l 4.5
X
11
Connections
5 6 8 9 4 10
3
2
1
ED 200
2 x
0.8
4 x
0.8
4 x
0.1
4
4 x
0.1
4
2 x
0.8
2 x
0.8
3 x 1.5
L1 NPE
2 x 0.84 x 0.84 x 0.8
4 x 0.8
2 x 0.8
Türzu
14
1112
7
15
13
10 A
01 Power supply line: 230 V, 50/60 Hz
02 Emergency stop pushbuttonto DIN VDE, mounted close
to the door
03 Two-pole-and-earth socket,by others; if no socket to be
used, lockable main switch
to be fitted by others
04 External program switch,optional with standard
control (3-position),
necessary with comfort
control unit (4-position);
cable length max. 100 m
05 Pushbutton/switch, internal06 Pushbutton/switch, external07 Electric keep, open-circuit
(fail-secure)
08 Activator, internal09 Activator, external
10 Key switch11 DORMA ED 20012 DORMA RMZ 2 smoke
detector or DORMA RM
smoke detector (3 x 1.5 for
230 V, 50/60 Hz only for
DORMA RMZ 2)
13 DORMA RM smoke detector(Frame or ceiling mounted)
14 Connection to smoke detector on the pull side
15 Manual release push-button/switch
ConnectionsApproval certification
The DORMA ED 200 auto-matic swing door operator is approved in Germany bythe MPA NRW Dortmund(State Material TestingAuthority) in accordancewith DIN 18263, Part 4,and is subject to third-partyquality assurance verification.In conjunction with DORMAframe and ceiling mountedsmoke detectors, it is approved by the DIBt ofBerlin (German Institute forBuilding Technology) for useon single and double fireand smoke rated doors provided that this is allowedby the approval certificatefor the door concerned.
The DORMA ED 200 hasbeen tested as a hold-opendevice for single and doubledoors in accordance withGerman guidelines governinghold-open systems.
The DORMA RMZ 2 smokedetector and also theDORMA RM smoke detectorare approved by the DIBt,Berlin (German Institute forBuilding Technology), andare subject to third-partyquality assurance verification.
Lintel depth X Standardarm
–40 to 120 mm 0180 to 240 mm 02
240 to 360 mm 031) Optional spindle extension
1)
DORMA ED 200 with DORMA RM smoke detector mounted on the cover (the DORMA RMZ 2 smoke detector must not be mounted on the cover)
Push-side fixing
36
64
62.5
508.5
64
15
280
315 50
38
5.5
36
12
DORMA ED 200 for double fire andsmoke-check doors
Door co-ordinatorIn the case of double fireand smoke rated doors, thetwo DORMA ED 200 auto-matic swing door operatorsare always fixed to the pushside, while on the pull sidethere is a DORMA G 93GSR slide channel door co-ordinator with two pivotblocks. In addition, the dooris also equipped with amanual unlocking device forthe inactive leaf. The two swing door operatorsoperate according to themaster-slave principle:The control system for theactive leaf operator controlsall the parameters of thedoor such as the opening,closing and hold-open times,and also the functions triggered by the safety sensors.
The power supply to theinactive leaf operator isprovided by the standardcontrol unit. The mechanicalsettings are individuallyadjusted for each operator.In the event of a fire, it canbe actuated to close both bythe DORMA RMZ 2 and theDORMA RM smoke detector.The DORMA ED 200 canalso be connected to smokedetector systems of otherapproved manufacturers.
Further informationSee page 10 for furtherinformation relating to thepower supply system, thepositioning of the smokedetectors and also providingthe door with electric strikeplate or locks.
The DORMA G 93 GSR slidechannel door co-ordinatorwith two pivot blocks ensuresthat, in the event of an alarm,the two door leaves close in the correct sequence(inactive leaf before activeleaf) so producing a tightbarrier seal.
The DORMA G 93 GSR withpivot blocks is approved bythe MPA NRW, Dortmund(State Material TestingAuthority) for use on doublefire and smoke rated doors.An approval certificate forthe fire and smoke rateddoor is also necessary.
