Title page
Alcatel-LucentRemote Radio Head 2X60W - 850, 1900 MHz
Maintenance Guide
3MN-01477-0004-REZZAIssue 0.02 | January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 2/68
Legal notice
Legal notice
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright © 2014Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside
Alcatel-Lucent without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 3/68
Contents
About this document
Purpose ............................................................................................................................................................................................. xixi
Reason for reissue ........................................................................................................................................................................ xixi
Intended audience ....................................................................................................................................................................... xiixii
Supported systems ...................................................................................................................................................................... xiixii
How to use this document ........................................................................................................................................................ xiixii
Safety information ......................................................................................................................................................................
xiixii
Prerequisites .................................................................................................................................................................................. xiixii
Conventions used ........................................................................................................................................................................ xiixii
Related information ................................................................................................................................................................... xiiixiii
Document support ....................................................................................................................................................................... xvxv
Technical support ......................................................................................................................................................................... xvxv
How to order .................................................................................................................................................................................. xvxv
How to comment .......................................................................................................................................................................... xvxv
1 Safety statements
Overview ...................................................................................................................................................................................... 1-11-1
Structure of safety statements ............................................................................................................................................... 1-21-2
2 Preventive maintenance
Overview ...................................................................................................................................................................................... 2-12-1
Preventive maintenance activity .......................................................................................................................................... 2-22-2
3 Corrective maintenance
Overview ...................................................................................................................................................................................... 3-13-1
Corrective maintenance ......................................................................................................................................................... 3-23-2
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
iii
PRELI M
I NARY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 4/68
4 Introduction
Overview ...................................................................................................................................................................................... 4-14-1
RRH 2X60W solution ............................................................................................................................................................. 4-24-2
5 Hardware description
Overview ...................................................................................................................................................................................... 5-15-1
RRH 2X60-1900/1900A hardware description .............................................................................................................. 5-25-2
RRH 2X60-850 and hardware description ...................................................................................................................... 5-75-7
Node B hardware requirements for RRH support ...................................................................................................... 5-115-11
6 Power up and power down procedures
Overview ...................................................................................................................................................................................... 6-16-1
Powering up an RRH 2X60W .............................................................................................................................................. 6-26-2
Powering down an RRH 2X60W ........................................................................................................................................ 6-46-4
7 Preventive maintenance procedures
Overview ...................................................................................................................................................................................... 7-17-1
Inspecting connectors .............................................................................................................................................................. 7-27-2
Inspecting pole brackets and pole bands .......................................................................................................................... 7-47-4
8 Corrective maintenance procedure
Overview ...................................................................................................................................................................................... 8-18-1
Replacing an RRH 2X60W ................................................................................................................................................... 8-28-2
A Product conformance statements
Overview ..................................................................................................................................................................................... A-1A-1
European regulatory requirement compliance .............................................................................................................. A-2A-2
Americas Region regulatory requirement compliance ............................................................................................... A-4A-4
Federal Communications Commission ............................................................................................................................ A-5A-5
Compliances for other regions/countries ........................................................................................................................ A-7A-7
Operating conditions .............................................................................................................................................................. A-8A-8
Contents
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
iv Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 5/68
Cable specifications ................................................................................................................................................................ A-9A-9
Product labeling ..................................................................................................................................................................... A-10A-10
Index
Contents
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
v
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 6/68
Contents
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
vi Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 7/68
List of tables
1 Issue 0.02, January 2014, Reason for reissue .................................................................................................... xixi
2 Issue 0.01, April 2013, Reason for reissue .......................................................................................................... xixi
3-1 RRH 2X60W orderable items ............................................................................................................................... 3-23-2
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
vii
PRELI M
I NARY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 8/68
List of tables
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
viii Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 9/68
List of figures
4-1 Connections between RRH 2X60W and a d2U Node B ............................................................................. 4-24-2
5-1 RRH 2X60-1900 two antennas bulkhead top view ....................................................................................... 5-25-2
5-2 RRH 2X60-1900A four antennas bulkhead top view ................................................................................... 5-35-3
5-3 RRH 2X60-1900/1900A bulkhead bottom view ............................................................................................ 5-45-4
5-4 RRH 2X60-850 two antennas bulkhead top view ......................................................................................... 5-75-7
5-5 RRH 2X60-850 bulkhead bottom view ............................................................................................................. 5-85-8
7-1 Pole brackets and pole bands ................................................................................................................................
7-57-5
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
ix
PRELI M
I NARY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 10/68
List of figures
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
x Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 11/68
About this documentAbout this document
Purpose
The purpose of this document is to describe the preventive and corrective procedures
applicable to the following Alcatel-Lucent Remote Radio Head variants:
• 2X60W, 850 MHz
•
2X60W, 1900 MHz• 2X60W, 1900A MHz
Reason for reissue
The reissue history for issue 0.02 is shown in the following table:
Table 1 Issue 0.02, January 2014, Reason for reissue
Location Change
Reason for reissue LR13.3W:FRS 165530 - RRH2x60-1900A (4 antennas) with
9396 digital units
Related information CR 01145957 + CR 01145972 (old references of documents)
The reissue history for issue 0.01 is shown in the following table:
Table 2 Issue 0.01, April 2013, Reason for reissue
Location Change
None First issue as release-independent document (from NN20500-308,
Release: UA08.1), with updated comments.
The decision has been made to split the document NN20500-308into 2 documents:
- one specific to AT&T: the present document (3MN-01477-0004-
REZZA)
- the other one specific to GM customers
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
xi
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 12/68
Intended audience
The audience for this document is Operations and maintenance personnel.
Supported systems
This release-independent document applies to all Alcatel-Lucent W-CDMA system
releases.
How to use this document
No specific recommendation applies regarding the way readers should read this
document.It applies to the AT&T dedicated products and configuration WCDMA with
9396 d2U or d4U OneBTS.
