Staus Report EMBL Hamburg
Gleb Bourenkov
Kappa Workgroup MeetingSeptember 20-21, 2009EMBL Grenoble
Gleb Bourenkov Kappa Workgroup Meeting20/09/2010
EMBL@PetraIII
Gleb Bourenkov Kappa Workgroup Meeting20/09/2010
MX1Michele Cianci
MX2 Gleb
Bourenkov
BioSAXS Manfred Roessle
Energy [keV] 5(4)-17 7-35 4-20
MonochromatorsSi(111) Si(311)
Si(111) Si(311)
Si(111)
Smallest Focus H x V [µm2]
30 x 20 4 x 1 200 x 60
Divergence H x V [mrad2]
0.2x0.15 0.5 x 0.3 0.04 x 0.01
Demagnification H / V
1:12/1:15 1:40/1:30 1:1.4 / 1: 1.2
Intensity [ph/sec], Si111
1012- 3*1013 1013 1013
Both MX1 and MX2 will be equipped with MiniKappa device
Gleb Bourenkov Kappa Workgroup Meeting28/09/2009
First light at MX2 – last Friday
Gleb Bourenkov Kappa Workgroup Meeting20/09/2010
PETRAIII MX – BW7A DORIS test bench
MD2/MiniKappa recived in 07-10/2009 commissioned at BW7A/DORIS beamline
Gleb Bourenkov Kappa Workgroup Meeting20/09/2010
STAC with TINE interface
MD3 – Kappa diffractometer for micro-crystallography, SOC in 100 nm range
Gleb Bourenkov Kappa Workgroup Meeting20/09/2010
Florent Cipriani and Frank Felicaz
Gleb Bourenkov Kappa Workgroup Meeting20/09/2010
Prototype at DORIS beamline BW7b.
In operation for in house users.
BCU
Focusing KB mirrors
MARVINMD2/MD3 diffractometer
MARVIN sample changer
MX data collection software
Gleb Bourenkov EMBL@PETRAIII SAB Meeting20/09/2010
MxCuBEGUI
MxCuBEGUI
Data Collection Server
Data Collection Server
Detector ServerDetector Server MD2 ServerMD2 ServerDetecto
rstage
Detector
stage
Energy
Energy AttrAttr Ring
currentRing
current
TINE CSScripting
Python – PyTINEShell – TINE
ScriptingPython – PyTINE
Shell – TINE
……
Gleb Bourenkov Kappa Workgroup Meeting20/09/2010
Gleb Bourenkov Kappa Workgroup Meeting20/09/2010
Gleb Bourenkov EMBL@PETRAIII SAB Meeting20/09/2010
MD2 linear positioning repeatability
• Gauge resolution 0.1 µm
• Spindle alignment table 0.1(3) µm r.m.s. • Centering table 0.2 µm r.m.s.• Aperture etc. 0.2 µm r.m.s.
-0.4 -0.2 0 0.2 0.4
5
10
15
20
25
ΩY
Gleb Bourenkov EMBL@PETRAIII SAB Meeting20/09/2010
Sphere of Confusion: measurements
0.033 µm/pixel
0.033 µm/pixel
0.33 µm/pixel (LR)
250 500 750 1000 1250 1500 1750
540
550
560
570
position vs anlgle
1st harmonic - centering
5 10 15 20
2
4
6
8
10
5 10 15 20
20
40
60
80
100
120
5 10 15 20
25
50
75
100
125
150
175
5 10 15 20
20
40
60
80
100
120
5 10 15 20
2
4
6
8
10
5 10 15 20
2
4
6
8
10
12
14
5 10 15 20
2
4
6
8
10
5 10 15 20
2
4
6
8
10
Fourier spectrum
2 3 22 23
continuous rotation, fast, vertical
steps, OAV
continuous, fast, horizontal
continuous, slow, horizontal
steps, OAV, slow, miniKappa, closed
steps, OAV, offset
steps, OAV, slow
steps, OAV, slow, miniKappa, open
Gleb Bourenkov EMBL@PETRAIII SAB Meeting20/09/2010
MD2 SOC without miniKappa
50 100 150 200 250 300 350
-0.4
-0.2
0.2
0.4
50 100 150 200 250 300 350
-0.4
-0.3
-0.2
-0.1
0.1
0.2
0.3
50 100 150 200 250 300 350
-0.15
-0.1
-0.05
0.05
0.1
0.15
2nd+3rd harmonicsgravity effects oncentering table
20th+23rd harmonicsOmega motor poles
0.75
µm
0.3
µm
0.9
µm
r.m.s. = 0.25 µm
peak-to-peakdiameter = 0.9 µm
Gleb Bourenkov EMBL@PETRAIII SAB Meeting20/09/2010
SOC with miniKappa
SOC with miniKappa: 0.7 µm r.m.s. 2.4 µm peak-to-peak diameter
only the 2nd harmonic (centering table) amplitude increase,no phase change, no new features
50 100 150 200 250 300 350
-1
-0.5
0.5
1miniκ=0miniκ=60
constant magnet
Gleb Bourenkov Bilateral GR-HH Instrumentation Meeting24/11/2009
MiniKappa: repeatabilitymove to reference,move to position
phi
move around, come back
off by ~3º
re-initialize
back within <0.05º
kappa
CONFUSION!
When motors are driven from the MD2 Kappa motor tuning box using default “motor” coordinate system, the backlash and relaxation corrections are not applied.(Positioning is not repeatable)
When driven from the device server or in any other way using the “device” coordinate system the corrections are applied, but the position is not updated during the backlash correction – so it looks like it is not applied.(Positioning is repeatable)
Device is OK, control via STAC is OK
CONFUSION!
When motors are driven from the MD2 Kappa motor tuning box using default “motor” coordinate system, the backlash and relaxation corrections are not applied.(Positioning is not repeatable)
When driven from the device server or in any other way using the “device” coordinate system the corrections are applied, but the position is not updated during the backlash correction – so it looks like it is not applied.(Positioning is repeatable)
Device is OK, control via STAC is OK