Approval certification
The DORMA ED 200 auto-matic swing door operator isapproved in Germany by theMPA NRW Dortmund (StateMaterial Testing Authority) inaccordance with DIN 18263,Part 4, and is subject to third-party quality assuranceverification. In conjunctionwith DORMA frame and ceilingmounted smoke detectors, it isapproved by the DIBt of Berlin(German Institute for BuildingTechnology) for use on singleand double fire and smokerated doors provided that thisis allowed by the approval cer-tificate for the door concerned.The DORMA ED 200 hasbeen tested as a hold-opendevice for single and doubledoors in accordance withGerman guidelines governinghold-open systems.
B
142
122 106
66
53
13
26
470
4
Offset B Door width88 mm 1270 to 1500 mm34 mm greater than 1500 mm
Inactive leaf
36
B
X
01 Power supply line: 230 V, 50/60 Hz
02 Emergency stop pushbuttonto DIN VDE, mounted close
to the door
03 Two-pole-and-earth socket,by others; if no socket to be
used, lockable main switch
to be fitted by others
04 External program switch, 4-position; cable length
max. 100 m
05 Pushbutton/switch, internal06 Pushbutton/switch, external07 Electric strike plate,
open-circuit (fail-secure)
08 Manual unlocking09 Activator, internal10 Activator, external11 Key switch12 DORMA ED 200
with comfort control,
active leaf
13 DORMA ED 200 with standard control,
inactive leaf
14 DORMA RMZ 2 or DORMA RM smoke detector
15 DORMA RM smoke detector(frame or ceiling mounted)
16 Connection to smoke detector on the pull side
17 Manual release push-button/switch
13
Connections
ED 200
14ED 200
2 x
0.8
4 x
0.8
4 x
0.1
4
4 x
0.1
4
2 x
0.8
2 x
0.8
3 x 1.5
2 x 0.8
7Türzu
Active leafInactive leaf
1213 4 x 0.8
5 6 9 10 4 11
1 L1 NPE
3
2
1516
8
17
10 A
Connections
Lintel depth X Standardarm
–40 to 120 mm 0180 to 240 mm 02
240 to 250 mm 031) Optional spindle extension
1)
Active leaf
14
DORMA ED 200for buildings designed for the agedand disabled
Functional sequence of an automated WC door
Thanks to its wide range of adjustment and connection possibilities, the DORMA ED 200 swingdoor operator with itssmooth, highly reliable operation is ideal for theautomation of special-
purpose doors. In particular,it can be used to optimisefacilities in buildings designed for the aged andthe disabled. A typicalexample is the access to arest room equipped in accord-ance with DIN 18224/25.
34
65
78
9
10
11
In order to enter the restroom, the user has to operatethe externally positionedpalm pushbutton (3). Thisreleases the electric strikeplate (10) which operates inaccordance with the fail-safemode. The DORMA ED 200swing door operator (11)then receives an actuatingsignal and opens the doorfollowing a short delay. Onexpiry of the preset hold-open time, the DORMA ED 200 (11) then closes thedoor which is then locked.
Once inside the rest room, theuser switches off the externalpalm pushbutton (3) usingpalm switch/pushbutton (7),at the same time switchingon the occupied light locatedon the outside (5). The signal lamp (9) inside therest room also lights up forconfirmation purposes.
In order to leave the rest room,palm switch/pushbutton (7)is first operated. This releases the palm switch (3)and switches off the occupied lamp (5). The signal lamp (9) inside therest room also goes out. Atthe same time, the electric strike plate (10) is activatedand a delayed opening signal is transmitted to the ED 200 (11).
In the event of an emergency,the user can operate theemergency switch (8) fromthe inside in order to de-activate the electric keep(10) so that the door can be opened from the outside.At the same time, theaudible signal transmitter(6) is switched on; furtheroperation of the emergencyswitch (8) switches it offagain.
By operating the emergencypushbutton (4) locatedbehind the emergency breakglass on the outside, theelectric keep (10) can beswitched off and the dooropened manually. In theevent of a power failure, theelectric keep (10) is againswitched off to allow access.