Safety information
For your safety, this document contains safety statements. Safety statements are given at
points where risks of damage to personnel, equipment, and operation may exist. Failure tofollow the directions in a safety statement may result in serious consequences.
Prerequisites
It is recommended that readers become familiar with the following documents:
• Alcatel-Lucent Remote Radio Head 2X60W - 850, 1900 MHz for W-CDMA -
Technical Description, 3MN-01477-0003-DEZZA
Conventions used
Vocabulary conventionsFor a list of the terms, see Alcatel-Lucent W-CDMA System - Terminology,
9YZ-04088-0002-TQZZA.
For convenience, the following terms are used in this publication:
• RRH 2X60-850, RRH 2X60-1900, RRH 2X60-1900A
• RRH 2X60W
• RRH
Typographical conventions
The following typographical conventions are used in this document:
Appearance Description
Italicized text Emphasized information
graphical user interface text Text that is displayed in a graphical user
interface or in a hardware label.
About this document
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
xii Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 13/68
Appearance Description
Document reference, reference number Related document that is referenced in the
document
Related information
For information on subjects related to the content of this document, refer to the
documents listed in the following table:
For information on subjects related to the content of this document, refer to the
documents listed in the following table:
Refer to this document At this location For more information on
RRH2X60-XX Model Offer
Provisioning Guide,
UMT/PFO/APP/032664
http://support.alcatel-lucent.
com.
RRH2x
Alcatel-Lucent W-CDMA
System - Safety Guide,
9YZ-04088-0007-TQZZA
http://support.alcatel-lucent.
com.
Safety guidelines and the
catalog of hazard statements
that appear in the
Alcatel-Lucent UMTS
customer documents.
RRH Product Engineering
Information ,
UMT/IRC/APP/020716
http://support.alcatel-lucent.
com.
RRH configurations
Alcatel-Lucent Remote Radio
Head 2X60 W - 850, 1900
MHz - Technical Description,
3MN-01477-0003-DEZZA
http://support.alcatel-lucent.
com.
RRH technical description
Alcatel-Lucent Remote Radio
Head 2X60 W - 850,
1900MHz - Hardware
Installation,
3MN-01477-0002-RJZZA
http://support.alcatel-lucent.
com.
RRH installation
Alcatel-Lucent 9396 digital
2U Node B - Technical
Description,3MN-00514-0005-DEZZA
http://support.alcatel-lucent.
com.
d2U technical description
Alcatel-Lucent 9396 digital
4U Node B - Technical
Description,
3MN-00512-0005-DEZZA
http://support.alcatel-lucent.
com.
d4U technical description
About this document
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
xiii
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 14/68
Refer to this document At this location For more information on
Alcatel-Lucent 9396 digital
2U Node B - Hardware
Installation,
3MN-00514-0004-RJZZA
http://support.alcatel-lucent.
com.
d2U hardware installation
Alcatel-Lucent 9396 digital
4U Node B - Hardware
Installation,
3MN-00512-0004-RJZZA
http://support.alcatel-lucent.
com.
d4U hardware installation
Alcatel-Lucent 9396 digital
2U Node B - Installation Test,
3MN-00514-0003-RJZZA
http://support.alcatel-lucent.
com.
d2U installation test
Alcatel-Lucent 9396 digital
4U Node B - Installation Test,
3MN-00512-0003-RJZZA
http://support.alcatel-lucent.
com.
d4U installation test
Alcatel-Lucent 9396 digital
2U Node B - Operations,
Administration, and
Maintenance,
3MN-00514-0006-REZZA
http://support.alcatel-lucent.
com.
d2U operation, administration
and maintenance
Alcatel-Lucent 9396 digital
4U Node B - Operations,
Administration, and
Maintenance,
3MN-00512-0006-REZZA
http://support.alcatel-lucent.
com.
d4U operation, administration
and maintenance
Alcatel-Lucent 9353 Wireless
Management System – Fault
Management,
9YZ-04088-0010-ACZZA
http://support.alcatel-lucent.
com.
Fault management
W-CDMA FIMS-UT Main
Maintenance Terminal Online
Help
http://support.alcatel-lucent.
com.
Main maintenance terminal
W-CDMA Remote
Maintenance Tool Online
Help
http://support.alcatel-lucent.
com.
Remote maintenance tool
W-CDMA Local Maintenance
Terminal Online Help
http://support.alcatel-lucent.
com.
Local maintenance terminal
Standard for Installation of
Lightning Protection Systems,
NFPA
http://support.alcatel-lucent.
com.
Installation of lightning
protection systems
About this document
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
xiv Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 15/68
Refer to this document At this location For more information on
Recommended Practices on
Surge Voltages in Low Voltage
AC Power Circuits, IEEE
C62.41 (Latest Edition)
http://support.alcatel-lucent.
com.
Power
Document support
For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
one of the following telephone numbers:
• 1-888-582-3688 (for the United States)
• 1-630-224-2485 (for all other countries)
Technical support
For technical support, contact your local Alcatel-Lucent customer support team. See theAlcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact
information.
How to order
To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS) (http://support.alcatel-lucent.com)
How to comment
To comment on this document, go to the Online Comment Form (http://infodoc.alcatel-lucent.com/comments/) or e-mail your comments to the Comments Hotline
About this document
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
xv
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 16/68
About this document
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
xvi Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 17/68
1 1Safety statements
Overview
Purpose
This chapter provides information on the structure of safety statements which may arise
in the course of your work.
Contents
Structure of safety statements 1-2
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
1-1
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 18/68
Structure of safety statements
Overview
This topic describes the components of safety statements that appear in this document.