Sensors ensure that thesweep range of the door iseffectively protected.
15
10 A
PENL1
2 x 0.8
3 x
1.5 4
x 0
.8
2 x
0.8
2 x
0.8
2 x
0.8
2 x
0.8
4 x
0.8
6 x 0.8
3 x
1.5
200 x 125 x 77
AufVerriegelt
12
2
11
13
1
103 4
6
5
9
7 8
ConnectionsConnections
1 Power supply line: 230 V, 50/60 Hz
2 Two-pole-and-earth socket,by others; if no socket to be
used, lockable main switch
to be fitted by others
3 Palm switch, external,stainless steel design, with
disabled symbol
4 Emergency pushbutton,external, with emergency
break glass
5 Occupied signalling lamp,external
6 Audible alarm7 Palm switch/pushbutton,
internal, stainless steel
finish, with lettering
“Open/Locked”
8 Emergency switch, internal9 Signal lamp, internal
10 Electric strike plate
Specification text – DORMA ED 200 for buildings designed for the aged and disabled
Electro-hydraulic swing door operator for special applications inbuildings designed for the aged and disabled
Door parameters:Door leaf width max. 1400 mmDoor leaf weight max. 250 kgOpening angle max. 115°
Drive unit:( ) Size EN 4 – 6, adjustable( ) Size EN 7Opening and closing speed, backcheck and delayed closingaction independently adjustable; automatic closing action.Manufactured in accordance with German guidelines for power-operated windows, doors and gates, ZH 1/494 latest edition,and VDE (German Association of Engineers) standards. Type approved by the German technical inspectorate (TÜV);tested and approved in accordance with low-voltage directives;manufactured on the basis of a quality management systemregistered to ISO 9000.
Power supply:230 V, 50/60 Hz
( ) Standard control:Microprocessor control, 24 vAC/DC, 12 vAC, 800 mA (AC), 400 mA (DC)Function programs: Off; Permanent open (rated for continuousduty); Automatic; Hold-open time adjustable between 0 and 30 s.Connection for pull side/push side safety sensors.Connection for electric strike plate.
( ) Comfort control unit:Microprocessor control as above, but 1500 mA (AC), 800 mA(DC), and also additional Exit only and Night-bank facility.Push-side safety sensor can be switched off in door-closed position.Stabilised power supply unit 24 V DC for smoke detectors.
( ) Equipment for both control options:External visual and audible alarm facility; switch-off of theexternal activators from the inside with visual indication of thelock status, release from the outside in the event of an emer-gency, alarm initiation and unlocking signal from the inside.Installation in accordance with DIN 18224/25.
Cover design:( ) Standard, dimensions (H x D x B) 103 x 166 x 665 mm( ) Extended cover, dimensions: ................ mm
Arm:( ) Standard arm for lintel depth of
( ) –40–120 mm ( ) 80–240 mm ( ) 240–360 mm( ) Spindle extension (13, 21, 30, 48, 73, 95 mm)
( ) Slide channel( ) Pull side ( ) Push side( ) Sound-insulated( ) Spindle extension (21, 30, 48 mm)
Switches, pushbuttons:Program switch:( ) lockable ( ) non-lockable( ) external, concealed ( ) external, surface-mountedEmergency off pushbutton:( ) external, concealed ( ) external, surface-mounted( ) double box( ) main switch lockable
Activators:( ) Switch/pushbutton, stainless steel, internal( ) Switch/pushbutton, stainless steel, external( ) Visual and audible alarm, external( ) Signal lamp, internal( ) Infra-red safety sensor (35, 70, 90, 120 mm)
Electric keep:( ) Type 22/32 WD, eE 24 DC
Power supply unit:( ) Auxiliary power supply, SM 201, 12/24 V, 1.5 A
Surface finish:( ) silver anodised (Eloxal E6/C0)( ) dark-brown anodised (Eloxal E6/C34)( ) RAL .......................