General structure
Safety statements include the following structural elements:
Item Structure element Purpose
1 Safety alert symbol Indicates the potential for personal injury
(optional)
2 Safety symbol Indicates hazard type (optional)
3 Signal word Indicates the severity of the hazard
4 Hazard type Describes the source of the risk of damage or
injury
5 Safety message Consequences if protective measures fail
6 Avoidance message Protective measures to take to avoid the hazard
7 Identifier The reference ID of the safety statement
(optional)
SA M P L E
B C D
E F
G
H
Lifting this equipment by yourself can result in injury
due to the size and weight of the equipment.
Always use three people or a lifting device to transport and position this equipment. [ABC123]
CAUTION
Lifting hazard
Safety statements Structure of safety statements
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1-2 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 19/68
Signal words
The signal words identify the hazard severity levels as follows:
Signal word Meaning
DANGER Indicates an extremely hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING Indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION Indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE Indicates a hazardous situation not related to personal injury.
Safety statements Structure of safety statements
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
1-3
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 20/68
Safety statements Structure of safety statements
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1-4 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 21/68
2 2Preventive maintenance
Overview
Purpose
This chapter describes the preventive maintenance activity applicable to the RRH
2X60W.
Contents
Preventive maintenance activity 2-2
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
2-1
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 22/68
Preventive maintenance activity
Preventive maintenance
The preventive maintenance is used to periodically test the items of equipment that do not
directly trigger any alarm at the WMS. However, the execution of preventive maintenance procedures can trigger alarms at the WMS.
These procedures must be performed according to the following schedules.
It is possible to group some of the procedures, which reduces the intervention time. The
intervention time indicated corresponds to the intervention time for each item of
equipment.
Note: In certain environments, these procedures may be required more frequently:
• Systems located in high seismic areas may require anchor bolts and mounting
hardware to be tightened periodically especially for field installed items.
• Connectors may require periodic cleaning in dirty and high humidity areas.
Preventive maintenance schedule for RRH 2X60W equipment
Procedure Periodicity Test duration(approx.)
“Inspecting connectors” (p. 7-2) Every two years 10 minutes
“Inspecting pole brackets and pole bands”
(p. 7-4)
Every two years 10 minutes
Preliminary checks before performing preventive maintenance procedures
WARNING
Personal injury hazard
The personnel working on the cabinet must be authorized to work according to the
applicable safety standards
Preventive maintenance Preventive maintenance activity
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-2 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 23/68
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Description of a preventive maintenance procedure
A preventive maintenance procedure is divided into the following parts:
• Title
• Main body with following information:
– Intervention time
– Tools required
– Step-by-step actions
– One or more figures to help you execute the actions
Preventive maintenance Preventive maintenance activity
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
2-3
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 24/68
Preventive maintenance Preventive maintenance activity
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-4 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 25/68
3 3Corrective maintenance
Overview
Purpose
This chapter describes the corrective maintenance activity applicable to the RRH 2X60W.
Contents
Corrective maintenance 3-2
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
3-1
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 26/68
Corrective maintenance
Corrective maintenance activity
The network maintenance is based on the supervision of the network, by using the OAM
graphical interface. For more information, see Alcatel-Lucent 9353 Wireless Management System - User Guide, 9YZ-04088-0014-PCZZA.
It is also based on the identification and replacement of faulty items of equipment, using
the alarms.
The process consists of two steps:
1. Locating and identifying the faulty RRH 2X60W through alarms at the WMS. See
"Fault management" chapter in Alcatel-Lucent 9353 Wireless Management System -
User Guide, 9YZ-04088-0014-PCZZA.
2. Replacing the faulty RRH 2X60W following the replacement procedure detailed in
this publication.
RRH 2X60W replacement
In the case of the RRH 2X60W, no separate module replacement exists: the whole RRH
2X60W is to be replaced. The procedure is detailed in “Replacing an RRH 2X60W”
(p. 8-2).
The following table indicates the orderable item (code) for each module or item to be
replaced from the RRH 2X60W variants.
Table 3-1 RRH 2X60W orderable items
RRH 2X60W
module/item
Orderable item Provisioning rule
SFP Optical Transceiver
Multi Mode, Dual Fiber
1AB187280063 One SFP per RRH to be installed in
CPRI_PRI.
SFP Optical Transceiver
Single Mode, Single Fiber
1AB194670019 If single-mode: provide one SFP per
RRH to be installed in CPRI_PRI.
SFP Optical Transceiver
Single Mode, Dual Fiber
1AB187280065 One SFP per RRH to be installed in
CPRI_PRI.
Cable alarm connectorized
-15M
849138136 One if external alarm option is required
For optional orderable items, see the following documents:
• RRH 2X60-XX Model Offer Provisioning Guide, UMT/PFO/APP/032664
Corrective maintenance Corrective maintenance
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
3-2 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 27/68
Description of a replacement procedure
A replacement procedure is divided into the following parts:
• Title
• Main body with the following information:
– Intervention time – Tools required
– Impact of the procedure, if necessary
– Step-by-step actions
One or more figures are provided to help you execute the actions.
Intervention restrictions
There may be a lapse of time between the identification of the alarm at the Access OAM
Graphic User Interface (GUI) and the time you arrive at the site.
You must be synchronized with the access network controller or system administrator (by
telephone) before an on-site intervention, in the following cases:
• Isolating procedures
• Completion of an on-site intervention
• Return to service procedure
General personnel safety instructions
The personnel must obey the safety instructions specific to the installation site:
• Rules concerning the premises (see instructions posted on site or in the building)
• Rules linked to general personnel safety instructions
The personnel working on the cabinet must be authorized to work according to security
standards.
Equipment safety instructions
The external temperature must be comprised between – 40°C and + 50°C.
Corrective maintenance Corrective maintenance
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
3-3
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 28/68
Corrective maintenance Corrective maintenance
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
3-4 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 29/68
4 4Introduction
Overview
Purpose
This chapter presents the RRH 2X60W solution.
Contents
RRH 2X60W solution 4-2
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
4-1
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 30/68
RRH 2X60W solution
RRH 2X60W overview
The RRH 2X60W is a solution for a remote RF transceiver that can be located far away
(500 m to 20 km) from a main Node B and interface with this main Node B through anoptical fiber.
The RRH 2X60W provides an external optical interface to be connected to the optical
module of the main Node B.
It also provides an external radio interface according to UMTS standards.
The following figure shows the connections between RRHs and a d2U Node B in star
configuration.
For details concerning the configurations of implementation, refer to chapter 3 in the
document: Alcatel-Lucent Remote Radio Head 2X60W - 850, 1900 MHz - Technical
Description, 3MN-01477-0003-DEZZA.
Figure 4-1 Connections between RRH 2X60W and a d2U Node B
Introduction RRH 2X60W solution
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-2 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 31/68
5 5Hardware description
Overview
Purpose
This chapter describes:
• The RRH bulkhead hardware• The connectivity
• The LED indicators
It also specifies the Node B hardware requirements for RRH support.
Contents
RRH 2X60-1900/1900A hardware description 5-2
RRH 2X60-850 and hardware description 5-7
Node B hardware requirements for RRH support 5-11
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
5-1
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 32/68
RRH 2X60-1900/1900A hardware description
Bulkhead description
The following figure shows the top view of the RRH 2X60-1900 bulkhead:
Figure 5-1 RRH 2X60-1900 two antennas bulkhead top view
Hardware description RRH 2X60-1900/1900A hardware description
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
5-2 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 33/68
The following figure shows the top view of the RRH 2X60-1900A bulkhead:
Figure 5-2 RRH 2X60-1900A four antennas bulkhead top view
Hardware description RRH 2X60-1900/1900A hardware description
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
5-3
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 34/68
The following figure shows the bottom view of the RRH 2X60-1900/1900A bulkhead:
Connector description
This topic gives an overview of the connectors located on the RRH bulkhead.
Interface Connector
Power –48 V DC
GND Ground connectionALD (Antenna Line Device) Antenna power and control
1 AISG (RS485) connector
8-pin Circular Din female connector
Support of RETA compatible with AISG 2.0.
Figure 5-3 RRH 2X60-1900/1900A bulkhead bottom view
Hardware description RRH 2X60-1900/1900A hardware description
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
5-4 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 35/68
Interface Connector
TX1/RX1 Transmit and receive antenna path
7/16 DIN coaxial female connector for the
connection with the antenna
TX2/RX2 Receive diversity antenna path
7/16 DIN coaxial female connector for the
connection with the diversity antenna
ALM1-3, ALM 4-6 External user alarms connector
Six user alarms
Implemented with 2 X 8-pin circular DIN
female connectors .
CPRI _PRI CPRI optical port
Used to connect the RRH to the Node B or
another RRH
SFP, with waterproof Radiall flange connector
(which includes the protective metal cover)
CPRI_SEC CPRI optical port
Used to connect the RRH to the Node B
SFP, with waterproof Radiall flange connector
(which includes the protective metal cover
RX3 and RX4 2 Rx ports located on the top of the RRH
2X60-1900A
RX3 and RX4 are not connected in WCDMAmode of operation, a waterproof cap protects
the unused connectors
MAINT Local maintenance terminal2 (MAINT) RJ45
connector located on the bottom of the RRH.
Notes:
1. A reset button is located next to the MAINT port.
LED description (STATUS)
There is only one green-red-yellow tri-colored LED. The Base Band Unit (BBU) gets the
LED status periodically and reports it to the management system.
The table below summarizes these states in priority order, from highest (1) to lowest (13).
Hardware description RRH 2X60-1900/1900A hardware description
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
5-5
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 36/68
Note that one states in the table is marked as not applicable (‘n/a’) for the single LED
display (Background download). In these cases no LED setting is assigned and so the
LED setting defaults to the next lower priority active setting.
ID RTU State Description LED
Display
1 No power Supplied. No AC or DC power (dead unit). Off
2 Initial power On. RTU is initializing. Solid Red
3 External Power Supply
Failure.
AC or DC input power feed is out of range. Flash Red
4 Software download. The unit is downloading software and RF
transmission is off, but is currently
operational.
Flash Yellow
5 Nonrecoverable Critical
Failure.
A critical hardware failure prevents either the
transmit path or the active receive paths (or all paths) from functioning.
Solid Red
6 Recoverable Critical
Failure.
The unit is not currently operational due to
hardware fault, but should recover (e.g.,
Under-Temperature Warm-Up or
Over-Temperature Critical Shutdown.
Flash Red
7 CPRI_PRI link Failure. CPRI_PRI link has failed. Solid Yellow
8 Non-Critical
Nonrecoverable
Failure.
Non-Critical fault (other than antenna)
detected, fault is not recoverable, transmission
is still on.
Solid Red
9 Non-Critical
Recoverable Failure.
Non-Critical fault (other than antenna)
detected, fault is recoverable, transmission is
still on.
Flash Red
10 ExternalAntenna
Failure.
An equipped antenna has a VSWR fault. Flash Red
11 Background Software
Download.
A background software download is in
progress, RF is currently enabled.
n/a
12 Normal Operation. No critical failures or faults, transmitter is
enabled.
Solid Green
13 Standby. No critical failures or faults, but the transmitter is disabled.
Flash Green
Hardware description RRH 2X60-1900/1900A hardware description
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
5-6 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 37/68
RRH 2X60-850 and hardware description
Bulkhead description
The following figures show the top view of the RRH 2X60-850 bulkhead:
Figure 5-4 RRH 2X60-850 two antennas bulkhead top view
Hardware description RRH 2X60-850 and hardware description
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
5-7
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 38/68
The following figure shows the bottom view of the RRH 2X60-850 bulkhead:
Connector description
This topic gives an overview of the connectors located on the RRH bulkhead.