Make:DORMA ED 200
11 DORMA ED 20012 Auxiliary control unit,
external, in control box or
housed in extended cover
13 Junction box by others
According to German standard
DIN 18224/25, the door
must open outwards and have
a width of min. 900 mm.
insideoutside
RM
AS or BL RZ 12 + SVP-S 22
TL
CODIC
TV 100ED 200
SVP 2000
SVP 2000
ED 200 + SVP-S 22
ST
Centralcontrolstation
TV 500
ED 200 +Special controlunit
TV 100
16
DORMA ED 200 Example combinations
Emergency exit security system
Under normal conditions, thedoor is locked (TV 100, TV 500electro-mechanical lock).Operation of the emergency push-button in the DORMA TL doorterminal causes the lock to beswitched off and the lock boltand latch of the DORMA SVP2000 (emergency escape motorlock with automatic lockingaction) to be retracted; at thesame time a system alarm is triggered. The DORMA ED 200simultaneously receives its opening signal. Authorised per-sonnel can initiate this sequenceof operations by means of thekey switch/momentary contactfacility of the DORMA TL or a
DORMA access control systemsuch as the CODIC facility. If theDORMA RM smoke detector responds, the DORMA TV lock isunlocked, the DORMA SVP 2000is locked and the DORMA ED 200is de-energised. In the event ofactivation from a central controlstation, the TV electro-mechanicallock is unlocked, the SVP 2000disengages and the ED 200 opensthe door. An approval certificatefrom the NRW MPA (StateMaterial Testing Authority) andalso a VdS approval certificate(German Association of PropertyInsurers) have both been issuedfor this system for use in emer-gency exit and escape routes.
Insurance-compliant security locking system
In its closed state, the dooris locked by the DORMASVP 2000 emergency escapemotor lock with automaticlocking action (insurance-compliant security lockingsystem). The door can beopened at any time from theinside, with the unlockingaction of the DORMA SVP 2000 and the delayed operation of the DORMA ED 200 initiated eithermanually or by means ofpositive activators.Activation from a centralcontrol station is also
possible. Following closureof the door, insurance-compliant locking is re-instated fully automaticallyas the bolt of the DORMASVP 2000 is automaticallythrown each time the door is closed. The DORMA SVP 2000 is additionallycontrolled by the DORMASVP-S22 motor lock controlsystem which is installed in the extended cover of theED 200.
Doors designed to open when de-energised (fail-safe)
The door (single or double)is closed and locked by theDORMA TV 100 or TV 500electro-mechanical lock. TheDORMA ED 200 is equippedwith a special controlsystem and designed so thatit opens under spring loadand closes under motor power.There are two possibilitiesmodes of door operation:1. Unlocking and openingby one signal; closing andlocking by a repeat signal.2. Unlocking and opening by signal; automatic closingand locking on expiry ofadjustable preset hold-open
time. With this system, thedoor automatically opens inthe event of a power failure.The door cannot be manuallyoperated.
Only type-approved systemsmay be employed in emer-gency exit and escape routes(e.g. DORMA RZ 12, TL-Gwith TL-S control PCB, TV 100, TV 500).
The DORMA IRS 35 infra-redsensor is mounted on thepush side and performs threetasks: In the area closest to the door, it acts as anactivator to open the door.When the door is opened, it prevents it from closingagain – irrespective of thepreset hold-open time –while there are persons orobstructions located in thepassage zone. If a door isstopped by a pull-side sensor,
it ensures that the door isonly released for operationagain once the passage isfree. Where it is necessaryto prevent passers-by fromtriggering an opening pulse(e.g. in doors located in corridor walls), the sensorscan be switched off whenthe door is closed byDORMA ED 200 swing operators featuring theenhanced control system.