Interface Connector
Power –48 V DC
GND Ground connection
ALD (Antenna Line Device) Antenna power and control
1 AISG (RS485) connector
8-pin Circular Din female connector
Support of RETA compatible with AISG 2.0.
Figure 5-5 RRH 2X60-850 bulkhead bottom view
Hardware description RRH 2X60-850 and hardware description
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
5-8 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 39/68
Interface Connector
TX/RX Transmit and receive antenna path
7/16 DIN coaxial female connector for the
connection with the antenna
ALM1-3, ALM4-6 External user alarms connector
Six user alarms
Implemented with 2 X 8-pin circular DIN
female connectors (same as AISG).
CPRI _PRI CPRI optical port
Used to connect the RRH to the Node B or
another RRH
SFP, with waterproof Radiall flange connector
(which includes the protective metal cover)
CPRI_SEC CPRI optical port
Used to connect the RRH to the Node B
SFP, with waterproof Radiall flange connector
(which includes the protective metal cover
AUX Rx Two AUX ports1 (AUX_RX1, AUX_RX2)
SMA female connector
MAINT Local maintenance terminal2 (MAINT) RJ45
connector located on the bottom of the RRH
2X60-850.
Notes:
1. The two AUX SMA ports are used for antenna sharing feature. They can be configured as
RX ports to bypass the Low Noise Amplifier (LNA) and filters inside the RRH. They also
can be configured as TX ports to output received signal of the main RX ports with 25 dB
gain.
2. A reset button is located next to the MAINT port.
LED description (STATUS)
There is only one green-red-yellow tri-colored LED. The Base Band Unit (BBU) gets the
LED status periodically and reports it to the management system.
The table below summarizes these states in priority order, from highest (1) to lowest (13).
Hardware description RRH 2X60-850 and hardware description
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
5-9
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 40/68
Note that one states in the table is marked as not applicable (‘n/a’) for the single LED
display (Background download). In these cases no LED setting is assigned and so the
LED setting defaults to the next lower priority active setting.
ID RTU State Description LED
Display
1 No power Supplied. No AC or DC power (dead unit). Off
2 Initial power On. RTU is initializing. Solid Red
3 External Power Supply
Failure.
AC or DC input power feed is out of range. Flash Red
4 Software download. The unit is downloading software and RF
transmission is off, but is currently
operational.
Flash Yellow
5 Nonrecoverable Critical
Failure.
A critical hardware failure prevents either the
transmit path or the active receive paths (or all paths) from functioning.
Solid Red
6 Recoverable Critical
Failure.
The unit is not currently operational due to
hardware fault, but should recover (e.g.,
Under-Temperature Warm-Up or
Over-Temperature Critical Shutdown.
Flash Red
7 CPRI_PRI link Failure. CPRI_PRI link has failed. Solid Yellow
8 Non-Critical
Nonrecoverable
Failure.
Non-Critical fault (other than antenna)
detected, fault is not recoverable, transmission
is still on.
Solid Red
9 Non-Critical
Recoverable Failure.
Non-Critical fault (other than antenna)
detected, fault is recoverable, transmission is
still on.
Flash Red
10 ExternalAntenna
Failure.
An equipped antenna has a VSWR fault. Flash Red
11 Background Software
Download.
A background software download is in
progress, RF is currently enabled.
n/a
12 Normal Operation. No critical failures or faults, transmitter is
enabled.
Solid Green
13 Standby. No critical failures or faults, but the transmitter is disabled.
Flash Green
Hardware description RRH 2X60-850 and hardware description
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
5-10 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 41/68
Node B hardware requirements for RRH support
Requirement
The following Node Bs are programmed to support RRH.
Parameter RRH 2X60 - 850/1900/1900A
BBU 9396 d2U or d4U
Hardware description Node B hardware requirements for RRH support
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
5-11
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 42/68
Hardware description Node B hardware requirements for RRH support
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
5-12 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 43/68
6 6Power up and power down
procedures
Overview
Purpose
This chapter describes how to power up and power down the RRH 2X60W.
Contents
Powering up an RRH 2X60W 6-2
Powering down an RRH 2X60W 6-4
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
6-1
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 44/68
Powering up an RRH 2X60W
Before you begin
WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage.
For this reason, only trained and qualified personnel (electrical workers as defined in
IEC 60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA
No.10) may install or service the installation.
Procedure
Perform the following procedure to power up an RRH 2X60W.
...................................................................................................................................................................................................
1 Check that the circuit breaker dedicated to the RRH 2X60W is 15A.
...................................................................................................................................................................................................
2 Connect the power cable to the DC connector on the RRH 2X60W bulkhead, see Chapter
5, “Hardware description”
...................................................................................................................................................................................................
3 Connect the power cable to the power source (– 48 V DC) on the customer site.
...................................................................................................................................................................................................
4 Switch ON the circuit breaker.
...................................................................................................................................................................................................
5 Wait for RRH start-up.
...................................................................................................................................................................................................
6 Check that the status LEDs on the bulkhead display normal operation, see Chapter 5,
“Hardware description”. If a non-compliance LEDs status occurred then contact the site
coordinator before going on.
...................................................................................................................................................................................................
7 On the xCCM optical port, check that the Tx and Rx LEDs are green.
Power up and power down procedures Powering up an RRH 2X60W
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
6-2 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 45/68
...................................................................................................................................................................................................
8 Check with the WMS administrator if there is not unexpected alarms and that the RRH
2X60W is operational.
Power up and power down procedures Powering up an RRH 2X60W
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
6-3
PRELI MI NA
RY
PRELI MI NARY
E N D O F S T E P S...................................................................................................................................................................................................
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 46/68
Powering down an RRH 2X60W
Before you begin
WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage.
For this reason, only trained and qualified personnel (electrical workers as defined in
IEC 60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA
No.10) may install or service the installation.
Procedure
Perform the following procedure to power down an RRH 2X60W.
...................................................................................................................................................................................................
1 Switch OFF the circuit breaker on the customer power supply plant.
...................................................................................................................................................................................................
2 Check that the RRH 2X60W is powered off. All LEDs are OFF.
...................................................................................................................................................................................................
3 Disconnect the power cable dedicated to the RRH from the power source (-48 V DC) on
the customer site.
...................................................................................................................................................................................................
4 Unscrew the power cable from the RRH DC connector on the RRH 2X60W bulkhead, see
Chapter 5, “Hardware description”.
Power up and power down procedures Powering down an RRH 2X60W
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
6-4 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
E N D O F S T E P S...................................................................................................................................................................................................
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 47/68
7 7Preventive maintenance
procedures
Overview
Purpose
This chapter contains the preventive maintenance procedures applicable to the RRH
2X60W.
Contents
Inspecting connectors 7-2
Inspecting pole brackets and pole bands 7-4
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
7-1
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 48/68
Inspecting connectors
Before you begin
Intervention time: 10 minutes
Tools required: adjustable wrench
WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage.
For this reason, only trained and qualified personnel (electrical workers as defined in
IEC 60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA
No.10) may install or service the installation.
NOTICE
Service-disruption hazard
This procedure will result in service disruption. Notify the WMS administrator of a
service outage before commencing.
Important! The personnel working on the cabinet must be authorized to work
according to the security standards.
NOTICEESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Procedure
Carry out the following procedure to inspect the connector seals on an RRH 2X60W
bulkhead.
...................................................................................................................................................................................................
1 Check the bulkhead connectors visually, see Chapter 5, “Hardware description”.
...................................................................................................................................................................................................
2 Check that connectors are well tightened.
Preventive maintenance procedures Inspecting connectors
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-2 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 49/68
Result: If they move, tighten them with the adjustable wrench.
Preventive maintenance procedures Inspecting connectors
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
7-3
PRELI MI NA
RY
PRELI MI NARY
E N D O F S T E P S...................................................................................................................................................................................................
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 50/68
Inspecting pole brackets and pole bands
Before you begin
The RRH can be installed in an outdoor environment using one of the following mounting
kits:• Floor
• Wall
• Pole (50-152 mm)
• Pole (152-380 mm)
Intervention time: 10 minutes
Tools required:
• 17-mm (11/16") socket with ratchet
• 14-mm (9/16") open-end wrench
WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage.
For this reason, only trained and qualified personnel (electrical workers as defined in
IEC 60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA
No.10) may install or service the installation.
NOTICE
Service-disruption hazard
This procedure will result in service disruption. Notify the WMS administrator of a
service outage before commencing.
Important! The personnel working on the cabinet must be authorized to work
according to the security standards.
Preventive maintenance procedures Inspecting pole brackets and pole bands
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-4 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 51/68
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Procedure
Carry out the following procedure to check the pole brackets and pole bands of the RRH
2X60W.
...................................................................................................................................................................................................
1 Perform a visual test:
• Check that the pole brackets are well tightened to the wall bracket. If not, go to Step 2
.
• Check that the pole bands are well tightened around the pole. If not, go to Step 2.
...................................................................................................................................................................................................
2 Tighten the pole brackets and/or the pole bands.
Note: Use the 17-mm socket to tighten the pole brackets (tightening torque: 32.2
N.m).
Use the 14-mm open-end wrench to tighten the pole bands.
Figure 7-1 Pole brackets and pole bands
Preventive maintenance procedures Inspecting pole brackets and pole bands
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
7-5
PRELI MI NA
RY
PRELI MI NARY
E N D O F S T E P S...................................................................................................................................................................................................
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 52/68
Preventive maintenance procedures Inspecting pole brackets and pole bands
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-6 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 53/68
8 8Corrective maintenance
procedure
Overview
Purpose
This chapter describes the corrective maintenance procedure applicable to the RRH
2X60W.
Contents
Replacing an RRH 2X60W 8-2
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
8-1
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 54/68
Replacing an RRH 2X60W
Before you begin
The replacement procedure described below is based on the following assumptions:
• An investigation was performed and it was determined that the unit to replace wasfaulty.
• The existing unit is locked at the WMS.
• To replace the RRH 2X60W main body with another RRH 2X60W, you ordered one
of the following spare parts:
– RRH 2X60-850, two antennae pre-integrated cabinet 3JR10601AA
– RRH 2X60-1900, two antennae pre-integrated cabinet 3JR10801AA
– RRH 2X60-1900A, four antennae pre-integrated cabinet 3JR39501AA
Note: For details, see Table 3-1, “RRH 2X60W orderable items” (p. 3-2)
Note: The RRH 2X60W remains supplied with the mains power supply.Note: The RRH 2X60W has an integrated handle that does not detach from the unitonce it is installed.
Intervention time:
• 30 minutes
Required tools
Tool Quantity Description,
7/16 Torque Wrench 1 Torque value: 25 Nm -1/+2
Nm / 221 lbf.in -8.8/+17.7
lbf.in
T25 TORX security drive 1
Fiber cleaning kit 1
Hexagonal Keys 1 6 mm
Screwdrivers for slotted heads 1
Set torx screwdriver 1
While the technician is on site, the local configuration data and “TTLNA” data fields are
set with the local management terminal. The technician needs to commission the RRHwith RMT. The initialization, reset, boot, software download, occur with the WMS. The
configuration of the RRH 2X60W with the proper parameter settings are also established
through the WMS. Many of the settings, commissioning data, local configuration data,
and parameters might not have to be changed at all with the replacement of a faulty unit
with a new hardware unit.