17
DORMA ED 200 DORMA IRS infra-redsafety sensors
– Pre-assembled completeready for installation andconnection, with infra-redpermeable plastic lens
– Integrated activating andcontrol electronics
– Sensitivity potentiometer-adjustable
– Available in four lengthsto suit all door widths
– Monitored zone adjustablein the vertical direction inthree stages, and in thehorizontal direction bysliding the sensors withintheir housing; range adjustable up to approx.1000 mm in front of thedoor for an installationheight of max. 2100 mm
– Hinge/opposite hinge side– Suitable for installation on
the push and pull side ofthe door
– Power supply via DORMA ED 200
Mounted on the pull side,the DORMA IRS 70, 90 and 120 infra-red sensorsmonitor the opening sweepof the door. In the event that someone coming fromthe push side initiates an opening pulse while aperson or obstruction islocated in the sweep range,they disable the openingaction.
Features and benefits
DORMA IRS 70, 90, 120
IRS safety sensors
DORMA IRS infra-red safetysensors minimise the risk of people, animals or otherobstructions being hit byautomatically opening andclosing swing doors. Thesensors operate with anactive infra-red light andthus detect any changewhich occurs within theirscanning range.
Type DORMA Length SensorsIRS 35 350 mm 1 sensorIRS 70 700 mm 1 sensorIRS 90 900 mm 2 sensorsIRS 120 1200 mm 2 sensors
Technical data
DORMA IRS 35
18
DORMA ED 200 Activators
– For external installation– Concealed or surface-
mounted– Lockable or with rotary
knob– Suitable for concealed box– Frames in various colours
Program switches
– Eagle system– Directionally sensitive– Non-directionally sensitive
(standard model)– Black finish– Comprehensive range of
accessories– Ceiling installation sets– Weather-resistant cover
Radar motion detectors
– Concealed/surface-mounted installation
– Stainless steel finishes– Water-resistant models– Key switches and push-
buttons– Foot switch for wall or
floor installation– Elbow pads and palm
switches for wall installation
Switches, pushbuttons
Various transmitters andreceivers for VHF and UHFoperation– Single-channel– Multi-channel
Radio remote controls
Electronic access controlsystem, activation by inputting a secret code viathe keypad and/or insertionof an electronically codedCODIC key
CODIC
Proximity access controlsystem, activation on thebasis of a show-and-gosystem with a key fob orclip-on identification deviceshown to a reader/sensorunit.
SENSIC
– Large operating surface– Surface-mounted version– No concealed box
necessary
Push switches
For standard arm Height H mm ....... D mm .....Y mm13 6 3021 14 3830 23 4748 41 6573 66 9095 88 112
For slide channel1321 22 5530 31 6448 49 82
DORMA ED 200 Installation Installed Lintel depthPull side Push side in extended mm
cover
Size EN 4 – 6 (standard control)– For single door 3 3 3– For double door 3 3 3
Size EN 7– For single door 3 3 3– For double door 3 3 3
Size EN 4 – 6 (enhanced control)– For single door 3 3 3– For double door 3 3 3
Size EN 7– For single door 3 3 3– For double door 3 3 3
Standard arm01 3 –40 to 12002 3 80 to 24003 3 240 to 360
Slide channel
– Sound-insulated 3 3– Slimline design 3 3
On application– Standard arm 3 3– Standard arm for contraflow double doors 3 3
Length mm Depth mm Height mmStandard arm and slide channel 659 8 100Extended cover per specification 8 100Double door per specification 8 100
19
DORMA ED 200 Range of equipment
Swing door operator and arm assemblies
Spindle extensions
Mounting backplate
D Y
ED 200
ED 200
D Y
20
Swing Door Operator DORMA ED 200
WN 051 578, 4/99, GB, 6. DD. 4/99
Electro-hydraulic swing door operator for:( ) Standard door
( ) Single ( ) Double( ) Fire and smoke rated door
( ) Single ( ) Double
Door parameters:Door leaf width max. 1400 mmDoor leaf weight max. 250 kgOpening angle max. 115°
Drive unit(s):( ) Size EN 4 – 6, closing force adjustable, ...units( ) Size EN 7, ...unitsOpening and closing speed, backcheck and delayed closingaction independently adjustable; automatic closing action.