Corrective maintenance procedure Replacing an RRH 2X60W
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
8-2 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 55/68
WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage.
For this reason, only trained and qualified personnel (electrical workers as defined in
IEC 60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA
No.10) may install or service the installation.
NOTICE
Service-disruption hazard
This procedure will result in service disruption. Notify the WMS administrator of a
service outage before commencing.
Important! The personnel working on the cabinet must be authorized to work according to the security standards.
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Procedure
Carry out the following procedure to replace an RRH 2X60W.
...................................................................................................................................................................................................
1 Preliminary operations:
• Shut down the RRH 2X60W, see the procedure “Powering down an RRH 2X60W”
(p. 6-4).
• Remove the solar shield, using the T25 TORX security drive, and store it in a safe
location.
• Disconnect all external cables from the bulkhead.
• Remove the two RF lightning protectors from the 7/16 female RF connectors (on top
of the main body) and store them in a safe location.
Corrective maintenance procedure Replacing an RRH 2X60W
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
8-3
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 56/68
...................................................................................................................................................................................................
2 Remove the defective RRH 2X60W:
• Unscrew the four bolts from the mounting bracket.
• Remove the RRH 2X60W from the mounting bracket.
...................................................................................................................................................................................................
3 Before sending the defective RRH 2X60W to the Repair Center, store the solar shield and
the RF lightning protectors, since these items will be reused for installation of the new
RRH 2X60W.
Note: Only the main body of the defective RRH 2X60W is to be sent to the Repair
Center.
...................................................................................................................................................................................................
4 Keep the existing cables and protect the connectors with caps near to the existing RRH to
be re-used if necessary.
...................................................................................................................................................................................................
5 Reinsert the new RRH 2X60W:
• Insert the two RF lightning protectors on the 7/16 female RF connectors (on top of the
main body).
• Hang the new RRH 2X60W on the mounting bracket.
• Screw the four M10 bolts to the mounting bracket.
• Connect all external cables to the RRH 2X60W.
Refer to chapter 6 in the document: Alcatel-Lucent Remote Radio Head 2X60 W -850, 1900MHz - Hardware Installation, 3MN-01477-0002-RJZZA
• Install the solar shield using the T25 TORX security drive.
...................................................................................................................................................................................................
6 Switch on the RRH 2X60, see the procedure “Powering up an RRH 2X60W” (p. 6-2).
...................................................................................................................................................................................................
7 Check with the WMS administrator that the RRH 2X60W is operational.
Corrective maintenance procedure Replacing an RRH 2X60W
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
8-4 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
E N D O F S T E P S...................................................................................................................................................................................................
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 57/68
Appendix A: Product
conformance statements
Overview
Purpose
This appendix provides the RRH product conformance statements.
Contents
European regulatory requirement compliance A-2
Americas Region regulatory requirement compliance A-4
Federal Communications Commission A-5
Compliances for other regions/countries A-7
Operating conditions A-8
Cable specifications A-9
Product labeling A-10
...................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
A-1
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 58/68
European regulatory requirement compliance
Radio and Telecom Terminal Equipment
The RRH falls under the requirements of the Radio and Telecom Terminal Equipment
(R&TTE) European directive 1999/5/EC.The R&TTE directive covers requirements in the following areas:
• Protection of the Health and Safety of users and all other persons, including objectives
with respect to safety requirements contained in the Low Voltage Directive
(73/23/EEC)
Electromagnetic compatibility (EMC) protection requirements contained in Directive89/336/EEC.
This equipment generates, uses, and can radiate radio frequency energy. If notinstalled and used in accordance with the instruction manual, it can interfere withradio communications. However, there is no guarantee that interferences do not occur in a particular installation. If this equipment does cause harmful interference to radioor television reception, which can be determined by turning the equipment off and on.The user is encouraged to correct any interference problems. EMC requirements have been selected to ensure an adequate level of compatibility for apparatus in residential,commercial, and light industrial environments. Compatibility levels, however, do notcover extreme cases that can occur in any location, but that have a low probability of occurrence. In particular, they may not cover cases where a source of interference thatis producing repeated transient or continuous phenomena is permanently present. Thiscould include, for example, a radar or broadcast site in the near vicinity. In thesecases, it may be necessary to limit the source of interference, and/or apply special protection to the interfered part.
Note: For operation or maintenance inside Alcatel-Lucent systems, the operator must
always wear the antistatic wrist strap to maintain the integrity of the product.• Effective use of the Radio spectrum allocated to terrestrial/space radio communication
and orbital resources to avoid interference. The routes and standards used to
demonstrate compliance with these requirements are outlined in the following
paragraphs:
– Node B EMC
Compliance with essential EMC requirements was demonstrated using E301489-1& -23.
– Node B radio compliance
Compliance with the requirements of effective use of the radio spectrum was
demonstrated using E301908-1 & -3. – Node B safety
Compliance with essential safety requirements was demonstrated using EN60950.
– Node B health protection
Compliance with essential health requirements was demonstrated using E50385.
Product conformance statements European regulatory requirement compliance
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
A-2 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 59/68
European Union Environmental Directives (EUED)
The RRH is manufactured according to the following two European Union
Environmental Directives:
• Restriction of Hazardous Substances (RoHS), 2002/95/EC
The RoHS directive restricts the use of lead, mercury, cadmium, hexavalentchromium, poly-brominated biphenyls (PBB) and poly-brominated diphenyl ethers(PBDE) in electrical and electronic products. This directive applies to all electricaland electronic products placed on the European Union (EU) and European EconomicArea (EEA) markets after July 1, 2006, with certain exemptions, including anexemption for lead solder in network infrastructure equipment.