Manufactured in accordance with German guidelines for power-operated windows, doors and gates, ZH 1/494 latest edition,German UVV (accident prevention) regulations and VDE(German Association of Engineers) standards. Type approved bythe German technical inspectorate (TÜV); tested and approvedin accordance with low-voltage directives; manufactured on thebasis of a quality management system registered to ISO 9000.
Power supply:230 V, 50/60 Hz
( ) Standard control:Microprocessor control,24 vAC/DC, 12 vAC, 800 mA (AC), 400 mA (DC)Function programs: Off; Permanent open (rated for continuousduty); Automatic; Hold-open time adjustable between 0 and 30 s.Connection for pull side/push side safety sensors.Connection for electric keep; Push-and-Go optional
( ) Comfort control unit:Microprocessor control,24 vAC/DC, 12 vAC, 1500 mA (AC), 800 mA (DC)Function programs: Off; Permanent open (rated for continuousduty); Automatic; Exit only (external program switch); Night-bank facility; Hold-open time adjustable between 0 and 30 s.Connection for safety sensors on pull and push side, push-side safetysensor switched off in door-closed position, Push-and-Go optional.Plus stabilised power supply unit 24 V DC for DORMA RMsmoke detector; connection for approved electric strike plate;connection for DORMA SVP 2000 emergency exit motor lockwith automatic locking action.
Cover design:( ) Standard, dimensions (H x D x B) 103 x 166 x 665 mm( ) Extended cover, size: ................ mm( ) Full-width cover for double door,
Size: ................ mm, Hinge centres: ................ mm
Gestänge:( ) Arm:
( ) Lintel depth –40 – 120 mm, ...units( ) Lintel depth 80 – 240 mm, ...units( ) Lintel depth 240 – 360 mm, ...units
( ) Spindle extension for standard arm( ) 13 mm, ...units ( ) 21 mm, ...units( ) 30 mm, ...units ( ) 48 mm, ...units( ) 73 mm, ...units ( ) 95 mm, ...units
( ) Slide channel, sound-insulated( ) Slide channel, slimline design( ) Spindle extension for slide channel
( ) 13 mm, ...units ( ) 21 mm, ...units( ) 30 mm, ...units ( ) 48 mm, ...units
( ) Mounting backplate( ) DORMA G 93 GSR slide-channel door co-ordinator
with 2 pivot blocks
Switches, pushbuttons:Integrated program switch:( ) 3-position (external) ( ) 4-position (external)Program switch, external:( ) lockable ( ) non-lockable( ) concealed ( ) surface-mountedEmergency stop pushbutton, external:( ) concealed ( ) surface-mounted( ) concealed with double box
( ) Main switch, external, lockable
Activators:( ) Radar movement detector, type ..., ... units( ) Pushbutton, type ..., ... units( ) Radio remote control E 43-1, including hand-held
transmitter, ... units( ) SENSIC( ) CODIC ATL( ) Other: ..., ... units
( ) DORMA IRS infra-red safety sensor on the pull side( ) 700 mm, ... units ( ) 900 mm, ... units( ) 1200 mm, ... units
( ) DORMA IRS infra-red safety sensor on the push side, 35 mm, ... units
Electric strike plate:( ) effeff Type 141, 24 vAC, vertical only( ) effeff Type 142, 24 vAC, vertical only( ) effeff 142.12/13, vertical and horizontal( ) effeff 131, vertical and horizontal( ) Type 22/32 WD, eE 24 DC
Smoke detectors:( ) DORMA RMZ smoke detector, ... units
(not to be mounted on the cover of the ED 200!)( ) DORMA RM smoke detector, ... units
Accessories for operators installed on fire and smoke check doors:Pushbutton for manual release, ... units( ) surface-mounted ( ) concealed
Surface finish:( ) silver anodised (Eloxal EV6/C0)( ) dark-brown anodised (Eloxal EV6/C34)( ) RAL .......................
Make:DORMA ED 200
Subject to change without notice DORMA GmbH + Co. KGPostfach 4009D-58247 EnnepetalTel. +49(0)2333/793-0Fax +49(0)2333/79 34 95www.dorma.de
Specification text