• Waste of Electrical and Electronic Equipment (WEEE), 2002/96/EC
The WEEE directive mandates the necessary treatment of such equipment when itenters end-of-life. It specifically identifies requirements for recycling, reuse, anddisposal.
Product conformance statements European regulatory requirement compliance
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
A-3
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 60/68
Americas Region regulatory requirement compliance
United States
The statements that follow are the product conformance statements that apply to the
Alcatel-Lucent Remote Radio Head 2X60W when deployed in the Americas Region.
Product conformance statements Americas Region regulatory requirement compliance
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
A-4 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 61/68
Federal Communications Commission
Federal Communications Commission
Important! Changes or modifications not expressly approved by Alcatel-Lucent, Inc.
could void the user’s authority to operate the equipment.This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
FCC Part 15 Class B
Note: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected
• Consult the dealer or an experienced radio/TV technician for help.
FCC Part 68
This equipment complies with Part 68 of the FCC rules and the requirements adopted by
the ACTA. At the upper-right-hand corner inside the cabinet assembly of this equipmentis a label that contains, among other information, a product identifier in the format of
AAAEQ##TXXXX. If requested, this number must be provided to the telephone
company.
FIC 04DU9-1SN.
Product conformance statements Federal Communications Commission
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
A-5
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 62/68
SOC 6.0N
The T1 network interface on this equipment is hardwired to a punchdown block, which
meets the FCC specifications.
If this equipment causes harm to the telephone network, the telephone company willnotify you in advance that temporary discontinuance of service may be required.
However, if advance notice is not practical, the telephone company will notify the
customer as soon as possible. Also, you will be advised of your right to file a complaint
with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations, or
procedures that could affect the operation of the equipment. If this happens, the telephone
company will provide advance notice in order for you to make necessary modifications to
maintain uninterrupted service.
FCC regulations prohibit the connection of customer-provided equipment to central office
implemented systems. Connection to party lines is subject to tariffs; users should contact
their state public utility commission, public service commission, or corporation
commission for information.
If the equipment is causing harm to the telephone network, the telephone company may
request that you disconnect the equipment until the problem is resolved.
If trouble is experienced with this equipment repair or warranty information may be
obtained by contacting:
Technical Support Services, within the United States: +1 630 224 4762, prompt 2
RF approval
This equipment complies with Part 2, Subpart J - Equipment Authorization Procedures, of
the FCC Rules.
This device complies with Part 22 – Public Mobile Services, Subpart H – Cellular
Radiotelephone Services.
This equipment complies with Part 24 - Personal Communications Services, Subpart E -
Broadband PCS.
Product conformance statements Federal Communications Commission
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
A-6 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 63/68
Compliances for other regions/countries
Compliances for other regions/countries
It is impossible to list all the applicable approvals/compliances as they depend on the
markets and products concerned.Note: For more information, contact your local Alcatel-Lucent representative.
Product conformance statements Compliances for other regions/countries
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
A-7
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 64/68
Operating conditions
Operating conditions
The product compliance standards mentioned above are based on the following operating
conditions:• Doors must be closed and/or covers must be in place.
• External cables must be of the same type as specified by Alcatel-Lucent.
• The mechanical and electrical characteristics of the product must not be modified in
any way.
Any changes or modifications made to the product without written approval from
Alcatel-Lucent releases Alcatel-Lucent from responsibility regarding standards
compliance.
Product conformance statements Operating conditions
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
A-8 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 65/68
Cable specifications
Cable specifications
Compliance with these standards was verified using cables as specified by
Alcatel-Lucent. The continued compliance of the product relies upon use of the correctcabling scheme as well as use of identical type cables as specified by Alcatel-Lucent.
Refer to the installation guides for details on cable specifications.
Product conformance statements Cable specifications
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
A-9
PRELI MI NA
RY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 66/68
Product labeling
Product labeling
The product label can be located on the inside or the outside of the product, provided that
the operation and/or maintenance personnel have the information when working on the product.
Node B labelling for European countries
To indicate compliance with the European R&TTE Directive, the RRH bears the
following label in a visible location:
• Manufacturers name
• Equipment designation
• Nominal voltage and maximum rated current
Labelling for other regions / countries
Labelling for other regions and countries is performed as appropriate and required by the
local regulatory framework.
Product conformance statements Product labeling
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
A-10 Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZA
Issue 0.02 January 2014 P R E L I M I N A R Y
P
R E L I M I N A R Y
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 67/68
Index
B bulkhead, 5-2, 5-7
.............................................................
C connectors, 5-2, 5-7
procedure, 7-2
.............................................................
I inspecting
pole bands, 7-4
pole brackets, 7-4
.............................................................
M maintenance
preventive, 2-2
.............................................................
O orderable items, 3-2
.............................................................
P pole bands
inspecting, 7-4
pole brackets
inspecting, 7-4
powering down
RRH 2X60W, 6-4
powering up
RRH 2X60W, 6-2
preventive
maintenance, 2-2
procedure
connectors, 7-2
.............................................................
R replacement procedure, 3-2
replacing procedure
RRH 2X60W, 8-2
requirement, 5-11
.............................................................
S Safety statements, 1-1, 1-2
....................................................................................................................................................................................................................................
Alcatel-Lucent RRH 2X60W3MN-01477-0004-REZZAIssue 0.02 January 2014
Alcatel-Lucent – ProprietaryUse pursuant to applicable agreements
IN-1
PRELI M
I NARY
PRELI MI NARY
7/17/2019 RRH.pdf
http://slidepdf.com/reader/full/rrhpdf 68/68
Index
....................................................................................................................................................................................................................................
P
R E L I M I N A R Y